• Title/Summary/Keyword: Internal Fixation

Search Result 455, Processing Time 0.035 seconds

The Short Term Clinical Follow-up Study for Hemiarthroplasty in Proximal Humeral Fracture (상완골 근위부 분쇄 골절에서의 상완골 두 치환술의 단기 추시 결과)

  • Sung, Chang-Meen;Cho, Se-Hyun;Jung, Soon-Taek;Hwang, Sun-Chul;Park, Hyung-Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.92-98
    • /
    • 2007
  • Introduction: The treatment of proximal humeral fracture is traditionally determined by Neer's classification system. The severely displaced three-part or four-part fracture is an indication for primary hemiarthroplasty. The current authors report the clinical results of 10 patients who received hemiarthroplasty for proximal comminuted fractures. The minimum follow-up period was 12 months. Materials and Methods: The current authors studied 10 patients who, between July 1999 and March 2005, each received hemiarthroplasty for a proximal humeral fracture of one shoulder. According to Neer's classification system, 5 of the patients had three-part fractures, and 5 of the patients had 4-part fractures. The mean interval between trauma and hemiarthroplasty was 6.1 days. The mean age of the 6 female and 4 male patients was 67.4 years(range: 56 to 76). Shoulder function was evaluated using the Constant score, the Simple Shoulder Test, and the modified UCLA score. Results: The mean Constant score was 51.4(range: 34 to 60). The mean modified SST score was 7.8 out of 12 tasks. Excluding the one patient who had also sustained an axillary artery rupture and a brachial plexus injury after the initial trauma, the mean Constant score for the remaining 9 patients was 53.5(range: 44 to 60), and the mean SST score was 7.2 tasks. The modified UCLA score averages for pain, function, and active forward flexion and strength were, respectively, 8.2($6{\sim}10$), 6.6($2{\sim}8$), and 6.9($4{\sim}8$). The total UCLA score was an average of 21.7($12{\sim}26$). Patients' the modified UCLA ratings were as follows: Excellent: 3, Good: 6, and Poor: 1. The patient with the poor outcome was the one who had also sustained the neurovascular injury. Patient's subjective satisfaction rating were as follows: Excellent: 2, Good: 7, and Poor: 1. Conclusion: Based on short term follow-up results, this study indicates that hemiarthroplasty is the treatment of choice for proximal humeral fractures on which it would be difficult to perform open reduction and internal fixation. Hemiarthroplasty is a useful treatment modality to prevent shoulder stiffness and to allow daily living tasks in elderly patients. However, restoration of muscle power and range of joint motion were not recovered satisfactorily.

Polarus Intramedullary Nail for Nonunion of Humerus neck (Polarus 골수정을 이용한 상완골 경부 불유합의 수술적 치료)

  • Kang, Ho-Jung;Kim, Sul-Gee;Yoon, Hong-Kee;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.112-123
    • /
    • 2007
  • Purpose: Evaluate the clinical results of humerus neck nonunion treated with Polarus intramedullary nail. Materials and Methods: 8 patients who underwent surgery for nonunion of humerus surgical neck fracture were included. All patients were female, the average age was 65 years. 5 out the total 8 cases initially received surgery, open reduction and internal fixation with metal plate in 1 case, Ender nail insertion in 2 cases, external fixator in 1 case and closed reduction and percutaneous pinning in 1 case. The other 3 non union cases initial received conservative managemnent. The average period of nonunion was 9 months in the operated group and 6.2 months in the conservative group. All 8 cases received closed reduction with intrameedullary Polarus nail and auto iliac bone graft. Union was confirmed radiologically, and functional evaluation was done with the UCLA functional criteria. Results: All 8 cases showed union on radiologic evaluation. Average time to union was 3.5 months, average follow up period was 27 months. Average UCLA shoulder evaluation score was 7.6 points preoperatively which improved to 26.3 points after surgery. Active shoulder flexion was 40.7 degrees preoperatiely which increased to 104 degrees after surgery. Shoulder abduction improved from 32.9 degrees preoperatively to 96.3 degrees after surgery. UCLA functional criteria was good in 5 cases and fair in 3 cases, which no poor cases. Conclusion: Polarus IM nailing and AIBG is a useful method for treating nonunion of humerus neck fracture with improvement in union and function.

