• Title/Summary/Keyword: Internal Model

Search Result 4,537, Processing Time 0.037 seconds

Robust Internal Model Control of Three-Phase Active Power Filter for Stable Operation in Electric Power Equipment (전력설비의 안정한 운용을 위한 3상 능동전력필터의 강인한 내부모델제어)

  • Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1487-1493
    • /
    • 2013
  • A new simple control method for active power filter, which can realize the complete compensation of harmonics is proposed. In the proposed scheme, a model-based digital current control strategy is presented. The proposed control system is designed and implemented in a form referred to as internal model control structure. This method provides a convenient way for parameterizing the controller in term of the nominal system model, including time-delays. As a result, the resulting controller parameters are directly set based on the power circuit parameters, which make tuning of the controllers straightforward task. In the proposed control algorithm, overshoots and oscillations due to the computation time delay is prevented by explicit incorporating of the delay in the controller transfer function. In addition, a new compensating current reference generator employing resonance model implemented by a DSP(Digital Signal Processor) is introduced. Resonance model has an infinite gain at resonant frequency, and it exhibits a band-pass filter. Consequently, the difference between the instantaneous load current and the output of this model is the current reference signal for the harmonic compensation.

Lipid-lowering and Antioxidant Effects of Curcuma Radix in Poloxamer 407-induced Hyperlipidemia Model Rat Models

  • Park, So-Ae;Jo, Hyun-Kyung;Yoo, Ho-Ryong;Kim, Yoon-Sik;Seol, In-Chon;An, Joung-Jo
    • The Journal of Internal Korean Medicine
    • /
    • v.32 no.2
    • /
    • pp.243-258
    • /
    • 2011
  • Objectives : This study investigated the hypolipidemic and antioxidant effects of Curcuma radix using a rat model induced by poloxamer 407 injection. Methods : Serum lipid parameters and oxidative stress-associated biomarkers were determined. Additionally, hepatic cholesterol and triglyceride as well as lipid metabolism-associated gene expressions were observed in hepatic tissue. Results : 1. Curcuma radix ameliorated elevation of serum cholesterol, triglyceride, LDL-cholesterol, MDA, hepatic cholesterol level, and reduction of serum TAC, SOD, GSH, GSH-reductase level. 2. Curcuma radix augmented up-regulated ACAT gene expression. 3. Curcuma radix almost completely ameliorated down-regulated CYP-7A1 but up-regulated HMG-CoA gene expression. Conclusions : The hypolipidemic and antioxidant properties of Curcuma radix were evidenced. This study provides a scientific basis for the clinical application of Curcuma radix and development of hypolipidemics using this herb in the future.

ABSORBED INTERNAL DOSE CONVERSION COEFFICIENTS FOR DOMESTIC REFERENCE ANIMALS AND PLANT

  • Keum, Dong-Kwon;Jun, In;Lim, Kwang-Muk;Choi, Yong-Ho
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.89-96
    • /
    • 2010
  • This paper describes the methodology of calculating the internal dose conversion coefficient in order to assess the radiological impact on non-human species. This paper also presents the internal dose conversion coefficients of 25 radionuclides ($^3H,\;^7Be,\;^{14}C,\;^{40}K,\;^{51}Cr,\;^{54}Mn,\;^{59}Fe,\;^{58}Co,\;^{60}Co,\;^{65}Zn,\;^{90}Sr,\;^{95}Nb,\;^{99}Tc,\;^{106}Ru,\;^{129}I,\;^{131}I,\;^{136}Cs,\;^{137}Cs,\;^{140}Ba,\;^{140}La,\;^{144}Ce,\;^{238}U,\;^{239}Pu,\;^{240}Pu$) for domestic seven reference animals (roe deer, rat, frog, snake, Chinese minnow, bee, and earthworm) and one reference plant (pine tree). The uniform isotropic model was applied in order to calculate the internal dose conversion coefficients. The calculated internal dose conversion coefficient (${\mu}Gyd^{-1}$ per $Bqkg^{-1}$) ranged from $10^{-6}$ to $10^{-2}$ according to the type of radionuclides and organisms studied. It turns out that the internal does conversion coefficient was higher for alpha radionuclides, such as $^{238}U,\;^{239}Pu$, and $^{240}Pu$, and for large organisms, such as roe deer and pine tree. The internal dose conversion coefficients of $^{239}U,\;^{240}Pu,\;^{238}U,\;^{14}C,\;^3H$, and $^{99}Tc$ were independent of the organism.

Development of $5^{th}$ percentile female finite Element Model for Crashworthiness Simulation - Part I Articulated Rigid Body Model (충돌 안전도 해석을 위한 $5^{th}$ percentile 성인 여성 유한요소 모델 개발 - Part I 다물체 동력학 모델 개발)

  • 나상진;최형연;이진희
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.277-282
    • /
    • 2004
  • In order to investigate the small female occupant behavior and accompanying injury mechanisms in vehicular trash event, a finite element model of $5^{th}$ percentile female has been developed. The model consists of articulated rigid body, which represents the morphology of small female body, and internal components with anatomical details. Articulated rigid body model serves as a basic platform for joining the detail internal skeletons and organs, while itself can be used for representing the overall kinematics of small female occupant. The modeling details such as anthropometry and finite element structure as well as validation results for the articulated rigid body model are introduced in this paper. The second part of the modeling, i.e. the internal components with anatomical details of small female are presented in subsequent part II of the paper.

