• Title/Summary/Keyword: Internal absorbed dose

Search Result 48, Processing Time 0.018 seconds

Simulation and assessment of 99mTc absorbed dose into internal organs from cardiac perfusion scan

  • Saghar Salari;Abdollah Khorshidi;Jamshid Soltani-Nabipour
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.248-253
    • /
    • 2023
  • Directly, it is not possible to measure the absorbed dose of radiopharmaceuticals in the organs of the human body. Therefore, simulation methods are utilized to estimate the dose in distinct organs. In this study, individual organs were separately considered as the source organ or target organ to calculate the mean absorption dose, which SAF and S factors were then calculated according to the target uptake via MIRD method. Here, 99mTc activity distribution within the target was analyzed using the definition and simulation of ideal organs by summing the fraction of cumulative activities of the heart as source organ. Thus, GATE code was utilized to simulate the Zubal humanoid phantom. To validate the outcomes in comparison to the similar results reported, the accumulation of activity in the main organs of the body was calculated at the moment of injection and cardiac rest condition after 60 min of injection. The results showed the highest dose absorbed into pancreas was about 21%, then gallbladder 18%, kidney 16%, spleen 15%, heart 8%, liver 8%, thyroid 7%, lungs 5% and brain 2%, respectively, after 1 h of injection. This distinct simulation model may also be used for different periods after injection and modifying the prescribed dose.

Evaluation of absorbed dose in monkey and mouse using 18F-FDG PET and CT density information

  • Kim, Wook;Lee, Yong Jin;Park, Yong Sung;Cho, Doo-Wan;Lee, Hong-Soo;Han, Su-Cheol;Kang, Joo Hyun;Woo, Sang-Keun
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.18-24
    • /
    • 2017
  • Patient-specific image-based internal dosimetry involves using the patient's individual anatomy and spatial distribution of radioactivity over time to obtain an absorbed dose calculation. Individual absorbed dose was calculated by accumulated activity multiply S-value of each organs. The aim of this study was to calculate the S-values using Monte Carlo simulation in monkey and mouse and evaluation of absorbed dose in each organ. Self-irradiation S-value of monkey heart self-irradiation was 3.15E-03 mGy-g/MBq-s, lung self-irradiation was 8.94E-04 mGy-g/MBq-s and liver self-irradiation S-value was 2.23E-03 mGy-g/MBq-s. Mouse heart self-irradiation S-value was 1.95E-01 mGy-g/MBq-s, lung was 9.59E-02 mGy-g/MBq-s, and liver was 1.40E-03 mGy-g/MBq-s. The results of this study show that the calculation protocol of image based individual absorbed dose of each organ using Monte Carlo simulation. Therefore, this study may be applied to calculate human specific absorbed dose.

Evaluation of Internal Dosimetry according to Various Radionuclides Conditions in Nuclear Medicine Myocardial Scan: Monte Carlo Simulation (심근 핵의학 검사에서 다양한 방사성핵종 조건에 따른 내부피폭선량 평가: 몬테카를로 시뮬레이션)

  • Min-Gwan Lee;Chanrok Park
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.213-218
    • /
    • 2024
  • The myocardial nuclear medicine examination is widely performed to diagnose myocardium disease using various radionuclides. Although image quality according to radionuclides has improved, the radiation exposure for target organ as well as peripheral organs should be considered. Here, the aim of this study was to evaluate absorbed dose (Gy) for peripheral organs in myocardial nuclear medicine scan from myocardium according to various scan environments based on Monte Carlo simulation. The simulation environment was modeled 5 cases, which were considered by radionuclides, number of injections, and radiodosage. In addition, the each radionuclide simulation such as distribution fraction was considered by recommended standard protocol, and the mesh computational female phantom, which is provided by International Commission on Radiological Protection (ICRP) 145, was used using the particle and heavy ion transport code system (PHITS) version 3.33. Based on the results, the closer to the myocardium, the higher the absorbed dose values. In addition, application for dual injection for radionuclides leaded to high absorbed dose compared with single injection for radionuclide. Consequently, there is difference for absorbed dose according to radionuclides, number of injections, and radiodosage. To detect the accurate diseased area, acquisition for improved image quality is crucial process by injecting radionuclides, however, we need to consider absorbed dose both target and peripheral inner organs from radionuclides in terms radiation protection for patient.