Histological Observation of Bone Reaction with Relation to Surface Treatment of Titanium (생체합금 Titanium의 표면처리에 따른 골반응의 변화에 대한 조직학적 관찰)

  • Ahn, Myun-Whan;Choi, Yong-Sug;Ahn, Jong-Chul;Seo, Jae-Sung;Lee, Dong-Chul;Jang, Jae-Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.116-133
    • /
    • 1996
  • The biocompatibility of the titanium has been estabilished through various experimental studies such as cell culture toxicity test, pyrogen test, mutagen test and others. In order to confirm biocompatibility after fabrication of titanium and to clarify the difference between the bone reaction after insertion of the lathed titanium rods and the bone reaction after insertion of the finished and polished rods, both rods were implanted into the proximal femur of a rabbit. Histologic reactions in the bone were observed according to the ASTM standards at the intervals of 6 weeks, 12 weeks and 26 weeks after implantation. The result were as follows : In 6 weeks after implantation of lathed titanium rods, inflammatory reactions, such as minimal degree infiltration of polymorphonuclear leukocytes and lymphocytes were observed in all cases. This was thought to he caused by surgical trauma. However, inflammatory cell infiltration was not seen after implantation of polished and finished rods in all cases. The cellular infiltration and the histologic reaction of the hone after implantation of lathed group were significantly more pronounced than those after implantation of the finished group. In 12 weeks after implantation of lathed rods, two of four cases revealed a minimal degree of cellular infiltration. No inflammatory cell infiltration was demonstrated after implantation of the finished group. The cellular infiltration and histologic reaction seemed to be more pronounced in the lathed group, but they were not significant statistically. At 26 weeks after implantation of the lathed and finished group, there was no cellular infiltration in both groups. New bone formation was observed up 26 weeks, and no difference between lathed titanium rods and finished titanium rods were apparent. Mild bone necrosis was observed in 1 case out of 11 cases in which lathed titanium rods were implanted. Bone necrosis was not observed in the finished titanium rod group. Fibrosis was observed in both groups, but differences were not significant between the experimental groups. In the lathed titanium rods group and the shorter interval group, inflammatory cell infiltration was significantly higher. Finished titanium rods and longer interval groups had markedly decreased tendences in histologic reaction ratings. As a conclusion, although certificated titanium might be safe to use, difference of biocompatibility were observed depending on the method of surface finish. By identifying biocompatibility as a long-term standardized animal study, we can develop progressed internal fixation device that is safe for human beings.

  • PDF

Primary Bone Tumors in Hindfoot (후족부에 발생한 원발성 골종양)

  • Shin, Duk-Seop;Lee, Sung-Jun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: Primary bone tumors of hindfoot are uncommon compared with other locations, and there have been few large-group studies. This study was designed to analyze the characteristics and the clinical results of the primary bone tumors of hindfoot. Materials and Methods: Forty five cases in 44 patients who have been diagnosed from 1989 to 2011 were reviewed. The minimum follow-up period was 1 year. We retrospectively reviewed the medical records and images. Results: Twenty six cases were male and 18 cases were female. Mean follow-up period was 33.1 months and mean age was 25.1 years. Forty four cases were benign and 1 case was malignant. Thirty six cases occurred in calcaneus and 9 cases were in talus. The most common benign bone tumor was simple bone cyst (20 cases), followed by intraosseous lipoma (12 cases), and chondroblastoma (4 cases). In calcaneus, there were 18 cases of simple bone cyst, and 12 cases of intrasosseous lipoma. In talus, there were 3 cases of chondroblastoma, 2 cases of simple bone cyst, and 2 cases of intraossesous ganglion. Many patients with hindfoot bone tumors presented with pain, but some were found accidentally. Patients received surgical procedures, such as curettage and bone graft, open reduction and internal fixation, tumor resection, and below knee amputation. Conclusion: Primary bone tumors of hindfoot are rare and can be misdiagnosed as ankle sprain or contusion. Although most are benign, malignant tumors cannot be ruled out, so early diagnosis and appropriate treatment is important.

