• Title/Summary/Keyword: Internal Quality Assurance System

Search Result 28, Processing Time 0.025 seconds

Nondestructive Internal Defects Evaluation for Pear Using NIR/VIS Transmittance Spectroscopy

  • Ryu, D.S.;Noh, S.H.;Hwnag, H.
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • Internal defects such as browning of the flesh and blackening and rot of the ovary of pear can be easily developed because of the inadequate environmental conditions during the storage and distribution of fruit. The quality assurance system for the agricultural product is to be settled in Korea. All defected agricultural products should be excluded prior to the distribution to enhance the commercial values. However, early stage on-line defect detection of agricultural product is very difficult and even more difficult in a case of the internal defects. The goal of this research is to develop a system that can detect and classify internal defects of agricultural produce on-line using VIS/NIR transmittance spectroscopy. And Shingo pear, which is one of the famous species of Korean pear, was used for the experiment. Soft independence modeling of class analogy (SIMCA) algorithm was employed to analyze the transmittance spectroscopic data qualitatively. On-line classification system was constructed and classification model was developed and validated. As a result, the correct classification rate (CCR) using the developed classification model was 96.1 %.

  • PDF

A case study on the implementation of the UK(Scotland) Quality Assurance system - based on the Stakeholder Theory - (영국(스코틀랜드) 질 관리체제 적용에 관한 사례연구 - 이해관계자 이론(Stakeholder Theory)을 중심으로 -)

  • Kim, Jeongeun
    • Korean Journal of Comparative Education
    • /
    • v.18 no.4
    • /
    • pp.27-55
    • /
    • 2008
  • Since quality assurance and enhancement (QAE) raises the fundamental issue of the survival of higher education institutions and national competitiveness, guides on quality assurance (QA) are popular both domestically and worldwide. Despite the focus in many countries on trying to establish and implement QA systems, no clear investigation has been conducted on what actually happens in the institutions. Therefore, the present study examines the quality control system of the UK at an institutional level by focusing on the case of Scotland QAE. As Scottish QAE especially emphasizes student engagement and quality culture, this study investigates the present QAE situation in the institution and current ideas for better future practices by analyzing the perceptions of internal stakeholders' from the University of Edinburgh, School of Education, based on the stakeholder theory and implications for other contexts. The stakeholder analysis results demonstrate the successful application of QAE with a high level of understanding and stakeholder interest. However, the current strategy is missing certain opportunities for staff and students. Therefore, further information disclosure, formative evaluation, better communication and administrational supports are required for improved practice.

A Development of The IT Audit-Based Application Framework for University IT Governance (대학정보화 거버넌스를 위한 감리기반 응용프레임워크 개발)

  • Choi, Jae Jun;Kim, Chi su
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.5
    • /
    • pp.179-186
    • /
    • 2019
  • Information system audit, which provides effective diagnosis and inspection of IT governance, is applied to all aspects from planning to development and operation. However, there is a difficulty in carrying out the audit because the system for the specialized university IT project is not developed. Therefore, it is necessary to set the internal system as the audit-based application framework in order to apply it to university IT governance. In this paper, we propose a audit-based application framework of university information system developed for university. The framework has a difference from the existing audit system. By using this framework, it is possible to present a standard for the university IT project and easily approach and use it in the field. And it can be used for direct audit through this framework in the level of the auditor as well as the HQ admin. The framework categorizes the audit into three major dimensions and suggests a method that can be applied to the university information system audit through the UAFP(University Audit Framework Process) and quality assurance.

Evaluation of Industrial Hygiene Laboratories by on-Site Investigation for Revised Quality Control System (개정된 정도관리제도를 적용한 작업환경측정기관의 실험실 현장 평가)

