• Title/Summary/Keyword: Interruptions

Search Result 157, Processing Time 0.028 seconds

A Study on Minimization of Train Delays and Train Operation Interruptions by RF Transmission System. (RF 통신시스템을 이용한 열차 운행중단 및 열차 지연의 최소화에 관한 연구)

  • Lee, We-Jae;Kook, Kwaung-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1466-1472
    • /
    • 2008
  • To minimize the train operation interruptions and train exchanges, the RF transmission system is proposed. The current control room of the Seoul Metro has information of the train movement through the Total Traffic Control System, but it does not have information of the train itself, rail status, and other facilities' status. When some trouble occurs during train operation, the train crews should report the control room about the trouble and fix it. If the control room has exact information of the trouble, the expert in the control room can help the crews to fix the trouble swiftly and exactly. Since the crews are busy taking care of the trouble, they often miss to report the control room on time. The proposed RF transmission system relays the information of the train to the control room automatically in real time, and makes it possible to provide the passengers good service by reducing the train operation interruptions and train exchanges.

  • PDF

Interruptions, Unreasonable Tasks, and Quality-Threatening Time Pressure in Home Care: Linked to Attention Deficits and Slips, Trips, and Falls

  • Elfering, Achim;Kottwitz, Maria U.;Hafliger, Evelyne;Celik, Zehra;Grebner, Simone
    • Safety and Health at Work
    • /
    • v.9 no.4
    • /
    • pp.434-440
    • /
    • 2018
  • Background: In industrial countries, home care of community dwelling elderly people is rapidly growing. Frequent injuries in home caregivers result from slips, trips, and falls (STFs). The current study tests attentional cognitive failure to mediate the association between work stressors and STFs. Methods: A sample of 125 home caregivers participated in a questionnaire study and reported work interruptions, unreasonable tasks, quality-threatening time pressure, conscientiousness, attentional cognitive failures, and STFs. Results: In structural equation modeling, the mediation model was shown to fit empirical data. Indirect paths with attentional cognitive failures as the link between work stressors and STF were all significant in bootstrapping tests. An alternative accident-prone person model, that suggests individual differences in conscientiousness to predict attentional cognitive failures that predict more frequent work stressors and STFs, showed no significant paths between work conditions and STFs. Conclusion: To prevent occupational injury, work should be redesigned to reduce work interruptions, unreasonable tasks, and quality-threatening time pressure in home care.

Unified Reliability and Its Cost Evaluation in Power Distribution Systems Considering the Voltage Magnitude Quality and Demand Varying Load Model (전압 크기의 품질 및 전력수요 변동모델을 고려한 배전계통의 통합적인 신뢰도 및 비용 평가)

  • Yun, Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.705-712
    • /
    • 2003
  • In this paper, we propose new unified methodologies of reliability and its cost evaluation in power distribution systems. The unified method means that the proposed reliability approaches consider both conventional evaluation factor, i.e. sustained interruptions and additional ones, i.e. momentary interruptions and voltage sags. Because the three voltage quality phenomena generally originate from the outages on distribution systems, the basic and additional reliability indices are summarized considering the fault clearing mechanism. The proposed unified method is divided into the reliability evaluation for calculating the reliability indices and reliability cost evaluation for assessing the damage of customer. The analytic and probabilistic methodologies are presented for each unified reliability and its cost evaluation. The time sequential Monte Carlo technique is used for the probabilistic method. The proposed DVL(Demand Varying Load) model is added to the reliability cost evaluation substituting the average load model. The proposed methods are tested using the modified RBTS(Roy Billinton Test System) form and historical reliability data of KEPCO(Korea Electric Power Corporation) system. The daily load profile of the each customer type in domestic are gathered for the DVL model. Through the case studies, it is verified that the proposed methods can be effectively applied to the distribution systems for more detail reliability assessment than conventional approaches.

Reasons, Incidences, and Influencing Factors of Work Interruptions in Intensive Care Unit Nurses (중환자실 간호사에게 발생하는 업무 흐름 중단 이유와 발생빈도 및 영향요인)

  • You, Jung Eun;Lee, Eun Nam
    • Journal of muscle and joint health
    • /
    • v.27 no.3
    • /
    • pp.247-254
    • /
    • 2020
  • Purpose: This was a descriptive observational study examining the reasons for, frequency of, and factors affecting work interruption among intensive care unit (ICU) nurses. Methods: Convenience sampling was used to recruit 46 regular nurses who had been working in an ICU at D tertiary hospital in B metropolitan city for at least six months. To measure the degree of work interruption, this study revised a tool used by Brixey et al. (2007) for analyzing the type of work interruption. Results: A total of 1,787 work interruptions occurred during 368 hours of observation, i.e., at an average of 4.85 times per hour. Communication-related factors caused work interruption most frequently, followed by environmental, work-related, and personal factors. As for the work-related characteristics of nurses, participants experienced work interruption more frequently while working on weekdays, when the medical staff were stationed, than on weekends. Conclusion: ICU nurses experienced work interruption frequently. With the health care system expected to become more complicated in the future, efforts should be made to reduce unnecessary work interruptions to improve the operation efficiency of ICUs.

