Comparing Inhaler Use Technique Based on Inhaler Type in Elderly Patients with Respiratory Disease

  • Lee, Ha Youn;Song, Jin Hwa;Won, Ha-Kyeong;Park, Yeonkyung;Chung, Keun Bum;Lim, Hyo-Jeong;Ahn, Young Mee;Lee, Byoung Jun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.1
    • /
    • pp.46-54
    • /
    • 2021
  • Background: The aim of this study was to investigate inhaler device handling in elderly patients. Inhaler devices with respect to misuse and error correction were also compared. Methods: Inhaler use technique was assessed using standardized checklists at the first visit and 3-month follow-up visit after retraining. The primary outcome was difference in the acceptable use ratio among inhaler devices. Secondary outcomes included differences in error correction, the most common step of misuse, and factors affecting the accuracy of inhaler use. Results: A total of 251 patients (mean age, 76.4 years) were included. The handling of 320 devices was assessed in the study. All patients had been trained before. However, only 24.7% of them used inhalers correctly. Proportions of acceptable use for Evohaler, Respimat, Turbuhaler, Ellipta, and Breezhaler/Handihaler were 38.7%, 50.0%, 61.4%, 60.8%, and 43.2%, respectively (p=0.026). At the second visit, the acceptable use ratio had increased. There were no significant differences among inhaler types (Evohaler, 63.9%; Respimat, 86.1%; Turbuhaler, 74.3%; Ellipta, 64.6%; and Breezhaler/Handihaler, 65.3% [p=0.129]). In multivariate analysis, body mass index, Turbuhaler, and Ellipta showed positive correlations with acceptable use of inhalers, whereas Chronic Obstructive Pulmonary Disease Assessment Test score showed a negative correlation. Conclusion: Although new inhalers have been developed, the accuracy of inhaler use remains low. Elderly patients showed more errors when using pressurized metered-dose inhalers than using dry powder inhalers and soft-mist inhalers. However, there were no significant differences in misuse among inhaler devices after individual training. Results of this study suggests that repeat training is more important than inhaler type.

Biological Dosimetry of In Vitro Irradiation with Radionuclides : Comparison of Whole Blood, Lymphocyte and Buffy Coat Culture (전혈, 림프구와 백혈구 연층 각각의 방사성 동위원소 체외 조사 후 배양을 이용한 생물학적 선량측정)

  • Kim, Jong-Ho;Lee, Dong-Soo;Choi, Chang-Woon;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Chong-Soon;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.125-132
    • /
    • 1995
  • The purpose of this study was to establish mononuclear cell cultures such as lymphocytes or buffy coat for the biological dosimetry of in vitro Irradiation of the radionuclide Tc-99m in order to exclude the effect of residual doses seen in the cultures of whole blood. Biological do simetry of Tc-99m on cultured mononuclear cells at doses ranging from 0.05 to 6.00 Gy, by scoring unstable chromosomal aberrations(Ydr) observed in cultured lymphocytes, were performed using peripheral venous blood of healthy normal person. The results showed that; (1) In vitro irradiation of radioisotope in separated lymphocyte or buffy coat showed trace amount of residual doses of isotope after washing. Residual doses of isotopes are increased in proportion to exposed time and irradiated dose without difference between I-131 and Tc-99m. (2) We obtained these linear-quadratic dose response equations in lymphocyte and buffy coat culture after in vitro irradiation of Tc-99m, respectively (Ydr = 0.001949 $D^2$ +0.006279D + 0.000185; Ydr= 0.002531 $D^2$-0.003274 D+0.003488). In conclusion, the linear quadratic dose-response equation from in vitro irradiation of Tc-99m with lymphocyte and buffy coat culture was thought to be useful for assessing Tc-99m induced biological effects. And mono-nuclear cell cultures seem to be the most appropriate experimental model for the assessment of biological dosimetry of internal irradiation of radionuclides.

