• 제목/요약/키워드: Internal Dosimetry

검색결과 63건 처리시간 0.029초

원자력 발전소 피폭자 건강영향평가 사례보고 (Cytogenetic and Medical Examination Report of Accidental Exposure of Nuclear Power Plant Worker using Multiple Assays)

  • 이정은;양광희;장윤균;정미선;김종순;진영우
    • Journal of Radiation Protection and Research
    • /
    • 제32권3호
    • /
    • pp.111-115
    • /
    • 2007
  • 원자력 발전소의 중수누출에 따른 삼중수소 농도증가에 의한 방사선 내부피폭과 이에 대한건강영향평가를 실시하였다. 전체 22명 가운데 13명에 대하여 검사를 실시하였으며, 이들의 내부피폭량은 $0{\sim}4.44\;mSv$ 였다. 일반혈액검사 중 백혈구수치의 변화를 이용하여 평가한 결과에서 결정적 영향에 대한 특이사항은 나타나지 않았으며, 생물학적 선량평가 방법을 이용한 체내피폭량은 $0{\sim}37\;mGy$로 확인되었다. 결론적으로 방사선 피폭은 허용한도를 초과하지 않았으며, 결정적 영향인 임상적 증상이 보이지 않았다. 이와 같이 의학적 징후와 선량평가 추정치와의 일치성은 사고시 특히 물리적 생물학적 선량평가가 유용함을 보여 준다.

Optimal Monitoring Intervals and MDA Requirements for Routine Individual Monitoring of Occupational Intakes Based on the ICRP OIR

  • Ha, Wi-Ho;Kwon, Tae-Eun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • 제45권2호
    • /
    • pp.88-94
    • /
    • 2020
  • Background: The International Commission on Radiological Protection (ICRP) has recently published report series on the occupational intakes of radionuclides (OIR) for internal dosimetry of radiation workers. In this study, the optimized monitoring program including the monitoring interval and the minimum detectable activity (MDA) of major radionuclides was suggested to perform the routine individual monitoring of internal exposure based on the ICRP OIR. Materials and Methods: The derived recording levels and the critical monitoring quantities were reviewed from international standards or guidelines by the International Atomic Energy Agency (IAEA), the International Organization for Standardization (ISO), and the European Radiation Dosimetry Group (EURADOS). The OIR data viewer provided by ICRP was used to evaluate the monitoring intervals and the MDA, which are derived from the reference bioassay functions and the dose coefficients. Results and Discussion: The optimal monitoring intervals were determined taking account of two requirement conditions on the potential intake underestimation and the MDA values. The MDA requirement values of the selected radionuclides were calculated based on the committed effective dose from 0.1 mSv to 5 mSv. The optimized routine individual monitoring program was suggested including the optimal monitoring intervals and the MDA requirements. The optimal MDA values were evaluated based on the committed effective dose of 0.1 mSv. However, the MDA can be adjusted considering the practical operation of the routine individual monitoring program in the nuclear facilities. Conclusion: The monitoring intervals and the MDA as crucial factors for the routine monitoring were described to suggest the optimized routine individual monitoring program of the occupational intakes. Further study on the alpha/beta-emitting radionuclides as well as short lived gamma-emitting nuclides will be necessary in the future.

방사선 전신 조사 : 기본 자료 측정 및 생체내에서 선량 측정 (Total Body Irradiation Technique : Basic Data Measurements and In Vivo Dosimetry)

  • 최동락;최일봉;강기문;신경섭;김춘추
    • Radiation Oncology Journal
    • /
    • 제12권2호
    • /
    • pp.219-223
    • /
    • 1994
  • This paper describes the basic data measurements for total body irradiation with 6 Mv photon beam including compensators design. The technique uses bilateral opposing fields with tissue compensators for the head, neck, lungs, and legs from the hip to toes. In vivo dosimetry was carried out for determining absorbed dose at various regions in 7 patients using diode detectors(MULTIDOSE,k Model 9310, MULTIDATA Co., USA). As a results, the dose uniformity of${\pm}3.5{\%}$(generally, within${\pm}10{\%}$can be achieved with out total body irradiation technique.

  • PDF

Development of Korean Male Body Model for Computational Dosimetry

  • Lee, Ae-Kyoung;Choi, Woo-Young;Chung, Min-Suk;Choi, Hyung-Do;Choi, Jae-Ick
    • ETRI Journal
    • /
    • 제28권1호
    • /
    • pp.107-110
    • /
    • 2006
  • The dimensions of the human body vary by age, sex, and race. The internal structure and outer dimensions of a body exposed to an electromagnetic field is important for accurate dosimetry. The average physical size of Korean adult males between the ages 18 to 24 was investigated, and a male volunteer was selected whose physical condition is within the physical standards, ${\pm}5%$. Magnetic resonance images and partially computerized tomography images of the volunteer were acquired. The intervals between the transverse images were 1 mm for the head and 3 mm for the rest of the body. About 30 different tissues were manually classified by an anatomist on the raw images, and the segmented images were implemented in the form of a text file appropriate for numerical formulation.

