• 제목/요약/키워드: International entrance

검색결과 154건 처리시간 0.02초

Risk Analysis According to the Installation of Fire Doors on Direct Stairs in the Event of a Fire in an Old Apartment (노후 아파트 화재 시 직통계단의 방화문 설치 여부에 따른 위험성 분석)

  • Lee, Sang Im;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • 제7권4호
    • /
    • pp.869-878
    • /
    • 2021
  • This study is a study on 11-story apartments that increase the event of fires in old apartments where building-related laws and regulations are not retroactively applied. As a result of analyzing the risk of installing fire doors in Improvement Scenario 2-4, assuming that fire doors are installed as basic scenario 1 in the existing situation where fire doors are not installed at the entrance of direct stairs. In basic scenario 1, the visible distance to the entrance of the direct staircase due to the spread of smoke was 260 seconds. Improvement scenarios 3 to 4 with fire doors installed open 300 seconds after the fire was recognized, and when the fire doors were installed at the entrance of the direct stairs, the visibility to the entrance of the statistics team was less than 600 seconds. In this case, the visibility was 600 seconds at the time of installation of the fire door, and scenarios 3 to 4 increased 56.6% compared to scenario 1, lowering the risk of evacuation by more than 50%. In order to eliminate the risk of non-installation of direct statistical groups that increase the risk of smoke spread, building-related laws such as the Fire Fighting Act shall be retroactively applied when installing a direct stairway entrance or balcony folding evacuation system. The improvement caused by the installation of fire doors has numerically proven the necessity of fire doors during evacuation, and the importance of maintaining fire doors can be grasped.

Effect of Tunnel Entrance Shape of High Speed Train on Aerodynamic Characteristics and Entry Compression Wave (고속전철의 터널입구 형상이 공력특성 및 터널입구 압축파에 미치는 영향)

  • Jeong, Soo-Jin;Kim, Woo-Seung;Zhu, Ming
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제12권6호
    • /
    • pp.111-118
    • /
    • 2004
  • The work presented in this paper concerns the aerodynamic characteristics and compression wave generated in a tunnel when a high speed train enters it. A large number of solutions have been proposed to reduce the amplitude of the pressure gradient in tunnels and some of the most efficient solutions consist of (a) addition ofa blind hood, (b) addition of inclined part at the entrance, and (c) holes in the ceiling of the tunnel. These are numerically studied by using the three-dimensional unsteady compressible Euler equation solver with ALE, CFD code, based on FEM method. Computational results showed that the smaller inclined angle leads to the lower pressure gradient of compression wave front. This study indicated that the most efficient slant angle is in the range from $30^{\circ}$ to $50^{\circ}$. The maximum pressure gradient is reduced by $26.81\%$ for the inclined angle of $30^{\circ}$ as compared to vertical entry. Results also showed that maximum pressure gradient can be reduced by $15.94\%$ in blind hood entry as compared to $30^{\circ}$ inclined tunnel entry. Furthermore, the present analysis showed that inclined slant angle has little effect on aerodynamic drag. Comparison of the pressure gradient between the inclined tunnel hood and the vertical entry with air vent holes indicated that the optimum inclined tunnel hood is much more effective way in reducing pressure gradient and increasing the pressure rise time.

A Study on the Environmental Design Factors of Children's Park Access Area - A Survey Focusing on the Perceptions of Professional Groups - (어린이공원 주변공간의 환경계획요인에 관한 연구 - 전문가 의식조사를 중심으로 -)

  • Bae, Yeonhee;Byun, Gi-dong;Ha, Mikyoung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • 제34권5호
    • /
    • pp.71-78
    • /
    • 2018
  • This study seeks to identify elements of spatial planning for areas surrounding children's parks in order to improve child safety. It will identify different aspects of child safety and extract elements of safety planning for the areas surrounding children's parks from a literature review of both domestic and international research. The study classifies the space between one's residence and the children's park as either a "means of access", such as pedestrian walkways and streets, or a "boundary", which consists of the entrance, exit, and fences; then, the derived safety planning elements were categorized in accordance with this classification. In order to ensure the validity of the planning elements, an expert survey was conducted of environment planners who specialize in the palnning and designing of residential area as well as government employees who are in direct charge of managing children's parks. The survey findings were as follow. First, the pedestrian walkway(means of access) near the park is the most crucial factor in regards to the safety of children, followed by the entrance and exit(boundary), fency(boundary), and streets (means of access), in descending order of importance. Thus, improving the safety of the pedestrian walkway should be considered first and foremost, and it should precede improving the surrounding streets. Second, an investigation of the need for safety devices near the children's park showed that securing visibility, through the installation of an illegal parking prevention device, is imperative. Illegal parking near children's parks poses a grave risk to pedestrian safety and demands immediate action. Furthermore, a section of streets within 300m of the park entrance should be designated as a children protection zone, in addition to the designation of school zones near elementary schools.

