Delayed Foreign Body Reaction around the Absorbable Implants in Facial Bone Fracture: A Case Report (안면부 골절에 사용된 흡수성 보형물의 지연성 이물반응: 증례보고)

  • Suh, Yong-Hoon;Kim, Young-Joon
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.875-878
    • /
    • 2011
  • Purpose: Absorbable implants are frequently used to fix facial bone fractures, because they are radiolucent and compatible with magnetic resonance imaging (MRI). Despite their increasing usage, however, there have been few reports about their long-term side-effects. In this paper, a case in which absorbable implants led to a foreign body reaction 17 months after their insertion is presented. Methods: A previously healthy 19-year-old male fell from a flight of stairs and visited the authors' hospital with right periorbital pain. Zygomaticomaxillary fracture involving right orbital floor was detected via a facial bone computed tomography (CT). Internal fixation with absorbable implants was followed by open reduction. 17 months after the surgery, the patient complained of localized periorbital swelling. Removal of the granulomatous lesion including the absorbable implants along with their biopsy and culture was performed. Results: The granulomatous lesion around the implants was firm and extended into the maxillary sinus. The histologic finding showed a microabscess with a foreign body reaction. Methicillin-sensitive Staphylococcus aureus growth was confirmed in the culture. No definite abnormal symptoms ensued after the complete removal. Conclusion: A microabscess-forming granulomatous lesion around the absorbable implant can cause delayed symptomatic foreign body reaction despite its rare occurrence. Complete removal of the lesion including implants is expected to have a successful outcome if it is encountered.

Deep circumflex iliac artery free flap in the mandibular reconstruction (DCIA를 이용한 하악골 재건술)

  • Won, Ji-Hoon;Kim, Bong-Chul;Kim, Hyung-Jun
    • The Journal of the Korean dental association
    • /
    • v.49 no.9
    • /
    • pp.520-526
    • /
    • 2011
  • Vascularized iliac crest flap include bone tissue of good quality and quantity for mandible segmental defect. Even if fibular flap can contain longer bone tissue, iliac crest has esthetic shape for mandible body reconstruction and large height for implant. Conventional vascularized iliac crest osteomyocutaneous flap is too bulky for reconstruction of intraoral soft tissue defect. But modified flap can reduce soft tissue volume, so is good for functional reconstruction of oral mucosa. It takes only one month for completely replace oral mucosa. The final mucosal texture is much better than other skin paddle flap, especially for implant prosthesis. Donor site morbidity of this method looks same level or less with other modalities functionally and socially. In case of oral mucosa-mandible combined defect, vascularized iliac crest with internal oblique muscle flap shows good outcomes for hard and soft tissue.

Signal Processing and Implementation of Transmitter for Cochlear Implant (인공 와우를 위한 신호 처리 및 전달부의 구현)

  • Chae, D.;Choi, D.;Byun, J.;Baeck, S.;Kong, H.;Park, S.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.284-286
    • /
    • 1993
  • Software and hardware for cochlear implant system have been developed to create a speech signal processing system which, in real-time, extracts model parameter including formants, pitch, amplitude information. The system is based on the Texas Instruments TMS320 family. In hardware, computer interface has been desisted and implemented that allows presentation of biphasic pulse stimuli to patients with the hearing handicapped. The host computer sends a stream of bytes to the parallel port. Upon receipt of the data the interface generates the appropriate burst sequence that is delivered to the patient's external transmitter coil. The coded information is interpreted by the Nucleus-22 internal receiver that delivers the pulse to the specified electrodes at the specified amplitude and pulse width.

  • PDF

Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System

  • Youngho Cho;Jae-uk Shin;Sangwoo Kim
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.47-53
    • /
    • 2023
  • Purpose: The purpose of this study is to compare the radiological results of fixation using the femoral neck system (FNS) and cannulated screw (CS) for treatment of femoral neck fractures. Materials and Methods: A retrospective study of patients with femoral neck fractures who underwent internal fixation and had follow-up of more than six months from 2010 to 2020 was conducted. A total of 87 patients were enrolled in the study. The FNS group included 20 patients and the CS group included 67 patients. Classification of fractures was performed according to Garden and Pauwels classification. Operation time, intraoperative blood loss, sliding distance of the implant, lateral soft tissue irritation caused by implants, and complications were evaluated. Results: The mean operation time was 40.30 minutes in the FNS group and 46.84 minutes in the CS group. The mean intraoperative bleeding volume was 51.25 mL in the FNS group and 72.16 mL in the CS group. Bone union was achieved in 18 patients in the FNS group (90.0%) and in 61 patients in the CS group (91.0%). The mean sliding distance of the implant was 4.06 mm in the FNS group and 3.92 mm in the CS group. No patients in the FNS group and 12 patients in the CS group complained of soft tissue irritation. Conclusion: A shorter operative time, less intraoperative bleeding, and less irritation of soft tissue were observed in the FNS group. FNS could be an alternative to CS for fixation of femoral neck fractures.

