• Title/Summary/Keyword: Intra-thoracic

Search Result 120, Processing Time 0.022 seconds

Twenty-Four Hour pH Study and Manometry in Gastric Esophageal Substitutes in Children

  • Kekre, Geeta;Dikshit, Vishesh;Kothari, Paras;Laddha, Ashok;Gupta, Abhaya
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.4
    • /
    • pp.257-263
    • /
    • 2018
  • Purpose: Studies on the physiology of the transposed stomach as an esophageal substitute in the form of a gastric pull-up or a gastric tube in children are limited. We conducted a study of motility and the pH of gastric esophageal substitutes using manometry and 24-hour pH measurements in 10 such patients. Methods: Manometry and 24 hour pH studies were performed on 10 children aged 24 to 55 months who had undergone gastric esophageal replacement. Results: Six gastric tubes (4, isoperistaltic; 2, reverse gastric tubes) and 4 gastric pull-ups were studied. Two gastric tubes and 4 gastric pull-ups were transhiatal. Four gastric tubes were retrosternal. The mean of the lowest pH at the midpoint of the substitute was 4.0 (range, 2.8-5.0) and in the stomach remaining below the diaphragm was 3.3 (range, 1.9-4.2). In both types of substitute, the difference between the peak and the nadir pH recorded in the intra-thoracic and the sub-diaphragmatic portion of the stomach was statistically significant (p<0.05), with the pH in the portion below the diaphragm being lower. The lowest pH values in the substitute and in the remnant stomach were noted mainly in the evening hours whereas the highest pH was noted mainly in the morning hours. All the cases showed a simultaneous rise in the intra-cavitatory pressure along the substitute while swallowing. Conclusion: The study suggested a normal gastric circadian rhythm in the gastric esophageal substitute. Mass contractions occurred in response to swallowing. The substitute may be able to effectively clear contents.

Clinical Analysis of the Early Result of Coronary Artery bypass Graft (관상동맥 우회로술 154예이 조기 임상 결과)

  • Song Chang Min;Ahn Jae Bum;Kim Woo Shik;Shin Yong Chul;Yoo Hwan Kook;Kim Byung Yul;Kim In-Sub
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.476-482
    • /
    • 2005
  • Recently, coronary artery obstructive disease and coronary artery bypass graft surgery have increased, and the operative result has been improved. We reviewed 154 cases of coronary artery bypass graft surgery from Jan. 1985 to Jun. 2004. Material and Method: We reviewed 148 patients, 154 cases of coronary artery bypass surgery from Jan. 1985 to Jun. 2004. This investigation is designed to illustrate the preoperative diagnosis, severity of disease, operative method, the kind of used bypass graft used, number of distal anasomosis, associated surgery, and postoperative morbidity and mortality. Result: There were 84 males, 64 females and the average age was $58.9\pm8.3$ years old. Preoperative clinical diagnosis were unstable angina in 97 cases $(63.0\%)$, stable angina in 31 cases $(20.1\%)$, acute myocardial infarction in 12 cases $(7.8\%)$ and postinfartion angina in 14 cases $(9.1\%)$. Preoperative angiographic diagnosis were three-vessel disease in 68 $(44.2\%)$, two-vessel disease in 39 $(25.3\%)$, one-vessel disease in 35$(22.7\%)$, and left main disease in 12$(7.8\%)$ cases. There were 78 cases of on-pump coronary artery bypass graft surgery and 76 cases of off-pump coronary artery bypass graft surgery. The total distal anastomoses number was 319, mean number of anastomoses was $2.06\pm0.96$. There were 10 concomitant procedures. Postoperative intra-aortic balloon pump was used in 21$(13.6\%)$ cases, but only 4 cases were used at off-pump coronary artery bypass surgery. Total early mortality was $7.8\%$. The mortality was decreased as $4.5\%$ from Jan. 2001 to Jun. 2004. Post operative complication was perioperative yocardial infarction in 9cases$(5.8\%)$, low cardiac output syndrome in 17 cases$(11\%)$, and arrhythmia in 30 cases$(19.5\%)$ cases. Conclusion: Since 1985, The result of coronary artery bypass graft surgery has been improved because of more refined technique, use of off-pump coronary artery bypass surgery, use of internal thoracic artery and radial artery as bypass graft. We should study the long-term follow up more for better operative results.

Does Additional Aortic Procedure Carry a Higher Risk in Patients Undergoing Aortic Valve Replacement?