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

Trend and Further Research of Rice Quality Evaluation (쌀의 품질평가 현황과 금후 연구방향)

  • Son, Jong-Rok;Kim, Jae-Hyun;Lee, Jung-Il;Youn, Young-Hwan;Kim, Jae-Kyu;Hwang, Hung-Goo;Moon, Hun-Pal
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47
    • /
    • pp.33-54
    • /
    • 2002
  • Rice quality is much dependent on the pre-and post harvest management. There are many parameters which influence rice or cooked rice qualitys such as cultivars, climate, soil, harvest time, drying, milling, storage, safety, nutritive value, taste, marketing, eating, cooking conditions, and each nations' food culture. Thus, vice evaluation might not be carried out by only some parameters. Physicochemical evaluation of rice deals with amy-lose content, gelatinizing property, and its relation with taste. The amylose content of good vice in Korea is defined at 17 to 20%. Other parameters considered are as follows; ratio of protein body-1 per total protein amount in relation to taste, and oleic/linoleic acid ratio in relation to storage safety. The rice higher Mg/K ratio is considered as high quality. The optimum value is over 1.5 to 1.6. It was reported that the contents of oligosaccharide, glutamic acid or its derivatives and its proportionalities have high corelation with the taste of rice. Major aromatic compounds in rice have been known as hexanal, acetone, pentanal, butanal, octanal, and heptanal. Recently, it was found that muco-polysaccharides are solubilized during cooking. Cooked rice surface is coated by the muco-polysaccharide. The muco-polysaccharide aye contributing to the consistency and collecting free amino acids and vitamins. Thus, these parameters might be regarded as important items for quality and taste evaluation of rice. Ingredients of rice related with the taste are not confined to the total rice grain. In the internal kernel, starch is main component but nitrogen and mineral compounds are localized at the external kernel. The ingredients related with taste are contained in 91 to 86% part of the outside kernel. For safety that is considered an important evaluation item of rice quality, each residual tolerance limit for agricultural chemicals must be adopted in our country. During drying, rice quality can decline by the reasons of high drying temperature, overdrying, and rapid drying. These result in cracked grain or decolored kernel. Intrinsic enzymes react partially during the rice storage. Because of these enzymes, starch, lipid, or protein can be slowly degraded, resulting in the decline of appearance quality, occurrence of aging aroma, and increased hardness of cooked rice. Milling conditions concerned with quality are paddy quality, milling method, and milling machines. To produce high quality rice, head rice must contain over three fourths of the normal rice kernels, and broken, damaged, colored, and immature kernels must be eliminated. In addition to milling equipment, color sorter and length grader must be installed for the production of such rice. Head rice was examined using the 45 brand rices circulating in Korea, Japan, America, Australia, and China. It was found that the head rice rate of brand rice in our country was approximately 57.4% and 80-86% in foreign countries. In order to develop a rice quality evaluation system, evaluation of technics must be further developed : more detailed measure of qualities, search for taste-related components, creation and grade classification of quality evaluation factors at each management stage of treatment after harvest, evaluation of rice as food material as well as for rice cooking, and method development for simple evaluation and establishment of equation for palatability. On policy concerns, the following must be conducted : development of price discrimination in conformity to rice cultivar and grade under the basis of quality evaluation method, fixation of head rice branding, and introduction of low temperature circulation.

Oncologic Results and Functional Assessment of Limb Salvage Surgery in Primary Bone Tumors Around the Shoulder Girdle (견관절 주위 원발성 골 종양에서 사지 구제술의 종양학적 결과 및 기능적 평가)

  • Lee, Sang-Hoon;Yoo, Jae-Ho;Oh, Joo-Han;Suh, Sung-Wook;Kim, Han-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.8 no.3
    • /
    • pp.96-105
    • /
    • 2002
  • Purpose: The purpose of this study was to assess the oncologic results and functional outcomes of limb salvage surgery performed in patients of primary bone tumors of the shoulder girdle. Materials and Methods: Twenty-nine patients who underwent limb sparing resection for shoulder girdle neoplasm between 1982 and 2001 were analyzed. Follow up periods averaged 7 years and 1 month. Mean age of the patients was 35 (11~71) years. There were 14 males and 15 females. Primary malignant bone tumors of shoulder girdle (proximal humerus 21, scapula 3, both 1) were 23 cases; osteosarcomas 7, chondrosarcoma 14, parosteal osteosarcoma 1, hemangioendothelioma 1, and giant cell tumor of proximal humerus were 6 cases. Limb salvage surgery was performed by curettage and cementing in 7 patients, by cement molding arthroplasty in 10 patients, and by tumor prosthesis in 7 patients, by other method such as resection only, bone graft, arthrodesis in 5 patients. The Musculoskeletal Tumor Society functional rating system was used to assess functional outcomes. Results: One osteosarcoma and 2 chondrosarcoma patients died, and the survival of the salvaged limb was 88.6% at the final follow-up. There were 6 local recurrences, 2 lung metastases, 2 local recurrences and lung metastases. The functional outcome was 80%. There was statistically significant difference of functional results among the patients treated by cement filling (86%), cement molding arthroplasty and IM nailing (71%), and tumor prosthesis (83%). (p=0.034) There were three complications including 1 radial nerve palsy and 1 axillary nerve palsy, and 1 wound infection. Dislodgement of vascularized fibular graft in one patient was treated by internal fixation. Conclusion: Limb salvage surgery seems to be useful method to treat bone tumors of the shoulder girdle.

