• 제목/요약/키워드: Interior finish materials

검색결과 60건 처리시간 0.03초

지속가능한 건축디자인을 위한 기초방안에 관한 고찰 - 미국 미네소타 주 친환경사례의 실내 건축자재를 중심으로 - (A Study on the Basic Solution for Sustainable Buildings - Focused on the Interior Materials of Eco-Buildings in Minnesota, USA)

  • 천진희
    • 한국실내디자인학회논문집
    • /
    • 제15권2호
    • /
    • pp.174-182
    • /
    • 2006
  • This study is focused on interior materials and wastes among other diverse environmental strategies for sustainable construction. The case study was carried out by using MSDG, mainly utilized in evaluating performance of sustainable constructions in Minnesota, the US, as an evaluation tool, in order to analyze American practices. In this study, a field inspection was conducted to 6 Minnesota cases, following a preliminary examination through literature study and portal site search, and then, constructive reports, interviews with people in charge, and empirical data including photos were added to the basic data provided by MSDG and MOEA As a result, it turned out *that sustainable materials were mainly used even in newly constructed buildings and wastes were properly managed in an environment-friendly, economical, and ethical manner, *that life cycle assessment showed reduction in some constructive costs even when the basic costs were high, *that some recycled finish materials were widely used in diverse areas, *that minimum consumption of raw materials, minimum environmental damage by materials, minimum effect of materials on IAQ were found in the examined cases, and *that many attempts were made to minimize resource consumption and constructive wastes from diverse perspectives.

피톤치드를 함유한 기능성 시멘트 경화체의 특성에 관한 연구 (Study on the Properties of Functional Cement Matrix using Phytoncide)

  • 김현성;김선아;박선규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.29-30
    • /
    • 2018
  • The development of the industry has increased the indoor living time of modern people. Therefore, indoor pollution is attracting attention as a social issue. One of the indoor air pollution is formaldehyde. Formaldehyde has been classified as a first-level carcinogen by international cancer research organizations. Formaldehyde has been used to protect products such as construction materials and finish materials, and being diffused in the interior construction process. In this study, we used phytoncide with cement matrix to reduce formaldehyde, an indoor environmental contaminant. The strengths was increased slightly and formaldehyde showed a reduction effect over time.

  • PDF

신축 아파트의 실내 마감재 변경 및 시공단계별 휘발성유기화합물 발생 특성 (Characteristics of VOCs Emission According Interior Finish Materials and Working Phases of New Apartments)

  • 방승기;조우진;손장열
    • 설비공학논문집
    • /
    • 제18권6호
    • /
    • pp.486-492
    • /
    • 2006
  • In this research, IAQ is measured to evaluate the emission performance of VOCs in three new apartment houses finished by totally EFMs (Environmental Friendly Material), partially installed EFMs and general materials. Among various VOCs, Target pollutants for the IAQ measurement are benzene, ethylbenzene, toluene, xylene, 1,4-Dichlorobenzene and formaldehyde. The measurement is conducted one day after each interior finishing material is worked over by construction schedule. The result of this research concluded that (1) Except toluene, the concentration levels of each pollutant did not exceed the national IAQ standards in all test residences, (2) As the interior finishing work schedule, A toluene level peaked when the furniture installing was ended. (3) The toluene concentration level of the house installed general interior materials as the non-EFMs furniture was one and half higher than other houses. Consequently, installing. the furniture made by EFMs is one of effective methods to improve the IAQ for new apartment houses.

