• Title/Summary/Keyword: Internal displacement

Search Result 538, Processing Time 0.027 seconds

Effect of gravity on a micropolar thermoelastic medium with voids under three-phase-lag model

  • Alharbi, Amnah M.;Othman, Mohamed I.A.;Al-Autabi, Al-Anoud M.Kh.
    • Structural Engineering and Mechanics
    • /
    • v.76 no.5
    • /
    • pp.579-590
    • /
    • 2020
  • This paper's objective is to investigate the effect of gravity on a micropolar thermoelastic medium with voids. The problem is assessed according to the three-phase-lag model. An analysis of the resulting non-dimensional displacement, temperature variation, and internal stress of the study material is carried out and presented graphically. The non-dimensional displacement, temperature, micro-rotation, the change in the volume fraction field and stress of the material are obtained and illustrated graphically. Comparisons are made with the results predicted by different theories for different values of gravity, the phase-lag of the heat flux and the phase-lag of the temperature gradient. The numerical results reveal that gravity and relaxation times have a significant influence on the distribution of the field quantities. Some notable insights of interest are deduced from the investigation.

Factors Influencing the Duration of Occlusal Appliance Treatment for Patients with Temporomandibular Joint Internal Derangement

  • Lee, So-Youn;Byun, Jin-Seok;Jung, Jae-Kwang;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.41 no.3
    • /
    • pp.110-117
    • /
    • 2016
  • Purpose: The purpose of this study is to determine factors influencing the duration of occlusal appliance (OA) treatment for patients with temporomandibular joint (TMJ) internal derangement. Methods: Ninety patients were included for this study, who satisfied the following including criteria: (i) those who were diagnosed as disc displacement of TMJ by taking magnetic resonance imaging (MRI) and (ii) those who were finished OA treatment. The subjects were classified into three groups according to the period of OA treatment: (i) early response group (<6 months), (ii) moderate response group (6 months-1 year), and (iii) delayed response group (>1 year). Demographic data, data from chief complaints and past history of temporomandibular disorder, data from clinical examination and diagnostic imaging including panoramic view and TMJ MRI were compared among groups. One-way ANOVA and chi-square analysis were used to test statistical significance. Results: There were no significant differences in demographic data, data from chief complaints and TMJ imaging. However, only the prevalence of oral parafunctional habits including bruxism, clenching, and unilateral chewing showed significant differences among groups. Conclusions: Oral parafunctional habits could be factors to influence the duration of OA treatment in the patients with TMJ internal derangement.

Effect of Ceramic-Electrode Interface on the Electrical Properties of Multilayer Ceramic Actuators (적층형 세라믹 액츄에이터의 세라믹-전극간 계면이 전기적 특성에 미치는 영향에 대한 연구)

  • 하문수;정순종;송재성;이재신
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.896-901
    • /
    • 2002
  • The polarization and strain behavior of multilayer ceramic actuators fabricated by tape casting using a PNN-PZT ceramics were investigated in association with electrode size and internal layer number. Spontaneous polarization and strain decreased with increasing electrode size. In addition, the increase of internal layer number brought reduced spontaneous polarization and increased the field-induced strain. Because the actuators structure is designed to stack ceramic layer and electrode layer alternatively, the ceramic-electrode interfaces may act as a resistance to motion of domain wall. To analyze the effect of ceramic-electrode interface, the diffraction intensity ratio of (002) to (200) planes was calculated from X-ray diffraction patterns of samples subjected to a voltage of 200 V. The diffraction intensity ratio of (002) to (200) planes was decreased with increasing electrode size and internal layer number. The diffraction intensity ratio and straining behavior analyses indicate that the Polarization and strain were affected by the amount of 90°domain decreasing with increasing electrode size and internal layer number. Consequently, the change of polarization and displacement with respect to electrode size and layer number is likely to be caused by readiness of the domain wall movement around the interface.

