• 제목/요약/키워드: Internal Cavity

검색결과 395건 처리시간 0.027초

뉵血에 대한 文獻的 考察 (外治法을 中心으로) (A Literature Study of the Epistaxis (A Focus of External Treatment))

  • 김성훈;유미경;정동환;심상희;박수연;김종한;최정화
    • 한방안이비인후피부과학회지
    • /
    • 제16권3호
    • /
    • pp.1-37
    • /
    • 2003
  • The epistaxis is commonplace and temporary disease in the field of ENT. In most cases, it is a slight illness, but sometimes, it leads to death because of copious bleeding. The first treatment of epistaxis is stoping hemorrhage, but the real state of treatment in oriental medical is not thoroughgoing enough. So we referred to oriental medical journals and sundry records about etiology and remedy of epistaxis, we got this results. 1. The etiology of epistaxis was mostly bleeding due to heat in the blood by dysfunction of Jang and Bu Gi, there were affection wind-cold by exopathogen, spleen heat to liver, excessive fire of lung meridian, stagnated fire-heat of upper Cho, excessive drinking, bruise and so on. 2. The treatment was used much to remove heat from the blood and activating blood, in case of getting no better, it's used to enriching the blood or clear Gi. 3. The internal remedy of epistaxis was the most used 20times SeogakJihwangtang(犀角地黃湯) to remove heat from the blood and activating blood, and used Jihwangtang(地黃湯), Samhwangbohyultang(三黃補血湯), Jiyuksan(止육散), hueksinsan(黑神散), etc. The drugstuffs were the most used 51times Radix Rehmanniae Preparata((生地黃) to clear heat and remove heat from the blood, produce the body fluids, yin, and used Radix Paeoniae Alba(芍樂) and Radix Glycyrrhizae(甘草), Radix Angelicae Gignatis(當歸), Radix Scutellariae(黃岑), Rhizoma Coptidis(黃連) and Fructus Gardeniae(梔子), etc. 4. The external medical treatment of epistaxis was the most used 16times spraying the granular medication into the cavity and attaching Allii Bulbus(大蒜) to center of the sole or binding the middle finger, etc.

  • PDF

치과용 접착제(Dental adhesive)를 사용한 제5급 복합레진수복물의 변연누출에 관한 실험적 연구 (IN VITRO STUDY ON THE MARGINAL LEAKAGE OF THE CLASS V COMPOSITE RESTORATION WITH DENTAL ADHESIVE)

  • 정근철;박동수;이찬영;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.135-144
    • /
    • 1984
  • This study was undertaken to evaluate the degree of the marginal leakage of composite restoration with 3 brands of dental adhesives by means of the dye penetration at the enamel and dentinal margins. 150 cavities of class V were prepared on the buccal and lingual surfaces of 75 extracted anterior and premolar teeth, which were devided into 3 groups. The cavities were filled with composite resin, Silar$^{(R)}$ (3M) and Heliosit$^{(R)}$ (Vivadent) after application of the dental adhesives, specifically Scotchbond$^{(R)}$ (3M) which is essentially composed with halophosphorus ester of Bis-GMA, Dentin Adhesit$^{(R)}$ (Vivadent) which is polyurethane resin, and Enamel Bond$^{(R)}$ (3M) which is a product of Bis-GMA with low viscosity at internal surfaces and margins of the cavities. All specimens were immersed in $37^{\circ}C$, 0.5% methylene blue solution for 24 hours after thermocycling at $4^{\circ}C$ and $60^{\circ}C$, embedded in acrylic resin, and sectioned with diamond disk into two parts. The sectioned specimens observed with the light microscope. The following results were obtained: 1. The group filled with Scotchbond$^{(R)}$-Silar$^{(R)}$ the other two groups at the enamel margins. 2. No significant difference in the degree of the marginal leakage had appeared between Dentin Adhesit$^{(R)}$-Heliosit$^{(R)}$ group an d Enamel Bond$^{(R)}$-Silar$^{(R)}$ group at the enamel margins. 3. Severe marginal leakage with penetration of dye to the floor of cavity had appeared from the all three groups and no significant difference in the degree of marginal leakage existed between the three groups at the dentinal margins.

  • PDF

사냑형 간섭계 광섬유 센서를 이용한 변압기유 내에서의 외부 음향 주파수 모니터링 (Applied Sound Frequency Monitoring in the Transformer Oil Using Fiber Optic Sagnac Interferometer)

  • 이종길;이승홍
    • 한국음향학회지
    • /
    • 제34권4호
    • /
    • pp.288-294
    • /
    • 2015
  • 광섬유 사냑 간섭계는 음향 및 진동과 같은 물리적 변화량을 탐지하는 센서로 잘 개발되어 있다. 본 논문에서는 변압기유가 채워진 원통형 캐비티에 음압이 발생되었을 때 한 개의 루프내에 설치된 광섬유 배열 센서를 이용하여 음향을 탐지하였다. 서로 다른 외부 음향 주파수 $f_1$$f_2$를 피에조 재료를 이용하여 발생시키고 주파수는 5 kHz에서 90 kHz까지로 선정하였다. 실험 결과 광섬유 센서는 하모닉 성분인 $f_1$, $f_2$, $2f_1$, $2f_2$, ${\mid}f_1-f_2{\mid}$, ${\mid}f_1+f_2{\mid}$의 주파수를 탐지하였다. 제안된 광섬유 센서 배열은 변압기 내의 부분 방전으로 인한 음압과 진동과 같은 물리량을 모니터링 하는데 적용할 수 있을 것으로 판단된다.