  • Kim, Tae-Hun;Park, Kay-Hyun;Yoo, Jae Suk;Lee, Jae Hang;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.45 no.5
    • /
    • pp.295-300
    • /
    • 2012
  • Background: With growing attention to the aortopathy associated with aortic valve diseases, the number of candidates for accompanying ascending aorta and/or root replacement is increasing among the patients who require aortic valve replacement (AVR). However, such procedures have been considered more risky than AVR alone. This study aimed to compare the surgical outcome of isolated AVR and AVR combined with aortic procedures. Materials and Methods: A total of 86 patients who underwent elective AVR between 2004 and June 2010 were divided into two groups: complex AVR (n=50, AVR with ascending aorta replacement in 24 and the Bentall procedure in 26) and simple AVR (n=36). Preoperative characteristics, surgical data, intra- and postoperative allogenic blood transfusion requirement, the postoperative clinical course, and major complications were retrospectively reviewed and compared. Results: The preoperative mean logistic European System for Cardiac Operative Risk Evaluation (%) did not differ between the groups: $11.0{\pm}7.8%$ in the complex AVR group and $12.3{\pm}8.0%$ in the simple AVR group. Although complex AVR required longer cardiopulmonary bypass ($152.4{\pm}52.6$ minutes vs. $109.7{\pm}22.7$ minutes, p=0.001), the quantity of allogenic blood products did not differ ($13.4{\pm}14.7$ units vs. $13.9{\pm}11.2$ units). There was no mortality, mechanical circulatory support, stroke, or renal failure requiring hemodialysis/filtration. No difference was found in the incidence of bleeding (40% vs. 33.3%) which was defined as red blood cell transfusion ${\geq}5$ units, reoperation, or intentional delayed closure. The incidence of mediastinitis (2.0% vs. 0%), ventilator ${\geq}24$ hours (4.0% vs. 2.8%), atrial fibrillation (18.0% vs. 25.0%), mean intensive care unit stay (34.5 hours vs. 38.8 hours), and median hospital stay (8 days vs. 7 days) did not differ, either. Conclusion: AVR combined with additional aortic or root replacement showed an excellent outcome and recovery course equivalent to that after isolated AVR.

Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm$^{(R)}$ Guided Methods

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.3
    • /
    • pp.204-209
    • /
    • 2012
  • Objective : The authors performed a retrospective study to assess the accuracy and clinical benefits of a navigation coupled with O-arm$^{(R)}$ system guided method in the thoracic and lumbar spines by comparing with a C-arm fluoroscopy-guided method. Methods : Under the navigation guidance, 106 pedicle screws inserted from T7 to S1 in 24 patients, and using the fluoroscopy guidance, 204 pedicle screws from T5 to S1 in 45 patients. The position of screws within the pedicle was classified into four groups, from grade 0 (no violation cortex) to 3 (more than 4 mm violation). The location of violated pedicle cortex was also assessed. Intra-operative parameters including time required for preparation of screwing procedure, times for screwing and the number of X-ray shot were assessed in each group. Results : Grade 0 was observed in 186 (91.2%) screws of the fluoroscopy-guided group, and 99 (93.4%) of the navigation-guided group. Mean time required for inserting a screw was 3.8 minutes in the fluoroscopy-guided group, and 4.5 minutes in the navigation-guided group. Mean time required for preparation of screw placement was 4 minutes in the fluoroscopy-guided group, and 19 minutes in the navigation-guided group. The fluoroscopy-guided group required mean 8.9 times of X-ray shot for each screw placement. Conclusion : The screw placement under the navigation-guidance coupled with O-arm$^{(R)}$ system appears to be more accurate and safer than that under the fluoroscopy guidance, although the preparation and screwing time for the navigation-guided surgery is longer than that for the fluoroscopy-guided surgery.

Iatrogenic Large Esophageal Perforation Caused by Sengstaken-Blackmore Tube (식도 정맥류 출현 환자에서 Sengataken-Blackmore관에 의한 의인성 거대 흉부식도 파열)

  • 윤영철;조광현;권영민;전희재;최강주;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.36 no.1
    • /
    • pp.51-54
    • /
    • 2003
  • This patient was an 53-year-old man who had undergone Sengstaken-Blackmore tube insertion for esophageal varix bleeding. Two days after Sengstaken-Blackmore tube insertion, he developed severe left hemothorax and was transferred to our hospital. The esophagoscopic findings revealed a large perforation lengthening 8-cm in the intrathoracic esophagus. A left thoracotomy was performed 33 days after the injury due to repeated varix bleedings and poor conditions. An 8-cm longitudinal perforation of the intrathoracic esophagus with gross suppurative empyema was found. Primary repair and esophageal exclusion was performed 2cm proximal and distal to the perforation, using rows of nonabsorbable staplers(TA stapler 60 $\times$ 4.8) and large bore thoracostomy tubes were placed for local drainage. Six days after intrathoracic esophageal exclusion, an esophagogram revealed a leakage at just above the proximal stapling site. A cervical esophageal exclusion was performed using the same method. One hundred thirty seven days after exclusion operation for the intra-thoracic esophageal perforation, the patient was able to eat per orally without any secondary esophageal reconstructive surgery.

