• Title/Summary/Keyword: Internal Scan Chain

Search Result 9, Processing Time 0.01 seconds

Boundary Scan Test Methodology for Multiple Clock Domains (다중 시스템 클럭 도메인을 고려한 경계 주사 테스트 기법에 관한 연구)

  • Jung, Sung-Won;Kim, In-Soo;Min, Hyoung-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1850-1851
    • /
    • 2007
  • To the Boundary Scan, this architecture in Scan testing of design under the control of boundary scan is used in boundary scan design to support the internal scan chain. The internal scan chain has single scan-in port and single scan-out port that multiple scan chain cannot be used. Internal scan design has multiple scan chains, those chains must be stitched to form a scan chain as this paper. We propose an efficient Boundary Scan test structure for multiple clock testing in design.

  • PDF

Test Methodology for Multiple Clocks in Systems (시스템 내에 존재하는 다중 클럭을 제어하는 테스트 기법에 관한 연구)

  • Lee, Il-Jang;Kim, In-Soo;Min, Hyoung-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1840-1841
    • /
    • 2007
  • To the Boundary Scan, this architecture in Scan testing of design under the control of boundary scan is used in boundary scan design to support the internal scan chain. The internal scan chain has single scan-in port and single scan-out port that multiple scan chain cannot be used. Internal scan design has multiple scan chains, those chains must be stitched to form a scan chain as this paper. We propose an efficient Boundary Scan test structure for multiple clock testing in design.

  • PDF

Test Methodology for Multiple Clocks Single Capture Scan Design based on JTAG IEEE1149.1 Standard (IEEE 1149.1 표준에 근거한 다중 클럭을 이용한 단일 캡쳐 스캔 설계에 적용되는 경계 주사 테스트 기법에 관한 연구)

  • Kim, In-Soo;Min, Hyoung-Bok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.980-986
    • /
    • 2007
  • Boundary scan test structure(JTAG IEEE 1149.1 standard) that supports an internal scan chain is generally being used to test CUT(circuit under test). Since the internal scan chain can only have a single scan-in port and a single scan-out port; however, existing boundary test methods can not be used when multiple scan chains are present in CUT. Those chains must be stitched to form a single scan chain as shown in this paper. We propose an efficient boundary scan test structure that adds a circuit called Clock Group Register(CGR) for multiple clocks testing within the design of multiple scan chains. The proposed CGR has the function of grouping clocks. By adding CGR to a previously existing boundary scan design, the design is modified. This revised scan design overcomes the limitation of supporting a single scan-in port and out port, and it bolsters multiple scan-in ports and out ports. Through our experiments, the effectiveness of CGR is proved. With this, it is possible to test more complicated designs that have high density with a little effort. Furthermore, it will also benefit in designing those complicated circuits.

An Internal Pattern Run-Length Methodology for Slice Encoding

  • Lee, Lung-Jen;Tseng, Wang-Dauh;Lin, Rung-Bin
    • ETRI Journal
    • /
    • v.33 no.3
    • /
    • pp.374-381
    • /
    • 2011
  • A simple and effective compression method is proposed for multiple-scan testing. For a given test set, each test pattern is compressed from the view of slices. An encoding table exploiting seven types of frequently-occurring pattern is used. Compression is then achieved by mapping slice data into codewords. The decompression logic is small and easy to implement. It is also applicable to schemes adopting a single-scan chain. Experimental results show this method can achieve good compression effect.

Internal Pattern Matching Algorithm of Logic Built In Self Test Structure (Logic Built In Self Test 구조의 내부 특성 패턴 매칭 알고리즘)

  • Jeon, Yu-Sung;Kim, In-Soo;Min, Hyoung-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1959-1960
    • /
    • 2008
  • The Logic Built In Self Test (LBIST) technique is substantially applied in chip design in most many semiconductor company in despite of unavoidable overhead like an increase in dimension and time delay occurred as it used. Currently common LBIST software uses the MISR (Multiple Input Shift Register) However, it has many considerations like defining the X-value (Unknown Value), length and number of Scan Chain, Scan Chain and so on for analysis of result occurred in the process. So, to solve these problems, common LBIST software provides the solution method automated. Nevertheless, these problems haven't been solved automatically by Tri-state Bus in logic circuit yet. This paper studies the algorithm that it also suggest algorithm that reduce additional circuits and time delay as matching of pattern about 2-type circuits which are CUT(circuit Under Test) and additional circuits so that the designer can detect the wrong location in CUT: Circuit Under Test.

  • PDF

Usefulness of Mobile Computed Tomography in Patients with Coronavirus Disease 2019 Pneumonia: A Case Series

  • Ji Young Rho;Kwon-Ha Yoon;Sooyeon Jeong;Jae-Hoon Lee;Chul Park;Hye-Won Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.1018-1023
    • /
    • 2020
  • The coronavirus disease (COVID-19) outbreak has reached global pandemic status as announced by the World Health Organization, which currently recommends reverse transcription polymerase chain reaction (RT-PCR) as the standard diagnostic tool. However, although the RT-PCR test results may be found negative, there are cases that are found positive for COVID-19 pneumonia on computed tomography (CT) scan. CT is also useful in assessing the severity of COVID-19 pneumonia. When clinicians desire a CT scan of a patient with COVID-19 to monitor treatment response, a safe method for patient transport is necessary. To address the engagement of medical resources necessary to transport a patient with COVID-19, our institution has implemented the use of mobile CT. Therefore, we report two cases of COVID-19 pneumonia evaluated by using mobile cone-beam CT. Although mobile cone-beam CT had some limitations regarding its image quality such as scatter noise, motion and streak artifacts, and limited field of view compared with conventional multi-detector CT, both cases had acceptable image quality to establish the diagnosis of COVID-19 pneumonia. We report the usefulness of mobile cone-beam CT in patients with COVID-19 pneumonia.

