• 제목/요약/키워드: Internal membrane

검색결과 537건 처리시간 0.033초

Study of Mylabris Phalerata on Anti-cancer Effects in Some Kinds of Cancer Cells (반모가 수종의 인체 암세포에 미치는 영향)

  • Kim, Jin-Sung;Yoon, Sang-Hyub;Ryu, Bong-Ha;Ryu, Ki-Won;Jung, Myung-Chai
    • The Journal of Internal Korean Medicine
    • /
    • 제25권2호
    • /
    • pp.202-213
    • /
    • 2004
  • Object : Objective: This study was conducted to investigate the anti-cancer effects of Mylabris phalerata (반모) in some kinds of cancer cells. Materials and Methods: Some kinds of cancer cells lines were treated. We used nine kinds of cancer cell lines, such as stomach cancer cells (Kato), lung cancer cells (Calu-1, NCI-H 1395), urinary bladder cancer cells (HS789T), bone cancer cells (Saos-2), brain cancer cells (SK-N-MC), liver cancer cells (Hep-G2), skin cancer cells (Mo-1) and prostate cancer cells (PC-3) with the water decoction of Mylabris phalerata. The histological changes of all cell lines in the media (RPMI-1640) containing the decoction of Mylabris phalerata were observed and we examined cell death assay by trypan blue exclusion testing was examined. Finally, the change of mitochondrial membrane potential was measurd and the inhibitory effect of Mylabris phalerata on cell increase was examined by analyzing the cell cycle. Results: In histologic change all cancer cell lines showed withdrawn and floating appearance that is typical in cellular impairment. Most of the cell lines showed over 50% death rate after 24 hours in trypan blue exclusion tests. Especially the stomach, urinary bladder. brain and liver cell lines showed over 30% death rate after 12 hours. All cell lines treated with Mylabris phalerata were less stained than the control group and the mitochondrial membrane potential in the Mylabris phalerata treated cell lines was markedly lower than that in the control group. The measurement of DNA quantity in all cell lines showed the disappearance of the peak and the thickened left axis, which suggests that all cellular DNA degraded. Conclusion: Mylabris phalerata had cytotoxicity on various kinds of cancer cell lines and the mechanism of that was the impairment of mitochondria by the breakdown of the mitochondrial cell membrane. We propose that this is in part attributable to the destruction of DNA in cancer cells.

  • PDF

A Numerical Study on the Internal Flow Characteristics and Pumping Performance of a Piezoelectric-based Micropump with Electromagnetic Resistance (전자기 저항을 이용한 압전 구동방식 마이크로 펌프의 내부유동 특성과 펌핑성능에 대한 수치해석적 연구)

  • An, Yong-Jun;Oh, Se-Hong;Kim, Chang-Nyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제27권10호
    • /
    • pp.84-92
    • /
    • 2010
  • In this study a numerical analysis has been conducted for the flow characteristics and pumping performance of a piezoelectric-based micropump with electromagnetic resistance exerted on electrically conducting fluid. Here, electromagnetic resistance is alternately applied at the inlet and outlet with alternately applied magnetic fields in association with the reciprocal membrane motion of the piezoelectric-based micropump. A model of Prescribed Deformation is used for the description of the membrane motion. The internal flow characteristics and pumping performance are investigated with the variation of magnetic flux density, tube size, displacement of membrane and the frequency of the membrane. It turns out that the current micropump has a wide range of pumping flow rate compared with diffuser-nozzle based micropumps.

The Treatment of Adult Respiratory Distress Syndrome (ARDS) Using Extracorporeal Membrane Oxygenation (ECMO) (성인 호흡곤란 증후군에 있어 체외막 산소화 장치를 이용한 치료)

  • Kim, Go-Woon;Choi, Eun-Young;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • 제72권1호
    • /
    • pp.1-7
    • /
    • 2012
  • Extracorporeal Membrane Oxygenation (ECMO) support to tissue oxygenation has been shown to improve survival in patients with life threatening respiratory distress syndrome or cardiac failure. Extracorporeal life support such as ECMO, including extracorporeal $CO_2$ removal ($ECCO_2R$), is used as temporary support until successful recovery of organs. A recently published multicentre randomized controlled trial, known as the CESAR (conventional ventilation or extracorporeal membrane oxygenation for severe adult respiratory failure) trial, was the first trial to demonstrate the utility of ECMO in acute respiratory distress syndrome (ARDS). During the 2009 influenza A (H1N1) pandemic, there were many reports of patients with severe ARDS related to H1N1 infection treated with ECMO. These reports revealed a high survival rate and effectiveness of ECMO. In this review, we explain the indication of ECMO clinical application, the practical types of ECMO, and complications associated with ECMO. In addition, we explain recent new ECMO technology and management of patients during ECMO support.

