• Title/Summary/Keyword: Internal noise

Search Result 621, Processing Time 0.022 seconds

A Continuous Fine-Tuning Phase Locked Loop with Additional Negative Feedback Loop (추가적인 부궤환 루프를 가지는 연속 미세 조절 위상 고정루프)

  • Choi, Young-Shig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.4
    • /
    • pp.811-818
    • /
    • 2016
  • A continuous fine-tuning phase locked loop with an additional negative feedback loop has been proposed. When the phase locked loop is out-of-lock, the phase locked loop has a fast locking characteristic using the continuous band-selection loop. When the phase locked loop is near in-lock, the bandwidth is narrowed with the fine loop. The additional negative feedback loop consists of a voltage controlled oscillator, a frequency voltage converter and its internal loop filter. It serves a negative feedback function to the main phase locked loop, and improves the phase noise characteristics and the stability of the proposed phase locked loop. The additional negative feedback loop makes the continuous fine-tuning loop work stably without any voltage fluctuation in the loop filter. Measurement results of the fabricated phase locked loop in $0.18{\mu}m$ CMOS process show that the phase noise is -109.6dBc/Hz at 2MHz offset from 742.8MHz carrier frequency.

Optimum Welding Position between Shell and Cylinder based on SEA (SEA 를 이용한 쉘과 실린더의 최적 용접 조건)

  • Ahn, Byoung-Ha;Lee, Jang-Woo;Jeon, Simon;Yang, Bo-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.258-264
    • /
    • 2012
  • The overall aim of this paper is to determine coupling loss factor of welding point between shell and cylinder using loss factor and structural loss factor. For this purpose, two kinds of loss factor were adopted. One is loss factor of each sub structure, another is structural loss factor based on the complex welded or assembled structure. Using these two parameters, it is possible to derive the coupling loss factor which represents characteristic condition of SEA theory. Coupling loss factor of conjunction in complex structure was expressed as power balance equation. The derived equation for a coupling loss factor has been simplified on the assumption of one way (uni-directional) power flow between multi-sub structures. Using these conditions, it is possible to find the equation of coupling loss factor expressed as above two loss factors. To check the effectiveness of above equation, this paper used two-stage application. The first approach was application between simple cylinder and shell. The next was adopted rotary compressor. Rotary compressor has three main conjunctions between shell and internal vibration part. This equation was applied to find out the optimum welding point with respect to reduce the noise propagation. It shows the effective tool to evaluate the coupling loss factor in complex structure.

  • PDF

A $0.5{\mu}m$ CMOS FM Radio Receiver For Zero-Crossing Demodulator (Zero-Crossing 복조기를 위한 $0.5{\mu}m$ CMOS FM 라디오 수신기)

  • Kim, Sung-Woong;Kim, Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.100-105
    • /
    • 2010
  • In this paper, a FM radio receiver integrated circuit has been developed based on $0.5{\mu}m$ CMOS process for Zero-Crossing FM demodulator over the 88MHz to 108MHz band. The receiver is designed with the low-IF architecture, and includes Low Noise Amplifier(LNA), Down-Conversion Mixer, Phase Locked Loop(PLL), IF LPF, and a comparator. The measured results of the LNA and Mixer show that the conversion gain of 23.2 dB, the input PldB of -14 dBm, and the noise figure of 15 dB. The measured analog block of the LPF and comparator show the voltage gain of over 89 dB, and the IF LPF can configure the passband from 600KHz to 1.3MHz with 100KHz step through the internal control register banks. The designed FM radio receiver operates at 4.5V with the total current consumption of 15.3mA, so the total power consumption is about 68.85mW. The commercial FM radio has been successfully received.

Design of the Upstream Cable Modem for Symmetric Multimedia Services over HFC Networks (HFC망 기반 대칭형 멀티미디어 서비스를 위한 상향 채널 케이블 모뎀 설계)

  • Cho, Byung Hak
    • Journal of Broadcast Engineering
    • /
    • v.10 no.3
    • /
    • pp.401-412
    • /
    • 2005
  • We propose and design the algorithms of symbol timing recovery, carrier recovery, and equalization for the receiver of S-DMT cable modem, which supports more channels and better symmetric mutimedia services over HFC network. We evaluate the performance of the concatenated entire receiving system of 16QAM, 64QAM in the mixed noise channel of AWGN, ISI and impulse. The result of evaluation shows those algorithms work correctly and designed S-DMT receiver has good performance. We also verify the designed system has excellent immunity against impulse noise channel of practical Cable TV networks by the result of simulation with the parameters of impulse internal $\varepsilon$ and noise power $\gamma^{k}$.

