• 제목/요약/키워드: Intermediate moment frame

검색결과 33건 처리시간 0.021초

접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - I 성능평가 (Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation)

  • 문기훈;한상환;하성진
    • 한국지진공학회논문집
    • /
    • 제18권2호
    • /
    • pp.95-103
    • /
    • 2014
  • The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.

깊이 1200mm급 변단면보의 중간모멘트골조용 내진접합부 개발 (Beam-Column Connection with 1200mm Deep Multi-Reduced Taper Beam for Intermediate Moment Frame)

  • 정시화;알미아이유 로벨 원디므;박만우;주영규
    • 대한건축학회논문집:구조계
    • /
    • 제35권4호
    • /
    • pp.135-146
    • /
    • 2019
  • Deep beam has high section modules compared with shallow beam of the same weight. However, deep beam has low rotational capacity and high possibility of brittle failure so it is not possible to apply deep beams with a long span to intermediate moment frames, which should exhibit a ductility of 0.02rad of a story drift angle of steel moment frames. Accordingly, KBC and AISC limit the beam depth for intermediate and special moment frame to 750mm and 920mm respectively. The purpose of this paper is to improve the seismic performance of intermediate moment frame with 1200mm depth beam. In order to enhance vulnerability of plastic deformation capacity of deeper beam, Multi-Reduced Taper Beam(MRTB) shape that thickness of beam flange is reinforced and at the same time some part of the beam flange width is weakened are proposed. Based on concept of multiple plastic hinge, MRTB is intended to satisfy the rotation requirement for intermediate moment frame by dividing total story drift into each hinge and to prevent the collapse of the main members by inducing local buckling and fracture at the plastic hinge location far away from connection. The seismic performance of MRTB is evaluated by cyclic load test with conventional connections type WUF-W, RBS and Haunch. Some of the proposed MRTB connection satisfies connection requirements for intermediate moment frame and shows improved the seismic performance compared to conventional connections.

국내 저층 철골 모멘트골조의 내진설계 (Seismic Design of Low-rise Steel Moment Frames in Korea)

  • 김태완
    • 한국지진공학회논문집
    • /
    • 제15권1호
    • /
    • pp.11-18
    • /
    • 2011
  • 현재 국내 철골 모멘트골조 접합부는 대부분 공장제작으로 품질관리가 잘 이루어져 연성능력이 상당한 수준이다. 문헌에 의하면 국내 접합부는 미국 철강협회에서 철골 중간모멘트골조에 대해 제시한 성능 기준을 충분히 만족하고 있다. 그런데 이전 설계기준인 KBC2005에서는 철골모멘트골조에 연성모멘트골조 하나만을 제공하였으나 현 KBC2009 기준은 보통, 중간, 특수모멘트골조로 다양하게 제공하고 있다. 여기서 국내 접합부 형식을 그대로 사용했을 때 어떤 시스템이 적합한지 조사할 필요성이 있다. 따라서 본 연구에서는 KBC2005의 연성모멘트골조와 KBC2009의 중간모멘트골조의 거동을 비교하여 국내에 적합한 설계 방법을 찾고자 하였다. 연구 결과 기존 연성모멘트골조의 설계 계수를 따르더라도 성능목표를 충분히 만족하는 것으로 나타났다.

FEMA P695를 이용한 국내 저층 철골 중간모멘트골조의 반응수정계수 제안 (Proposition of Response Modification Factor of Low-rise Steel Intermediate Moment Frame in Korea using FEMA P695)

