• 제목/요약/키워드: Interference value

Search Result 407, Processing Time 0.028 seconds

Optical-fiber Electronic Speckle Pattern Interferometry for Quantitative Measurement of Defects on Aluminum Liners in Composite Pressure Vessels

  • Kim, Seong Jong;Kang, Young June;Choi, Nak-Jung
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.50-56
    • /
    • 2013
  • Optical-fiber electronic speckle pattern interferometry (ESPI) is a non-contact, non-destructive examination technique with the advantages of rapid measurement, high accuracy, and full-field measurement. The optical-fiber ESPI system used in this study was compact and portable with the advantages of easy set-up and signal acquisition. By suitably configuring the optical-fiber ESPI system, producing an image signal in a charge-coupled device camera, and periodically modulating beam phases, we obtained phase information from the speckle pattern using a four-step phase shifting algorithm. Moreover, we compared the actual defect size with that of interference fringes which appeared on a screen after calculating the pixel value according to the distance between the object and the CCD camera. Conventional methods of measuring defects are time-consuming and resource-intensive because the estimated values are relative. However, our simple method could quantitatively estimate the defect length by carrying out numerical analysis for obtaining values on the X-axis in a line profile. The results showed reliable values for average error rates and a decrease in the error rate with increasing defect length or pressure.

Gain characteristics of SQUID-based RF amplifiers depending on device parameters

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Lee, S.K.;Chong, Y.;Oh, S.J.;Semertzidis, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.10-14
    • /
    • 2019
  • Radio-frequency (RF) amplifiers based on direct current (DC) superconducting quantum interference device (SQUID) have low-noise performance for precision physics experiments. Gain curves of SQUID RF amplifiers depend on several parameters of the SQUID and operation conditions. We are developing SQUID RF amplifiers for application to measure very weak RF signals from ultra-low-temperature high-magnetic-field microwave cavity in axion search experiments. In this study, we designed, fabricated and characterized SQUID RF amplifiers with different SQUID parameters, such as number of input coil turn, shunt resistance value of the junction and coupling capacitance in the input coil, and compared the results.

Single Phase Inverter High Frequency Circuit Modeling and Verification for Differential Mode Noise Analysis (차동 노이즈 분석을 위한 단상 인버터 고주파 회로 모델링 및 검증)

  • Shin, Ju-Hyun;Seng, Chhaya;Kim, Woo-Jung;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.176-182
    • /
    • 2021
  • This research proposes a high-frequency circuit that can accurately predict the differential mode noise of single-phase inverters at the circuit design stage. Proposed single-phase inverter high frequency circuit in the work is a form in which harmonic impedance components are added to the basic single-phase inverter circuit configuration. For accurate noise prediction, parasitic components present in each part of the differential noise path were extracted. Impedance was extracted using a network analyzer and Q3D in the measurement range of 150 kHz to 30 MHz. A high-frequency circuit model was completed by applying the measured values. Simulations and experiments were conducted to confirm the validity of the high-frequency circuit. As a result, we were able to predict the resonance point of the differential mode voltage extracted as an experimental value with a high-frequency circuit model within an approximately 10% error. Through this outcome, we could verify that differential mode noise can be accurately predicted using the proposed model of the high-frequency circuit without a separate test bench for noise measurement.

Association of the Comprehensive Attention Test and the Korean Wechsler Intelligence Scale for Children-Fourth Edition in Children and Adolescents With Attention-Deficit/Hyperactivity Disorder

  • Min-Su Jang;Sang-Keun Chung;Jong-Chul Yang;Jong-Il Park;Joo-Han Kwon;Tae-Won Park
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.34 no.3
    • /
    • pp.181-187
    • /
    • 2023
  • Objectives: This study aimed to investigate the correlation between the Comprehensive Attention Test, Korean-Wechsler Intelligence Scale for Children-Fourth Edition, and Attention-Deficit/Hyperactivity Disorder (ADHD) Rating Scale-IV scores in children and adolescents with ADHD. Methods: Fifty-five children and adolescents diagnosed with ADHD and not taking psychiatric medications were included in this retrospective study. A correlation analysis was performed. Results: Although simple visual and auditory selective attention have diagnostic value in traditional continuous performance tests, this study revealed that inhibition-sustained attention and interference-selective attention are also effective in evaluating ADHD. Furthermore, the correlation between the attention and intelligence test scores varied depending on the use of visual or auditory stimuli. Conclusion: The findings of this study contribute to clarifying our understanding of the cognitive characteristics of children and adolescents with ADHD and can be used in future research.

