• 제목/요약/키워드: Intimal Hyperplasia

검색결과 35건 처리시간 0.018초

Three-Dimensional Flow Simulations of End-to-Side Vascular Anastomoses : Flow Dynamic Aspect on Preferential Development of Intimal Hyperplasia or Thrombosis

  • Kim, Young H.;Krishnan B.Chandran
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권3호
    • /
    • pp.253-258
    • /
    • 1994
  • Three-dimensional steady and pulsatile flows in an end-to-side anastomosis were investigated using a finite difference method in order to understand the flow dynamics in the preferential development of distal anastomotic intimal hyperplasia or thrombosis. Steady flow results revealed that a double helical vortex was formed in the host artery and flow recirculations near toe find heel regions were restricted due to the secondary flow. Oscillating wall shear stress with significant secondary flow might be flow dynamic reason of developing intimal hyperplasia or thrombosis near the anastomotic region.

  • PDF

혈류의 유동이 혈관-인조혈관 접속부 혈관 내막 세포증식에 미치는 영향 (Hemodynamic Effects on Artery-Graft Anastomotic Intimal Hyperplasia)

  • 이계한
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권2호
    • /
    • pp.143-150
    • /
    • 1994
  • Wall shear rate or stress is believed to be a major hemodynamic variable influencing atherosclerosis and artery-graft anastomic intimal hyperplasia. The purpose of this study is to verify the effects of radial wall motion, artery-graft compliance and diameter mismatch, and impedance phase angle on the wall shear rate distribution near an end-to-end artery-graft anastomosis model. The results show that radial wall motion of the elastic artery model lowers the mean wall shear rates under pulsatile flow condition by 15 to 20 % comparing to those under steady flow condition at the same mean flow rate. Impedance phase angle seems to have small effects on the mean and amplitude of the wall shear rate distribution. In order to study the effects of compliance and diameter mismatch on the wall shear rates, two models are studied-Model I has 6% and Model I has 6% and Model II has 11% smaller graft diameter. Divergent geometry caused by diameter mismatch near the distal sites reduces the mean wall shear rates significantly, and this low shear region is believed to be prone to intimal hyperplasia.

  • PDF

혈관이식술 후 내막과다증식에 대한 Epigallocatechin-3-Gallate의 효과 (The Effect of Epigallocatechin-3-Gallate on Intimal Hyperplasia after Vascular Grafting)

  • 박한기;송석원;이미희;박종철;주현철;장병철;박영환
    • Journal of Chest Surgery
    • /
    • 제40권4호
    • /
    • pp.256-263
    • /
    • 2007
  • 배경: 혈관내막과다증식은 혈관평활근세포가 내막에서 과다증식하여 나타나며, epigallocatechin-3-gallate(EGCG)는 혈관평활근세포의 증식을 억제하는 효과가 있는 것으로 알려져 있다. 따라서 EGCG는 혈관내막과다증식을 억제할 수 있을 것으로 생각된다. 대상 및 방법: 다른 농도의 EGCG를 포함한 배양 배지에서 인간제대정 맥내피세포(HUVEC)와 쥐대동맥평활근세포(RASMC)를 배양하고, 세포증식과 이동속도를 측정하였다. 20마리의 개의 양측 경동맥에 자가경정맥을 이식하였으며, 실험군(n=10)에 대해서는 정맥도관을 이식 전 30분간 EGCG용액에 보관하였으며, 이식 후 300mM의 EGCG를 혈관주위에 도포하였다. 6주 후에 경정맥이식편의 내막과 중간막의 두께를 측정하였다. 결과: 내피세포와 혈관평활근세포의 증식은 EGCG에 의해 억제되었다. 혈관평활근세포의 이동성은 EGCG에 의해 억제되었으나, 내피세포의 이동성은 영향을 받지 않았다. 동물실험 결과 대조군에 비해 EGCG군에서 내막의 두께가 얇았으며(p<0.05), 중간막의 두께는 두 군간에 차이가 얼었고, 내막/중간막의 두께비는 EGCG군에서 낮게 관찰되었다(p<0.05). 결론: EGCG는 혈관수술 후 혈관내막과다증식을 억제하는 효과가 있으며, 이는 혈관평활근세포의 증식 및 이동을 억제하여 효과를 나타낸다고 생각된다. 따라서 EGCG는 혈관내막과다증식을 예방하는 치료에 효과적으로 사용될 수 있을 것으로 생각된다.

The Wall Shear Rate Distribution Near an End-to-End Anastomosis : Effects of Graft Compliance and Size

  • Rhee, Kye-Han
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제1권1호
    • /
    • pp.41-47
    • /
    • 2003
  • The patency rates of small diameter vascular grafts are disappointing because of the formation of thrombus and intimal hyperplasia. Among the various factors influencing the success of graft surgery, the compliance and the size of a graft are believed to be the most important physical properties of a vascular graft. Mismatch of compliance and size between an artery and a graft alters anastomotic flow characteristics, which may affect the formation of intimal hyperplasia. Among the hemodynamic factors influencing the development of intimal hyperplasia, the wall shear stress is suspected as the most important one. The wall shear stress distributions are experimentally measured near the end-to-end anastomosis models in order to clarify the effects of compliance and diameter mismatch on the hemodynamics near the anastomosis. The effects of radial wall motion, diameter mismatch and impedance phase angle on the wall shear rate distributions near the anastomosis are considered. Compliance mismatch generates both different radial wall motion and instantaneous diameter mismatch between the arterial portion and the graft portion during a flow cycle. Mismatch in diameter seems to be affecting the wall shear rate distribution more significantly compared to radial wall motion. The impedance phase angle also affects the wall shear rate distribution.