Analysis of the Internal Forces of the Rail Supports for the Serviceability of Concrete Slab Track Bridge (콘크리트 슬래브 궤도 교량의 사용성 검토를 위한 레일 지지점에서의 작용력 해석)

  • Choi, Jun-Hyeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1303-1313
    • /
    • 2013
  • In this study, the reference values for the internal forces of the rail supports caused by a wheel load, a unit vertical displacement, a unit end rotation in examination of the serviceability of concrete slab track bridge were obtained. In analysis, the analysis models of which the rail was continuously and discretely supported by elastic springs were used. The internal forces of the rail supports from the analysis were compared with the results provided in the DS 804 regulations and agreed with well. In addition, the effects of the space between the rail supports and the stiffness of fastener on the internal forces of the rail supports were investigated.

A Study on Measurement of Internal Defects of Pressure Vessel by Digital Shearography and Finite Element Method (전자 전단 간섭법과 유한요소법을 이용한 압력용기의 내부결함 측정에 관한 연구)

  • 강영준;강형수;채희창
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.2
    • /
    • pp.29-37
    • /
    • 2001
  • The application of laser in pipelines was started from the base of using laser in nuclear facilities industries and power plants. Because laser can be delivered to a remote area without any difficulties, the application of laser in many industries can solve many difficulties from limitation of access in danger area and reduced the risks of workers. Therefore, we developed a new experimental technique to measure internal defects of pressure vessels with a combination of shearog-raphy and image processing technique. Conventional NDT methods have been taken relatively much time, money and manpower because of performing as the method of contact with objects to be inspected. But digital shearography is laser-based optical method which allows full-field observation of surface displacement derivatives. This method has many advantages in practical use, such as low sensitivity to environmental noise, simple optical configuration and real time mea-surement. In this paper, we find the optimum shearing magnitude with EFM and experiment and measured internal crack length of the pressure vessels at a real time and estimated the error of the results.

  • PDF

New Engineering J and COD Estimation Methods for Axial Through-Wall Cracked Pipes (축방향 관통균열 배관의 새로운 탄소성 J-적분 및 COD 계산식)

  • Huh, Nam-Su;Park, Young-Jae;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.2
    • /
    • pp.239-246
    • /
    • 2003
  • This paper proposes engineering estimation equations of elastic-plastic J and COD fur axial through-wall cracked pipes under internal pressure. Based on detailed 3-D FE results based on deformation plasticity, the plastic influence functions for fully plastic J and COD solutions are tabulated as a function of the mean radius-to-thickness ratio, the normalized crack length. and the strain hardening. Based on these results, the GE/EPRI-type J and COD estimation equations are proposed and validated against the 3-D FE results based on deformation plasticity. For more general application to general stress-strain laws or to complex loading, the developed GE/EPRI-type solutions are re-formulated based on the reference stress concept. Such a reformulation provides simpler equations for J and COD, which are then further extended to combined internal pressure and bending. The proposed reference stress based J and COD estimation equations are compared with elastic-plastic 3-D FE results using actual stress-strain data for Type 316 stainless steels. The FE results for both internal pressure cases and combined internal pressure and bending cases compare very well with the proposed J and COD estimations.

Enhanced Photocatalytic Activity by the Combined Influence of Ferroelectric Domain and Au Nanoparticles for BaTiO3 Fibers

  • Zhang, Xiaoshan;Huan, Yu;Zhu, Yuanna;Tian, Hui;Li, Kai;Hao, Yanan;Wei, Tao
    • Nano
    • /
    • v.13 no.12
    • /
    • pp.1850149.1-1850149.10
    • /
    • 2018
  • Ferroelectric particles have been applied in the photocatalytic field because the spontaneous polarization results in the internal electric field, which can accelerate the separation and migration of photogenerated carriers. In this study, the $BaTiO_3$ (BT) fibers are synthesized by electrospinning. The BT fibers calcined above $800^{\circ}C$ exhibit a strong ferroelectric property, which is verified by a typical butterfly-shaped displacement-voltage loop. It is found that the BT fibers with the single-domain structure exhibit better photocatalytic performance than that with the multi-domain configuration. When the single-domain transforms into multi-domain, the integrated internal electric field correspondingly breaks up, inducing that the internal electric field might cancel each other out and diminish the separation of photogenerated carriers. Also, the Au nanoparticles can improve the photocatalytic activity further on account of the surface plasmon resonance. Therefore, it is suggested that Au nanoparticles decorated on ferroelectric BT nanomaterials are promising photocatalysts.