Establishment and application of standard-RSF for trace inorganic matter mass analysis using GD-MS (GD-MS 분석 장비를 활용한 극미량 무기물 질량 분석을 위한 표준RSF 구축 및 응용)

  • Jang, MinKyung;Yang, JaeYeol;Lee, JongHyeon;Yoon, JaeSik
    • Analytical Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.240-246
    • /
    • 2018
  • The present study analyzed standard samples of three types of aluminum matrix certified reference materials (CRM) using GD-MS. Calibration curves were constructed for 13 elements (Mg, Si, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Sn, and Pb), with the slope representing the relative sensitivity factor (RSF). The x- and y-axes of the calibration curve represented ion beam ratio (IBR) and the authenticated value of the standard sample, respectively. In order to evaluate precision and linearity of the calibration curve, RSD and the coefficient of determination were calculated. Curve RSD for every element reflected high precision (within 10 %). For most elements, the coefficient of determination was ${\geq}0.99$, indicating excellent linearity. However, vanadium, nickel, and gallium curves exhibited relatively low linearity (0.90~0.95), likely due to their narrow concentration ranges. Standard RSF was calculated using the slope of the curve generated for three types of CRM. Despite vanadium, nickel, and gallium exhibiting low coefficients of determination, their standard RSF resembled that of the three types of CRM. Therefore, the RSF method may be used for element quantitation. Standard iron matrix samples were analyzed to verify the applicability of the aluminum matrix standard RSF, as well as to calculate the RSD-estimated error of the measured value relative to the actual standard value. Six elements (Al, Si, V, Cr, Mn, and Ni) exhibited an RSD of approximately 30 %, while the RSD of Cu was 77 %. In general, Cu isotopes are subject to interference: $^{63}Cu$ to $^{54}Fe^{2+}-^{36}Ar$ and $^{65}Cu$ to $^{56}Fe-Al^{3+}$ interference. Thus, the influence of these impurities may have contributed to the high RSD value observed for Cu. To reliably identify copper, the resolution should be set at ${\geq}8000$. However, high resolutions are inappropriate for analyzing trace elements, as it lowers ion permeability. In conclusion, quantitation of even relatively low amounts of six elements (Al, Si, V, Cr, Mn, and Ni) is possible using this method.

Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology (환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정)

  • Kang, Suman;Im, Inchul;Lee, Jaeseung;Jang, Eunsung;Lee, Mihyeon;Kwon, Kyungtae;Kim, Changtae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression device is a device by using the Compton scattering reaction and suppress the Compton continuum portion of the spectrum, so can be made more clear analysis of gamma ray peak in the Compton continuum region. Measurements above background occurs or, radioactivity counts of radioactivity concentration value of $^{40}K$ nuclides $^{137}Cs$ and natural radioactivity artificial radioactivity detected from the surface soil sample, unwanted non-target analysis and interference peak who dotted line you know the calibration of the measurement energy is allowed to apply the (Compton suppression) non-suppressed spectrum inhibition spectrum and (Compton Unsuppression) the background to the measured value of the activity concentration value of the standard-ray source is detected relative to the peak of By measuring according to the different distances cause $^{137}Cs$, and comparative analysis of the Monte Carlo simulation, in order to obtain a detection capability for efficient, looking at the Compton inhibitor, as the CSF value increases with increase in the distance, more It was found that the background due to Compton continuum of the measured spectrum suppression mode Compton unrestrained mode can know that the Compton suppression many were made, using a $^{137}Cs$ is reduced.

Distributed Throughput-Maximization Using the Up- and Downlink Duality in Wireless Networks (무선망에서의 상하향 링크 쌍대성 성질을 활용한 분산적 수율 최대화 기법)

  • Park, Jung-Min;Kim, Seong-Lyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.11A
    • /
    • pp.878-891
    • /
    • 2011
  • We consider the throughput-maximization problem for both the up- and downlink in a wireless network with interference channels. For this purpose, we design an iterative and distributive uplink algorithm based on Lagrangian relaxation. Using the uplink power prices and network duality, we achieve throughput-maximization in the dual downlink that has a symmetric channel and an equal power budget compared to the uplink. The network duality we prove here is a generalized version of previous research [10], [11]. Computational tests show that the performance of the up- and downlink throughput for our algorithms is close to the optimal value for the channel orthogonality factor, ${\theta}{\in}$(0.5, 1]. On the other hand, when the channels are slightly orthogonal (${\theta}{\in}$(0, 0.5]), we observe some throughput degradation in the downlink. We have extended our analysis to the real downlink that has a nonsymmetric channel and an unequal power budget compared to the uplink. It is shown that the modified duality-based approach is thoroughly applied to the real downlink. Considering the complexity of the algorithms in [6] and [18], we conclude that these results are quite encouraging in terms of both performance and practical applicability of the generalized duality theorem.