Isolation and characterization of a noval membrane-bound cytochrome $C_{553}$ from the strictly anaerobic phototroph, heliobacillus mobilis

  • Lee, Woo-Yiel;Bla;Kim, Seung-Ho
    • Journal of Microbiology
    • /
    • 제35권3호
    • /
    • pp.206-212
    • /
    • 1997
  • Heliobacillus mobilis is a strictly anaerobic Gram-positive bacterium which contains a primitive Photosystem I-type reaction center. The membrane-bound cytochrome $C_{553}$ from the heliobacterium suggested to be the immediate electron donor to the photooxidized pigment (P798+) has been isolated and characterized. The heme protein was visualized as a major component with an apparent molecular size of 17kDa in TMBZ-staining analysis of the membrane preparation and showed characteristic $\alpha$ (552.5 nm), $\beta$ (522nm), and Soret absorption (416 nm) peaks of a typical reduced c-type cytochrome in the partially purified sample. The internal 43 amino acid sequence of the electron donor was obtained by chemical agent and protease treatments followed by N-terminal sequencing of the resulting fragments. The internal sequence carries lots of lysine residues and a Cys-X-X-Cys-His sequence motif which are the characteristics of typical c-type cytochromes. The analysis of the sequence by FAST or FASTA program, however, did not show any significant similarity to other known heme proteins.

  • PDF

A Novel Stiff Membrane Seesaw Type RF Microelectromechanical System DC Contact Switch on Quartz Substrate

  • Khaira, Navjot K.;Singh, Tejinder;Sengar, Jitendra S.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권3호
    • /
    • pp.116-120
    • /
    • 2013
  • This paper proposes a novel RF MEMS dc-contact switch with stiff membrane on a quartz substrate. The uniqueness of this work lies in the utilization of a seesaw mechanism to restore the movable part to its rest position. The switching action is done by using separate pull-down and pull-up electrodes, and hence operation of the switch does not rely on the elastic recovery force of the membrane. One of the main problems faced by electrostatically actuated MEMS switches is the high operational voltages, which results from bending of the membrane, due to internal stress gradient. This is resolved by using a stiff and thick membrane. This membrane consists of flexible meanders, for easy movement between the two states. The device operates with an actuation voltage of 6.43 V, an insertion loss of -0.047 dB and isolation of -51.82 dB at 2 GHz.

Shape Finding and Stress Analyses of Tension Membrane Structures by using 4-node Isoparametric Elements (4월점 등매개요소를 이용한 인장막구조(引張膜構造)의 형상해석(形狀解析) 및 응력해석(應力解析))

  • Lee, Kyung-Soo;Lee, Hyung-Hoon;Moon, Jeong-Ho;Han, Sang-Eul
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.222-229
    • /
    • 2004
  • This study purports to analyze equally stressed surfaces in tension-membrane structures through a geometrically nonlinear approach. It adopts the formulation of a 4-node quadrilateral isoparametric plane stress element considering the orthotropic characteristic of membrane textures. Tension structures, which include cables and tension membranes, such as a cable dome initially exhibit unstable conditions because no initial internal stiffness such as bending stiffness is present. Such a structural system requires prestressing to the tension members to attain a stable state. A tension-membrane structure retains a stable three dimensional curved surface as a structural shape. This analytical process for finding the geometry is referred to as Shape Finding Analysis. In order to assess the validity of this study, we examine equally stressed surfaces of saddle and catenary shape shell structures and carry out pertinent stress analyses

  • PDF

A Study on the Optical Internal Recycle Rate and MLSS Concentration of Membrane Coupled $A_2O$ Process for Wastewater Treatment (하수처리를 위한 막결합형 $A_2O$공정에서 최적 내부 순환율 및 MLSS 농도에 관한 연구)

  • Kim Kwan-Yeop;Kim Jin-Mo;Kim Hyung-Soo;Lee Sang-Bek;Park Eugene;Bae Sung-Soo
    • Membrane Journal
    • /
    • 제15권2호
    • /
    • pp.114-120
    • /
    • 2005
  • The purpose of this study is to obtain practical information about membrane coupled $ A_2O$ system for muncipal wastewater treatment. A flat-plate microfiltration (MF) module with a pore size $0.25\;{\mu}m$ was submerged into the aeration basin and treated water was filtrated through the membrane by continuous suction with low pressure. The system was operated with synthetic wastewater to find operational parameters of internal recycle ratio and maximum MLSS showing best water quality and long-term stability. The internal recycle was defined as type 1 for aerobic to anoxic tank and type 2 for anoxic to anaerobic tank, respectively When the flux was maintained at $0.015\;m^3/m^2/hr$ (15 LMH) with 2Q type 1 internal recycle ratio, the optimal operational setting were 10 internal recycle ratio for type 2 and maximum MLSS of 11,000 mg/L among tested conditions. At this condition, removal efficiencies of BOD, CODcr, T-N and T-P showed $97.3\%,\;94.2\%,\;64.0\%,\;63.0\%$, respectively.