  • PDF

Toxicological Effect of Samultang (Herbal Medicine) Administration in the Pregnant Rats and Fetuses - Focusing on dose-response Relationship - (사물탕의 용량별 투여가 임신 랫드와 태자에 미치는 독성학적 연구)

  • Jeon, Sung-Jin;Shin, Heon-Tae;Kim, Kyung-Tae;Park, Hae-Mo;Lee, Sun-Dong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.14 no.3
    • /
    • pp.1-12
    • /
    • 2010
  • Objective : Samulatang (herbal description) is much used for women's disease in Korean Traditional Medicine. The aim of this study is to evaluate reproductive toxic effect by Samultang in pregnant rats and fetuses, and ascertain a dose-response relationship Method : Pregnant Sprague-Dawley rats were administered with the Samultang at single, double and quadruple dose for 20 days, orally. Pregnant rats were sacrificed at 20th day of gestation, and observed internal and reproductive organs. Live fetuses of gestation were randomly selected and fixed in 95% ethanol. Fetuses were stained with alcian blue and alizarin red S. We observe maternal body weight,, index associated pregnancy, and skeletal malformations in fetus Result : Maternal body weight of Samultang treated group has increased, side effect was not found in maternal body compared to that of control group. There were no significant difference in internal and reproductive organs. Double concentration administered group had lowest value in number of implantation, live fetuses, implantation rate and delivery rate, Also double concentration administered group showed higher early and late resorption rate than the other group. But, these are not significant. In the sex ratio, number of females, bigger than number of males in all Samultang administered groups. The fetuses of dams treated with Samultang didn't showed external and skeletal malformation. Vertebral and sternal variations were observed in single, double and quadruple concentration administered group but, compared to the control, those variations were insignificant. There were no significant changes in number of ribs, cervical, thoracic, lumber, sacral and caudal vertebrae Conclusion : Samultang is not expected to affect on pregnant rats and fetus about maternal body weight and number of live fetuses. There were no significant changes in organ weight, reproductive organs. Although skeletal variations were showed in vertebrae and sternum, treated groups were shown insignificant changes in skeletal variation

Assessment of Inhalation Dose Sensitivity by Physicochemical Properties of Airborne Particulates Containing Naturally Occurring Radioactive Materials (천연방사성물질을 함유한 공기 중 부유입자 흡입 시 입자의 물리화학적 특성에 따른 호흡방사선량 민감도 평가)

  • Kim, Si Young;Choi, Cheol Kyu;Park, Il;Kim, Yong Geon;Choi, Won Chul;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.216-222
    • /
    • 2015
  • Facilities processing raw materials containing naturally occurring radioactive materials (NORM) may give rise to enhanced radiation dose to workers due to chronic inhalation of airborne particulates. Internal radiation dose due to particulate inhalation varies depending on particulate properties, including size, shape, density, and absorption type. The objective of the present study was to assess inhalation dose sensitivity to physicochemical properties of airborne particulates. Committed effective doses to workers resulting from inhalation of airborne particulates were calculated based on International Commission on Radiological Protection 66 human respiratory tract model. Inhalation dose generally increased with decreasing particulate size. Committed effective doses due to inhalation of $0.01{\mu}m$ sized particulates were higher than doses due to $100{\mu}m$ sized particulates by factors of about 100 and 50 for $^{238}U$ and $^{230}Th$, respectively. Inhalation dose increased with decreasing shape factor. Shape factors of 1 and 2 resulted in dose difference by about 18 %. Inhalation dose increased with particulate mass density. Particulate mass densities of $11g{\cdot}cm^{-3}$ and $0.7g{\cdot}cm^{-3}$ resulted in dose difference by about 60 %. For $^{238}U$, inhalation doses were higher for absorption type of S, M, and F in that sequence. Committed effective dose for absorption type S of $^{238}U$ was about 9 times higher than dose for absorption F. For $^{230}Th$, inhalation doses were higher for absorption type of F, M, and S in that sequence. Committed effective dose for absorption type F of $^{230}Th$ was about 16 times higher than dose for absorption S. Consequently, use of default values for particulate properties without consideration of site specific physiochemical properties may potentially skew radiation dose estimates to unrealistic values up to 1-2 orders of magnitude. For this reason, it is highly recommended to consider site specific working materials and conditions and use the site specific particulate properties to accurately access radiation dose to workers at NORM processing facilities.