Performance Evaluation of DSE-MMA Blind Equalization Algorithm in QAM System (QAM 시스템에서 DSE-MMA 블라인드 등화 알고리즘의 성능 평가)

  • Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.115-121
    • /
    • 2013
  • This paper related with the DSE-MMA (Dithered Sign-Error MMA) that is the simplification of computational arithmetic number in blind equalization algorithm in order to compensates the intersymbol interference which occurs the passing the nonlinear communication channel in the presence of the band limit and phase distortion. The SE-MMA algorithm has a merit of H/W implementation for the possible to reduction of computational arithmetic number using the 1 bit quantizer in stead of multiplication in the updating the equalizer tap weight. But it degradates the overall blind equalization algorithm performance by the information loss at the quantization process compare to the MMA. The DSE-MMA which implements the dithered signed-error concepts by using the dither signal before qualtization are added to MMA, then the improved SNR performance which represents the roburstness of equalization algorithm are obtained. It has a concurrently compensation capability of the amplitude and phase distortion due to intersymbol interference like as the SE-MMA and MMA algorithm. The paper uses the equalizer output signal, residual isi, MD, MSE learning curve and SER curve for the performance index of blind equalization algorithm, and the computer simulation were performed in order to compare the SE-MMA and DSE-MMA applying the same performance index. As a result of simulation, the DSE-MMA can improving the roburstness and the value of every performance index after steady state than the SE-MMA, and confirmed that the DSE-MMA has slow convergence speed which meaning the reaching the seady state from initial state of adaptive equalization filter.

Channel estimation scheme of terrestrial DTV transmission employing unique-word based SC-FDE (Unique-word 채용한 SC-FDE 기반 지상파 DTV 전송의 채널 추정 기법)

  • Shin, Dong-Chul;Kim, Jae-Kil;Ahn, Jae-Min
    • Journal of Broadcast Engineering
    • /
    • v.16 no.2
    • /
    • pp.207-215
    • /
    • 2011
  • A signal passed through multi-path channel suffers ISI(Inter-Symbol Interference) and severe distortions caused by channel delay spread and noise components at the SC-FDE(Single Carrier with Frequency Domain Equalizer) transmission. Conventional UW(Unique-Word) based SC-FDE iterative channel estimation improves channel estimation performance by smoothing estimated CIR(Channel Impulse Response) of the noise components outside the channel length at time domain and restoring the broken cyclic property through UW reconstruction. In this paper, we propose channel estimation scheme through noise suppression within channel length. To suppress the noise, we estimate noise standard deviation as estimated CIR of the noise components outside the channel length and make criteria of the noise standard deviation gain that doesn't affect the original signal samples. When estimated CIR samples within channel length are less than the criteria value using the noise standard deviation and gain, the noise components are removed. Simulation results show that the proposed channel estimation scheme brings good channel MSE(Mean Square Error) and good BER(Bit Error Rate) performance.

Studies on Crystallographic and Mossbauer Spectra of the LiFe0.9Mn0.1PO4 (LiFe0.9Mn0.1PO4 물질의 결정구조 및 뫼스바우어 분광 연구)

  • Kwon, Woo-Jun;Lee, In-Kyu;Rhee, Chan-Hyuk;Kim, Sam-Jin;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.1
    • /
    • pp.15-18
    • /
    • 2012
  • The olivine structured $LiFe_{0.9}Mn_{0.1}PO_4$ material was prepared by solid state method, and was analyzed by x-ray diffractometer (XRD), superconducting quantum interference devices (SQUID) and Mossbauer spectroscopy. The crystal structure of $LiFe_{0.9}Mn_{0.1}PO_4$ was determined to be orthorhombic (space group: Pnma) by Rietveld refinement method. The value of N$\acute{e}$el temperature ($T_N$) for $LiFe_{0.9}Mn_{0.1}PO_4$ was determined 50 K. The temperature dependence of the magnetization curves showed magnetic phase transition from paramagnetic to antiferromagnetic at $T_N$ by SQUID measurement. M$\ddot{o}$ssbauer spectra of $LiFe_{0.9}Mn_{0.1}PO_4$ showed 2 absorption lines at temperatures above $T_N$ and showed asymmetric 8 absorption lines at temperatures below $T_N$. These spectra occurred due to the magnetic dipole and electric quardrupole interaction caused by strong crystalline field at asymmetric $FeO_6$ octahedral sites.