바이오미미크리 특성이 적용된 신재료 가공방법 연구 (A Study on Processing Methods of New Materials Applied to Biomimicry Characteristics)

  • 지주연;서지은
    • 한국실내디자인학회논문집
    • /
    • 제22권5호
    • /
    • pp.367-375
    • /
    • 2013
  • Using the 'New material' concept has recently been introduced into the natural characteristics. In the course of such a, Janine M. Benyus has proposed to mimic the characteristics of natural ecosystems to mention the concept of Biomimicry. Process made engineered using technical elements for representing the material properties of Biomimicry such will be acting importantly, This study intends to analyze how new materials applied to 'Biomimicry' characteristics are processed in space. The results were as follows : 1) Processing methods of new materials resulted as 'Forming', 'Surface treatment', 'Bonding', 'Inserting'. These four were divided and analyzed into 'Form', 'System', 'Adaptation'. As a result of this analysis, such significances were shown as 'Forming/Surface treatment/Bonding' in 'Form', 'Bonding' in 'System' and 'Adaptation'. 2) 'Bonding' applied to 'System' of new material can be recycled to be combined with other materials through the existing adhesive material, and present as a solution of 'Sustainable development'. 3) 'Bonding' applied to 'Adaptation' of new material is to impart the ability to react to the environment through the joint, but is characteristic, at this time, using digital and other field technology. It appeared primarily that it can be known to meet the social trends and convergence between fields. Thus, as the finish that are friendly to the environment from the interior design, the results of the study are expected to be utilized in the study of new materials guidelines.

가변형 주택에서 실내공간요소의 가변방식 유형분석 (Typological Approach to the Flexible System of Interior Element for Flexible Housing)

  • 모정현;이연숙
    • 한국실내디자인학회논문집
    • /
    • 제14권1호
    • /
    • pp.64-72
    • /
    • 2005
  • The purpose of this study was to analyze the flexible system in a typological way that develops and promotes the various methods of flexible system. The main method of this study was literature review and content analysis on various flexible systems and a case study of flexible housing. The flexible system in this typological analysis was classified into two categories: 'Elements of Flexibility' and 'Variation'. The category of Flexibility Elements was categorized into 'Primary Elements'(e.g., walls, floors, and ceilings),'Secondary Elements'(e.g., doors, windows, and furniture), and 'Tertiary Elements'(e.g., lighting, hues and finishing materials). Variation Effect was classified into 'Visual Variation', 'AppBicative Variation', and 'Layout Variation'. Also, Variation could be classified into 'Finish-centered', 'Application-centered', and 'Layout-centered' The flexible system developed in this study is a basis for further concrete flexible methods.

A Room-Corner Fire Model을 적용한 건축내장재의 화재확산 특성 평가(1)

  • 김운형
    • 방재기술
    • /
    • 통권24호
    • /
    • pp.32-39
    • /
    • 1998
  • A room-corner fire scenario of ISO 9705 with flame spread model developed by Quintiere is applied to the interior finish materials to show the sensitivity of properties derived from AST, E-1321 and ASTM E-1354 is investigated and various range of thermal properties by the author were analyzed in the model. There are including flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The time for total energy release rate to reach 1MW is examined. Though some areas are neede for improvements, The model appears to predict good results with all the range of input properties and could be

  • PDF

APPLICATIONS OF A MODEL TO COMPARE AFLAME SPREAD AND BEAT RELEASE PROPERTIES OF INFERIOR FINISH MATERIALS IN A COMPARTMENT

  • Kim, Woon-Hyung;James G. Quintiere
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.193-200
    • /
    • 1997
  • Flame spread and heat release properties and incident heat flux of interior materials subject to an igniter heat flux in a compartment are investigated and compared by using computer model. A comer fire ignition source is maintained for 10 minutes at 100 kw and subsequently increased to 300kw. In executing the model, base-line material properties are selected and one is changed for each run. Also 4 different igniter heat flux conditions and examined. Results are compared for the 12 different materials tested by the ISO Room Comer Test (9705). The time for total energy release rate to reach 1MW is examined. The parameters considered include flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The model can show the importance of each property in causing fire growth on interior Hnish materials in a compartment. The effect of ignitor heat flux and material property effects were demonstrated by using dimensionless parameters a, b and Tb. Results show that for b greater than about zero, flashover time in the ISO Room-Corner test is principally proportional to ignition time and nothing more.