  • 한아름;김태완;유은종
    • 한국지진공학회논문집
    • /
    • 제18권1호
    • /
    • pp.37-43
    • /
    • 2014
  • In current seismic design code, steel moment frames are classified into ordinary, intermediate, and special moment frames. In the case of special moment frames which have large R-factor, economic design is possible by reducing the design lateral force. However, there is difficulty for practical application due to constraints such as strong column-weak beam requirement. This study evaluated if steel intermediate moment frame could maintain enough seismic capacity when the R-factor is increased from 4.5 to 6. As for the analytical models, steel moment frames of 3 and 5 stories were categorized into four performance groups according to seismic design category. Seismic performances of the frames were evaluated through the procedure based on FEMA P695. FEMA P695 utilizes nonlinear static analysis(pushover analysis) and nonlinear dynamic analysis(incremental dynamic analysis, IDA). In order to reflect the characteristics of Korean steel moment frames on the analytical model, the beam-column connection was modeled as weak panel zone where the collapse of panel zone was indirectly considered by checking its ultimate rotational angle after an analysis is done. The analysis result showed that the performance criteria required by FEMA P695 was satisfied when R-factor increased in all the soil conditions except $S_E$.

Seismic response of built-up double-I column in steel moment resisting frame using welded external diaphragm plate

  • Tabebordbar, Amir;Dehghan, Seyed Mehdi;Fathi, Farshid;Najafgholipour, Mohammad Amir
    • Steel and Composite Structures
    • /
    • 제41권5호
    • /
    • pp.747-759
    • /
    • 2021
  • Built-up Double-I (BD-I) columns have been commonly used for mid-rise steel-frame structures in Iran. These columns consist of two hot rolled IPE sections which are connected by two cover plates and fillet welds. Until 2017, BD-I columns were employed in intermediate moment resisting frames (MRF) using welded flange plate (WFP) connections. To evaluate the seismic behavior of the connections, four samples were made and tested based on cyclic loading according to AISC 341-16. It was concluded that typical samples cannot satisfy the seismic provisions related to intermediate MRFs. In contrast, the proposed connections retrofitted with two-part external diaphragms were able to satisfy not only the seismic requirements related to intermediate MRFs but also those related to special MRFs according to AISC. The numerical modeling of these samples was performed using ABAQUS finite element software. This study compared the hysteresis moment-rotation curves, plastic strains, and behavior modes in both experimental samples and numerical models.

5층 철근콘크리트 모멘트-저항골조 구조물의 내진성능 평가 및 공사원가 분석 (Seismic Performance Evaluation and Economic Analysis of 5-Story RC Moment-Resisting Frames)

  • 강석봉;김성대;박의수;오상묵;손기영
    • 한국건축시공학회지
    • /
    • 제15권6호
    • /
    • pp.569-577
    • /
    • 2015
  • 구조물 내진설계에 대한 개념이 사양중심설계에서 성능기반설계로 변화하고 있다. 구조물 목표성능을 직접 부여하여 설계하는 성능기반설계를 위해서는 구조물 실제 거동을 정확히 예측하기 위한 비탄성 구조해석이 필요하다. 이에 본 연구에서는 KBC2009 기준으로 설계한 5층 철근콘크리트 모멘트-저항골조 시스템 구조물을 대상으로 푸쉬오버해석을 수행하여 내진성능을 평가한 후 직접공사비를 산출하여 경제성을 분석하였다. 분석 결과 보통 및 중간모멘트골조는 요구성능설계기준을 만족하며 직접공사비 또한 유사한 것으로 평가되었다. 하지만, 강 기둥-약 보 기준이 적용되는 특수모멘트골조는 요구성능설계기준을 만족하나 다른 골조시스템 보다 비경제적인 것으로 평가되었다. 따라서 IBC2012에서는 내진설계범주 D 중간모멘트골조 적용을 제한하고 있지만 5층 철근콘크리트 모멘트-저항골조 구조물의 경우, 특수모멘트골조 보다 보통 및 중간모멘트골조로 설계하는 것이 합리적이라고 판단된다.

