• Title/Summary/Keyword: Internal recycling rate

Search Result 26, Processing Time 0.026 seconds

The Nitrogen Behavior in the Continuous Inflow SBR according to Variations of Internal Recycling Rate (반송률 변화에 따른 연속 유입식 SBR 공정의 질소 거동)

  • Kim, Su-Yeon;Choi, Yong-Bum;Jo, You-Na;Han, Dong-Joon;Kwon, Jae-Hyouk
    • Clean Technology
    • /
    • v.25 no.3
    • /
    • pp.231-237
    • /
    • 2019
  • The BOD removal efficiency according to HRT of the continuous inflow SBR process was decreased from 92.1 ~ 96.0% at HRT 9 ~ 15 h to 86.9 ~ 90.7% at HRT 6 h, but a stable removal efficiency was shown up to HRT 6 h. The T-N removal rate was decreased to 80.1 ~ 87.9% at HRT 12 ~ 15 h, to 71.9 ~ 87.0% at HRT 9 h, and to 60.1 ~ 65.7% at HRT 6 h. As a result of the test of removing organic matter and nitrogen, the optimum HRT of the continuous inflow SBR reactor is determined as 9 h. The TCODcr removal efficiency was 88.4 ~ 96.0% and the TBOD removal efficiency was 92.1 ~ 98.1% as a result of examination of organic matter removal efficiency according to a change in the recycling rate (1 ~ 5Q) at HRT 9 h, suggesting that the a change in the recycling rate has a minimal effect on the removal of organic matter. The T-N removal efficiency was 70.3 ~ 80.4% at 1 ~ 2Q, 77.2 ~ 85.6% at 3Q and 61.5 ~ 80.8% at 4 ~ 5Q according to a change in the recycling rate. The TP removal efficiency was reduced to 75.0 ~ 84.6% at 1 ~ 4Q and to 63.3 ~ 72.4% at 5Q. This is presumably because the release and ingestion of phosphorus (P) by microorganisms is not performed smoothly at 5Q or more. Therefore, the optimum recycling rate for removing organic matter and nutrients was found to be 3Q.

The Actual State of Demolition and Pilot Dismantling in Apartment Building (해체공사의 수행실태 및 공동주택 분별해체 시험시공)

  • Kim, Hyo-Jin;Sohn, Jeong-Rak;Park, Seong-Sik;Yoon, Yung-Sang
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.113-118
    • /
    • 2007
  • Now a performance process of Demolition works is 'Before-Removal & After-Classification' method in Korea. This method is short of demolition time, but construction wastes contained substances lower recycling rate of construction, raise expenses of reclamation & treatment. Then the government has decided upon a positive 'Before-Classification & After-Removal' method, and substantially raise a recycling rate of construction wastes. Therefore, this study makes an investigation into state of internal and external demolition field through evaluating technological level, we make a proposal of dismantling method from there. Also, we put dismantling to the test in an apartment by proposed work process. As the result, it made a term of works increased for removing interior material. To solve this problem, we need to develop tools and methods of construction that can remove efficiently. From now on, we continuously need to study a breakdown system of dismantling, analysis of dismantling process and general system by inspecting entire demolition process. And we have to study details for making a specific thesis of method of removing interior material which was based on developing a suitable partial demolition machine and dismantling works.

  • PDF

Fundamental Study for Development of Pre-Heater for Warm In-Place Recycling in Korea (국내 현장중온재생공법의 프리히터 개발을 위한 기초연구)

  • Kim, Dae-Hun;Kim, Seung-Hoon;Kwon, Soo-Ahn;Kim, Yongjoo;Lee, Jaejun
    • International Journal of Highway Engineering
    • /
    • v.17 no.2
    • /
    • pp.31-37
    • /
    • 2015
  • PURPOSES : To design a pre-heater for warm in-place recycling equipment, three different heating systems were evaluated to determine their thermal efficiency. METHODS: In this study, a $30cm{\times}30cm{\times}15cm$ wheel-tracking specimen was used to measure the inner temperature as a function of the heating system. The inner temperature of the specimen was measured with a data logger at the surface, and at depths of 1cm, 2cm, 3cm, 4cm, and 5cm. To evaluate the thermal efficiency, the researchers used three different types of equipment, namely, IR, a heating wire, and a gas burner. RESULTS: The IR heating system exhibits a higher level of performance than the others to achieve the target temperature at a depth of 5cm in the specimen. The gas burner system was capable of heating the surface to a temperature of up to $600^{\circ}C$. The other types, however, cannot heat the surface up to 600. The thermal efficiencies were measured based on the laboratory conditions. CONCLUSIONS: To find the most effective system for application to the development of a pre-heater for warm in-place recycling, various systems (IR, heating wire, gas burner) were examined in the laboratory. As a result, it was found that the hot plate of a gas burner system provides the highest temperature at the surface of the asphalt but, of all the systems, the IR system provides the best internal temperature increase rate. Furthermore, a gas burner can age the asphalt binder of the surface layer as a result of the high temperature. However, the gas burner cannot attain the target temperature at 5cm. The IR system, on the other hand, is effective at increasing the internal temperature of asphalt.