Acute Diaphragmatic Injuries Associated with Traumatic Rib Fractures: Experiences of a Major Trauma Centre and the Importance of Intra-Pleural Assessment

  • Hussain, Azhar;Hunt, Ian
    • Journal of Chest Surgery
    • /
    • v.54 no.1
    • /
    • pp.59-64
    • /
    • 2021
  • Background: Diaphragmatic injuries following blunt or penetrating thoraco-abdominal trauma are rare, but can be life-threatening. Rib fractures are the most common associated injury in patients with a traumatic diaphragmatic injury (TDI). We hypothesized that the pattern of rib fracture injuries could dictate the likelihood of acute TDIs. Methods: A retrospective study was carried out between April 2014 and October 2018 to analyze patients with TDIs and rib fractures at a major trauma center in London, United Kingdom. Results: Over the study period, 1,560 patients had rib fractures, of whom 14 had associated diaphragmatic injuries. Left-sided diaphragmatic injuries were found in 8 patients (57%). A significant proportion of the rib fractures were located posterolaterally (44.9%). The highest frequency of fractures was found in ribs 5-10, which accounted for 74% of all the fractures. Ten patients underwent surgery, of whom 7 were diagnosed with a diaphragmatic injury intraoperatively after video-assisted thoracoscopic surgery assessment of the pleural cavity. Two patients died due to severe injuries of other organs and the remaining 2 patients were managed conservatively. Conclusion: Our series of patients demonstrates a relationship between significant rib fractures and diaphragmatic injuries in trauma patients, and the diagnostic difficulties in identifying the condition. We found that the location of the rib fractures and the pattern of injury in patients with TDIs were much lower and posterolateral in the chest wall without a preference for laterality. We suggest using a thoracoscope in patients undergoing chest wall surgery post-trauma to aid in diagnosing this condition.

Clinical Outcome of Emergency Coronary Artery Bypass Grafting after Failed Percutaneous Transluminal Coronary Angioplasty (경피적 관상동맥 성형술의 실패에 의해 발생한 응급환자의 임상경과)

  • Kim, Do-Kyun;Yoo, Kyung-Jong;Youn, Young-Nam;Yi, Gi-Jong;Lee, Sak;Chang, Byung-Chul;Kang, Meyun-Shick
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.209-214
    • /
    • 2007
  • Background: Failed percutaneous transluminal coronary angioplasty (PTCA) is occasionally required for emergency coronary artery bypass grafting (CABG). The aim of this study was to assess the outcome of patients receiving emergency CABG after failed PTCA. Material and Method: Between May 1988 and May 2005, 5712 patients underwent PTCA, where 84 (1.4%) failed. 27 patients underwent emergency CABG after failed PTCA. The mean age was $63.7{\pm}8.9\;(46{\sim}80)$ years, with 14 male patients (51.9%). Result: All patients underwent emergent surgical revascularization within 6 hours. 22 patients underwent conventional CABG and 5 underwent off-pump CABG. The causes of PTCA failure were coronary obstruction due to new thrombi formation during the procedure (n=4), coronary dissection (n=17), coronary artery rupture (n=3) and 3 due to other causes. The rate of in-hospital operative mortality after emergent operation was 18.5% (5/27). A univariate analysis revealed that patients who died more often had left anterior descending artery disease, a preprocedural shock status, postoperative use of multiple isotropics and postoperative use of intra-aortic balloon pump. The mean follow up duration was $53.6{\pm}63.4$ months. Conclusion: Although PTCA is known to be life saving, there is still a high risk for morbidity and mortality following emergency CABG after failed PTCA, despite the advancement in PTCA techniques. This result will help identify and more effectively treat patients selected for PTCA when emergency CABG is required.