Concept and application of implant connection systems: Part I. Placement and restoration of internal conical connection implant (임플란트 연결부의 개념과 적용: Part 1. 원추형 내부연결 임플란트의 식립과 보철)

  • Ko, Kyung-Ho;Kang, Hyeon-Goo;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.211-221
    • /
    • 2020
  • The typical biomechanical properties of an internal conical connection (ICC) are axial displacement and loss of preload. The axial displacement of an ICC without a vertical stop can cause the loss of preload and a lowered occlusion. The stress of an ICC is concentrated on the contact interface of the abutment and not on the screw, and during placement, it is important to choose a wider coronal wall thickness as much as possible. The ICC should also be placed below the level of the bone crest. During the restoration of an ICC, care should be taken to ensure an appropriate abutment shape and an accurate connection. To get the best clinical results, it is important to select its wall thickness and place it in the appropriate position to restore it adequately.

Dose perturbation measurements during the liver treatment with internal organ motion: Mathematical modeling and Experimental simulation (호흡에 의한 내부 움직임의 영향이 있는 간에서의 실험적 선량 측정)

  • Chung, Jin-Bum;Kim, Yon-Lae;Chung, Won-Kyun;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.115-118
    • /
    • 2004
  • Respiratory motion in the thorax and abdomen is an important limiting factor in high-precision radiation therapy. The lung tumor and tumor(pancreas, stomach) in abdomen therefore are internal motion due to breathing. We will perform to measurement of dose distributions for these moving tumors. In preliminary study, we investigated displacement of moving tumor such as liver, lung tumor in abdomen with previously reported papers. With reference data, internal movements of tumor are displayed with phantom and moving control device(MCD), which appear three dimension (3-D) motion such as x, y and z axis. These devices are used to access dose delivered in tumor with and without internal motion. The MCD and phantom were used to evaluate a delivered dose under similar condition, although there are not same internal tumor motion. In future, we will obtain the exact evaluation of dose if improved in programed software of moving control device and measure precise internal motion using image modality such as fluoroscopy, simulator in based on this study.

  • PDF

Evaluation of Extraosseous Abnormalities Detected in Bone Scan ($^{99m}Tc-Methylene$ Diphosphonate (MDP)골(骨)스캔에서 골격외(骨格外) 섭취(攝取) 및 신요로계(腎尿路系) 이상소견(異常所見)에 관(關)한 연구(硏究))

  • Rhim, Sang-Moo;Park, Ran-Jae;Kim, Byung-Tae;Lee, Myung-Chul;Cho, Bo-Yeon;Lee, Hong-Kyu;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.1
    • /
    • pp.31-39
    • /
    • 1982
  • The purpose of the present study is to evaluate the clinical and diagnostic significance of incidental findings of renal and urinary tract abnormalities, and extraosseous uptake of bone scans. The authors analyzed bone scans using $^{99m}Tc-MDP$(methylene diphosphonate) in 1238 cases of bone disease from April, 1979 to March, 1981. The results obtained were as follows. 1. Total extraosseous abnormalities were 112 cases (9%), which include 64 cases (5%) of renal and urinary tract abnormalities and 48 case(4%) of other extraosseous uptakes. 2. Renal and urinary tract abnormalities were 32 cases(50%) of obstruction, 14 cases(22%) of nonvisualization, 6 cases of space occupying lesion in kidney, 8 cases of kidney displacement and 4 cases of urinary bladder deformities. 3. Other extraosseous uptakes were 16 cases (33%) of body fluid collection, 15 cases of tumor uptake, 9 cases of free pertechnetate uptake and 8 others.

  • PDF