• 제목/요약/키워드: Internal insulation

검색결과 230건 처리시간 0.026초

폴리머 피뢰기의 구조에 따른 온도와 누설전류 특성 (Temperature and Leakage Current Characteristics of Polymeric Surge Arrester with Housing)

  • 조한구;유대훈;이운용;김하나
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.273-280
    • /
    • 2007
  • In this paper, the ZnO surge arrester performance of power distribution class has been studied under different manufacturing conditions such as housing materials(polymeric, porcelain), interface sealants and one-body molding type. In the recent years, the polymeric ZnO surge arresters have been developed and put into operations based on their excellent characteristics. For polymeric surge arresters, the inner gas volume is extremely small, especially in solid insulation polymeric arresters there are not any gas volume inside arresters in the structure due to polymeric materials are filled into the internal gas volume. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters is investigated with moisture multi-aging test and ingress test. The evaluation techniques are used to inspect the sealing integrity of polymeric arresters, including leakage current, surface temperature, reference voltage and dissipation factor.

전기자동차용 배터리 충전기 (Battery Charger for EV)

  • 윤수영;채형준;김원용;문형태;정유석;이준영
    • 전력전자학회논문지
    • /
    • 제15권6호
    • /
    • pp.460-465
    • /
    • 2010
  • 최근 화석 연료의 고갈과 이산화탄소 배출 제한으로 인하여 내연기관 자동차에서 전기 자동차로의 대한 관심이 높아지고 있다. 전기 자동차 에너지 저장 요소인 배터리 충전에 필요한 AC-DC 컨버터가 필요하며 컨버터의 필요조건 으로 넓은 출력 전압 범위, 고효율, 높은 역률 등을 들수 있다. 넓은 전압 범위와 절연을 위해 2단 구성 하였다. 앞단은 LLC 컨버터를 후단은 역률을 고려 하여 BOOST 컨버터를 이용한 PFC 회로를 구현하여 실험적으로 확인 하였다.

Hall voltage measurement with respect to internal layout of REBCO coated conductors in an external magnetic field

  • Kim, Young Gon;Baek, Geonwoo;Han, Seunghak;Choi, Yojong;Kim, Junseong;Jeon, Haeryong;Ko, Tae Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권4호
    • /
    • pp.48-52
    • /
    • 2019
  • Recently, many studies have been reported on the magnetoresistance and Hall effect of REBCO thin films and bulk. The voltage interferes quench detection of high-temperature superconducting magnet and generates leakage current in no insulation high-temperature superconducting coil. Therefore, in this paper, experiments on magnetoresistance and Hall effect of commercial YBCO and GdBCO tapes have been carried out. As a result, anomalous voltages expected for the magnetoresistance and Hall effect of REBCO tapes were observed and analyzed. In addition, the voltage characteristics of REBCO have been identified, and the Hall coefficient are calculated for use in high magnetic field magnet applications.

GIS 스페이서에 파티클 부착시 연면방전과 전계해석 (Numerical Analysis of Surface Discharge due to Particles Attached to the GIS spacer)

  • 장덕근;이재화;곽희로;박하용;김영찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1788-1790
    • /
    • 2003
  • GIS is a typical power equipment with higher reliability. It is compact and safe because all the energized parts are enclosed by a sealed cylindrical tank which is filled with $SF_6$. Generally gas insulated power equipments like GIS are designed to have sufficient electrical strength to prevent partial discharges under normal operating condition. Despite of the careful processes in manufacturing, transporting and assembling, voids or particles can be created, resulting in partial discharges at electrically weak points. The key factors causing partial discharges in GIS are; particles, voids in solid insulation, protrusions, poor contact of metal components, etc. The particle can be attached on; spacers, electrodes, internal wall of the GIS tank. It also moves in GIS freely. Most of partial discharges are likely to occur when particles are attached to spacers. In this paper, the electrical characteristics of a surface discharge were investigated under various conditions by using simulation program of FEMLAB.

  • PDF

신경회로망 및 ${\Delta}F$를 이용한 부분방전 패턴인식에 관한 연구 (A Study on the Pattern Recognition Using of HFPD the Neural Networks and ${\Delta}F$)

  • 임장섭;김덕근;김진국;노성호;김현종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.251-254
    • /
    • 2004
  • The aging diagnosis technique using partial discharge detection method detects partial discharge signals cause of power equipment failuer and able to forecast the aging state of insulation system through analysis algorithm, in this paper accumulates HFPD signal during constant scheduled cycles to build HFPD pattern and then analyzes HFPD pattern using statistical parameters and ${\Delta}F$ pattern. The 3D pattern is composed of detected signal frequency, amplitude and repeated number and the FRPDA(frequency resolved partial discharge analysis) technique is used in 3D pattern construction. The ${\Delta}F$ pattern shows variation characteristics of amplitude gradient of consecutive HFPD signal Pulses and able to classify discharge types-internal discharge, surface discharge and coronal discharge etc. Fractal mathematics applied to ${\Delta}F$ pattern quantification and neural networks is used in aging diagnostic algorithm.

