• Title/Summary/Keyword: Internal standards

Search Result 487, Processing Time 0.025 seconds

Research on Standards for Protection against Electric Shock in Global Technical Regulations of Fuel Cell Vehicle (연료전지 자동차 세계기술규정의 감전보호기준 연구)

  • HwangBo, Cheon;Lee, Kyu-Myong;You, Kyeong-Jun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.3
    • /
    • pp.167-183
    • /
    • 2010
  • This paper analyzes the backgrounds of the standards for protection against electric shock in Global Technical Regulations (GTR) of Fuel Cell Vehicle (FCV). Targets on research were high voltage criteria, safety current, isolation and grounding resistance, time limitation, energy, adequate clearance, and test procedure. Based on human impedance and effect of current in IEC 60479-1, safety of human was examined. Then, isolation and grounding circuit model of FCV were analyzed theoretically. The results give several suggestions: touch voltage less than 25V, AC energy less than 0.0813J, separation considering middle finger length, grounding resistance less than $0.2\Omega$, maximum AC ground voltage of 1V (rms), and isolation resistance between earth and electrical chassis. In MATLAB/Simulink environment, error characteristics of isolation resistance measurement procedure using internal DC sources were analyzed under variations of internal resistance of voltmeter and isolation resistance.

A Study on the Survey of Each Country's Standards to Prevent Flashover of Housing Building (주거시설의 플래시오버 방지를 위한 각국의 내장재 기준 조사에 관한 연구)

  • Hun, Ye-Rim;Kim, Yoon-Seong;Lee, Byeong-Heun;Jin, Seung-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.44-45
    • /
    • 2021
  • In Korea, the risk of fire in buildings is increasing. Therefore, efforts are needed to reduce casualties and property damage. Accordingly, it is important to limit the flashover so that the fire inside the building does not expand to the outside. Flashover refers to the generation of upward airflow after the fire in the compartment, and when combustible gas accumulates in the upper part of the fire chamber and reaches about 500℃, explosive expansion combustion occurs inside the compartment. This can suppress flashover due to limitations on building interior materials. To this end, internal limitations are being implemented at home and abroad through standards related to internal materials. In this paper, we intend to secure basic data on domestic fire safety design by comparing domestic and foreign standards and reviewing the Japanese housing interior design manual.

  • PDF

An Experimental Study on Internal Temperature Changes of Type Ⅳ Cylinder according to Filling with Compressed Hydrogen Gas (압축수소가스 충전에 따른 타입 IV 용기의 온도 변화에 관한 실험적 연구)

  • Lee, Seung-Hoon;Kim, Youn-Gyu;Yoon, Kee-Bong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.644-647
    • /
    • 2009
  • In this paper, the study is researched for related safety standards having experiments concerning temperature changes in type IV cylinder of the Hydrogen fuel cell vehicle. Experiments were performed to acquire temperature data of type IV cylinder according to filling time. The experimental results are shown that internal temperatures of type Ⅳ vessel are over $85^{\circ}C$ at all measured points after 5 minutes at filling 35 MPa and the highest temperature is getting lower when the residual gases are more remained. Consequently, the safety standards need properly limited value through further study for filling flow rate and filling time.

  • PDF

A Study on the Insulation Characteristics of LED Lamps for Load and Street Lighting (LED 가로등 및 보안등기구의 절연특성 연구)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.546-551
    • /
    • 2009
  • In this paper, we studied insulation characteristics of LED lamps for load and street lighting. LED lamps can be divided into internal type and external type according to converter type. In this study, we analyzed technology standard, K(Electrical Appliances Safety Standards) and KS(Korean Industrial Standards) about insulation resistance for LED lamps for load and street lighting, and measured insulation resistances for each measured point. Mostly, insulation resistances were measured high more than regulation value but some measured points were measured badly. We expect that the results of these experiments would be helpful for electrical safety of LED lighting installation, manufacture, construction and maintenance.

A Simple Method for Generation of Homologous Internal Standards for Competitive PCR

  • Choi, Eu-Na;Hahn, Sung-Sik;Choi, Kyung-Hee;Na, Doe-Sun
    • BMB Reports
    • /
    • v.29 no.5
    • /
    • pp.481-483
    • /
    • 1996
  • In competitive PCR, which is used to quantify target DNA an internal standard is needed. Here we present a simple method to construct homologous competitive standards. The method, which is based upon deletion of a portion of the target DNA, does not require any additional primers. This is the simplest method developed thus far to construct a competitive standard. The whole procedure. from construction of a competitive standard to quantitation by PCR, can be completed within a single day.

  • PDF

A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete (초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구)

  • Baek, Young-Woon;Yuk, Tae-Won;Park, Dong-Soo;Kim, Han-Sol;Lee, Hang-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF

Need for Korean Industrial Standards (KS) for Acupuncture Needle (침의 한국산업규격(KS) 도입 필요성에 대한 고찰)

  • Jang, In-soo;Park, Jong-bae;Seo, Jung-chul
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.149-162
    • /
    • 2004
  • Quality assurance with high safety profile is one of the most critical issues to medical device manufacturing. In general, this issue was not paid proper attention with respect to acupuncture needle and its related devices. Acupuncture needles are manufactured through various standards ranging from purely hand-made, partially hand-made and partially machine-made, to fully machine-made mainly in China, Korea, and Japan. There is a large difference in quality between needles from different manufacturers. In order to provide a standard manufacturing guideline, it seems necessary to make a Korean Industrial standard (KS). The authors review this topic from an historical view point, investigate the current situation of the standardization of acupuncture needles in other developed countries, and inspect the general procedure to establish a KS in Korea in order to suggest a KS for acupuncture needles.

  • PDF

Design Criteria in Barrier Free Housing (장애물 없는 주택 설계기준에 관한 연구 - 국내 공동주택의 무장애(barrier free) 설계수준 평가를 중심으로 -)

  • Kim, Sang-Woon;Park, Kwani-Jae;Kang, Byoung-Keun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.10 no.2
    • /
    • pp.107-115
    • /
    • 2004
  • In this paper, the all units of residential housing that is not legislated in facility development law are analyzed and foreign design criteria that is related to barrier-free unit housing is comparing to domestic. Through the comparison in front door, living room, bathroom, bedroom, and kitchen, this paper aims to suggest internal barrier-free design criteria. This paper is limited to internal housing which are front door, living room, bedroom, bathroom, and kitchen. Also, the objectives of facility development law are U.S, Japan, German, and in case of U.S, UFAS is established by ADA, in Japan, Heart Building law and detail standard drawing are used, in German, DIN is used. The objective of domestic case study is the latest residential housings that are built over 2003. The flow of study is as follows ; First, the internal items of residential housing are abstracted, and each item is checked in facility development law that is legislated in. Next, through comparison of domestic and foreign facility development law related to housing, common items are abstracted and detail standards are defined. Domestic residential housings are analyzed in those standards. Finally, the problems that is the result of analysis are analyzed and the barrier free design criteria is abstracted in unit housing. Also, more developed items and future study are suggested.

  • PDF

Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • Biomedical Science Letters
    • /
    • v.22 no.4
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.

Quality Assesment of Domestic Nonautomatic Weighing Instruments by International Standards (국제기준에 의한 국내 비자동저울의 품질 평가에 관한 연구)

  • 김홍원;남궁재관;김창열;공재향
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.263-268
    • /
    • 2004
  • This study is to improve the quality of electronic weighing machine by providing a reformation plan on currently problems of domestic manufactured nonautomatic weighing instruments, and by test items and criteria considering internal situation on base of identification of quality level of domestic manufactures electronic weighing machine according to the international standards.