543 nm 헬륨네온 레이저의 주파수 안정화를 위한 I2 포화흡수분광 (I2-Saturated Absorption Spectroscopy for Frequency-Stabilization of He-Ne Laser at 543 nm)

  • 김경찬;엄년식;홍주현;서호성
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.859-865
    • /
    • 2010
  • 본 연구는 543 nm 헬륨네온 레이저의 주파수 안정화를 위한 $^{127}I_2$ 포화흡수분광 장치의 설계와 제작에 관한 것이다. 온도와 PZT 변화에 의한 레이저관 길이 가변을 이용하여 543 nm 헬륨네온 레이저의 주파수를 주사시켰다. 3차 고조파 신호을 얻기 위해 PZT 변조 가능한 레이저 출력경을 이용하여 주파수 변조를 하였다. 그 결과, $^{127}I_2$용 B-X 시스템의 R(12) 26-0에서 R(106) 28-0의 천이를 가지는 초미세구조 분광은 포화흡수분광기를 사용한 3차 미분신호에서 관찰되었다. 또한, 전형적인 초미세구조 분광 신호의 신호대 잡음비는 약 30:1 로 얻어졌다.

접착형 구조 금 인레이의 접착 형태, 강도 및 파절 양태에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON ADHESION PATTERN, ADHESION STRENGTH AND FRACTURE PATTERN OF THE ADHESIVE CAST GOLD INLAY)

  • 한승렬;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.64-72
    • /
    • 1994
  • Zinc Phosphate Cement hand been used for about more than 100 years in luting of cast gold inlay. But many scientists had been trying to develop the new form of luting agent because the ZPC hand shown the lack of adhesiveness on the tooth structure and the toxicity to the pulp tissue. Recently many researches about the surface treatment of the cast body are being done to increase the adhesion of cement to it. The conventional Class I gold inlays were fabricated in the 20 permanent molars. After the internal surface of the cast body was sandblasted with $Al_2O_3$ particles and was tin-plated, the inlays were cemented with adhesive cement [G I cement and resin cement(Super-Bond & $Panavia_{EX}$)] and the evaluation on the adhesion pattern, adhesive strength and the fracture pattern of the adhesive cast gold inlay was compared to that of the cast gold inlay cemented conventionally with ZPC. The results were as follows : 1. The surface roughness of the cast body was increased significantly after sandblasting with the $Al_2O_3$ particles and the tin oxide layer, which was consisted of round particles, came into being. 2. The bond strength was in the order of Super-Bond, ZPC, Fuji I, $Panavia_{EX}$ group. The group cemented with Super-Bond showed statistically greater strength than the other groups(p<0.05). 3. The group cemented with ZPC was fallen apart by principal adhesion failure and that with Fuji I was by complete adhesion failure. But the group with Super-Bond showed pricncipal cohesive failure pattern and in the group with $Panavia_{EX}$, complete cohesive fracture pattern was shown and small protion of tooth structure was fractured out with cast body and the fractured surface showed the figure just as the enamel prism. 4. Various gaps were shown at the pulpal side regardless of little gap at the side walls of the cavity in all groups. Only the Super-Bond was attached to the tooth structure and the other cements were detached from both the tooth and the cast body.

  • PDF

Identification and Prevalence of Globocephalus samoensis (Nematoda: Ancylostomatidae) among Wild Boars (Sus scrofa coreanus) from Southwestern Regions of Korea

  • Ahn, Kyu-Sung;Ahn, Ah-Jin;Kim, Tae-Hoon;Suh, Guk-Hyun;Joo, Kyoung-Woong;Shin, Sung-Shik
    • Parasites, Hosts and Diseases
    • /
    • 제53권5호
    • /
    • pp.611-618
    • /
    • 2015
  • This study describes the first record of Globocephalus samoensis (Nematoda: Ancylostomatidae) recovered in wild boars from southwestern regions of Korea. Gastrointestinal tracts of 111 Korean wild boars (Sus scrofa coreanus) hunted from mountains in Suncheon-si, Gwangyang-si, and Boseong-gun between 2009 and 2012 were examined for their visceral helminths. G. samoensis, as identified by morphological characteristics of the head and tail, were recovered from the small intestine of 51 (45.9%) wild boars. Worms were found from 7 of 28 wild boars (25.0%) from Suncheon-si, 40 of 79 (50.6%) from Gwangyang-si, and all 4 (100%) from Boseong-gun. The length of adult females was $7.2{\pm}0.5mm$, and the thickest part of the body measured the average $0.47{\pm}0.03mm$, while those of males were $6.52{\pm}0.19$ and $0.37{\pm}0.02mm$, respectively. The buccal cavity was equipped with a pair of large and bicuspid subventral lancets near the base of the capsule. The average length of spicules of males was $0.45{\pm}0.02mm$. By the present study, G. samoensis is recorded for the first time in southwestern regions of Korea. Additionally, morphological characteristics and identification keys provided in the present study will be helpful in the faunistic and taxonomic studies for strongylid nematodes in both domestic and wild pigs. The infection of G. samoensis apparently did not elicit pathologic lesions, as revealed by macroscopic observation during the autopsy of all wild boars in this study.

