• 제목/요약/키워드: Internal components

검색결과 1,040건 처리시간 0.026초

A Case of Mixed Germ Cell Tumor of the Mediastinum (종격동에 발생한 혼합생식세포종양 1예)

  • Cho, Wook;Han, Min Soo;Kim, Kil Dong;Kim, Sung Ho;Kim, Jun Hyoung;Lee, Yang Deok;Cho, Yong Seon
    • Tuberculosis and Respiratory Diseases
    • /
    • 제58권2호
    • /
    • pp.184-187
    • /
    • 2005
  • The Mixed germ cell tumors of the mediastinum are very quite rare. The Prognosis is generally dominated by the most aggressive component, which is represented by a choriocarcinoma, an endodermal sinus tumor, an embryonal carcinoma, and a seminoma, in descending order of in the degree of malignancy. We experienced one a case of a mixed germ cell tumor at the anterior mediastinum. The patient was 27-year-old male, who complained of hemoptysis and cough. The Chest X-ray showed a well-defined lobulated mediastinal mass in the left upper lung field. The operation was done and The mass was excised surgically. A Biopsy showed elements of mature tissues, immature neuronal components, and seminoma components.

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제43권3호
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.

Effects of High Temperature-moisture on Corrosion and Mechanical Properties for Sn-system Solder Joints (고온고습환경이 Sn계 무연솔더의 부식 및 기계적 특성에 미치는 영향)

  • Kim, Jeonga;Park, Yujin;Oh, Chul Min;Hong, Won Sik;Ko, Yong-Ho;Ahn, Sungdo;Kang, Namhyun
    • Journal of Welding and Joining
    • /
    • 제35권3호
    • /
    • pp.7-14
    • /
    • 2017
  • The effect of high temperature-moisture on corrosion and mechanical properties for Sn-0.7Cu, Sn-3.0Ag-0.5Cu (SAC305) solders on flexible substrate was studied using Highly Accelerated Temperature/Humidity Stress Test (HAST) followed by three-point bending test. Both Sn-0.7Cu and SAC305 solders produced the internal $SnO_2$ oxides. Corrosion occurred between the solder and water film near flexible circuit board/copper component. For the SAC305 solder with Ag content, furthermore, octahedral corrosion products were formed near Ag3Sn. For the SAC305 and Sn-0.7Cu solders, the amount of internal oxide increased with the HAST time and the amount of internal oxides was mostly constant regardless of Ag content. The size of the internal oxide was larger for the Sn-0.7Cu solder. Despite of different size of the internal oxide, the fracture time during three-point bending test was not significantly changed. It was because the bending crack was always initiated from the three-point corner of the chip. However, the crack propagation depended on the oxides between the flexible circuit board and the Cu chip. The fracture time of the three-point bending test was dependent more on the crack initiation than on the crack propagation.

The Effect of Servicescape and Human Service Quality on Patients' Internal Responses and Their Behavioral Intention in Dental Care Organizations (치과 의료기관의 서비스스케이프와 인적서비스품질이 환자의 내적반응 및 행동의도에 미치는 영향)

  • Cheon, Mi Ok;Kim, Jiwon;Bae, Sung Yoon
    • Korea Journal of Hospital Management
    • /
    • 제22권4호
    • /
    • pp.1-15
    • /
    • 2017
  • This study was designed to analyze the effect of servicescape and human service quality on patients' internal response and their behavioral intention in dental care organizations. Self-administered survey questionnaires with structured instruments were developed, and a total of 226 responses were used for statistical analyses using SPSS Windows version 18.0 program and AMOS 18.0 program. Major findings of the study are as follows. First, among other servicescape components, air condition environment was found to have a positive effect on patients' cognitive and physiological responses, while signals and symbols had a positive effect on cognitive and emotional responses. Second, the competence, among other factors of the human service quality, had positive influence on cognitive and emotional responses, while customer understanding affected positively on emotional response. Third, none of the servicescape components showed a direct effect on patients' behavioral intention, but their influence was mediated by internal responses. However, customer understanding, among other human service quality factors, had a direct effect on patients' behavioral intention. Fourth, emotional response, among other internal response factors, proved to have positive influence on behavioral intention. Results from this study suggest that dental care service providers can increase their competitiveness and customer satisfaction by understanding and improving the most important areas of servicescape and human service quality.