Identification of Alternative Splicing and Fusion Transcripts in Non-Small Cell Lung Cancer by RNA Sequencing

  • Hong, Yoonki;Kim, Woo Jin;Bang, Chi Young;Lee, Jae Cheol;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.2
    • /
    • pp.85-90
    • /
    • 2016
  • Background: Lung cancer is the most common cause of cancer related death. Alterations in gene sequence, structure, and expression have an important role in the pathogenesis of lung cancer. Fusion genes and alternative splicing of cancer-related genes have the potential to be oncogenic. In the current study, we performed RNA-sequencing (RNA-seq) to investigate potential fusion genes and alternative splicing in non-small cell lung cancer. Methods: RNA was isolated from lung tissues obtained from 86 subjects with lung cancer. The RNA samples from lung cancer and normal tissues were processed with RNA-seq using the HiSeq 2000 system. Fusion genes were evaluated using Defuse and ChimeraScan. Candidate fusion transcripts were validated by Sanger sequencing. Alternative splicing was analyzed using multivariate analysis of transcript sequencing and validated using quantitative real time polymerase chain reaction. Results: RNA-seq data identified oncogenic fusion genes EML4-ALK and SLC34A2-ROS1 in three of 86 normal-cancer paired samples. Nine distinct fusion transcripts were selected using DeFuse and ChimeraScan; of which, four fusion transcripts were validated by Sanger sequencing. In 33 squamous cell carcinoma, 29 tumor specific skipped exon events and six mutually exclusive exon events were identified. ITGB4 and PYCR1 were top genes that showed significant tumor specific splice variants. Conclusion: In conclusion, RNA-seq data identified novel potential fusion transcripts and splice variants. Further evaluation of their functional significance in the pathogenesis of lung cancer is required.

Correlation between Telomere Length and Chronic Obstructive Pulmonary Disease-Related Phenotypes: Results from the Chronic Obstructive Pulmonary Disease in Dusty Areas (CODA) Cohort

  • Moon, Da Hye;Kim, Jeeyoung;Lim, Myoung Nam;Bak, So Hyen;Kim, Woo Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.3
    • /
    • pp.188-199
    • /
    • 2021
  • Background: Chronic obstructive pulmonary disease (COPD) is a common chronic respiratory disease with increased prevalence in the elderly. Telomeres are repetitive DNA sequences found at the end of the chromosome, which progressively shorten as cells divide. Telomere length is known to be a molecular marker of aging. This study aimed to assess the relationship between telomere length and the risk of COPD, lung function, respiratory symptoms, and emphysema index in Chronic Obstructive Pulmonary Disease in Dusty Areas (CODA) cohort. Methods: We extracted DNA from the peripheral blood samples of 446 participants, including 285 COPD patients and 161 control participants. We measured absolute telomere length using quantitative real-time polymerase chain reaction. All participants underwent spirometry and quantitative computed tomography scan. Questionnaires assessing respiratory symptoms and the COPD Assessment Test was filled by all the participants. Results: The mean age of participants at the baseline visit was 72.5±7.1 years. Males accounted for 72% (321 participants) of the all participants. The mean telomere length was lower in the COPD group compared to the non-COPD group (COPD, 16.81±13.90 kb; non-COPD, 21.97±14.43 kb). In COPD patients, 112 (75.7%) were distributed as tertile 1 (shortest), 91 (61.1%) as tertile 2 and 82 (55%) as tertile 3 (longest). We did not find significant associations between telomere length and lung function, exacerbation, airway wall thickness, and emphysema index after adjusting for sex, age, and smoking status. Conclusion: In this study, the relationship between various COPD phenotypes and telomere length was analyzed, but no significant statistical associations were shown.

An Effective Cache Test Algorithm and BIST Architecture (효율적인 캐쉬 테스트 알고리듬 및 BIST 구조)

  • Kim, Hong-Sik;Yoon, Do-Hyun;Kang, Sing-Ho
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.12
    • /
    • pp.47-58
    • /
    • 1999
  • As the performance of processors improves, cache memories are used to overcome the difference of speed between processors and main memories. Generally cache memories are embedded and small sizes, fault coverage is a more important factor than test time in testing point of view. A new test algorithm and a new BIST architecture are developed to detect various fault models with a relatively small overhead. The new concurrent BIST architecture uses the comparator of cache management blocks as response analyzers for tag memories. A modified scan-chain is used for pre-testing of comparators which can reduce test clock cycles. In addition several boundary scan instructions are provided to control the internal test circuitries. The results show that the new algorithm can detect SAFs, AFs, TFs linked with CFs, CFins, CFids, SCFs, CFdyns and DRFs models with O(12N), where N is the memory size and the new BIST architecture has lower overhead than traditional architecture by about 11%.

  • PDF