• Title/Summary/Keyword: Internal penetration

Search Result 167, Processing Time 0.025 seconds

Experimental Study on the Water Penetration of Concrete with Water Pressure (수압을 받는 콘크리트에서의 수분 이동에 관한 실험적 연구)

  • You, Jo-Hyeong;Lee, Han-Seung;Kang, In-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.573-576
    • /
    • 2006
  • The objective of the study is to investigate the depth of penetration of concrete water forced in under pressure. For this purpose, the experiments for the depth of penetration by selecting the factors and levels such as water pressure, pressure time were executed. The flow of water of concrete examined theoretically and experimentally. As a result, It is found that in the case of low water pressure approximately 0.15Mpa or less, the flow is Darcy seepage flow, the same as flow in an ordinary sand stratum, whereas in the case of high water pressure, the flow is diffused seepage flow accompanied by internal deformation of concrete.

  • PDF

Suction Penetration Review of Circular Steel Pipes by Field Test (현장 실험을 통한 원형강관 석션관입성 검토)

  • Kim, Hyun-Joo;Choi, Jin-O
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.12
    • /
    • pp.35-43
    • /
    • 2020
  • Currently, cofferdams of circular cross section are widely applied as temporary facilities for the installation of bridge foundations in river/sea bridge construction in Korea. Existing caisson, sheet pile, and cell type cofferdam are widely used, but these methods take a lot of time and cost for installation and dismantling. In the case of the existing sheet pile construction method, attention is needed to secure internal and external stability because of the damage to the sheet pile due to ground penetration and difficulty in connecting element members. In this study, penetration design of circular steel pipes using suction pressure was performed on the soft ground of the west coast, and it was confirmed that penetration construction using suction pressure was possible through field tests. It was confirmed that applying the ground analysis results using the cone penetration test (CPT) to the design rather than the standard penetration test (N value) results more similar to the field test results. In addition, it was confirmed that local failure of the inside of the cofferdam was induced when a suction pressure higher than the upper limit suction pressure was applied in the silty sand.

Analysis of Plate Cutting Performance of Aluminum Linear Shaped Charge with Non-uniform Penetration Performance (불균일한 침투성능을 갖는 알루미늄 선상성형작약의 판재 절개성능 분석)

  • Young Jae Kim
    • Journal of the Korea Society for Simulation
    • /
    • v.33 no.3
    • /
    • pp.27-35
    • /
    • 2024
  • Generally, an Linear Shaped Charge(LSC) is used for cutting a mechanical structure of various weapon systems. The penetration performance of an LSC is subjected to the type of explosive, the amount of explosive charge per unit length, the type of sheath material, stand-off distance from the target etc. In addition, the non-uniform cross-sectional shape originated from the manufacturing process may affect penetration performance. In this study, in order to analyze the penetration performance of an LSC, Computed Tomography(CT) images of its internal shape were taken and penetration experiments of the LSC were performed on a square metal bar. The experimental results showed that the penetration depths varied depending on the longitudinal position of the LSC, and at some locations, did not meet the required cutting performance. The LSC used in the experiment was manufactured to be able to cut a 4 mm plate, but in the results of the penetration performance experiment, there were many locations where the penetration depth was less than 4 mm. To find this reason, the penetration performance that did not meet the required cutting performance was simulated through AUTODYN based numerical analysis to confirm whether the LSC is cut in the plate. Through numerical analysis, it was confirmed that the penetration performance of an LSC varies depending on the thickness of the incision target due to the distribution of stress.