Application of the new ICRP iodine biokinetic model for internal dosimetry in case of thyroid blocking

  • Kwon, Tae-Eun;Chung, Yoonsun;Ha, Wi-Ho;Jin, Young Woo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1826-1833
    • /
    • 2020
  • Administration of stable iodine has been considered a best measure to protect the thyroid from internal irradiation by radioiodine intake, and its efficacy on thyroid protection has been quantitatively evaluated in several simulation studies on the basis of simple iodine biokinetic models (i.e., three-compartment model). However, the new iodine biokinetic model adopted by the International Commission on Radiological Protection interprets and expresses the thyroid blocking phenomenon differently. Therefore, in this study, the new model was analyzed in terms of thyroid blocking and implemented to reassess the protective effects and to produce dosimetric data. The biokinetic model calculation was performed using computation modules developed by authors, and the results were compared with those of experimental data and prior simulation studies. The new model predicted protective effects that were generally consistent with those of experimental data, except for those in the range of stable iodine administration -72 h before radioiodine exposure. Additionally, the dosimetric data calculated in this study demonstrates a critical limitation of the three-compartment model in predicting bioassay functions, and indicated that dose assessment 1 d after exposure would result in a similar dose estimate irrespective of the administration time of stable iodine.

Scaling methods for wind tunnel modelling of building internal pressures induced through openings

  • Sharma, Rajnish N.;Mason, Simon;Driver, Philip
    • Wind and Structures
    • /
    • v.13 no.4
    • /
    • pp.363-374
    • /
    • 2010
  • Appropriate scaling methods for wind tunnel modelling of building internal pressures induced through a dominant opening were investigated. In particular, model cavity volume distortion and geometric scaling of the opening details were studied. It was found that while model volume distortion may be used to scale down buildings for wind tunnel studies on internal pressure, the implementation of the added volume must be done with care so as not to create two cavity resonance systems. Incorrect scaling of opening details was also found to generate incorrect internal pressure characteristics. Furthermore, the effective air slug or jet was found to be longer when the opening was near a floor or sidewall as evidenced by somewhat lower Helmholtz frequencies. It is also shown that tangential flow excitation of Helmholtz resonance for off-centre openings in normal flow is also possible.

A Study about Internal Control Deficient Company Forecasting and Characteristics - Based on listed and unlisted companies - (내부통제 취약기업 예측과 특성에 관한 연구 - 상장기업군과 비상장기업군 중심으로 -)

  • Yoo, Kil-Hyun;Kim, Dae-Lyong
    • Journal of Digital Convergence
    • /
    • v.15 no.2
    • /
    • pp.121-133
    • /
    • 2017
  • The propose of study is to examine the characteristics of companies with high possibility to form an internal control weakness using forecasting model. This study use the actual listed/unlisted companies' data from K_financial institution. The first conclusion is that discriminant model is more valid than logit model to predict internal control weak companies. A discriminant model for predicting the vulnerability of internal control has high classification accuracy and has low the Type II error that is incorrectly classifying vulnerable companies to normal companies. The second conclusion is that the characteristic of weak internal control companies have a low credit rating, low asset soundness assessment, high delinquency rates, lower operating cash flow, high debt ratios, and minus operating profit to the net sales ratio. As not only a case of listed companies but unlisted companies which did not occur in previous studies are extended in this study, research results including the forecasting model can be used as a predictive tool of financial institutions predicting companies with high potential internal control weakness to prevent asset losses.

Analytic Breakdown Voltage Model of LDMOS with Internal Field Ring (내부 전계 링을 갖는 LDMOS의 해석적 항복전압 모델)

  • 오동주;염기수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.377-380
    • /
    • 2003
  • An Analytic breakdown voltage model of LDMOS with internal field ring is proposed. The model is a simple analytic formula which has variables such as the dimension of drift retion, the position and doping concentration of the internal field ring, the thickness and permittivity of oxide. By comparing the results from two dimensional TCAD simulation, the proposed model explains the breakdown phenomena fairly well.

  • PDF

An Experimental Study on the Aerodynamic Drag of Model Cars with Cooling Air Passage (냉각유동이 자동차항력에 미치는 영향에 관한 실험적 연구)

  • 안이기;정형호;김광호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.405-413
    • /
    • 1994
  • This paper presents the experimental results of aerodynamic drags of model cars. The effects of cooling air on total drag were introduced by using momentum theorem. Vehicle-liked Ahmed body and 1/5 model car were used to evaluate the increments of drags due to the internal flow. The results were compared with momentum theorem and other's experiments and showed good agreements. In the case of Ahmed body, drags were increased by 22% due to the internal flow and decreased linealy by reducing internal air flow rates and inlet areas. The experiments on 1/5 model car with ill-defined air flow passage showed 10% increment of drag. The results of present study showed that cooling drag could be predicted by momentum theorem within small errors.

Fluid-Structure Interaction Analysis of Blood Vessel Considering Internal Diameter Variation (내부직경 변화를 고려한 혈관의 유체-구조 상호작용 해석)

  • Octavianty, Ressa;Kim, Dong-Hyun;Kim, Su-Hyun;S. Nababan, Boyke;Byun, Jun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.959-963
    • /
    • 2006
  • A three-dimensional elastic blood vessel model with internal diameter variation is considered to investigate internal flow characteristics and effects of structural deformation. Also, computational analyses for both the rigid model and the fully-coupled FSI model have been conducted in order to compare the shear stress, pressure distribution, and flow velocity in detail. A 70% narrowing area of asymmetric blood vessel model was especially investigated to show the versatility of fluid-structure interaction phenomenon. The results reveal that effect of fluid-structure interaction is very important to accurately investigate the flow characteristics of the blood vessel.

  • PDF