Preparation of Forward Osmosis Membranes with Low Internal Concentration Polarization (농도 분극이 저감된 정삼투 분리막 제조)

  • Kim, Nowon;Jung, Boram
    • Membrane Journal
    • /
    • 제24권6호
    • /
    • pp.453-462
    • /
    • 2014
  • Thin film composite (TFC) polyamide (PA) membranes were prepared on polyester (PET) nonwoven reinforced polysulfone supports for forward osmosis (FO) processes. PSF (polysulfone) supports were prepared via the phase inversion process from PSF casting solutions in dimethyl formamide (DMF) solvents (19 wt%) by using a PET nonwoven (thickness of $100{\mu}m$) as a mechanical reinforcing material for reverse osmosis (RO) membrane. The PSF support from 19 wt% of DMF/PSF casting solution showed sponge-like morphology and asymmetric internal structure. To reduce the internal concentration polarization in FO operation, thin ($20{\mu}m$ of thickness) nonwoven-supported PSF supports were prepared by using PSF/DMF casting solution (9~19 wt%). A desirable support structure with a highly porous sponge-like morphology were achieved from the thin nonwoven-supported PSF layer prepared with 9~12 wt% casting solution. A crosslinked aromatic polyamide layer was fabricated on top of each support to form a TFC PA membrane. The tested sample from 12 wt% of DMF/PSF casting solution presented outstanding FO performance, almost 5.5 times higher water flux (24.3 LMH) with low reverse salt flux (RDF, 1.5 GMH) compared to a thick nonwoven rainforced membrane (4.5 LMH of flux and 3.47 GMH of RSF). By reducing the thickness of the nonwoven and optimizing PSF concentration of casting solution, the morphology of the prepared membranes were changed from a dense structure to a porous sponge structure in the boundary area between nonwoven and PET support layer.

Multi- effect air gap membrane distillation process for pesticide wastewater treatment

  • Pangarkar, Bhausaheb L.;Deshmukh, Samir K.;Thorat, Prashant V.
    • Membrane and Water Treatment
    • /
    • 제8권6호
    • /
    • pp.529-541
    • /
    • 2017
  • A multi-effect air gap membrane distillation (ME-AGMD) module for pesticide wastewater treatment is studied with internal heat recovery, sensible heat of brine recovery, number of stages and the use of fresh feed as cooling water in a single module is implemented in this study. A flat sheet polytetrafluroethylene (PTFE) membrane was used in the 4-stage ME-AGMD module. The maximum value of permeate flux could reach $38.62L/m^2h$ at feed -coolant water temperature difference about $52^{\circ}C$. The performance parameter of the module like, specific energy consumption and gain output ratio (GOR) was investigated for the module with and without heat recovery. Also, the module performance was characterized with respect to the separation efficiency of several important water quality parameters. The removal efficiency of the module was found to be >98.8% irrespective water quality parameters. During the experiment the membrane fouling was caused due to the deposition of the salt/crystal on the membrane surface. The membrane fouling was controlled by membrane module washing cycle 9 h and also by acidification of the feed water (pH=4) using 0.1M HCl solution.

Performance Evaluation of a Plate-Type Membrane Humidifier for PEMFC (고분자전해질연료전지용 판형막가습기 성능 평가)

  • Kho, Back Kyun;Park, JongCheol;Han, In-Su;Shin, Hyun Khil;Hur, Tae Uk;Cho, Sungbaek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.98.2-98.2
    • /
    • 2011
  • For optimal performance of a proton exchange membrane fuel cell (PEMFC), the membrane electrode assembly (MEA) requires hydration, and the membrane's conductivity depends on water content. A humidifier is required to ensure that the reactant gas, usually hydrogen and air, is hydrated before entering the fuel cell. Dry membrane operation or improper hydration causes performance degradation. Typically, the humidification of a fuel cell is carried out by means of an internal or external humidifier. A membrane humidifier is applied to the external humidification of transportation or residential power generation fuel cell due to its convenience and high performance. In this study, The experiments were constructed with a plate-type membrane humidifier in terms of geometric parameters and operating parameters. The results show that the temperature and pressure, the channel length, the membrane thickness and gas flow rate are critical parameters affecting the performance of the humidifier.

  • PDF