• Title/Summary/Keyword: Internal and External Characteristics

Search Result 873, Processing Time 0.027 seconds

A Study of Property on Trilateral Elevation in the Acute Angle Site

  • CHO, JAE-HEE
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.22-27
    • /
    • 2021
  • Morphology of contemporary city streets is composed of overlapping infrastructures corresponding to the new street within the established organization, contemporary system, future circumstance, and population. As well, two overlaid organizations and morphological, historical, social and physical development lead to sharp acute algle(triangular) site, and the architecture in this site has a restriction on the availability of the internal space and the external design due to outside shape sharpness. We want to have a positive effect on the internal and external design of the architecture in the future by categorization of the shape and processing characteristics of the acute angle corner of the trilateral site. The characteristics and design categorization shown in this case study are as follows. Constitution a unique and independent form, lead streets and shape a exclusive image of the landscape, alleviate sharpness by configuring a acute angle point as a plane, use void to give reserve character, replace roundness for companionability to induce ambience in the road, embrace the characteristics of the site and create internal spaces and functions, emphasize the characteristics of each stairs, retain of uniqueness and highlight the characteristics of a vertical elements.

The Characteristics of Superposed Ozonizer using Three-Phase Voltage (3상전압을 이용한 중첩방전형 오존발생기의 특성)

  • Kim, Yeong-Hun;Chun, Byung-Joon;Song, Hyun-Jig;Youn, Young-Dae;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2259-2261
    • /
    • 1999
  • In this paper, an ozonizer, which can generate individual and superposed silent discharge, using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes(Central Electrode, Internal Electrode and External Electrode) and 2 gaps(gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the quantity of supplied gas($O_2$). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum values was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.

  • PDF

Temperature Dependence Characteristics of Double Cylindrical Type Ozonizer Using Spiral Type Internal Electrode (나선형 내부전극을 사용한 2중 원통형 오존발생기의 온도의존특성)

  • Chun, Byung-Joon;Lee, Sang-Keun;Rahman, Md. Fayzur;Lee, Dong-Heon;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2004-2006
    • /
    • 1999
  • In this paper, double Cylindrical type ozonizer has been designed and manufactured to improve ozone yield by cooling external electrode. The ozonizer equipped with three electrodes ( central, internal and external electrodes ). Discharge and ozone characteristics are described in this paper by varying the flow rate( Q ) of oxygen supplied gas, temperature of cooling gas and supplied voltage.

  • PDF

The Effect of 'Self Control Management Strategy' on the Reinforcement of Internal Locus of Control (내적 조절점 강화를 위한 자기 조절 관리 전략의 효과)

  • Park, Jin-Hee;Chang, Nam-Kee
    • Journal of The Korean Association For Science Education
    • /
    • v.17 no.4
    • /
    • pp.347-358
    • /
    • 1997
  • Locus of Control of Reinforcement (LOCR)' is considered as one of the most important factors on responsible environmental behaviors(REB). It is defined as 'an individual's perception of his or her ability to bring about change through his or her behavior'. This psychological construct is divided up into two directions: the external locus and internal locus. The internal locus is important as a predictor of REB. Recently, 'The Environmental Action Internal Control Index: EAICI' has been developed and it is a valid and reliable instrument to measure the relationship of two variables. The purposes of this study were to develop a strategy to reinforce the internal locus or to converse external locus to internal locus. and to verify the effects by EAICI. A new strategy, 'Self Control Management Strategy' was based on the characteristics of internal locus and the key idea of this was to self-control and to manage the courses by themselves. EAICI scores of the control group was 99.83. All of them were internal and the LOCR of females was more internal than that of the males. This strategy was applied when the instructions were carried out on seven environmental issues by the experimental group. According to the results. the seven points of the EAICI were increased significantly. Therefore this strategy is helpful in reinforcing the internal locus or to converse external locus to the internal locus.

  • PDF

The Characteristics of a Superposed Discharge Type Ozonizer Using Vacuum Discharge Tube (진공 방전관을 이용한 고농도 중첩방전형 오존발생기의 특성)

  • Song, Hyun-Jig;Lee, Chang-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.60-67
    • /
    • 2005
  • The superposed discharge type ozonizer of high ozone concentration using vacuum discharge tube has been designed and manufactured. It consists of three electrodes(central electrode, internal electrode, and external electrode) and one discharge gap(discharge gap between internal electrode and external electrode), is a superposed silent discharge type ozonizer for which the AC high voltages applied to the central electrode within discharge tube and the internal electrode has a $180{[^\circ]}$ phase difference and for which the external electrode is a ground. Ozone is generated by overlapping silent discharge between central electrode and external electrode, and silent discharge between internal electrode and external electrode. At the moment, discharge characteristics and ozone generation characteristics were investigated in accordance with vacuum of discharge tube, discharge power of ozonizer, and quantity of supplied oxygen gas. In consequence, high ozone concentration can be obtained 8840[ppm].

Boundary Characteristics of Transitional Space in Modern Korean Houses (한국 현대단독주택 전이공간의 경제적 특성에 관한 연구)

  • Kim, Hae-Young;Kwak, Kyoung-Suk;Kim, Hyung-Woo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.128-133
    • /
    • 2008
  • As societal development improves the quality of life and changes the structure of society, the needs of the residents have been varied. As a result, the spaces in Korean houses have also been varied. This phenomenon can be found in both external and internal spaces; a transitional space, which connects the outside space and the inside space, is formed as transition occurs at each phase of movement. As the importance of external and internal spaces is emphasized, and as internal spaces are extended to the exterior, various forms of transitional space are needed. In this study, the boundary types of internal/external spaces are analyzed through transitional spaces that are formed in relation with internal and external spaces. Based on the analysis, transitional spaces in modem Korean houses are classified into the addition type, the cutting type, and the connection type. The results of the study show that transitional spaces in detached houses tend to be placed closely to rooms and a public space, and in terms of material use, the externalization of internal spaces is occurring.