  • PDF

마감재 및 환기를 고려한 공동주택 실내 라돈 농도의 비정상 해석 (Unsteady Analysis of Indoor Radon in Apartment Buildings Considering Finishing Materials and Ventilation)

  • 조현;방승기
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.24-31
    • /
    • 2019
  • In this paper, we simulated a new apartment building by using radon emission test values from various building materials used as interior finishing materials. The simulations evaluated the radon concentration in the room according to the radon emissions and the ventilations for each type of finishing material (gypsum board, stone, tile and concrete). Overall concrete finish simulation case showed the highest concentration than the case using other materials due to the effect of wall area at the center of each room and the mean radon concentration at 1.5 m above the floor was slightly lower than the mean value at each center. In the case of the porch, pantry and bathroom, the radon concentration was high even when the same materials were used as in the other rooms.

페르소나 특성을 반영한 데이케어센터 실내환경디자인 개선방안 도출 - 종로 구립 실버센터의 사례를 중심으로 - (Extraction of An Improvement Plan of Day Care Center's Interior Environment Design Reflecting Persona Characteristics -The case of Jounno Ward Silver Center-)

  • 이진우;남경숙
    • 한국실내디자인학회논문집
    • /
    • 제24권1호
    • /
    • pp.43-53
    • /
    • 2015
  • As part of alternative of elderly problems in the future super-aging society, this study aims to extract an improvement plan of interior environment design of Seoul-type day care centers to expand in future by observing day care centers as medical and healing environments, from the perspective of user experience. For this study, after selecting major activity areas of representative cases of Seoul-type day care centers, user behaviors in the space were observed and 4 seniors of baby-boom generation who are potential uses were chosen as personas by reflecting characteristics of healthy elderly, physical aging, mental aging and infirm elderly, from the perspective of user experience. Based on previous studies on healing environments, these characteristics and demands of personas were classified into environmental aspects, physical aspects and mental aspects to extract an improvement plan. The study results are as follows. First, interior environment design reflecting persona characteristics helps the elderly adapt to the environment and provides a comfortable environment like home for stability, treatment and recovery of memory. Second, interior environment design reflecting persona characteristics helps psychological healing through light entering the large windows and natural environment elements. Third, for interior environment design reflecting persona characteristics, finish materials with bright and soft colors should be used to change the images of facilities positively. Fourth, spatial composition should be remedied through division of space and built-in furniture depending on the needs of users for loitering of extra time and programs.

교회공간 예배실의 위치적 기능에 따른 마감재 적용 연구 (A Study on the Application of Finishing Materials According to the Locational Function of the Chapel in Church Space)

  • 여미;이창노
    • 한국실내디자인학회논문집
    • /
    • 제24권1호
    • /
    • pp.178-188
    • /
    • 2015
  • This study has the main objective of being of help as a reference data for the application of the finishing materials when designing the interior of the chapel of the church space through analysis of the finishing materials against the chapels of church space which has complex function. As precedent studies for this, the composition of the function and concept of the church space was surveyed and the complex function of the church space was surveyed. The theoretical surveyed was performed according to the casual composition, behavior of the community and role and location of the duties of the church members. The case objects were 10 chapels constructed by 5 professional interior design companies. The content of the analysis was the finishing materials in the chapels and their application characteristics. The detailed considerations to be referred to when designing the interior of the chapels of church space in the future were proposed. The analysis result of the application of the finishing materials according to the locational function of the chapels of church space can be explained as follows. First, the platform area was the characteristic of applying finishing materials which induce visual immersion. As for the floor materials in the platform, in order to minimize the floor sound and vibration phenomenon occurring during movements, noise insulation and dust protection rubber sheet was place and on top of it the floor or the carpet was placed. Second, the Choir area had the difficult problem of having to consider the appropriate sound absorption occurring due to the proliferation of sound and performance of classical instruments at the same time. However, in the case, this problem was solved through the sculptures of convex shape. Third, since the scheelite is a space where many people move around, the finishing material which absorbs sound was mainly used. Fourth, the entrance area was composed of thick wall materials compared to other walls, and the sound absorption character was most significantly considered when applying the finishing material. Fifth, the broadcasting room was composed either in independent type or an open type and performed its function and the main finishing materials was transparent glass which was highest use frequency.