  • PDF

무선전력전송의 조사량 평가 시 전기장 영향 (Electric Field Effect on Numerical Dosimetry for Wireless Power Transfer System)

  • 박상욱
    • 한국전자파학회논문지
    • /
    • 제26권5호
    • /
    • pp.499-505
    • /
    • 2015
  • 전자기 공진 현상을 이용한 무선전력전송 시스템에 대한 조사량 평가 시 전기장의 고려 여부를 검토하였다. 인체로 인가되는 전기장과 자기장의 상대적인 크기가 조사량 평가 시에 중요한 지표가 되기 때문에, 이를 검토하기 위해 자기 다이폴 인근의 다양한 전자기장의 크기를 갖는 곳에 구형의 간이 인체 모델을 위치시키고, 구 모델 내부로 유도되는 전기장의 값을 이론과 수치해석을 통하여 구하고 비교하였다. 그 결과, 전기장을 무시할 수 없는 영역이 존재함을 확인하였으며, 이는 무선전력전송의 조사량 평가 시 외부 전기장에 대한 고려가 필요함을 알 수 있었다.

Application of the new ICRP iodine biokinetic model for internal dosimetry in case of thyroid blocking

  • Kwon, Tae-Eun;Chung, Yoonsun;Ha, Wi-Ho;Jin, Young Woo
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1826-1833
    • /
    • 2020
  • Administration of stable iodine has been considered a best measure to protect the thyroid from internal irradiation by radioiodine intake, and its efficacy on thyroid protection has been quantitatively evaluated in several simulation studies on the basis of simple iodine biokinetic models (i.e., three-compartment model). However, the new iodine biokinetic model adopted by the International Commission on Radiological Protection interprets and expresses the thyroid blocking phenomenon differently. Therefore, in this study, the new model was analyzed in terms of thyroid blocking and implemented to reassess the protective effects and to produce dosimetric data. The biokinetic model calculation was performed using computation modules developed by authors, and the results were compared with those of experimental data and prior simulation studies. The new model predicted protective effects that were generally consistent with those of experimental data, except for those in the range of stable iodine administration -72 h before radioiodine exposure. Additionally, the dosimetric data calculated in this study demonstrates a critical limitation of the three-compartment model in predicting bioassay functions, and indicated that dose assessment 1 d after exposure would result in a similar dose estimate irrespective of the administration time of stable iodine.

COMPUTATIONAL ANTHROPOMORPHIC PHANTOMS FOR RADIATION PROTECTION DOSIMETRY: EVOLUTION AND PROSPECTS

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Nuclear Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.239-250
    • /
    • 2006
  • Computational anthropomorphic phantoms are computer models of human anatomy used in the calculation of radiation dose distribution in the human body upon exposure to a radiation source. Depending on the manner to represent human anatomy, they are categorized into two classes: stylized and tomographic phantoms. Stylized phantoms, which have mainly been developed at the Oak Ridge National Laboratory (ORNL), describe human anatomy by using simple mathematical equations of analytical geometry. Several improved stylized phantoms such as male and female adults, pediatric series, and enhanced organ models have been developed following the first hermaphrodite adult stylized phantom, Medical Internal Radiation Dose (MIRD)-5 phantom. Although stylized phantoms have significantly contributed to dosimetry calculation, they provide only approximations of the true anatomical features of the human body and the resulting organ dose distribution. An alternative class of computational phantom, the tomographic phantom, is based upon three-dimensional imaging techniques such as magnetic resonance (MR) imaging and computed tomography (CT). The tomographic phantoms represent the human anatomy with a large number of voxels that are assigned tissue type and organ identity. To date, a total of around 30 tomographic phantoms including male and female adults, pediatric phantoms, and even a pregnant female, have been developed and utilized for realistic radiation dosimetry calculation. They are based on MRI/CT images or sectional color photos from patients, volunteers or cadavers. Several investigators have compared tomographic phantoms with stylized phantoms, and demonstrated the superiority of tomographic phantoms in terms of realistic anatomy and dosimetry calculation. This paper summarizes the history and current status of both stylized and tomographic phantoms, including Korean computational phantoms. Advantages, limitations, and future prospects are also discussed.