  • PDF

Cultural conditions and growth characteristics of indigo (Polygonum tinctorium) cells in an air-lift bioreactor (공기부양 생물반응기에서의 쪽 (Polygonum tinctorium) 세포배양의 생육조건 및 생육특성)

  • 신중한;이형주
    • KSBB Journal
    • /
    • v.8 no.3
    • /
    • pp.193-199
    • /
    • 1993
  • To find out the optimum conditions for indigo cell culture in air-lift bioreactor, effects of media composition including nutrients and precursors of the indigo colorants on the cell growth and characteristics of the cell growth under various cultural conditions were analyzed. Optimum cultural conditions were tested and the growth characteristics were analyzed in external and internal loop type air-lift bioreactors during 14-day culture. Better cell growth was obtained when the inoculum size was higher in the range of 0.5∼2.5% packed cell volume tested. In the sucrose concentration of 2 to 4%, the cell growth was better when the sucrose concentration was 4% (w/w) in both types of reactors. Sucrose was used up in the early stage of exponential phase of growth At the optimum concentration of a Precursor tryptophan at 1 U UW was 3.8 g/l in internal loop bioreactor, and 3.5 g/l in external one after 14 days of cultivation. Addition of indole showed negative effect on cell growth of suspension culture in air-lift biorector culture and cell mass of 2.5 g/l and 2.2 g/l were obtained in external and internal loop bioreactor, respectively. Selected inorganic nitrogen source potassium nitrate showed about 110% increase in cell growth than that of control. DCW was 16.34 g/l under optimum conditions during 14-day cultivation in internal loop bioreactor.

  • PDF

A study on V.M.D Rohan marketing strategy to sell eu basic characteristics about the enemy of the configuration space research (V.M.D 마케팅 전략을 기본으로 한 판매 공간의 구성적 특성에 관한 연구)

  • Jeong, Ji-Hye;Lee, Chang-No
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.190-195
    • /
    • 2008
  • Aggressive behavior and the purchase of systematic marketing strategy and the marketing strategy is applied consistently integrated image management needs. However, domestic fashion brand shops selling space, the reality is reckless use of the design elements and an age, and despite a high level of sales, but consumers are not getting the environment will he provided. Teenie Winnie the characteristics of burial space and tim ENC literature, materials, research through the local environment, architectural design, the human aspect, the store environment, external components, the investigation focuses on internal components. Maketing aspects, VP, IP, PP josago to systematically on a colorful aspects of the comparative analysis would be linked up. Winnie the characteristics of burial space and tim ENC literature, materials, research through the local environment, architectural design, the human aspect, the store environment, external components, the investigation focuses on internal components. Maketing aspects, VP, IP, PP josago to systematically on a colorful aspects of the comparative analysis would be linked up. First, the design aspects of the human environment, architecture, environmental stores, external components, internal components can be divided into The brand image and concept of same-store environment of mutual relations in other stores. The interior is an important element in order to draw attention to consumer needs.

  • PDF

The Influence Factors on the Adoption of Environmental Management Systems in Korean Manufacturing Firms (우리나라 제조기업의 환경경영시스템 도입에 대한 영향요인 연구)

  • Choe, Jong-Min
    • Korean Management Science Review
    • /
    • v.31 no.2
    • /
    • pp.15-32
    • /
    • 2014
  • This research empirically investigated the influence factors on the adoption of environmental management systems (EMS) in Korean manufacturing firms. In this study, the external factors (cause factors), the internal factors (facilitating factors) and the firm specific characteristics were integrally considered. In the factor analysis, the third item (regional society) of the external factors and the first item (environmental law) of government regulation were confounded with the items of the other factors. Thus, the confounded items were removed. In the second factor analysis, no items were replicated. The results of a multiple regression analysis showed that the influence factors such as government regulation, normative pressure, top management support, environmental strategy and employees' recognition, and ratio of large shareholders have a significant impact on the construction of EMS. However, the effects of the other firm specific characteristics were not statistically significant. We also examined whether both the number of environmental personnel and the allocation of environmental resources, which are directly related with the adoption of EMS, have a moderating impact on the relationships between other internal factors and the construction of EMS. With a subgroup analysis, the moderating roles of the number of environmental personnel were empirically confirmed. Through a multiple regression analysis, the direct effects of the external factors on the adoption or construction of the internal factors were demonstrated. The effects of government regulation, normative pressure and imitative pressure on the internal factors were significant and positive. Finally, in this study, the fact that the adoption of EMS can improve the environmental performance of a firm was also empirically found.

The Ozone Generation and Discharge Noise Characteristics of Superposed Discharge Noise Characteristics of Superposed Discharge Type Ozonizer Using Three-Phase Voltage (3상 전압을 사용한 중첩방전형 오존발생기의 오존생성 및 방전잡음특성)

  • 전병준;송현직;김영훈;최상태;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.59-67
    • /
    • 2000
  • In this paper, an ozonizer, which can supply individual and superposed silent discharge using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes(Central Electrode, Internal Electrode and External Electrode and External electrode) and 2 gaps (gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the flow rate of supplied gas (O2). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum value was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.

  • PDF