  • Shin, Jung-Ah;Yi, Gwang-Yong;Park, Seung-Hyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.243-249
    • /
    • 2013
  • Objectives: This study assessed the status of domestic industrial hygiene laboratories using data from on-site investigation for revision of quality control systems in 2012-2013. Methods: The target laboratories were 60 industrial hygiene laboratories chosen by random selection and nationwide distribution which had participated in on-site investigations for revision of quality control systems from March 2012 to August 2013. The investigation was performed on-site following standard quality control procedures. The score between each group was compared using Mann-Whitney and Kruskal-Wallis tests, and the correlation between analytical career, sex, academic major of analyst and score of analytical performance was expressed as Spearman's rank correlation coefficient. Results: The assessment revealed that the items to be improved, in sequence, were effort at staff training (score 65.5), ability to calculate data (score 73.4), establishment of internal quality control guidelines (score 75.7), laboratory facilities (score 77.1), degree of understanding and skill at gas chromatography (score 77.1). Analysis performance showed a positive correlation with career of analyst (r=0.56, p<0.01). Conclusions: The practice of on-site investigation for quality control systems showed the current status of industrial hygiene laboratories in the first trial. There were many laboratories which needed improvement and development of analytical systems. This assessment can provide information for the systematic operation and improvement of facilities at each laboratory. Further practice of this investigation will lead to a proficiency testing and accreditation system for autonomous quality control as is the practice in many countries, rather than mandatory practice by legal regulation.

A Study on the Establishment of Acceptable Range for Internal Quality Control of Radioimmunoassay (핵의학 검체검사 내부정도관리 허용범위 설정에 관한 고찰)

  • Young Ji, LEE;So Young, LEE;Sun Ho, LEE
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.43-47
    • /
    • 2022
  • Purpose Radioimmunoassay implement quality control by systematizing the internal quality control system for quality assurance of test results. This study aims to contribute to the quality assurance of radioimmunoassay results and to implement systematic quality control by measuring the average CV of internal quality control and external quality control by plenty of institutions for reference when setting the laboratory's own acceptable range. Materials and Methods We measured the average CV of internal quality control and the bounce rate of more than 10.0% for a total of 42 items from October 2020 to December 2021. According to the CV result, we classified and compared the upper group (5.0% or less), the middle group (5.0~10.0%) and the lower group (10.0% or more). The bounce rate of 10.0% or more was compared by classifying the item of five or more institutions into tumor markers, thyroid hormones and other hormones. The average CV was measured by the overall average and standard deviation of the external quality control results for 28 items from the first quarter to the fourth quarter of 2021. In addition, the average CV was measured by the overall average and standard deviation of the proficiency results between institutions for 13 items in the first half and the second half of 2021. The average CV of internal quality control and external quality control was compared by item so we compared and analyzed the items that implement well to quality control and the items that require attention to quality control. Results As a result of measuring the precision average of internal quality control for 42 items of six institutions, the top group (5.0% or less) are Ferritin, HGH, SHBG, and 25-OH-VitD, while the bottom group (≤10.0%) are cortisol, ATA, AMA, renin, and estradiol. When comparing more than 10.0% bounce rate of CV for tumor markers, CA-125 (6.7%), CA-19-9 (9.8%) implemented well, while SCC-Ag (24.3%), CA-15-3 (26.7%) were among the items that require attention to control. As a result of comparing the bounce rate of more than 10.0% of CV for thyroid hormones examination, free T4 (2.1%), T3 (9.3%) showed excellent performance and AMA (39.6%), ATA (51.6%) required attention to control. When comparing the bounce rate of 10.0% or more of CV for other hormones, IGF-1 (8.8%), FSH (9.1%), prolactin (9.2%) showed excellent performance, however estradiol (37.3%), testosterone (37.7%), cortisol (44.4%) required attention to control. As a result of measuring the average CV of the whole institutions participating at external quality control for 28 items, HGH and SCC-Ag were included in the top group (≤10.0%), however ATA, estradiol, TSI, and thyroglobulin included in bottom group (≥30.0%). Conclusion As a result of evaluating 42 items of six institutions, the average CV was 3.7~12.2% showing a 3.3 times difference between the upper group and the lower group. Cortisol, ATA, AMA, Renin and estradiol tests with high CV will require continuous improvement activities to improve precision. In addition, we measured and compared the overall average CV of the internal quality control, the external quality control and the proficiency between institutions participating of six institutions for 41 items excluding HBs-Ab. As a result, ATA, AMA, Renin and estradiol belong to the same subgroup so we require attention to control and consider setting a higher acceptable range. It is recommended to set and control the acceptable range standard of internal quality control CV in consideration of many things in the laboratory due to the different reagents and instruments, and the results vary depending on the test's proficiency and quality control materials. It is thought that the accuracy and reliability of radioimmunoassay results can be improved if systematic quality control is implemented based on the set acceptable range.