Factors Affecting Quality of Internal Control: A Case Study of Listed Banks in Vietnam

  • TRAN, Quoc Thinh;NGUYEN, Khanh Tuan;LE, Xuan Thuy
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권5호
    • /
    • pp.375-380
    • /
    • 2021
  • Internal control is important for monitoring operations of organizations. In order to achieve the quality of internal control, organizations need to recognize different perspectives in which the components of internal control play a decisive role. Internal control is a process designed by the manager and it is applied within the organization to provide reasonable assurance of the reliability of financial information and to comply with policies, procedures, rules, regulations and laws. The article uses the ordinary least squares method and the seven-point Likert scale to test the variables affecting the quality of internal control in 18 Vietnamese listed banks. The article surveyed 179 leaders of listed banks. The results show that there are three variables out of a total of five variables that positively affect the quality of internal control, including the control environment, control activities, and monitoring. Accordingly, the managers of Vietnamese listed banks need to pay attention to building a corporate culture environment, improve the quality of control activities, and periodically and regularly conduct the monitoring. It contributes to improving the quality of internal control and is also an opportunity to increase economic benefits for Vietnamese listed banks in the context of international economic integration.

A Qualitative Study on the Internal Marketing of Fashion Companies in the Omni Channel Fashion Distribution Environment -Focused on the Woman's Clothing Salesperson- (옴니채널 유통환경에서 패션기업의 내부마케팅 구성요인 -여성복 판매원을 중심으로-)

  • Jungjin Lee
    • Journal of Fashion Business
    • /
    • 제27권1호
    • /
    • pp.16-35
    • /
    • 2023
  • The advent of Omni Channel has changed the fashion business model and the role of fashion sales persons. In such situation, internal marketing can become an important organizational management strategy for fashion companies. Therefore, the purpose of this study is to identify the components of internal marketing of fashion companies for fashion shop masters in an omni channel environment. To achieve the purpose of this study, To achieve the purpose of this study, a qualitative study was conducted to investigate the internal marketing sub-factors of fashion companies. In-depth interviews were conducted for qualitative study. Seven respondents to the in-depth interview were fashion shop masters who had at least 10 years of field work experience. As a result of the qualitative study, internal marketing was derived from five factors, including empowerment, education and training, rewards, internal communication, and management supports. Empowerment factors consist of initiative, encourage creativity, and problem solving. Education and training factors consist of the degree of education and training opportunities, the value of education and training, and the scope of education and training. Rewards factors consist of diversity of rewards, fairness of rewards, and source of rewards. Internal communication factors consist of communication flexibility, diversity of communication and receptivity of communication. Management support factors consist of headquarters support and department store support.

Analysis of Bronchoalveolar Lavage Fluid cells from the Patients of Diffuse Interstitial Lung Diseases (미만성 간질성 폐질환에서 기관지 폐포세척액내의 세포 검사)

  • Kim,, Hyo-Seok;Moon, Soo-Nam;Cheong, Seung-Whan;Lee, Sang-Moo;Kim, Hyeon-Tae;Lee, Guang-Cho;Uh, Soo-Taek;Kim, Yong-Hoon;Park, Choon-Sik;Jin, Byung-Won
    • Tuberculosis and Respiratory Diseases
    • /
    • 제41권6호
    • /
    • pp.604-615
    • /
    • 1994
  • Background: Analysis of cells in bronchoalveolar lavage(BAL) fluid had been used to predict the histologic changes of the bronchioles and alveoli in patients with interstitial lung diseases(ILD). Definitive diagnosis can be a1so made in some cases of ILD, such as histiocytosis. However, there are a few data of the cellular components in BAL fluid in normal Korean individuals and in patients with ILD. In order to evaluate the role of the cellular analysis of BAL fluid in prediction of alveolitis and differential diagnosis among ILDs, we compared the cellular components in BAL fluid from 50 normal individuals and 86 ILD patients. Method: BAL was performed by instillation and retrievement of normal saline with fiberoptic bronchoscopy. The cell number was counted by Hemocytometer. Differential count was done up to 500 cells on slides prepared by Diff-Quik stain and non-specific esterase stain. We compared the recovery rate(RR), cell numbers(CN), and percentages of each cellular components(CP). Results: The results were as follows: 1) There was no difference in RR, CN and CP between the normal smoker group and normal non-smoker group. 2) Total cell numbers recoverd in BAL fluid increased in collagen vascular diseases(CVD), hypersensitivity pneumonitis(HP), idiopathic pulmonary fibrosis(IPF), and miliary tuberculosis(Mil TBC) groups. 3) The percentage of lymphocytes increased in HP, IPF and Mil TBC groups. Macrophage percentages increased in HP, IPF, and Mil TBC groups. Neutrophil percentages were increased in CVD, HP, IPF and Mil TBC groups. Eosinophil percentages were increased in HP, IPF and Mil TBC groups. The numbers of each cells showed same findings as the percentages did. Conclusion: The analysis of cellular components of BAL fluid can predict the presence of alveolitis in many cases of ILDs. However, It was not helpful in differential diagnosis among ILDs.