A study on the algorithm for Digital Control System with intermittant computer interruptions and its simulation (컴퓨터의 간헐적 차단시 디지탈제어시스템의 알고리즘 연구와 시뮬레이션)

  • Jang, S.Wh.;Du, P.S.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.885-887
    • /
    • 1991
  • A mathematical model under intermittant computer interruptions and its simulation results are presented. As a reasult have simulated for example to digital PID controller presented by Salama, it occured transient phenomena intermittant computer interruption on real time. That is, it presented reason that, is occured instantaneous vibration phenomena when digital computer is interrupted intermittantly

  • PDF

A Comparative Study for Reliability of Single and Radial Power Distribution System considering Momentary Interruption (단일루프 배전계통과 방사상 배전계통의 순간정전을 고려한 신뢰도 비교 연구)

  • Lee, Hee-Tae;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1270-1275
    • /
    • 2009
  • The structure of a power distribution system will change in a loop configuration such as in the case of a smart grid. If power distribution system changes radial to loop form, the structure may have to be changed significantly. Therefore, we analyzed the reliability indices and calculated a CIC(Customer Interruption Cost) for the loop power distribution system. The power distribution system reliability depends on the protection scheme. This study is applied to the current protection scheme method and is compared with each model. When the CIC was evaluated, most studies performed calculations only for sustained interruptions. However, in actuality, momentary interruption frequencies occurred more than sustain interruptions. Thus, it is occurred the CIC additively. Therefore, we evaluated a CIC including momentary interruption, for each model, and then compared with MAIFI(Momentary Average Interruption Frequency Index)

The Study of In Clustering Effects in InGaN/GaN Multiple Quantum Well Structure (InGaN/GaN 다중 양자우물 구조에서의 In 응집 현상의 연구)

  • 조형균;이정용;김치선;양계모
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.636-639
    • /
    • 2001
  • InGaN/GaN multiple quantum wells (MQWs) grown with various growth interruptions between the InGaN well and GaN barrier by metal-organic chemical vapor deposition were investigated using photoluminescence, high-resolution transmission electron microscopy, and energy filtered transmission electron microscopy (EFTEM). The luminescence intensity of the MQWs with growth interruptions is abruptly reduced compared to that of the MQW without growth interruption. Also, as the interruption time increases the peak emission shows a continuous blue shift. Evidence of indium clustering is directly observed both by using an indium ratio map of the MQWs and from indium composition measurements along an InGaN well using EFTEM. The higher intensity and lower energy emission of light from the MQW grown without interruption showing indium clustering is believed to be caused by the recombination of excitons localized in indium clustering regions and the increased indium composition in these recombination centers.

  • PDF

Investigation of the Impact of Voltage Sags and Temporary Interruptions on 3-Phase Induction Motors (배전계통 순간전압강하 및 순간정전이 3상 유도전동기에 미치는 영향 검토)

  • Kang, Bong-Seok;Kim, Jae-Chul;Moon, Jong-Fil;Yun, Sang-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.106-109
    • /
    • 2003
  • This paper describes the various characteristics of voltage sags and temporary interruptions which can affect the functions of 3-phase induction motors. These assorted characteristics include motor speed loss, voltage recovery, motor reacceleration, and transient characteristics. An experimental study on induction motor behavior was also carried out to confirm these impacts. Besides, sequential voltage sags of short duration were considered for this paper. The results show that the occurrence of the second voltage sag after the first one may affects the induction motor adversely.

  • PDF

The effects of the self-directed career management on the career success - Focused on the career interruption - (자기주도적 경력과 경력성공 간 관계 연구 -경력전략으로서의 경력단절을 중심으로-)

  • Suh, Yong-Han
    • Management & Information Systems Review
    • /
    • v.35 no.2
    • /
    • pp.13-26
    • /
    • 2016
  • The career management concept is changing rapidly in the career management field in recent years. It becomes very difficult to have a lifetime employment within the same firm. As there is career-interruption that is pervasive phenomenon in the career management area, many academics and practitioners have been interested in it. The purpose of this study was to examine the influence of career-interruptions as the effective career strategy of the self-directed career development on career strategy(career-interruptions frequency, career opportunities searching and career success (workers' wages). To test the effects of the self-directed career management, data were divided into two groups including self-directed career management group (n=210) and general career management group (n=191) based on whether career-interruptions are voluntary or not. The results showed that the self-directed career development attitude and career success were significantly different depending on worker's self-directed career management and general career management group.

  • PDF

Questionnaire Development and Survey & Analysis for the Calculation of the Domestic Industrial Customer Interruption Costs (산업수용가의 정전비용 산출을 위한 조사 분석 연구)

  • 박충열;남기영;허창수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.165-170
    • /
    • 2004
  • This paper presents summary results of direct interview survey of Korean industrial customers conducted to evaluate the direct and short duration interruption costs resulting from local random electrical supply interruptions. The cost is evaluated using the questionnaires authors designed, which are mainly on the experience or preparatory actions consumers predicted they would take. Economic evaluation of reliability that traditionally takes into account duration and frequency of interruption does not accurately reflect the lost value or economic impacts of industrial customer, especially large size, caused by any kind of interruption. So, to imply the substantial difference in costs incurred by different customer group, the authors apply the international standards, i.e. IEC, IEEE, to the analysis on the interruption costs.