Assessment of Absorbed Dose of by Organ according to Thyroidal Uptake of Radioactive Iodine for Adult Korean Males (한국성인 남성을 대상으로 한 방사성옥소의 갑상선 섭취율에 따른 각 장기별 흡수선량 평가)

  • Kim, Junghoon;Lim, Changseon;Whang, Jooho
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.187-193
    • /
    • 2007
  • In an effort to assess the internal absorbed dose of radionuclides that is suitable to Koreans' physiological characteristics, we asked 28 male Koreans to take $^{131}|$ orally, determined the thyroidal uptake and daily urination ratio, and assessed the absorbed dose by organ. As a result, first, 24 hours after administering, the average thyroidal uptake and the daily urination ratio registered 19.70% and 71.12%, respectively. Second, the whole body effective dose according to the thyroidal uptake calculated herein and the existing ICRP-suggested thyroidal uptake of 30% offered 1.464E-08 Sv and 2.189E-08 Sv, respectively, showing a 1.5 times difference. To evaluate the quantity of the absorbed dose of radioactive iodine, we can better reduce the error in assessing the body exposure dose by conducting measurement according to human races rather than depending on the existing ICRP data.

  • PDF

Evaluation Absorbed Dose During the Breast Cancer Brachytherapy in Canine Phantom (반려견 팬텀에서 유방암 근접방사선치료 시 흡수선량 평가)

  • Kim, Jung-Hoon;Lee, Deuk-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.523-528
    • /
    • 2020
  • The application of breast cancer, which has the highest incidence in females among cancer that is the number one cause of death for dogs, was to be evaluated the absorbed dose during brachytherapy using simulation. MCNPX program was used for simulation, and a small size canine phantom was produced to measure absorbed dose. The results of the absorbed dose was the highest at 192Ir to 1.02E-12 Gy/# for tumors, and the same tendency was shown for internal and external absorbed dose. Therefore, the selection of appropriate sources for dog breast cancer should be considered in brachytherapy, taking into account dog breeds and exposures.

ABSORBED INTERNAL DOSE CONVERSION COEFFICIENTS FOR DOMESTIC REFERENCE ANIMALS AND PLANT

  • Keum, Dong-Kwon;Jun, In;Lim, Kwang-Muk;Choi, Yong-Ho
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.89-96
    • /
    • 2010
  • This paper describes the methodology of calculating the internal dose conversion coefficient in order to assess the radiological impact on non-human species. This paper also presents the internal dose conversion coefficients of 25 radionuclides ($^3H,\;^7Be,\;^{14}C,\;^{40}K,\;^{51}Cr,\;^{54}Mn,\;^{59}Fe,\;^{58}Co,\;^{60}Co,\;^{65}Zn,\;^{90}Sr,\;^{95}Nb,\;^{99}Tc,\;^{106}Ru,\;^{129}I,\;^{131}I,\;^{136}Cs,\;^{137}Cs,\;^{140}Ba,\;^{140}La,\;^{144}Ce,\;^{238}U,\;^{239}Pu,\;^{240}Pu$) for domestic seven reference animals (roe deer, rat, frog, snake, Chinese minnow, bee, and earthworm) and one reference plant (pine tree). The uniform isotropic model was applied in order to calculate the internal dose conversion coefficients. The calculated internal dose conversion coefficient (${\mu}Gyd^{-1}$ per $Bqkg^{-1}$) ranged from $10^{-6}$ to $10^{-2}$ according to the type of radionuclides and organisms studied. It turns out that the internal does conversion coefficient was higher for alpha radionuclides, such as $^{238}U,\;^{239}Pu$, and $^{240}Pu$, and for large organisms, such as roe deer and pine tree. The internal dose conversion coefficients of $^{239}U,\;^{240}Pu,\;^{238}U,\;^{14}C,\;^3H$, and $^{99}Tc$ were independent of the organism.

Comparative Studies on Absorbed Dose by Geant4-based Simulation Using DICOM File and Gafchromic EBT2 Film (DICOM 파일을 사용한 Geant4 시뮬레이션과 Gafchromic EBT2 필름에 의한 인체 내 흡수선량 비교 연구)

  • Mo, Eun-Hui;Lee, Sang-Ho;Ahn, Sung-Hwan;Kim, Chong-Yeal
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.48-53
    • /
    • 2013
  • Monte Carlo method has been known as the most accurate method for calculating absorbed dose in the human body, and an anthropomorphic phantom has been mainly used as a method of simulating internal organs for using such a calculation method. However, various efforts are made to extract data on several internal organs in the human body directly from CT DICOM files in recent Monte Carlo calculation using Geant4 code and to use by converting them into the geometry necessary for simulation. Such a function makes it possible to calculate the internal absorbed dose accurately while duplicating the actual human anatomical structure. Thus, this study calculated the absorbed dose in the human body by using Geant4 associating with DICOM files, and aimed to confirm the usefulness by compare the result with the measured dose using a Gafchromic EBT2 film. This study compared the dose calculated using simulation and the measured dose in beam central axis using the EBT2 film. The results showed that the range of difference was an average of 3.75% except for a build-up region, in which the dose rapidly changed from skin surface to the depth of maximum dose. In addition, this study made it easy to confirm the target absorbed dose by internal organ and organ through the output of the calculated value of dose by CT slice and the dose value of each voxel in each slice. Thus, the method that outputs dose value by slice and voxel through the use of CT DICOM, which is actual image data of human body, instead of the anthropomorphic phantom enables accurate dose calculations of various regions. Therefore, it is considered that it will be useful for dose calculation of radiotherapy planning system in the future. Moreover, it is applicable for currently-used several energy ranges in current use, so it is considered that it will be effectively used in order to check the radiation absorbed dose in the human body.