Detectibility of Internal Defects in Aluminum Die-casted Rotor Using Ultrasonic Technique (초음파를 이용한 알루미늄 다이캐스팅 회전자 내부 결함 검출능 평가에 관한 연구)

  • Lee, Jun-Hyeon;Choe, Sang-U
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.12
    • /
    • pp.185-191
    • /
    • 2001
  • The aluminum die-casting technique has been widely used to manufacture a rotor in motor industry because of its highly productivity, even though it sometime causes the various type of defects in the rotor, such as shrinkage, cavity, blow holes etc. which results in the decrease of the efficiency of system. Therefore the development of reliable technique to detect the flaws in the rotor is strongly needed not only to control quality assurance but to improve its efficiency. In this study, the wide variety of ultrasonic techniques have been applied to detect the flaws in the rotor and then to discuss the detectibility of the flaw and the applicability for NDE tool in the aluminum die-casting rotor.

  • PDF

Present Status of the Quality Assurance and Control (QA/QC) for Korean Macrozoobenthic Biological Data and Suggestions for its Improvement (해양저서동물의 정량적 자료에 대한 정도관리 현실과 개선안)

  • CHOI, JIN-WOO;KHIM, JONG SEONG;SONG, SUNG JOON;RYU, JONGSEONG;KWON, BONG-OH
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.3
    • /
    • pp.263-276
    • /
    • 2021
  • Marine benthic organisms have been used as the indicators for the environment assessment and recently considered as a very important component in the biodiversity and ecosystem restoration. In Korean waters, the quantitative data on marine benthos was used as one of major components for the marine pollution assessment for 50 years since 1970s. The species identification which is an important factor for the quantitative biological data was mainly performed by the marine benthic ecologists. This leads to the deterioration of the data quality on marine benthos from the misidentication of major taxonomic groups due to the lack of taxonomic expertise in Korea. This taxonomic problem has not been solved until now and remains in most data from national research projects on the marine ecosystems in Korean waters. Here we introduce the quality assurance and control (QA/QC) system for the marine biological data in UK, that is, NMBAQC (Northeast Atlantic Marine Biological Analytic and Quality Control) Scheme which has been performed by private companies to solve similar species identification problems in UK. This scheme asks for all marine laboratories which want to participate to any national monitoring programs in UK to keep their identification potency at high level by the internal quality assurance systems and provides a series of taxonomic workshops and literature to increase their capability. They also performs the external quality control for the marine laboratories by performing the Ring Test using standard specimens on various faunal groups. In the case of Korea, there are few taxonomic expertise in two existing national institutions and so they can't solve the taxonomic problems in marine benthic fauna data. We would like to provide a few necessary suggestions to solve the taxonomic problems in Korean marine biological data in short-terms and long-terms: (1) the identification of all dominant species in marine biological data should be confirmed by taxonomic expertise, (2) all the national research programs should include taxonomic experts, and (3) establishing a private company, like the Korea marine organism identification association (KMOIA), which can perform the QA/QC system on the marine organisms and support all Korean marine laboratories by providing taxonomic literature and species identification workshops to enhance their potency. The last suggestion needs more efforts and time for the establishment of that taxonomic company by gathering the detailed contents and related opinions from diverse stakeholders in Korea.

Building Transparency on the Total System Performance Assessment of Radioactive Repository through the Development of the Cyber R&D Platform; Application for Development of Scenario and Input of TSPA Data through QA Procedures (Cyber R&D Platform개발을 통한 방사성폐기물 처분종합성능평가(TSPA) 투명성 증진에 관한 연구; 시나리오 도출 과정과 TSPA 데이터 입력에서의 품질보증 적용 사례)

  • Seo, Eun-Jin;Hwang, Yong-Soo;Kang, Chul-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.65-75
    • /
    • 2006
  • Transparency on the Total System Performance Assessment (TSPA) is the key issue to enhance the public acceptance for a radioactive repository. To approve it, all performances on TSPA through Quality Assurance is necessary. The integrated Cyber R&D Platform is developed by KAERI using the T2R3 principles applicable for five major steps : planning, research work, documentation, and internal & external audits in R&D's. The proposed system is implemented in the web-based system so that all participants in TSPA are able to access the system. It is composed of three sub-systems; FEAS (FEp to Assessment through Scenario development) showing systematic approach from the FEPs to Assessment methods flow chart, PAID (Performance Assessment Input Databases) being designed to easily search and review field data for TSPA and QA system containing the administrative system for QA on five key steps in R&D's in addition to approval and disapproval processes, corrective actions, and permanent record keeping. All information being recorded in QA system through T2R3 principles is integrated into Cyber R&D Platform so that every data in the system can be checked whenever necessary. Throughout the next phase R&D, Cyber R&D Platform will be connected with the assessment tool for TSPA so that it will be expected to search the whole information in one unified system.