  • PDF

Identification and prevalence of trematode(Gen Azygia) and nematode(Gen Pingus) in Ophicephalus argus (가물치의 위장내 기생하는 흡충(Azygia속) 및 선충(Pingus속)의 동정과 감염상황)

  • Moon, Moo-hong;Lee, Eun-woo
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.1
    • /
    • pp.147-159
    • /
    • 1998
  • A survey of the internal parasites in 115 fishes of Ophicephalus argus was carried out in Kyungpook province during the period from January 1995 to November 1997. A species of trematode from the stomach and a species of nematode from the caeca of the fishes was discovered respectively. The trematode was identified as Azygia hwangtsinyi (Tsin, 1993) and the nematode as Pingus sinensis ($Hs\ddot{u}$, 1993). The fluke was pressed at thick of 0.1mm~0.2mm between slide glasses and fixed in 70% ethyl alcohol solution. The fluke was washed with tap water after fixation and stained with hematoxylin-carmin and mounted in balsam through routine methods. The nematode was fixed in 5% formalin solution and mounted with lactophnol or glycerine jelly. Morphology : Arygia hwantsinyi ; The fluke is elongate body with approximately parallel margins and rounded extremities in pressed preparations(Fig 1). The cuticle is unarmed. The oral sucker is ventro-subterminal in position. The ventral sucker is slightly smaller than oral sucker and positioned at 14.2% of body length from the oral sucker. The cirrus sac and genital pore is in mid-ventral line, slightly anterior to the ventral sucker. The oral sucker is succeeded by a well developed muscular pharynx. It is succeeded by a short inverted Y-shaped oesophagus. The inner wall of oesophagus is consisted of many fine folded membrane. The fine tubes of esophagus pass into the intestinal heads which are distended and presented a marked borderline between the fine tube and intestinal heads. The Intestinal heads start at level of pharynx and pass caudad in a zigzag course to end quite near caudal margin. The uterine coils occupy the intercecal area between the level of the cephalic margin of the ovary and about the level of the ventral sucker. The uterus is filled with many eggs. The testes are round or oval and placed one behind the other generally a little diagonally. The posterior testis is placed at level of 75.1% of body length. The ovary is oval, placed ahead the anterior testis. The shell gland not discernible outline is contacted with ovary ahead it. The vitelline glands are consisted of small oval vesicles. The vesicles occupy extracecal regions and between a little posterior of the ventral sucker and near caudal margin. Pingus sinensis : Female ; The cuticle is smooth and the cervical alae are well developed. The mouth opening is small, triangular, and without lips. The anterior end bears four sub-medial papillae. The oesophagus is divided into a muscular and glandular portion. The nerve ring is situated just at the junction of the muscular and glandular portions of the oesophagus. The vulva which has a prominent flap, is placed behind the middle of the body about one-third of the length of the worm from the posterior extremity. The vagina is strongly muscularised and after running anteriorly about $68{\mu}$, divides itself into two broad uterine tubes with an anterior and a posterior one. There are a few eggs in the uterine tubes. The tail is slender, straight and pointed. The ovary extends almost to the posterior extremity. Male : Male is smaller than female. The tail is pointed, curved and carrying well-developed caudal alae. A prominent muscular precloacal sucker is characteristic. The spicules are equal and short. There are four pairs of pedunculated pre-anal papillae, of which the most anterior pair are situated just at the level anterior to the muscular sucker. Two pairs of pedunculated papillae are present before the anus. There are five pairs of post-anal papillae of which the most anterior pair and the second counted from the posterior end are ventral and more marked than the ones which are situated laterally.