Design of adhesive wireless bookbinding machine with optimal motor control and automatic cover insertion (최적의 모터 제어 및 겉표지 자동 투입 기능을 적용한 접착식 무선 제본기 설계)

  • Song, Je-Ho;Lee, In-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.198-203
    • /
    • 2019
  • An adhesive wireless bookbinding machine was designed with optimal motor control and automatic cover insertion for bookbinding. The noise level was improved by modifying the thrust of the machine and changing from a compressor method to an AC induction motor control method. The automatic cover insertion function was added to improve the task speed. Motor and decelerator damage can be caused by sudden braking and acceleration of the motor rotation (clockwise and counter-clockwise), so a buffer-type locational control system was developed to secure stable movement and durability. The complicated internal design was also simplified, and the volume and weight were decreased. The results show that the noise was decreased by 57% from 135 dB to 71.7 dB, and the task speed was decreased by 57% from 18 s to 9.58 s. The automatic cover insertion was designed to supply a maximum of 130 sheets per supply.

Seismic Data Processing Using BERT-Based Pretraining: Comparison of Shotgather Arrays (BERT 기반 사전학습을 이용한 탄성파 자료처리: 송신원 모음 배열 비교)

  • Youngjae Shin
    • Geophysics and Geophysical Exploration
    • /
    • v.27 no.3
    • /
    • pp.171-180
    • /
    • 2024
  • The processing of seismic data involves analyzing earthquake wave data to understand the internal structure and characteristics of the Earth, which requires high computational power. Recently, machine learning (ML) techniques have been introduced to address these challenges and have been utilized in various tasks such as noise reduction and velocity model construction. However, most studies have focused on specific seismic data processing tasks, limiting the full utilization of similar features and structures inherent in the datasets. In this study, we compared the efficacy of using receiver-wise time-series data ("receiver array") and synchronized receiver signals ("time array") from shotgathers for pretraining a Bidirectional Encoder Representations from Transformers (BERT) model. To this end, shotgather data generated from a synthetic model containing faults was used to perform noise reduction, velocity prediction, and fault detection tasks. In the task of random noise reduction, both the receiver and time arrays showed good performance. However, for tasks requiring the identification of spatial distributions, such as velocity estimation and fault detection, the results from the time array were superior.

Cohort Study for the Effect of Chronic Noise Exposure on Blood Pressure among Male Workers (만성적 소음노출이 혈압에 미치는 영향에 대한 코호트연구)

  • Cha, Tae-Joon;Kim, Jang-Rak;Kang, Wee-Chang;Yaang, Seung-Rim;Lee, Choong-Ryeol;Yoo, Cheol-In;Lee, Ji-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.3
    • /
    • pp.205-213
    • /
    • 2002
  • Objective : Whether exposure to chronic noise induces an increase in blood pressure, or the development of hypertension, has not been established. A cohort study was performed to identify the effects of chronic noise exposure on blood pressure. Methods : 530 males working at a metal manufacturing factory in Busan, Korea were enrolled for the study. They were monitored for 9 consecutive years, from 1991 to 1999, with an annual health check-up. The subjects were divided into 4 groups, which were determines by noise level categories(NLC) according to noise intensity ; NLC-I: office workers, exposed to noise a level below 60dB(A) ; NLC-II: field technical supporters or supervisors, frequently exposed to workplace noise, wearing no hearing protection device; NLC-III: workers, exposed to workplace noise below 85dB(A), wearing ear plugs or muffs; NLC-IV: workers, exposed to workplace noise over 85 dB(A), wearing both ear plugs and muffs. Results : After controlling possible confoundens, such as baseline age, smoking, alcohol intake, exercise, family history of hypertension, systolic(SBP) of diastolic blood pressure(DBP) and changes in BMI (body mass index), the pooled mean for the systolic blood pressures, over the duration of the study period, were 3.8mmHg, 2.0mmHg and 1.7mmHg higher in NLC-IV, NLC-III NLC-II groups, respectively, than in the NLC-I group. There were no significant differences in the diastolic blood pressures between the groups. Conclusion : This study suggests that chronic noise exposure increases systolic blood pressure independently, among male workers.