Feasibility Analysis on Slag Reprocessing Project in Lubumbashi, Democratic Republic of the Congo (DR콩고 루붐바시 슬래그재처리사업(再處理事業)의 경제성(經濟性) 평가(評價))

  • Kim, Yu-Jeong;Kim, Dae-Hyoung
    • Resources Recycling
    • /
    • v.21 no.1
    • /
    • pp.49-59
    • /
    • 2012
  • One of the world's top resource-rich countries, the Democratic Republic of the Congo has ample reserves of cobalt, iron ore, copper and diamond in particular. Importing most of major mineral resources, the Republic of Korea has examined-together with the Congo government since 2008-the possibility of a project where it supports port construction in the Democratic Republic of the Congo and acquires useful minerals such as zinc, cobalt and copper in exchange through slag reprocessing in the local city of Lubumbashi. This study conducted feasibility analysis on the slag reprocessing project in Lubumbashi, Congo and found that the project's payback period stands at 6.7 years, net present value(NPV) at 34 million dollars and internal rate of return(IRR) at 17.4%. According to sensitivity analysis that takes into account uncertainties concerning taxation, fixed cost, operational cost and resource prices, the NPV of the project ranges from -24.8 million dollars to 92.7 million dollars.

Economic Evaluation of a Crush-screen Hybrid Pretreatment Process for Waste Vinyl (폐비닐의 파쇄/선별 융합 전처리 공정의 경제성 평가)

  • Seo, Su Been;Cho, Il Ho;Yun, Hyun Pyo;Kang, Seo Yeong;Kim, Hyung Woo;Lee, See Hoon
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.289-295
    • /
    • 2019
  • Though the usage of vinyls and plastics produced from fossil fuels has been increasing in the world, the eco-friendly domestic disposal or recycling of waste vinyls has to be executed because the migration or importation of waste vinyls or waste plastics are globally prohibited. Even though the eco-friendly domestic disposal or recycling of waste vinyls and waste plastics should be developed, promising eco-friendly recycling methods are few because there are extraneous substances in waste vinyls and waste plastics. Also, conventional incineration and landfill methods result in secondary contamination and then increase disposal costs. Therefore, the selective elimination of extraneous substances or other materials included in waste vinyls and waste plastics could make valuable recycling or reuse possible. In particular, the novel hybrid process in which crushing and screening are simultaneously conducted in a rotary kiln type reactor can domestically maximize the material recycling or reuse. In this study, the feasibility study for a crushing/screening hybrid process developed in Korea was performed and evaluated in case of thermal recycling (TR) and material recycling (MR). The effect of various subsidies on economic efficiency was especially evaluated by means of domestic recycling plans. The incentive revenues from waste vinyl recycling and the incineration share of waste vinyls affected the net present values and internal rate of returns of the hybrid process.

Upcycling Awareness Research Fashion Clothing Goods for Korean University Students (국내 대학생의 패션의류제품 업사이클링 인식도 조사)

  • Choi, Se-Lin;Choi, Eun-Hee;Do, Wol-Hee
    • Fashion & Textile Research Journal
    • /
    • v.16 no.1
    • /
    • pp.111-117
    • /
    • 2014
  • This study investigated the perception of upcycling for sensitive university students in regards to fashion trends. It was conducted through questionnaires delivered to male and female college students who majored in clothing related subjects from June 2012 to June 2013 in Gwangju. The contents for this research are general details, seriousness of environmental resources, awareness of upcycle, and purchasing intention for upcycling products. Most of the respondents said that recycling of resources is absolutely necessary due to the impact of environmental pollution and the consumption of resources. On the contrary, the experience of the respondents which purchased recycling products was low. The awareness of also was low, upcycling, internal upcycling brands and internal consumption groups, however, the decisions for subsequent purchases were positive. The reasons for the unsatisfactory of upcycling of products were due to quality and price. The reaction for many upcycle goods had the best question response rate in daily supplies part; subsequently, this study suggested 3 items, apparel products, fashion accessories, and daily supplies. In addition, a group which contains people who expend more for clothing had a lower awareness of upcycle and purchasing intention than other groups that contained some people who expend less. The results of the study can be used in data that recognize the necessary of upcycle education for university students, and develop educational programs. It can also encourage the purchase of upcycle products that reduce the consumption of resources.

Effect of Microwave and High-temperature Heating Methods on Contaminates Removal from Oil-contaminated Soil by Heat Treatment (유류오염토양의 열처리에서 micro파와 고온발열체 방법이 오염제거에 미치는 영향)

  • Ha, Sang-An;Wang, Jei-Pil
    • Resources Recycling
    • /
    • v.23 no.2
    • /
    • pp.46-52
    • /
    • 2014
  • This study was conducted to observe the removal efficiency of oil-contaminated soil by various tests using microwaves and high-temperature heating elements. The water content was measured with the treatment amount, which was lowered to 300g in a relatively short amount of time. The treatment rate of TPH(Total Petroleum Hydrocarbons) showed the highest value with 70.1% when the SiC-activated carbon heating element was at 4 kW/kg, compared to the SiC heating element used alone. In particular, the higher electric power became, the higher treatment rate became, except at 3 kW. In the case of the heating element made by the fusion of SiC and activated carbon, the internal temperature exceeded $300^{\circ}C$ and again fell when it was treated at 4 kW for about 2 minutes. Then, after about 8 minutes, it rose again. On the basis of such results, the energy content necessary for the sample was calculated according to the electric power of microwaves, and tthe constant of TPH treatment was measured by tests on the treatment characteristics of oil-contaminated soil.