  • PDF

공랭식 가스터빈 발전기의 운전중 부분방전 분석 (Analysis of On-Line Partial Discharge in Air-Coolded Gas Turbine Generator)

  • 이은춘;공태식;김재철;김희동
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.41-47
    • /
    • 2014
  • The on-line partial discharge (PD) in stator windings of air-cooled gas turbine (GT) generator (119.2MVA, 13.8kV) is measured and analyzed in this paper. This generator was designed by global vacuum pressure impregnation (VPI). The generator failed two times at top bar (16T) of phase B in the stator slot. Six epoxy-mica capacitors were installed in three phases of GT generator. On-line PD test was performed on GT generator using turbine generator analyzer (TGA). TGA showed that the normalized quantity number (NQN) and the PD magnitude($Q_m$) were high in phase B. Internal discharges were generated in phases A, B and C. The trend analysis of NQN and $Q_m$ value are obtained in order to monitor the insulation condition in GT generator stator windings. Phases A and C were in good condition. But phase B had deteriorated significantly

저밀도 폴리에틸렌에 있어서 전압 파형의 두께 의존성 (Film Thickness Dependences of Ac High Field Dissipation Current Waveform for LDPE)

  • 윤주호;최용성;문종대;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.349-350
    • /
    • 2007
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

Numerical analysis on the behaviour of reinforced concrete frame structures in fire

  • Dzolev, Igor M.;Cvetkovska, Meri J.;Ladinovic, Dorde Z.;Radonjanin, Vlastimir S.
    • Computers and Concrete
    • /
    • 제21권6호
    • /
    • pp.637-647
    • /
    • 2018
  • Numerical approach using finite element method has been used to evaluate the behaviour of reinforced concrete frame structure subjected to fire. The structure is previously designed in accordance with Eurocode standards for the design of structures for earthquake resistance, for the ductility class M. Thermal and structural response are obtained using a commercially available software ANSYS. Temperature-dependent nonlinear thermal and mechanical properties are adopted according to Eurocode standards, with the application of constitutive model for the triaxial behaviour of concrete with a smeared crack approach. Discrete modelling of concrete and reinforcement has enabled monitoring of the behaviour at a global, as well as at a local level, providing information on the level of damage occurring during fire. Critical regions in frame structures are identified and assessed, based on temperatures, displacements, variations of internal forces magnitudes and achieved plastic deformations of main reinforcement bars. Parametric analyses are conducted for different fire scenarios and different types of concrete aggregate to determine their effect on global deformations of frame structures. According to analyses results, the three-dimensional finite element model can be used to evaluate the insulation and mechanical resistance criteria of reinforced concrete frame structures subjected to nominal fire curves.

동시소성형 감전소자의 개발 (Development of Heterojunction Electric Shock Protector Device by Co-firing)

  • 이정수;오성엽;류재수;유준서
    • 한국재료학회지
    • /
    • 제29권2호
    • /
    • pp.106-115
    • /
    • 2019
  • Recently, metal cases are widely used in smart phones for their luxurious color and texture. However, when a metal case is used, electric shock may occur during charging. Chip capacitors of various values are used to prevent the electric shock. However, chip capacitors are vulnerable to electrostatic discharge(ESD) generated by the human body, which often causes insulation breakdown during use. This breakdown can be eliminated with a high-voltage chip varistor over 340V, but when the varistor voltage is high, the capacitance is limited to about 2pF. If a chip capacitor with a high dielectric constant and a chip varistor with a high voltage can be combined, it is possible to obtain a new device capable of coping with electric shock and ESD with various capacitive values. Usually, varistors and capacitors differ in composition, which causes different shrinkage during co-firing, and therefore camber, internal crack, delamination and separation may occur after sintering. In addition, varistor characteristics may not be realized due to the diffusion of unwanted elements into the varistor during firing. Various elements are added to control shrinkage. In addition, a buffer layer is inserted in the middle of the varistor-capacitor junction to prevent diffusion during firing, thereby developing a co-fired product with desirable characteristics.

컨테이너형 ESS 화재방지를 위한 내부 응결점 개선 관한 연구 (Study on Improvement of Dew Point within ESS Container for Fire Prevention)

  • 김운학;강석원;신기석
    • 한국재난정보학회 논문집
    • /
    • 제15권2호
    • /
    • pp.165-174
    • /
    • 2019
  • 연구목적: 본 연구에서는 제안되는 ESS 컨테이너 화재사고의 원인들에 대한 상관관계를 확인하였다. 연구방법: 이들의 개선에 필요한 컨테이너 내부의 환경개선을 통하여 컨테이너 화재사고의 저감 가능성에 대한 조사를 시행하였다. 연구결과: 본 연구를 통해 내 외부 온도차에 발생되는 수분응결 조건의 개선과 이를 통한 BMS board의 절연 내력의 변화가 있음을 확인하였다. 연구결론: BMS Board 응결과 절연 내력저하와의 상관 관계를 확인하였다.