Conductivity Imaging of a Canine Head using a 3T MREIT System with a Carbon-Hydrogel Electrode: Postmortem Experiment (3T MREIT 시스템을 이용한 실험견 사체의 두부 도전율 영상)

  • Jeong, Woo-Chul;Kim, Young-Tae;Minhas, Atul S.;Kim, Hyung-Joong;Lee, Tae-Hwi;Kang, Byeong-Teck;Park, Hee-Myung;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.179-184
    • /
    • 2009
  • Magnetic Resonance Electrical Impedance Tomography (MREIT) is a new bio-imaging modality providing cross-sectional conductivity images from measurements of internal magnetic flux densities produced by externally injected currents. Recent MREIT studies demonstrated successful conductivity image reconstructions of postmortem and in vivo canine brain. However, the whole head imaging was not achieved due to technical issues related with electrodes and noise in measured magnetic flux density data. In this study, we used a new carbon-hydrogel electrode with a large contact area and injected 30 mA imaging current through a canine head. Using a 3T MREIT system, we performed a postmortem canine experiment and produced high-resolution conductivity images of the entire canine head. Collecting magnetic flux density data inside the head subject to multiple injection currents, we reconstructed cross-sectional conductivity images using the harmonic $B_z$ algorithm. The conductivity images of the canine head show a good contrast not only inside the brain region including white and gray matter but also outside the brain region including the skull, temporalis muscle, mandible, lingualis proprius muscle, and masseter muscle.

A Case of Non-cardiogenic Pulmonary Edema caused by Nitrogen Dioxide Poisoning after Cutting Copper Pipe with an Oxyethylene Torch (산소 에틸렌 토치로 동파이프 절단작업 후 발생한 이산화질소 중독에 의한 비심인성 폐부종 1례)

  • JeGal, Yang-Jin;Ahn, Jong-Joon;Seo, Kwang-Won;Cha, Hee-Jeong;Kwon, Woon-Jung;Kim, Yang-Ho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.4 no.2
    • /
    • pp.175-179
    • /
    • 2006
  • Welders are exposed to a number of hazards including metal fumes, toxic gases, electricity, heat, noise, and radiation such as ultraviolet and infrared light. We encountered a patient who developed non-cardiogenic pulmonary edema within a day after cutting copper pipe with an oxyethylene torch. The patient was a 26-year-old welder. He complained of dyspnea, generalized myalgia, and febrile sensation the following morning. The patient's chest X-ray and chest CT scan showed extensively distributed and ill-defined centrilobular nodules. Both his symptoms and chest X-ray abnormalities improved spontaneously. We attributed the patient's symptoms to non-cardiogenic pulmonary edema due to nitrogen dioxide, reasoning that: 1) the pipe consisted only of copper, according to material safety data sheet (MSDS); 2) a previous report in the literature demonstrated increased nitrogen dioxide levels under similar conditions; 3) the patient's clinical course and radiologic findings were very reminiscent of non-cardiogenic pulmonary edema following accidental exposure to nitrogen dioxide.

  • PDF

The Effect of Pump Intake Leaning Angle and Flow Rate on the Internal Flow of Pump Sump

  • Lee, Youngbum;Kim, Kyung-Yup;Chen, Zhenmu;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.74-80
    • /
    • 2017
  • Pump sump system or pumping stations are built to draw water from a source such as river and used for irrigation, thermal power plants etc. If pump sump is improperly shaped or sized, air entraining vortices or submerged vortices may develop. This may greatly affect pump operation if vortices grow to an appreciable extent. Moreover, the noise and vibration of the pump can be increased by the remaining of vortices in the pump flow passage. Therefore, the vortices in the pump flow passage have to be reduced for a good performance of pump sump station. In this study, the effect of pump intake leaning angle and flow rate on the pump sump internal flow has been investigated. There are three cases with different leaning angle. Moreover, a pipe type with elbow also has been studied. The flow rate with three classes of air entraining vortices has been examined and investigated by decreasing the water level. The result shows that the air entraining vortices easily occurs at the pump intake with large leaning angle. Moreover, the elbow type of the pump intake easily occurs air entraining vortices at the high flow rate (or velocity) in comparison to other pump intake type.