갑상선암 환자에 대한 방사성옥소 치료시 물리적 선량 측정 (Physical Dosimetry in Radioactive Iodine Treatment in the Patients with Thyroid Cancer)

  • 김명선;정내인;이재용;김종순;김종호;이명철;고창순;김희근;강덕원;송명재
    • 대한핵의학회지
    • /
    • 제28권1호
    • /
    • pp.124-132
    • /
    • 1994
  • 서론 : 방사성옥소는 갑상선암 환자에서 수술요법과 병용하여 많이 쓰이고 있으나 환자에 따라 방사성옥소 흡수량과 배설량, 암조직의 방사성옥소 섭취율이 차이가 나기 때문에 같은 양을 투여하더라도 치료효과나 부작용이 차이가 날 수 있다. 그러므로 본 연구에서는 체내 피폭된 물리적 선량을 측정하여 치료효과와 방사선영향의 정도를 비교하였다. 방법 : 수술요법을 시행한 분화된 갑상선암 환자 27명을 대상으로 하여 100mCi 150mCi, 200mCi의 방사성옥소를 투여하고 BEL DOSIMETRY PROTOCOL에 따라 방사선량을 구하고 반대수 용지위에 혈액 리터당 투여량에 대한 백분율의 로그값, 잔류량 백분율과 시간의 관계를 그래프로 그려 베타선량과 감마선량을 구한 뒤 총 물리학적 선량을 구하였다. 결과 : 1) 100mCi 투여군에서 물리적 선량은 평균 $56.54{\pm}13.02$ rad 이었고 150 mCi 투여군에서는 $76.83{\pm}19.97$ rad, 200mCi 투여군에서는 $95.08{\pm}25.51$ rad 이었고 각 평균값 사이에는 유의한 상관관계가 있었다. 2) 48시간후 체내 잔류율은 평균 26.34% 이었다. 3) 전이여부와 물리적 선량과의 사이에 유의한 상관관계는 없었다. 4) 갑상선 글로불린과 갑상선 자극 호르몬, Thallium scan으로 추적 관찰한 19명중 17명이 치유되었다. 5) 백혈구, 림프구, 호중구, 혈소판 모두 4-6주에 최저치로 감소한뒤 3개월내에 회복되었다. 6) 물리적 선량과 생물학적 선량 사이에 유의한 상관관계는 없었다. 결론 : 우리나라에서 수술후 갑상선암의 치료에 통상적으로 사용하는 방사성옥소의 양(100-200mCi)은 일시적 골수부전과 경도의 염색체 이상을 초래하나 혈액내방사선 조사량이 안전용량 범위(200rad)에 속하며 48시간 후 체내잔류량은 서양인과 큰 차이가 없었다.

  • PDF

혈관성형술 후 재협착 방지 치료에 사용하기 위한 원통형 풍선 Re-188-DTPA의 선량 분포와 내부피폭 선량 (Dosimetry and Medical Internal Radiation Dose of Re-188-DTPA for Endovascular Balloon Brachytherapy Against Restenosis after Coronary Angioplasty)

  • 이진;이동수;신승애;정재민;정준기;이명철
    • 대한핵의학회지
    • /
    • 제33권2호
    • /
    • pp.163-171
    • /
    • 1999
  • 목적 : 혈관 재협착을 막기 위하여 풍선에 용액 형태의 베타 방출 핵종을 넣어 사용하는 방법이 연구되고 있다. 이 연구에서는 Re-188-DTPA를 풍선에 넣어 사용하는 경우 주위 혈관에 대한 에너지 분포와 용액이 풍선에서 누출되는 경우 주요 장기와 전신에의 흡수 선량을 계산하였다. 대상 및 방법: 전자와 광자의 물에서의 운반은 몬테카를로 EGS4 코드를 사용하였으며 풍선은 직경 3 mm, 길이 20 mm의 원기둥으로 대체하였다. 개에게 Re-188-DTPA 370MBq를 주사하여 감마카메라로 영상을 얻어 주요장기의 잔류 시간을 구하였고 전신과 주요 장기에의 흡수 선량은 MIRDOSE3와 ICRP Dynamic Bladder모델을 사용하여 계산하였다. 결과: 3,700 MBq/1ml을 100초 동안 조사하였을 때 풍선 표면에 전달된 에너지는 17.6 Gy, 표면으로부터 0.5 mm 떨어진 곳에서 9.5 Gy이었다. 풍선에서 용액이 누출되었을 경우 전신에 0.005 mGy/MBq, 방광에 2.39 mGy/MBq의 흡수 선량이 전달되었다. 결론: 관상동맥 풍선 성형술용 풍선에 Re-188-DTPA를 주입하여 사용하는 방법이 목표선량을 조사하는 데 적절하고 방사선 안전의 관점에서 사용 가능한 방법이라고 생각한다.

  • PDF