Simulation Results for Performance and Coverage Prediction of dLoran (dLoran 성능 커버리지 예측 시뮬레이션)

  • Seo, Ki-Yeol;Han, Young-Hoon;Kim, Young-Ki;Park, Sul-Gee
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 한국항해항만학회 2017년도 추계학술대회
    • /
    • pp.199-200
    • /
    • 2017
  • In order to meet the international performance requirements for eLoran testbed operation, it is necessary to measure ASF (Additional Secondary Factor) of vessel's route as well as differential correction and the provision using differential Loran (dLoran) station operation. According to HEA (Harbor Entrance and Approach) performance of the IMO, the position accuracy should be within 10meters. Therefore this paper presents the possibility to meet the position accuracy of the IMO HEA through simulation results.

  • PDF

A Study of Spraying Curing Compound for Concrete Pavement Considering Environmental Condition in Tunnel (터널내 환경을 고려한 콘크리트 포장의 양생제 살포기준 연구)

  • Ryu, SungWoo;Kwon, OhSun;Song, GeoRuemSoo;Lee, MinKyung;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • 제16권3호
    • /
    • pp.51-57
    • /
    • 2014
  • PURPOSES : This study is to suggest tunnel length to spray curing compound, based on the field tests. METHODS : At first field test, length from the entrance of tunnel to wet wall was checked by visual survey. The second and third test, various sensors were installed in concrete or in tunnel, such as RH sensor, temperature sensor, portable weather station and etc.. And also, test for bleeding and retaining water of concrete were conducted to evaluate environmental effect on concrete pavement. RESULTS : The result of the field experiment for tunnel length to spray curing compound indicates that length changes depending on tunnel length, season, and location. Environmental condition of a short tunnel was not much different between location near entrance and at center of tunnel. However, in case of a medium and long tunnel, effect of outside environmental condition decreased, when location moved into tunnel center of it. CONCLUSIONS : From the testing results, it can be proposed that optimum tunnel length to spray curing compound is 60m for a medium and long tunnel, and whole length for a short tunnel.

A Study on Types of Outdoor Living Environments for the Elderly (노인주거시설의 외부공간 유형에 관한 연구)

  • Lee, Shi-Young;Park, Bo-Shin;Hong, Kwang-Ho;Shim, Joon-Young
    • Journal of Environmental Science International
    • /
    • 제16권12호
    • /
    • pp.1383-1392
    • /
    • 2007
  • The purpose of this study is to provide suitable outdoor spaces for Korean elderly, examining characteristics and types of existing outdoor spaces and presenting design guideline of outdoor space for elderly. To do this, this study examined previous research papers and scholastic writings, related to elderly housing, and analyzed twelve cases of elderly housing complex. Additionally evaluation of usage pattern and physical trace carried out on twelve cases. As a result, first, the study showed that outdoor spaces for elderly were classified 5 types; entrance area of housing complex, building entrance area, outdoor living area, in & outdoor neutral area, and parking lots. Outdoor living area is subdivided into residents' public space, green space, health & sports space and landscape space. Characteristics of outdoor space are deeply related to safety, amenity, recognition and efficiency. Second, types of outdoor space in elderly facilities are very limited in verity, just facilitating with rest space, sport space, and garden space. Third, from a standpoint of barrier-free-design, twelve cases are not carefully concerning about outdoor space for elderly.