Short-term Evaluation of a Comprehensive Education Program Including Inhaler Training and Disease Management on Chronic Obstructive Pulmonary Disease

  • Yoo, Kwang Ha;Chung, Wou Young;Park, Joo Hun;Hwang, Sung Chul;Kim, Tae-Eun;Oh, Min Jung;Kang, Dae Ryong;Rhee, Chin Kook;Yoon, Hyoung Kyu;Kim, Tae-Hyung;Kim, Deog Kyeom;Park, Yong Bum;Kim, Sang-Ha;Yum, Ho-Kee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.4
    • /
    • pp.377-384
    • /
    • 2017
  • Background: Proper education regarding inhaler usage and optimal management of chronic obstructive pulmonary disease (COPD) is essential for effectively treating patients with COPD. This study was conducted to evaluate the effects of a comprehensive education program including inhaler training and COPD management. Methods: We enlisted 127 patients with COPD on an outpatient basis at 43 private clinics in Korea. The patients were educated on inhaler usage and disease management for three visits across 2 weeks. Physicians and patients were administered a COPD assessment test (CAT) and questionnaires about the correct usage of inhalers and management of COPD before commencement of this program and after their third visit. Results: The outcomes of 127 COPD patients were analyzed. CAT scores ($19.6{\pm}12.5$ vs. $15.1{\pm}12.3$) improved significantly after this program (p<0.05). Patients with improved CAT scores of 4 points or more had a better understanding of COPD management and the correct technique for using inhalers than those who did not have improved CAT scores (p<0.05). Conclusion: A comprehensive education program including inhaler training and COPD management at a primary care setting improved CAT scores and led to patients' better understanding of COPD management.

Clinical Experience of Photodynamic Therapy in Five Patients with Advanced Lung Cancer (진행성 폐암에서 광역동 치료로 호전된 5례에 관한 임상적 경험)

  • Kim, Yang-Ki;Lee, Young-Mok;Kim, Ki-Up;Uh, Soo-Taek;Kim, Yong-Hoon;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.1
    • /
    • pp.72-77
    • /
    • 2004
  • Background : A tracheobronchial obstruction in lung cancer is associated with significant morbidity and mortality due to dyspnea, cough, hemoptysis, and recurrent respiratory infection. It is well known that one of standard treatments is photodynamic therapy (PDT) in tracheobronchial obstruction after radiotherapy, chemotherapy, and/or surgery. We reported here the role of PDT in airway obstruction in patients advanced lung cancer. Method : Pre-treatment protocol consisted of clinical, radiologic, and bronchoscopic examination, pulmonary function test, and assessment of Karnofsky performance status. A 2 mg/kg of porfimer sodium was injected intravenously, and then followed by cylindrical and/or interstitial irradiation with 630 nm of laser after 48 hours. The repeated bronchoscopy for debridement of necrotic tissue and re-illumination was performed after 48 hours. Result : Improved airway obstruction and selective tumor necrosis were achieved by photodynamic therapy in all cases. Dyspnea and performance status were improved in three cases. A purulent sputum, fever and hemoptysis were improved in one of five cases. After PDT, all patients showed temporarily aggravation of dyspnea, two of five showed febrile reaction for a few days and nobody presented photosensitivity reaction, hemoptysis and respiratory failure. Conclusion : Our experiences of PDT are effective in palliation of inoperable advanced lung cancer in terms of tracheobronchial obstruction.

Comparative Analyses of the Internal Radiation Exposures due to Food Chain Pathway Using FOOD III Code (FOOD III 코드를 이용한 섭식경로 내부피폭 비교해석)

  • Choi, Yong-Ho;Chung, Kyu-Hoi;Kim, Jin-Kyu;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.41-51
    • /
    • 1988
  • In order to develop a food-chain computer code suitable to the environmental conditions of Korea, the FOOD III code was partially modified. The excution results for Korean male-adult were compared to those from the Canadian version of FOOD III to deduce a more realistic approach in dose assessment. The amounts of Mn-54, Co-58, Co-60, I-131 and I-132 released from Kori unit 1 in1984 were used as the source terms for the sample calculation. The maximum atmospheric dispersion factor(X/Q) value on the site boundary was applied. Through the code modification, organ doses decreased by about $20{\sim}70%$ and the effective committed dose equivalent by about 40% to be $7.935{\times}10^{-6}Sv/y$ which is 0.16% of the ICRP limit, $5{\times}10^{-3}Sv/y$.