Implant Removal after Percutaneous Short Segment Fixation for Thoracolumbar Burst Fracture : Does It Preserve Motion?

  • Kim, Hyeun Sung;Kim, Seok Won;Ju, Chang Il;Wang, Hui Sun;Lee, Sung Myung;Kim, Dong Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.73-77
    • /
    • 2014
  • Objective : The purpose of this study was to evaluate the efficacy of implant removal of percutaneous short segment fixation after vertebral fracture consolidation in terms of motion preservation. Methods : Between May 2007 and January 2011, 44 patients underwent percutaneous short segment screw fixation due to a thoracolumbar burst fracture. Sixteen of these patients, who underwent implant removal 12 months after screw fixation, were enrolled in this study. Motor power was intact in all patients, despite significant vertebral height loss and canal compromise. The patients were divided into two groups by degree of osteoporosis : Group A (n=8), the non-osteoporotic group, and Group B (n=8), the osteoporotic group. Imaging and clinical findings including vertebral height loss, kyphotic angle, range of motion (ROM), and complications were analyzed. Results : Significant pain relief was achieved in both groups at final follow-up versus preoperative values. In terms of vertebral height loss, both groups showed significant improvement at 12 months after screw fixation and restored vertebral height was maintained to final follow-up in spite of some correction loss. ROM (measured using Cobb's method) in flexion and extension in Group A was $10.5^{\circ}$ ($19.5/9.0^{\circ}$) at last follow-up, and in Group B was $10.2^{\circ}$ ($18.8/8.6^{\circ}$) at last follow-up. Both groups showed marked improvement in ROM as compared with the screw fixation state, which was considered motionless. Conclusion : Removal of percutaneous implants after vertebral fracture consolidation can be an effective treatment to preserve motion regardless of osteoporosis for thoracolumbar burst fractures.

Implementation of Wireless Charger with the Function of Auto-Shutdown for fully Implantable Middle Ear Hearing Devices (완전 이식형 인공중이를 위한 자동 충전종료형 무선 충전장치의 구현)

  • Lee, Jang-Woo;Lim, Hyung-Gyu;Jung, Eui-Sung;Han, Ji-Hun;Lee, Seung-Hyun;Park, Il-Yong;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.539-548
    • /
    • 2007
  • In the paper, a wireless charger with the function of auto-shutdown for fully implantale middle ear hearing devices (F-IMEHD) has been designed. The wireless charger can communicate with an implant module to be turned off automatically shutdown after an internal rechargeable battery has been fully-charged by electromagnetic coupling using two coils. For the communication with an implant module, the wireless charger uses the load shift keying (LSK) method. But, the variation of the mutual inductance due to the different distance between two coils can cause the communication error in receiving the fully-charged signal from an implant module. To solve the problem, the implemented wireless charger has a variable reference generator for LSK communication. The wireless charger generates proper level of the reference voltage for a comparator using an ADC (analog-to-digital converter) and a DAC (digital-to-analog converter). Through the result of experiment, it has been confirmed that the presented wireless charger can detect signals from implantable module. And wireless charger can stop generating electromagnetic flux after an implanted battery has been fully charged in spite of variable coil distance according to different skin thickness.

Clinical accuracy of impression technique using digital superimposition of customized abutment with subgingival margin: A case report (치은연하 변연을 가지는 맞춤형 지대주에서 디지털 중첩기술을 이용한 인상채득술의 임상 적용 증례)

  • Kim, Jin-Wan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeonjong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.169-175
    • /
    • 2020
  • Traditionally, gingival retraction has been performed to obtain customized abutment impressions with subgingival margins of the implant supported prosthesis. However, gingival retraction may have side effects such as gingival recession and bleed, leading to an inaccurate impression. In order to prevent these problems, in this case, the new technique has been introduced; a customized abutment which is designed for superimposition is used. Before the connection of the abutment to the implant fixture, pre-scanned shape data are stored, and then the optical impression without gingival retraction is obtained after connecting to the fixture. The suprastructure is fabricated by superimposing the two data. This technique showed the clinical efficacy of fabricating the implant supported prosthesis with subgingival margin, which satisfied the aesthetics, convenience, and clinically acceptable marginal and internal fit.