High-resolution ALMA Study of the Proto-Brown-Dwarf Candidate L328-IRS

  • Lee, Chang Won;Kim, Gwanjeong;Myers, Philip C.;Saito, Masao;Kim, Shinyoung;Kwon, Woojin;Lyo, A-Ran;Soam, Archana;Kim, Mi-Ryang
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.39.1-39.1
    • /
    • 2018
  • We present our observational attempts to precisely measure the central mass of a proto-brown dwarf candidate, L328-IRS, in order to investigate whether L328-IRS is in the substellar mass regime. Observations were made for the central region of L328-IRS with the dust continuum and CO isotopologue line emission at ALMA band 6, discovering the detailed outflow activities and a deconvolved disk structure of a size of ${\sim}87AU{\times}{\sim}37AU$. We investigated the rotational velocities as a function of the disk radius, finding that its motions between 130 AU and 60 AU are partially fitted with a Keplerian orbit by a stellar object of ${\sim}0.30M_{\odot}$, while the motions within 60 AU do not follow any Keplerian orbit at all. This makes it difficult to lead a reliable estimation of the mass of L328-IRS. Nonetheless, our ALMA observations were useful enough to well constrain the inclination angle of the outflow cavity of L328-IRS as ${\sim}66^{\circ}$ degree, enabling us to better determine the mass accretion rate of ${\sim}8.9{\times}10^{-7}M_{\odot}yr-1$.From assumptions that the internal luminosity of L328-IRS is mostly due to this mass accretion process in the disk, or that L328-IRS has mostly accumulated the mass through this constant accretion rate during its outflow activity, its mass was estimated to be ${\sim}0.012-0.023M_{\odot}$, suggesting L328-IRS to be a substellar object. However, we leave our identification of L328-IRS as a proto-brown dwarf to be tentative because of various uncertainties especially regarding the mass accretion rate.

  • PDF

진료실과의 소통과 Noritake powder를 이용한 심미보철제작 (Esthetic restoration using Noritake powder through communication with the dental clinic)

  • 황보아
    • 대한심미치과학회지
    • /
    • 제27권2호
    • /
    • pp.105-115
    • /
    • 2018
  • 치과기공사는 구강 모델에 기초하여 보철물을 제작하기 때문에 안모와의 부조화가 되는 경우가 있다. 안모와의 부조화에 기인한 보철물의 실패를 예방하기 위해서는 진료실과 기공소 간의 소통에 기반한 모델 진단, 안면 및 구강사진을 참고하여 제작해야한다. 그리고 치과기공사는 색과 형태에 대한 이해를 위해 자연치 관찰이 필요하며 Kuraray Noritake의 internal stain 및 투명감을 부여해 주는 powder를 이용하면 자연감 있는 보철물을 제작하데 용이하다.

CONCEPT AND MANAGEMENT OF ISTISQĀ' (OEDEMA) IN UNANI SYSTEM OF MEDICINE

  • Khan, Khalid Ali;Zakir, Mohammad;Khan, Shahid Ali;Khan, Rashid Ali
    • 셀메드
    • /
    • 제11권1호
    • /
    • pp.3.1-3.6
    • /
    • 2021
  • Ascites is the accumulation of fluid in the peritoneal cavity, and it is generally allied with liver disease like cirrhosis of the liver. The ascites is commonly associated with liver cirrhosis, malignancy, or cardiovascular disease today. The liver cirrhosis is the most significant cause of ascites in developed countries as per the available data. In the modern medicine system, the treatment includes the restriction of sodium intake, use of diuretics, and paracentesis done in severe cases. There are many side effects of synthetic chemical diuretics, and their long-term use is not recommended. The alternative medicine like Unani system of medicine provides natural diuretics and drugs which also have protective effects on kidney, liver and other internal organs. It is well known in all drug systems that the prognosis is poor in ascites, but the use of Unani herbal medicines can minimize the side effects caused by synthetic chemical diuretics. The natural herbs used for the management of ascites have fewer side effects as compared to synthetic drugs. The natural drugs can be used for longer duration and provide some dietary supplement which improves the quality of life. This review addressed the thorough treatment of ascites by natural diet and medications.

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • 제52권5호
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.