  • PDF

Role of Krebs von den Lungen-6 (KL-6) in Assessing Hypersensitivity Pneumonitis

  • Mostafa, Amira Ismail;Salem, Ayman Elsayed;Ahmed, Heba Allah Moussa;Bayoumi, Aml Ibrahim;Halim, Radwa M. Abdel;Samie, Rasha M. Abdel
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.3
    • /
    • pp.200-208
    • /
    • 2021
  • Background: Hypersensitivity pneumonitis (HP) is an increasingly recognized form of diffuse parenchymal lung disease. Krebs von den Lungen-6 (KL-6) is now classified as a human MUC1 mucin protein, and regenerating type II pneumocytes are the primary cellular source of KL-6/MUC1 in the affected lungs of patients with interstitial lung diseases (ILD). Serum KL-6/MUC1 levels have been demonstrated to be useful for the evaluation of various ILD. To determine the role of circulating KL-6 in evaluating the disease activity and management of HP. Methods: An observational cross-sectional study was conducted on 51 patients with HP and 20 healthy controls. Serum KL-6 levels were measured in both groups. Patients were further assessed based on chest high-resolution computed tomography (HRCT), pulmonary function test, 6-minute walk test, echocardiography, bronchioalveolar lavage, and/or transbronchial biopsy. Patients were divided into the fibrotic and non-fibrotic groups according to the HRCT findings. Results: The median serum KL-6 levels were significantly higher in HP patients as compared to the control group. The median serum KL-6 levels were found to be higher in the non-fibrotic HP group (1,900 IU/mL) as compared to the fibrotic group (1,200 IU/mL). There was a significant inverse correlation between serum KL-6 serum level and the dose of steroids as well as the duration of steroid therapy. Conclusion: The presence of higher KL-6 levels in the non-fibrotic HP group implies its enhanced production by regenerating pneumocytes in response to alveolar injury. The significant association between serum KL-6 levels and the dose and the duration of steroid therapy emphasizes the significant role of steroids in the stabilization of the disease.

An Open-Label, Multicentre, Observational, Post-Marketing Study to Monitor the Safety and Effectiveness of Umeclidinium/Vilanterol in Korean Patients

  • Eun-Yeong Cho;Jung-Eun Cho;Eun-Bin Lee;Seung Soo Yoo;Jung Hyun Chang
    • Tuberculosis and Respiratory Diseases
    • /
    • v.86 no.1
    • /
    • pp.33-46
    • /
    • 2023
  • Background: Umeclidinium/vilanterol (UMEC/VI; ANORO ELLIPTA, GSK) is a commonly used dual bronchodilator. This study evaluated the safety and effectiveness of UMEC/VI in Korean patients with chronic obstructive pulmonary disease (COPD) over a 6-year period. Methods: This was an open-label, multicentre, observational, post-marketing surveillance study. A total of 3,375 patients were enrolled consecutively in 52 hospitals, by 53 physicians, between July 2014 and July 2020. Patients who were administered UMEC/VI (fixed-dose 62.5 ㎍/25 ㎍) at least once and were monitored for safety and effectiveness were included in the analysis. Incidence and severity of adverse events (AEs) reported after administrating at least one dose of UMEC/VI were monitored, including unexpected adverse events (UAEs) and adverse drug reactions (ADRs). Effectiveness of UMEC/VI after 24 weeks of administration was also assessed using physician's evaluation (effective, ineffective/no change, worsening, indeterminable) and lung function improvement. Results: Of 3,375 patients, 3,086 were included in the safety assessment group (mean age±standard deviation: 69.76±8.80 years; 85.9% male [n=2,652]; 73.1% aged ≥65 years [n=2,255]). The overall incidence of AEs was 28.8% (n=890), of which 2.2% (n=67) were ADRs. Serious AEs and UAEs were reported in 181 (5.9%) and 665 (21.6%) patients, respectively, and two patients (<0.1%) reported unexpected severe ADR. Of the 903/3,086 patients analysed for effectiveness, most (82.8%, n=748) showed overall disease improvement after UMEC/VI treatment. Conclusion: This study confirmed UMEC/VI administered to Korean patients according to the prescribing information was well-tolerated and can be considered an effective option for COPD treatment.

The Determination of Radon Progeny Concentration in Controlled Radon Environment (라돈을 제어하는 환경에서 라돈 자핵종의 농도 결정)

  • Seo, Kyung-Won;Lee, Byung-Kee
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.37-51
    • /
    • 1993
  • A standard radon chamber and a radon generator adjusted by ventilation system which had used in this research were assumed to calculate theoretically the concentration of radon progeny using Jacobi model theory. On the one hand, the filter sampled from the radon standard chamber and the radon generator was measured and analysed by the alpha spectrometry method. It is clear that measured result shows a good agreement with theoretical result. Therefore, it is observed that this research can made a great contribution to more accurate internal dose assessment by alpha emission of radon progeny in indoor radon environment, and fast individual measurement and determination of concentration for radon progeny.

  • PDF