The non-linear FEM analysis of different connection lengths of internal connection abutment (내측 연결형 임플란트 지대주의 체결부 길이 변화에 따른 비선형 유한요소법적 응력분석)

  • Lee, Yong-Sang;Kang, Kyoung-Tak;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.110-119
    • /
    • 2016
  • Purpose: This study is aimed to assess changes of stress distribution dependent on different connection lengths and placement of the fixture top relative to the ridge crest. Materials and methods: The internal-conical connection implant which has a hexagonal anti-rotation index was used for FEM analysis on stress distribution in accordance with connection length of fixture-abutment. Different connection lengths of 2.5 mm, 3.5 mm, and 4.5 mm were designed respectively with the top of the fixture flush with residual ridge crest level, or 2 mm above. Therefore, a total of 6 models were made for the FEM analysis. The load was 170 N and 30-degree tilted. Results: In all cases, the maximum von Mises stress was located adjacent to the top portion of the fixture and ridge crest in the bone. The longer the connection length was, the lower the maximum von Mises stress was in the fixture, abutment, screw and bone. The reduction rate of the maximum von Mises stress depending on increased connection length was greater in the case of the fixture top at 2 mm above the ridge crest versus flush with the ridge crest. Conclusion: It was found that the longer the connection length, the lower the maximum von Mises stress appears. Furthermore, it will help prevent mechanical or biological complications of implants.

Assessment of Internal Fitness on Resin Crown Fabricated by Digital Light Processing 3D Printer

  • Kang, Wol;Kim, Min-Su;Kim, Won-Gi
    • Journal of dental hygiene science
    • /
    • v.19 no.4
    • /
    • pp.238-244
    • /
    • 2019
  • Background: Recently, three-dimensional (3D) printing has been hailed as a disruptive technology in dentistry. Among 3D printers, a digital light processing (DLP) 3D printer has certain advantages, such as high precision and relatively low cost. Therefore, the latest trend in resin crown manufacturing is the use of DLP 3D printers. However, studies on the internal fitness of such resin crowns are insufficient. The recently introduced 3D evaluation method makes it possible to visually evaluate the error of the desired area. The purpose of this study is to evaluate the internal fitness of resin crowns fabricated a by DLP 3D printer using the 3D evaluation method. Methods: The working model was chosen as the maxillary molar implant model. A total of 20 resin crowns were manufactured by dividing these into two groups. One group was manufactured by subtractive manufacturing system (PMMA), while the other group was manufactured by additive manufacturing system, which uses a DLP 3D printer. Resin crowns data were measured using a 3D evaluation program. Internal fitness was calculated by root mean square (RMS). The RMS was calculated using the Geomagic Verify software, and the mean and standard deviation (SD) were measured. For statistical analysis, IBM SPSS Statistics for Windows ver. 22.0 (IBM Corp., USA) was used. Then, independent t-test was performed between the two groups. Results: The mean±SD of the RMS were 41.51±1.51 and 43.09±2.32 for PMMA and DLP, respectively. There was no statistically significant difference between PMMA and DLP. Conclusion: Evaluation of internal fitness of the resin crown made using a DLP 3D printer and subtractive manufacturing system showed no statistically significant differences, and clinically acceptable results were obtained.

Effect of internal gap on retentivity in implant fixed prosthesis with lingual slot (설측 슬롯을 부여한 임플란트 고정성 보철물에서 내면 간격이 유지력에 미치는 영향)

  • Kim, Tae-Kyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.206-211
    • /
    • 2018
  • Purpose: Recently, a method of forming a slot in the prosthesis lingual has been introduced to solve the occlusal and aesthetic disadvantages of screw-retained prosthesis in the manufacture of implant-fixed prosthesis and to ensure retrievability in cement retained prostheses. The purpose of this study is to investigate the effect of the internal gap on the removal of the prosthesis in the preparation of cement-retained implant prostheses with lingual slots. Materials and methods: Titanium abutment and internal gap of the zirconia prosthesis to be attached to the upper part were set to 30, 35, and $50{\mu}m$, respectively. Three for each type total 15 were produced for each type. The zirconia prosthesis formed a retrievable cement-type slot with a space of 1 mm at the location where the titanium abutment meets the shelf area. Autocatalytic resin cement was used for bonding of abutment and zirconia prosthesis, and the maximum removal stress value was measured in units of Ncm by using the customized equipment of the cemented specimen. The Kruskal-Wallis test was used to compare the three groups by statistical analysis (${\alpha}=.05$), modified by post hoc test the Mann-Whitney U-test and the Bonferroni correction method were used to compare the two methods (${\alpha}=.017$). Results: There was no statistically significant difference in removal stress between the $30{\mu}m$ group and the $35{\mu}m$ group in the internal gap (P = .032), and there was a significant difference between the $30{\mu}m$ group and the $50{\mu}m$ group, between the $35{\mu}m$ group and the $50{\mu}m$ group (P < .017). Conclusion: Thus, the internal gap of computer-aided design affected the retention between the zirconia prosthesis and the titanium abutment.