  • PDF

A Comparative study among 2nd cycle of Evaluation and Accreditation system on Korean Medicine Education, Global Standards of WFME for Basic Medical Education and WHO guidelines for quality assurance of Traditional Medicine Education in the Western Pacific Region (한의학교육평가원 2주기, 세계의학교육연합회(WFME)의 의학기본교육, WHO 서태평양 지역지부(WHO/WPRO) 인증 기준 간의 비교 연구)

  • Sun, Seung Ho
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.41-57
    • /
    • 2019
  • Objective : The purpose of our study is to compare and analyze the standards for the 2nd cycle of Evaluation and Accreditation system on institute of Korean Medicine Education & Evaluation (2nd IKMEE standards) and WHO guidelines for quality assurance of Traditional Medicine Education in the Western Pacific Region (WHO/WPRO guidelines) around the global standards of World Federation for Medical Education for basic medical education (WFME standard) to identify the shortcomings and improvements of 2nd IKMEE standards. Method : Each article of 2015 revised WFME standard was translated and summarized with focus on its core content. The next step was to review and analyze the corresponding contents of 2nd IKMEE standards in 2016 and the WHO/WPRO guidelines in 2005 for each item, focusing on the WFME standards. Results : All items in the fields of 3. assessment of students and 7. program evaluation in the WFME domain were absent from the 2nd IKMEE standards, and almost none of the WHO/WPRO guidelines. Most items in 1. the mission and outcomes domain, except for some items in the 1.1 mission field, the items of 2.6~2.8 fields in 2. education program domain, the items of 4. student domain except for the items of 4.3 student counseling and support field, and almost all items about quality development in WFME standards did not have a corresponding item in both the 2nd IKMEE standards and the WHO/WPRO standards. Conclusion : 1. The WFME standards are applicable to the criteria development of IKMEE standards. Several items of the WFME standards may need to be modified to apply the educational characteristics of Korean medicine, but consensus or further study is required. 2. Both the 2nd IKMEE standards and the WHO/WPRO standards are very insufficient to meet the WFME standards. In particular, 3. assessment of students and 7. program evaluation in the WFME domain were not in the 2nd IKMEE standards. This standard needs to be supplemented.

Web-based QA Workflow System for Radioactive Waste Disposal (방사성 폐기물 처분연구의 QA절차에 따른 웹기반 문서처리 워크플로우 시스템 개발)

  • 김태운;고창성;서대희;이광욱;강철형;황용수;이연명
    • The Journal of Information Systems
    • /
    • v.12 no.1
    • /
    • pp.159-175
    • /
    • 2003
  • During the early stage of radioactive disposal programs, important issues related with quality assurance of data sets, methodologies, R&D procedures are recognized as important ones. This paper focused on the development of web-based workflow standards for the QA procedures of the radioactive waste disposal programs. The flow of process was analyzed based on workflow concepts proposed by the Workflow Management Coalition (WfMC). QA system is based on the principles of T2R3. T2R3 Workflow was used to standardize and restructure the business and/or work process in the industry or organization. The WfMC has identified five functional interfaces to a workflow service as part of its standardization program. They are composed of process definition interface, worklist handler, application program interface, interface between workflows, and system management. The task flow and QA program were defined based on the workflow ideas. QA procedures for the R&D results of radiation disoposal were analyzed following the reference model of workflow. In addition, six program run list were created and implemented. The creation, revision, and approval of the test data were designed to be inplemented on the web environment. Through this system, R&D procedures such as planning, research, documentation, internal review and future independent peer review processes could be well organized and stored more systematically on the database and knowledge base. This will encourage the usage and data sharing between interested parties through it's clear and transparent workflow standards.

  • PDF