  • PDF

A Clinical Analysis of Femur Neck Fracture in Elderly Patients (노년층에서 대퇴경부 골절의 치료)

  • Ihin, Joo-Choul;Ahn, Myun-Whan;Seo, Jae-Sung
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.11-22
    • /
    • 1985
  • Femur neck fracture is well known as one of the major death cause after trauma in elderly patients, and unsolved fracture due to its frequent association with complications such as avascular necrosis and nonunion. Through meticulous evaluation of the patient, hip and surgeon's experiences, reduction of mortality and morbidity as well as rapid recovery of the patient to the preinjury social and ambulatory status without local complications and revision after treatment is urgently needed. Many factors about this fracture In itself were noted, but we have analyzed 18 femur neck fractures of the patients older than 50 years preliminarily according to age, fracture pattern, osteoporosis, etiology and method of treatment with its delay in association with major complications especially avascular necrosis and nonunion. The results are as follows; 1. Of these 18 fractures, 11 were in females, 8 were caused by minor trauma such as slip-down accident and 4 were associated with definite osteoporosis according to the Sing's classification. 2. Fracture pattern of these 18 are undisplaced in 4, displaced subcapital in 11, displaced transcervical in 3. 11 fractures in the patients older than 60 year are composed of 3 undisplaced or impacted fractures and 8 displaced subcapital fractures. 3. These 18 fractures were treated by closed reduction and Internal fixation with multiple pins in 13, and hemiarthroplasty in 4, but one was not treated to die after discharge from hospital. 4. 4 undisplaced or impacted fractures and 3 displaced transcervical fractures were not associated with any complications such as avascular necrosis or nonunion. But 4 of 6 displaced subcapital fractures were complicated by avascular necrosis, 3 of which were reduced in the varus position within 1 week, and the other was reduced in the good position on 1 week after trauma. There was no complication in 2 displaced subcapital fractures reduced in valgus position within 3 days after trauma. According to the above results, the prognosis of the femur neck fracture is dependent upon the fracture pattern and delay in its treatment. So it is inevitable to reduce the fracture in anatomical or valgus position as early as possible. But the arthroplasty may be needed in displaced subcapital fractures delayed for several days, with its reluction in extreme varus position or impossible and with pre-existing disease in the same hip Joint (total hip replacement).

  • PDF

A study of the cause of metal failure in treatment of femur shaft fracture - Fractographical and clinical analysis of metal failure- (대퇴골 간부 골절시 사용한 금속물의 금속부전(Metal failure)의 기전에 대한 연구)

  • Jeon, Chun-Bae;Seo, Jae-Sung;Ahn, Jong-Chul;Ahn, Myun-Whan;Ihn, Joo-Chyl
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.81-93
    • /
    • 1990
  • The author fractographically analyized the cause of metal failure(the first time this procedure has been used for this metal failure)and also analyized it clinically. In this study, I selected eight cases which have been analyized fractographically. In all these cases, the analysis was done after treatment of metal failure of implants internally fixed to femur shaft fractures at the Department of Orthopedic Surgery, Yeung-Nam University Hospital during the six year period from May 1983 to September 1989. 1. Metal failure occured in five dynamic-compression plates, one Jewett nail, one screw in Rowe plate, and one interlocking nail. 2. The clinical cause of metal failure was deficiency of medial butress in five cases, incorrect position of implant in one case, and incorrect selection of implant in two cases. 3. The time interval between internal fixation and metal failure was four months in one case, between five months to twelve months in six cases, three years in one case. 4. The fractographically analytical cause of metal failure was ; first, impact failure, one case, second, fatigue failure, six cases, machining mark(stress liser), four cases type : low consistent cyclic fatigue failure irregular cyclic fatigue failure third, stress corrosion crack, one case. 5. 316L Stainless Steel has good resistance to corrosion. However, when its peculiar surface film is destroyed by fretting, it shows pitting corrosion. This is, perhaps, the main cause of metal failure. 6. It is possible that mechanical injury occured in implants during the manufacturing of implants or that making a screw hole is the main cause of metal failure.

  • PDF