Economic Analysis of Dry Bottom Ash Handling System in a Pulverized Coal Thermal Power Plant in Korea (Ⅱ) -Case Study for Retrofitting the Existing Facility (國內 微分炭 化力發電所에서 바닥재 再活用을 위한 乾式 바닥재 處理시스템 導入의 經濟性 分析 (Ⅱ) -旣存設備 改善事業에 대하여)

  • Oh, Se-Won
    • Resources Recycling
    • /
    • v.14 no.2
    • /
    • pp.56-61
    • /
    • 2005
  • Economic feasibility for retrofitting the wet bottom ash handling system to the dry system in a existing 500MW${\times}$2 units pulverized coal thermal power plant in Korea was studied. Replacing to the dry system requires the initial capital costs of 13,415,127,000\, and saves the operating costs of 935,345,000\ per year. Economic analyses based on these results showed that the initial capital cost would not be recovered within the service life of the facilities at the interest rate of 10%, and the internal rate of return of 5.6% were obtained. Thus, the retrofitting to the dry system was not economically favorable in the current condition. However, the retrofitting would be profitable when the ash disposal cost and ash selling price were increased over 15,000\/MT or 17,000\/MT, respectively.

Effect of HRT and Internal Recycle Ratio on Removal of Organic and Nitrogen in Swine Wastewater by Anoxic-Oxic Process Combined with Membrane (분리막이 결합된 무산소·호기 공정을 이용한 축산폐수처리에서 수리학적체류시간 및 내부반송율이 유기물 및 질소제거에 미치는 영향)

  • Whang, gye dae;Lee, bong hee;Lee, hyun duk
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.603-609
    • /
    • 2004
  • The objective of this study was to determine the optimal operation conditions in an anoxic oxic process to eliminate both organic and nitrogen matters in swine wastewater. For the purpose of this, the removal efficiency was evaluated with various HRTs and internal recycling ratio. During the whole 580 days of experiment, HRTs had been gradually decreased in an order of 20, 14, 12 and l0days, and the internal recycle ratio was kept at 20Q. So as to determine the effect of the internal recycle ratio on the nitrogen removal, the internal recycle ratio had been gradually increased from 20Q to 50Q while HRT was maintained at 12days. As a result, it was shown that the removal efficiency of organic matter was above 95% regardless of changing of HRTs. The average influent concentration of TCODcr and SCODcr were 24,854 mg/L and 18,920 mg/L, respectively. Average removal efficiency of TKN was shown to be nearly 98% when HRT was kept at 12days; however, the $NH_4{^+}-N$ concentration of effluent was shown to be increased when the loading rate of $NH_4{^+}-N$ was increased to $0.602 kgNH_4{^+}-N/m^3$-day by means of decreasing HRT to 10days. It was concluded that nitrogen loading rates should be more considered rather than organic loading rates in case of determining an optimal HRT. When gradually increasing the internal recycle ratio from 20Q to 50Q, the removal efficiency of organic matters and TKN were 96% and 98%, respectively so that no significant changes in removal efficiency was detected. However, when the internal recycle ratio was kept at 50Q, it was revealed that the $NO_3-N$ concentration of effluent seemed to drop and the average $NO_3-N$ concentration of effluent was around 52 mg/L.

Estimation of Characteristics Treatment for Food Waste with Blast Volume and Preheating of Air using Bio-Drying Process (Bio-drying 공법 활용 공기 투입 및 예열에 따른 음식물류 폐기물 분해 특성 평가)

  • Park, Seyong;Lee, Wonbea
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.15-25
    • /
    • 2022
  • In this study, the efficiency of treatment of moisture and organic matter in food waste was analyzed according to the air blast volume and preheating using the bio-drying method. Te mount of air blast volume and preheating were determined by the evaluation of temperature and CO2 during food waste treatment using the bio-drying method. As a results, the increase in the air blast volume increased the moisture removal efficiency and removal rate, but, lowered the temperature inside the bio-drying by the decease in microbial activity. In order to maintain the activity of microorganisms, it was estimated that it was necessary to inject an appropriate air blast rate according th the properties of the food waste. In this study, the injection of air blast volume at 15L/min was optimal. It was evaluated that the organic matter and water removal rates according to the presence or absence of air preheating, the organic matter removal rate and water removal rate increased by 3-5% when air preheating was not performed. Also, there was no internal aggregation caused by the generation of condensate inside the bio-drying. Therefore, for effective bio-drying of food waste, it is necessary to maintain an appropriate air blast volume to maintain microbial activity, and it is considered that injection through preheating of air is required.