Numerical study on the post-earthquake fire behavior of intermediate steel moment frames

  • Parvizizadeh, Shayan;Kazemi, Mohammad Taghi
    • Earthquakes and Structures
    • /
    • 제22권2호
    • /
    • pp.137-145
    • /
    • 2022
  • As steel is highly sensitive to temperature variations, fire exposure is more destructive in the case of steel structures in comparison to the concrete ones. The performance of an intermediate three-story steel moment frame with 4 spans was studied under the service load, thermal load and post-earthquake fire in this paper. Also, the effects of passive fire-protection materials such as ordinary cement-based and fire-retardant coatings were investigated. To model and analyze the structure; Abaqus software is utilized. In order to apply the earthquake effect, the push-over analysis method is employed. Changes in the stories deflection, endurance time and growth of nonlinear regions due to losses in the steel stiffness and strength, are among the issues considered in this study. As an interesting finding, the beams protected by ordinary cement-based coating could sustain the fire exposure at least for 30 minutes in all cases. The mentioned time is increased by employing a new fire-retardant protection, which could prevent significant loss in the structure resistance against fire, even after 60 minutes of exposure to fire.

다양한 높이를 가진 철골 중간모멘트골조의 내진성능평가 (Seismic Performance Evaluation of Steel Intermediate Moment Frames with Different Heights)

  • 김동휘;박유진;한상환
    • 한국전산구조공학회논문집
    • /
    • 제27권4호
    • /
    • pp.215-222
    • /
    • 2014
  • 본 연구의 목적은 다양한 높이에 따른 철골 중간모멘트골조의 내진성능을 평가하는 것이다. 구조물의 내진성능은 ATC-63에서 제안한 방법론에 따라 평가되었다. 3층, 6층, 9층, 12층 중간모멘트골조의 설계는 KBC 2009에 따라 수행하였다. 접합부의 모델링은 철골 중간모멘트골조에서 요구되는 회전성능인 0.02rad을 만족하도록 모델링하였다. 연구를 수행한 결과, 구조물의 붕괴확률은 높이가 증가함에 따라 증가하였다. 특히 9층과 12층 구조물은 ATC-63에서 제시한 요구조건을 만족하지 못하였다.

축소모델실험에 의한 철근콘크리트 3층 보통모멘트골조의 구조 성능 평가 (Seismic Performance Evaluation of 3 Story OMRCF Based on Scaled Model Testing)

  • 한상환;권건업
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.673-678
    • /
    • 2005
  • ACI 318(1999) 규준에서는 모멘트골조를 특수모멘트골조, 중간모멘트골조, 보통모멘트골조의 3가지로 구분하고 있다. 이중 중 약 지진 지역에서는 대부분의 구조물이 보통모멘트골조로 설계되고 있다. 이러한 보통모멘트골조는 현행 규준에서 가장 엄격하지 않은 상세와 요구사항이 적용되는 골조 형식이다 본 연구는 중력하중으로만 설계되고 ACI 318(1999) 기준의 보통모멘트골조의 상세만을 가지는 3층의 사무소 건물의 내진 성능 평가를 그 목표로 한다 실험적 연구를 위하여 1/3 축소 모델을 제작하여 준정적 실험을 실시하였다. 보통모멘트골조의 전체적인 거동은 갑작스러운 강도의 저감 없이 안정적인 거동을 하였다 실험결과, 중력하중으로만 설계된 3층의 사무소건물은 UBC 1997 규준의 지진 지역 1, 2A, 2B에서의 요구하는 설계 밑면전단력보다 더 큰 횡력 저항 능력을 가지고 있는 것으로 나타났다.

Effect of connection rotation capacities on seismic performance of IMF systems

  • Han, Sang Whan;Moon, Ki-Hoon;Ha, Sung Jin
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.73-89
    • /
    • 2016
  • The seismic performance of moment frames could vary according to the rotation capacity of their connections. The minimum rotation capacity of moment connections for steel intermediate moment frames (IMF) was defined as 0.02 radian in AISC 341-10. This study evaluated the seismic performance of IMF frames with connections having a rotation capacity of 0.02 radian. For this purpose, thirty IMFs were designed according to current seismic design provisions considering different design parameters such as the number of stories, span length, and seismic design categories. The procedure specified in FEMA P695 was used for conducting seismic performance evaluation. It was observed that the rotation capacity of 0.02 radian could not guarantee the satisfactory seismic performance of IMFs. This study also conducted seismic performance evaluation for IMFs with connections having the rotation capacity of 3% and ductile connections for proposing the minimum rotation capacity of IMF connections.