An Experimental Study on Spray Characteristics of Multi-Hole GDI Injector (다공형 GDI 인젝터의 분무특성에 대한 실험적 연구)

  • Lee, Sung-Won;Park, Sung-Young
    • Journal of ILASS-Korea
    • /
    • v.16 no.4
    • /
    • pp.201-209
    • /
    • 2011
  • Optimum engine performance is obtained when the spray characteristics is well matched to the geometry of a combustion chamber. Among many parameters governing the combustion performance in internal combustion engine, fuel supply characteristics and atomization are important performance factors. Therefore, spray characteristics of high pressure multi-hole injector has been studied experimentally. An experimental test system has been made to operate high pressure injection system and to visualize spray behavior. Spray visualization has been performed to analyze spray formation, spray cone angle, bent angle and penetration length. Spray interaction with piston has been analyzed with various injector installation angle, injection pressure and ambient pressure. Test results show that penetration length is greatly influenced by the injection pressure. Penetration length is decreased as ambient pressure increased. Spray cone angle is increased as injection pressure and ambient pressure increased. However, bent angle is not influenced by the change of injection pressure and ambient pressure. Spray cone angle distribution map is plotted using the experimental data. Fuel movement around the spark-plug has been enforced as increasing injector installation angle.

Evaluation of Compressive Strength and Freeze-thaw Resistance Properties of Concrete using Superabsorbent Polymer (고 흡수성 폴리머를 혼입한 콘크리트의 압축 강도 및 동결융해 저항성 평가)

  • Kim, Il-Sun;Choi, So-Yeong;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.86-94
    • /
    • 2020
  • When the Superabsorbent Polymer (SAP) is added into concrete, the slump decreases rapidly, deteriorating the workability, the internal curing effect can be obtained through the water absorption and discharge process, and the internal voids of the concrete are increased. In this study, the effects of internal curing and voids were evaluated by evaluating the compressive strength, freeze-thaw resistance, and chloride penetration resistance of SAP-adding concrete that secured workability using a water reducing agent. Also, the internal curing effect of SAP was evaluated by dividing the curing conditions of concrete into water curing and sealed curing. From the result, as the SAP adding ratio increased, the amount of water reducing agent increased, and as for the compressive strength, the SAP adding ratio of 1.5% showed the greatest compressive strength. In particular, in the case of sealed curing showed higher compressive strength than the water curing. It is considered that the compressive strength increased due to the reduction of the effective water-cement ratio and the internal curing effect. Adding 1.0~1.5% of SAP improved the freeze-thaw resistance similar to the case of adding the AE agent, and the addition of more than 1.0% of SAP improved the chloride penetration resistance. The optimal adding ratio of SAP is 1.5%, and the adding ratio of 2.0% or more adversely affects the compressive strength and freeze-thaw resistance.

The Correlation Analysis between Dynamic Cone Penetration Test and Plate Loading Test Results for Evaluation of Dam Conditions (제체 상태 평가를 위한 동적 콘 관입시험과 평판재하시험 결과의 상관관계 분석)

  • Jung, Young-Hoon;Kim, Seongmin;Lim, Jeong-yeul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.4
    • /
    • pp.33-38
    • /
    • 2018
  • The internal erosion due to poor compaction of the material was the main cause of collapse of the embankment in Korea. The assessment of the compaction state of the dam body was a very important check in the safety diagnosis of the embankment. In this study, the correlation between dynamic cone penetration test and plate loading test which is the most typical compaction evaluation technique was analyzed to verify the applicability of the dynamic cone penetration test in evaluating the compaction state of the dam body. The standard penetration tests were carried out six times to define soil properties and depth of the test site. The spatial distributions were obtained by the Kriging method after 15 times of plate loading tests and 47 times of dynamic cone penetration tests. The Pearson correlation coefficient between the spatial distribution of the plate loading test and the dynamic cone penetration test spatial distribution at the constant penetration depth was calculated. The load distribution in the plate loading test and the blow counts at penetration depths of 5 cm, 10 cm and 15 cm in the dynamic cone penetration test showed a weak positive correlation.

Development of Internal Pressure Maintenance Equipment with Multi-layer Construction Bladder (다층구조 블래더를 이용한 내압제한장치 개발)

  • Baek, Nak-Gon;You, Gyong-Won;Jang, Ki-Won;Jun, Pil-Sun;Ha, Byoung-Geun;Lee, Beom-Cheol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.335-337
    • /
    • 2009
  • Internal Pressure Maintenance Equipment absorbs internal pressure variation for it's storage has developed. The bladder ; main item of Internal Pressure Maintenance Equipment, has developed with multi-layer to prevent a penetration and to improve durability. And durability test and environment test was carried out to verify the performance in the condition that could be happened in storage or operation.