Early Results of Aortic Valve-sparing Procedures in Patients with Annuloaortic Ectasia (대동맥륜대동맥확장(Annuloaortic Ectasia) 환자에서 대동맥판막을 보존하면서 시행된 대동맥근부 및 상행대동맥 치환술의 단기 성적)

  • Sung Kiick;Park Kay-Hyun;Lee Young Tak;Jun Tae-Gook;Yang Ji-Hyuk;Kim Su Wan;Kim Jin Sun;Cho Sung Woo;Kim Si Wook;Choi Jin Ho;Park Pyo Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.483-488
    • /
    • 2005
  • Aortic valve-sparing procedures could reduce valve-related morbidity, but may increase operative risks; therefore, these procedures could not be performed routinely. We attempted to find out the early results while focusing on the operative risks associated with these procedures in our hospital. Material and Method: From May 1996 to July 2003, 26 patients underwent these procedures including 15 patients with Marfan syndrome and 1 patient with Behcet disease. There were 17 men and 9 women with mean age of $37.9\pm19.2$ years (range: 6 months-74 years). Ten patients had ascending aortic dissection, 18 patients had more than moderate degree of aortic valve insufficiency (AI). Two types of valve-sparing procedures were performed: valve reimplantation in 14 and root remodeling in 12 patients. Associated procedures were performed as follows: aortic valve plasty in 6, mitral valve plasty in 5, hemi-arch replacement in 4, total arch replacement in 2, coronary artery bypass surgery in 1 and Maze procedure in 1 patient(s). Result: In four patients, valve-sparing procedures were converted to Bentall procedures during operation. Including these patients, there was no operative deaths, 3 patients underwent re-operation due to bleeding, 1 patient had permanent pacemaker. The median duration of ICU stay was 45.5 hours, the median duration of hospital stay was 10.5 days. In 22 patients excluding 4 converted patients, intraoperative transesophageal echocardiogram (TEE) showed less than mild degree of AI in all except one who had not received intra-operative TEE in the beginning and showed moderate degree of AI at discharge. The mean duration of follow-up was $21.2\pm27.4$ months. All patients were alive except one who died during other departmental surgery. In 3 patients, more than moderate degree of AI was recurred, but there were no reoperation. Conclusion: Aortic valve-sparing procedures could be performed relatively safely in selected patients who had annuloaortic ectasia.

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.

Aortopulmonary Window (대동맥폐동맥창)

  • Kim Dong-Jin;Min Sun-Kyung;Kim Woong-Han;Lee Jeong-Sang;Kim Yong-Jin;Lee Jeong-Ryul
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.275-280
    • /
    • 2006
  • Background: Aortopulmonary window (APW) is a very rare congenital heart anomaly, often associated with other cardiac anomalies. It causes a significant systemic to pulmonary artery shunt, which requires early surgical correction. Accurate diagnosis and surgical correction will bring good outcomes. The purpose of this study was to describe our 20-year experience of aortopulmonary window. Material and Method: Between March 1985 and January 2005, 16 patients with APW underwent surgical repair. Mean age at operation was $157.8{\pm}245.3$ ($15.0{\sim}994.0$) days and mean weight was $4.8{\pm}2.5$ ($1.7{\sim}10.7$) kg. Patent ductus arteriosus (8), atrial septal defect (7), interruptedaortic arch (5), ventricular septal defect (4), patent foramen ovate (3), tricuspid valve regurgitation (3), mitral valve regurgitation (2), aortic valve regurgitation (1), coarctation of aorta (1), left superior vena cavae (1), and dextrocardia (1) were associated. Repair methods included 1) division of the APW with primary closure or patch closure of aorta and pulmonary artery primary closure or patch closure (11) and 2) intra-arterial patch closure (3). 3) Division of the window and descending aorta to APW anastomosis (2) in the patients with interrupted aortic arch or coarctation. Result: There was one death. The patient had 2.5 cm long severe tracheal stenosis from carina with tracheal bronchus supplying right upper lobe. The patient died at 5th post operative day due to massive tracheal bleeding. Patients with complex aortopulmonary window had longer intensive care unit and hospital stay and showed more morbidities and higher reoperation rates. 5 patients had reoperations due to left pulmonary artery stenosis (4), right pulmonary artery stenosis (2), and main pulmonary artery stenosis (1). The mean follow-up period was $6.8{\pm}5.6$ (57.0 days$\sim$16.7 years)years and all patients belonged to NYHA class 1. Conclusion: With early and prompt correction of APW, excellent surgical outcome can be expected. However, optimal surgical method needs to be established to decrease the rate of stenosis of pulmonary arteries.