  • PDF

관상동맥우회 이식편으로서의 우위대망동맥의 조직학적 특징 (Histological Characteristics of Right Gastroepiploic Artery for Coronary Artery Bypass Graft)

  • 이현우;송현;유동곤;임한중;이재원;송명근
    • Journal of Chest Surgery
    • /
    • 제32권10호
    • /
    • pp.883-890
    • /
    • 1999
  • Long term patency of arterial graft has been better than venous graft and redo coronary artery bypass grafting has been increasing, therefore, there has been an increasing need for alternative arterial grafts except internal thoracic artery(ITA). Material and Method: Right gastroepiploic arteries(RGEA) were harvested from 100 patients who had received gastrectomy for gastric cancer or ulcer. ITAs were obtained from 10 patients undergoing coronary artery bypass grafting. The length of RGEA was measured from the pyloric ring. Items of the morphometric and histologic study at the pyloric ring and sites of the 10cm and 20cm RGEA from the pyloric ring were luminal diameter, intimal thickness, medial thickness, wall thickness, degree of intimal hyperplasia, intimal thickness, medial thickness, wall thickness, degree of intimal hyperplasia, intimal thickness index, medial thickness index, and the number of discontinuities of the internal elastic lamina. Similar items were applied to the proximal site of ITAs. Result: The length of RGEA was 23${\pm}$2.7cm(range 17∼31cm). Comparing the 20cm RGEA with ITA, intimal thickness, medial thickness, wall thickness, and degree of intimal hyperplasia did not show any difference(p>0.05). However, 20cm RGEA was greater than ITA at the luminal diameter, intimal thickness index, and the number thickness and wall thickness in each site of the RGEA(pyloric ring, 10cm, 20cm) decreased from the pyloric ring to the distal sites(p<0.05). The degree of intimal hyperplasia and the number of discontinuities of the internal elastic lamina did not show any difference between the pyloric ring and 10cm, however, those of 20cm were smaller than these sites(p<0.05). RGEA had more number of discontinuities of the internal elastic lamina and rich smooth muscle cells in the media than ITA. Conclusion: The length and diameter of RGEA is good enough to reach most of the coronary arteries. Moreover, long term patency of RGEA may be improved, if anastomosed in the distal site.

  • PDF

End-to-Side 혈관문합에서의 삼차원유동: 정상유동 및 맥류유동 (Three-Dimensional Flow in an End-to-Side Vascular Anastomosis: Steady and Pulsatile Flow)

  • 김영호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.115-118
    • /
    • 1994
  • Three-dimensional steady and pulsatile flows in an end-to-side anastomosis were investigated using a finite difference method in order to understand the flow dynamics in the preferential development of distal anastomotic intimal hyperplasia or thrombosis. Steady flow results revealed that a double helical vortex was formed in the host artery and flow recirculations near tow and heel regions were limited due to the secondary flow. Oscillating wall shear stress with significant secondary flow might be the flow dynamic reason of developing intimal hyperplasia or thrombosis.

  • PDF

유량 파형이 데이퍼형 인조혈관 유동에 미치는 영향 (The Effects of Flow Wave form on the Flow Characteristics in Tapered Vascular Grafts)

  • 이현철;석광원;전철완;이진;이영석;김성환
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권3호
    • /
    • pp.337-346
    • /
    • 1996
  • The patency of small size vascular grafts is poor, and the blood flow characteristics in the artery graft anastomosis are suspected as one of the important factors influencing intimal hyperplasia. Disturbed flow patterns caused by sixte and compliance mismatch generate unfavorable flow environment which promotes intimal thickening. Tapered vascular yuts are suggested in order to reduce sudden expansion near the anastomosis. The photochromic flow visualization method is used to measure the flout fields in the end-to-end anastomosis model under the carotid and femoral artery flow wave form. The results show that flow disturbance near the anastomosis is diminished in the tapered grafts comparing to the tubular graft. As the divergent ang1e decreases, we can reduce the low and oscillatory wall shear stress zone which is prone to intimal hyperplasia. The flow wave form effects the wall shear rate dis- tribution significantly. The steep deceleration and back flow in the femoral flow wAve form cause low mean wall shear rate and high oscillatory shear index.

  • PDF

Alkoxybenzylcyanoguanidine Analogs as a Novel Class of Inhibitors for Restenosis

  • Lee, Sun-Kyung;Yi, Kyu-Yang;Hwang, Sun-Kyung;Suh, Jee-Hee;Lee, Byung-Ho;Yoo, Sung-Eun
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권7호
    • /
    • pp.1003-1008
    • /
    • 2004
  • A novel class of alkoxybenzylcyanoguanidine analogs as the inhibitors of restenosis was discovered, which showed the inhibitory effects on angiotensin II-induced cell proliferation, determined by $[^3H]$thymidine incorporation method. The compound, N'-(4-nitrophenyl)guanidine analog 19, showed 62% inhibition of $[^3H]$thymidine incorporation at 1 ${\mu}M$ concentration. In addition, the compound 19 inhibited intimal thickening dose-dependently after balloon injury, which suggests the therapeutic potential for restenosis.