  • PDF

The Influence of Paper Stock Type on Characteristics of Sizing (지료조성에 따른 종이의 사이징 특성)

  • Cheong Sang Jin;Kim Bong Yong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.2 s.110
    • /
    • pp.11-20
    • /
    • 2005
  • This study was carried out to investigate the influence of paper stock type and heat treatment on sizing effect. Various types of pulps were used to make handsheets sized internally with AKD(alkyl ketene dimer) and externally with CMC(carboxyl methyl cellulose). Most of the handsheets were treated with heat by dry oven $(100^{\circ}C,\;30min)$ to evaluate the effect of heat treatment on sizing development. Internal sizing development of newsprint was very bad, but the effect of heat treatment was much higher than those of NBKP, BCTMP. In case of surface sizing, newsprint was more effective compared to the other pulps. Considering above mentioned results, it seems that internal sizing slows down water into paper by molecular diffusion much more than capillary penetration, but surface sizing slows down capillary penetration. With regard to density, a higher thickness sheets showed high heat treatment effect on sizing, therefore it assumed that heat treatment effect on sizing had very close relationship with sheet density.

Development of a quality evaluation method and computer program of Sand Compaction Pile (모래다짐말뚝의 품질평가 방법과 프로그램의 개발)

  • Jeon, Heung-Soo;Im, Jong-Chul;Kang, Yeoun-Ike;Kwon, Jeong-Geun;Joo, In-Gon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1132-1140
    • /
    • 2009
  • Recently soil improvement methods are using in many ways such as costal and soft ground of inland. Among them, sand compaction pile be widely used because of quiet few advantages. There are two ways for quality evaluation method of sand compaction pile. Especially standard penetration test is used the most general method. However, Current method have problems in that it is not consider the condition of construction site. Therefore this study is propose new quality evaluation method. Relation of N-$\Phi$ is always not fixed but changing by condition of construction site. By through the Laboratory test we can know relationship between relative density and internal friction. Also this study propose revision for effective stress. From these study, we can acquire more accurate and reasonable result than current method.

  • PDF

The Dose Distribution of Arc therapy for High Energy Electron (고에너지 전자선 진자조사에 의한 선량분포)

  • Chu, S.S.;Kim, G.E.;Suh, C.O.;Park, C.Y.
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 1983
  • The treatment of tumors along curved surfaces with stationary electron beams using cone collimation may lead to non-uniform dose distributions due to a varying air gap between the cone surface and patient. For large tumors, more than one port may have to be used in irradiation of the chest wall, often leading to regions of high or low dose at the junction of the adjacent ports. Electron-beam arc therapy may elimination many of these fixed port problems. When treating breast tumors with electrons, the energy of the internal mammary port is usually higher than that of the chest wall port. Bolus is used to increase the skin dose or limit the range of the electrons. We invertiaged the effect of various arc beam parameters in the isodose distributions, and combined into a single arc port for adjacent fixed ports of different electron beam eneries. The higher fixed port energy would be used as the arc beam energy while the beam penetration in the lower energy region would be controlled by a proper thickness of bolus. We obtained the results of following: 1. It is more uniform dose distribution of electron to use rotation than stationary irradiation. 2. Increasing isocenter depth on arc irradiation, increased depth of maximum dose, reduction in surface dose and an increasing penetration of the linear portion of the curve. 3. The deeper penetration of the depth dose curve and higher X-ray background for the smaller field sized. 4. If the isocenter depth increase, the field effect is small. 5. The decreasing arc beam penetration with decreasing isocenter depth and the isocenter depth effect appears at a greater depth as the energy increases. 6. The addition of bolus produces a shift in the penetration that is the same for all depths leaving the shape of the curves unchanged. 7. Lead strips 5 mm thick were placed at both ends of the arc to produce a rapid dose drop-off.

  • PDF