Numerical Investigation on Hydrodynamic Characteristics of a Centrifugal Pump with a Double Volute at Off-Design Conditions

  • Shim, Hyeon-Seok;Kim, Kwang-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권3호
    • /
    • pp.218-226
    • /
    • 2017
  • Severe radial thrust under off-design operating conditions can be a harmful factor for centrifugal pumps. In the present work, effects of geometry of a double volute casing on the hydrodynamic performance of a centrifugal pump have been investigated focusing on off-design conditions. Three-dimensional steady Reynolds-averaged Navier-Stokes analysis was carried out by using shear stress transport turbulence model. Numerical results for the hydrodynamic performance of the centrifugal pump were validated compared with experimental data. The hydraulic efficiency and radial thrust coefficient were used as performance parameters to evaluate the hydrodynamic characteristics of the centrifugal pump. The cross-sectional area ratio of the volute casing, the expansion coefficient of the rib structure, the distance between the rib starting point and volute entrance, and radius and width of the volute entrance, and length of the rib structure, were selected as geometric parameters. Results of the parametric study show that the performance parameters are significantly affected by the geometric variables and operating conditions. Optimal configurations of the double volute casing based on the design of experiments technique show outstanding performance in terms of the efficiency and radial thrust coefficient.

Comparative Study on Difference in Driver's Workload between Driving Simulator and Field Driving in Tunnel, Highway (드라이빙 시뮬레이터 주행과 현장주행시 운전자 반응 비교 연구)

  • Kim, Hyun Jin;Kim, Ju Young;Choi, Gyeong Im;Ju, Che Hong;OH, Cheol
    • International Journal of Highway Engineering
    • /
    • 제19권6호
    • /
    • pp.139-145
    • /
    • 2017
  • PURPOSES : This study analyzed the difference in a driver's workload between using a driving simulator and field driving in tunnel, highway. METHODS : Based on the literature review, it was found that a driver's workload could be quantified using biosignals. This study analyzed the biosignal data of 30 participants using data collected while they were using a driving simulator and during a field test involving tunnel driving. Relative energy parameter was used for biosignal analysis. RESULTS : The driver's workload was different between the driving simulator and field driving in tunnels, highway. Compared with the driving simulator test, the driver's workload exhibited high value in field driving. This result was significant at the 0.05 level. The same result was observed before the tunnel entrance section and 200 m after the entrance section. CONCLUSIONS : This study demonstrates the driving simulator effect that drivers feel safer and more comfortable using a driving simulator than during a field test. Future studies should be designed considering the result of this study, age, type of simulator, study site and so on.

Design and Implementation of the EEIS Considering the Load of DB Server

  • Kim, Chang-Geun;Park, Byeong-Jin;Tack, Han-Ho
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제3권1호
    • /
    • pp.37-43
    • /
    • 2003
  • Current Internet system of the entrance exam information to the university that is depending on searching key to solve the overloaded problem in the network and DB server or other tools to support HTML edit, haven't satisfied user's wants by supplying uniformed searching system. So this thesis will establish EEIS(Entrance Examination Information System) to prevent database overload phenomena when many users request a great amount of data at the same time and improve the decrease of speed and overload problem in DB server. EEIS playa role of bridge between outside client and DB server by placing VVS(Virtual View Server) between web server and DB server. By that method this system give users several usefulness in convenience and variety by supplying realtime data searching function to user. EEIS also give inner system manager more efficiency and speed in control the management system by solving those problem. This system is design and implementation to satisfy user's desire and give them more convenience and bring up the confidence of university that adopt this system at the end.

Comparative Analysis on Domestic and Overseas Design Guidelines for Aging in place (지속적 거주(Aging in place)를 위한 국내·외 주택설계지침의 비교)

  • Kim, Hye-Shin;Park, Soobeen
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • 제35권9호
    • /
    • pp.19-28
    • /
    • 2019
  • Domestic and international laws and regulations on design of residential environment are adopted, revised and supplemented to solve the problems such as access, safety and privacy in the residential space of the elderly and the disabled. This study is an comparative analysis of Korea and Japan, USA, UK laws and regulations on environment design by literature review. The purpose of this study is to present the basic materials required for development of the standard that would supports the undiscriminatory physical environment for the socially weak who are experiencing aging and disability, due to the restricted scope of entrance, bathroom and kitchen spaces with high frequency of safety accident. The results of this study are as follows. (1) Design guidelines on residential environment were compared under five residential factors for aging in place: safety, accessibility, amenity, usability and privacy. (2) The guidelines of each country applied to the entrance, bathroom and kitchen space were compared. (3) The results showed present guidelines should be completed with 'safety', 'accessibility', 'amenity', 'usability' and 'privacy' for Aging in place.