Surface Treatment of Eggshells with Low-Energy Electron Beam

  • Kataoka, Noriaki;Kawahara, Daigo;Sekiguchi, Masayuki
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.8-13
    • /
    • 2021
  • Background: Salmonella enteritidis (SE) was the main cause of the pandemic of foodborne salmonellosis. The surface of eggs' shells can be contaminated with this bacterium; however, washing them with sodium hypochlorite solution not only reduces their flavor but also heavily impacts the environment. An alternative to this is surface sterilization using low-energy electron beam. It is known that irradiation with 1 kGy resulted in a significant 3.9 log reduction (reduction factor of 10,000) in detectable SE on the shell. FAO/IAEA/WHO indicates irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard. On the other hand, the Food and Drug Administration has deemed a dose of up to 3 kGy is allowable for eggs. However, the maximum dose permitted to be absorbed by an edible part (i.e., internal dose) is 0.1 Gy in Japan and 0.5 Gy in European Union. Materials and Methods: The electron beam (EB) depth dose distribution in the eggshell was calculated by the Monte Carlo method. The internal dose was also estimated by Monte Carlo simulation and experimentation. Results and Discussion: The EB depth dose distribution for the eggshells indicated that acceleration voltages between 80 and 200 kV were optimal for eggshell sterilization. It was also found that acceleration voltages between 80 and 150 kV were suitable for reducing the internal dose to ≤ 0.10 Gy. Conclusion: The optimum irradiative conditions for sterilizing only eggshells with an EB were between 80 and 150 kV.

Absorbed Dose Measurement by the MIRD System in the $^{131}I$ Treated Thyroid Cancer Patients (갑상선 암 환자에서 $^{131}I$ 치료시 MIRD Schema에 의한 흡수선량의 평가)

  • Lim, Sang-Moo;Woo, Kwang-Sun;Chung, Wee-Sup;Hong, Sang-Woon;Kim, Jang-Hee;Kim, Ki-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.54-60
    • /
    • 1995
  • Medical Internal Radiation Dose(MIRD) schema was developed for calculating the absorbed dose from the administered radiopharmaceuticals. With the biological distribution data and the physical properties of the radionuclide we can estimate the absorbed dose by the MIRD schema. For the thyroid cancer patients received $^{131}I$ therapy, the absorbed dose to the bone marrow is the limiting factor to the administered dose, and the duration of admission is deter-mined by the retained activity in the whole body. To monitor the whole body radioactivity, we used Eberline Smart 200 system using ionization chamber as a detector. With the time activity curve of the whole body, total body residence time was obtained. From the ICRP publication 53, the residence times of the source organs, such as kidney, urinary bladder content and stomach, were used to calculate the absorbed doses of the target organs, such as stomach, red marrow, bladder wall and remaineder total body. In 8 thyroid cancer patients with 175 mci of $^{131}I$ administered orally, the mean absorbed dose in the bladder wall was 375.1, in the stomach 285.1, red marrow 25.4 and total body 22.4 rad respectively. For the monitoring of the large administered activity, this method seemed to be quite useful.

  • PDF

The Internal Dose Assessment of Ingested Radon using a PBPK Model for Repeated Oral Exposures (음용수를 통한 라돈의 반복섭취시 동적 약리학모델을 활용한 체내거동 평가)

  • 유동한;이창우
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.2
    • /
    • pp.43-50
    • /
    • 2001
  • A daily newspaper in Korea addressed an controversial issue recently that the concentration of radon measured from the groundwater in Taejon was found out a relatively high level. The cancer risk arising from ingestion of such radon should be derived from calculation of the dose absorbed by the tissues at risk. The study performed by the National Research Council in United States confirmed that the use of a PBPK model for the ingested radon could provide the useful information regarding the distribution of radon among the organs of the body. This study presents an approach for the internal dose assessment of ingested radon for this case. At first, the study develops a PBPK model for ingested radon. However, the important issue is how to simulate a more realistic situation using the model associated with repeated oral doses rather than a single oral dose. The simulations are performed for repeated oral exposures per 8-hour interval using the PBPK model for a male adult. The concentration and cumulative value of radon concentration are calculated and analyzed for lung tissue and adipose group, respectively. The results could be used for the realistic prediction of the internal dose of radon in the human body for repeated oral exposures.

  • PDF