  • PDF

Mediation Effect of Appearance Management Behavior on the Relationship between Satisfaction of Personal Image and Job Search Efficacy among Female College Students (여대생의 퍼스널 이미지 만족도와 구직효능감과의 관계에서 외모관리행동의 매개효과)

  • Kim, Mikyung
    • Journal of Fashion Business
    • /
    • 제22권4호
    • /
    • pp.160-177
    • /
    • 2018
  • The objective of this study was to investigate mediation effect of appearance management behavior on the relationship between satisfaction of personal image and job search efficacy. Based on previous studies on components of personal image, appearance management behaviors, and job search efficacy, questionnaire items were developed. For this study, we conducted a questionnaire survey among 422 students from women's university in Seoul. Statistical analyses were performed using SPSS 23. Results are as follows. First, there were positive and moderate bivariate correlations among satisfaction of personal image, appearance management behavior, and job search efficacy. Second, satisfaction of personal image was found to have a partially significant effect on job search efficacy while satisfaction of internal image, visual image, and social image had a positive effect on job search skill. Satisfaction of internal image had a positive effect on job search strength. However, satisfaction of visual image or social image did not have a significant effect on job search strength. Third, fashion management behavior among components appearance management behavior could partially mediate the relationship between satisfaction of personal image and job search efficacy, indicating that satisfaction of internal image and visual image among components personal image not only has a direct effect on job search skill among job search efficacy, but also has an indirect effect on job search skill by affecting fashion management behavior. These results suggest that it is important to build personal image effectively and increase satisfaction with oneself through active appearance management behavior to improve job search efficacy.

EFFECT OF GIBBERELLIN ON THE GROWTH AND INTERNAL COMPONENTS OF SELECTED VEGETABLE PLANTS (재배식물의 생육 및 성장에 미치는 지베레린의 영향)

  • CHA, Jong Whan
    • Journal of Plant Biology
    • /
    • 제5권3호
    • /
    • pp.11-20
    • /
    • 1962
  • CHA, Jong Whan (Dept. of Biology, Coll. of Education, Seoul National Univ.) Effect of Gibberelline on the growth and internal components of selected vegetable plants. Kor. Jour. Bot. V(3):11-20, 1962. The effect of GA on the growth as well as on the internal components of theleaves of ordinary vegetable plants under the soil culture was investigated. A relatively small difference in GA concentration applied showed a marked influence on the growth and constituents of the plants observed. The increase of growth was related to a highly significant digree with the intensity of GA. chlorophyll and carotene content in the leaves were significantly with increasing concentration of GA, except for some plants. The growth in all examined plants did not correspond to the contents of chlorophyll and carotene. In contrast the ascorbic acid in the leaves treated with GA decreased in proportion to the GA concentrations. Chlorophyll and ascorbic acid value differed greatly during the two experiments and the difference was proved significant. Carotene content varied with chlorophyll although the ratio of chlorophuyll to carotene was not so high as that obtained by Beak and Redman.

  • PDF

Analysis of CD stud welding process and defects (CD 스터드 용접공정의 해석 및 결함 분석)

  • O, Hyeon-Seok;Yu, Jung-Don
    • Proceedings of the KWS Conference
    • /
    • 대한용접접합학회 2005년도 추계학술발표대회 개요집
    • /
    • pp.55-57
    • /
    • 2005
  • In this study, modeling of the CD stud welding system was conducted considering mechanical and electrical components. The electrical components such as arc resistance, cable resistance, capacitance, internal resistance and cable inductance were found to affect the output waveform significantly. The calculated results showed food agreements with the experiment results within 20% error. The main defect of CD stud welding with 1010 steel stud and SS400 steel plate was the void trapped between stud and base metal. The effect of the spring force and stud tip size on void formation was investigated.

  • PDF