• 제목/요약/키워드: Interference examination

검색결과 50건 처리시간 0.028초

N-retinylidene-N-retinylethanolamine degradation in human retinal pigment epithelial cells via memantine- and ifenprodil-mediated autophagy

  • Jae Rim Lee;Kwang Won Jeong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제27권5호
    • /
    • pp.449-456
    • /
    • 2023
  • N-methyl-D-aspartate (NMDA) receptors are ionic glutamine receptors involved in brain development and functions such as learning and memory formation. NMDA receptor inhibition is associated with autophagy activation. In this study, we investigated whether the NMDA receptor antagonists, memantine and ifenprodil, induce autophagy in human retinal pigment epithelial cells (ARPE-19) to remove N-retinylidene-N-retinylethanolamine (A2E), an intracellular lipofuscin component. Fluorometric analysis using labeled A2E (A2E-BDP) and confocal microscopic examination revealed that low concentrations of NMDA receptor antagonists, which did not induce cytotoxicity, significantly reduced A2E accumulation in ARPE-19 cells. In addition, memantine and ifenprodil activated autophagy in ARPE-19 cells as measured by microtubule-associated protein 1A/1B-light chain3-II formation and phosphorylated p62 protein levels. Further, to understand the correlation between memantine- and ifenprodil-mediated A2E degradation and autophagy, autophagy-related 5 (ATG5) was depleted using RNA interference. Memantine and ifenprodil failed to degrade A2E in ARPE-19 cells lacking ATG5. Taken together, our study indicates that the NMDA receptor antagonists, memantine and ifenprodil, can remove A2E accumulated in cells via autophagy activation in ARPE-19 cells.

금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교 (Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix))

  • 임홍철;왕준호;노영진;황진호
    • 대한관절경학회지
    • /
    • 제7권2호
    • /
    • pp.206-214
    • /
    • 2003
  • 목적 : 자가 골-슬개건-골을 이용한 관절경적 전방 십자 인대 재건술시 금속성, 흡수성 간섭 나사 및 RIGIDfix를 사용하여 시행한 전방 십자 인대 재건술의 임상 결과를 비교하여 RIGIDfix 의 임상적 유용성과 안정성에 관하여 알아보고자 한다. 대상 및 방법 : 1995년 7월부터 2003년 3월 까지 고려대학교 구로병원을 내원하여 자가 골-슬개건-골을 이용한 관절경적 전방 십자 인대 재건술을 시행받은 133명을 대상으로 하였다. 제1 군은 대퇴터널을 금속성 간섭 나사못을 이용하여 고정한 44명, 제 2군은 흡수성 간 섭나사를 사용한 47명, 제 3군은 RIGIDfix 를 사용한 42명으로 하였다. 세 군 사이의 수술 전 후로 Lysholm score, KT-2000 arthrometer, pivot shift test, anterior drawer test, Lachman test 그리고 방사선학적으로는 터널의 위치 및 크기 증가를 측정하였다. 통계학적으로 SAS 8.2를 이용한 Ducan, Tukey 및 t-test를 사용하여 검증하였다 (p<0.05). 결과 : 이학적 검사상 제 1군은 1례, 제 2군은 4례에서 불안정성을 보여 주었으며, 제 3군의 경우 불안정성을 보여주는 경우는 없었다. Lysholm score는 제1군$\~$3군에서 각 각 수술 전 59.8점, 64.4.점, 61점에서 수술 후 90.1점, 92.3점 92점으로 향상되었으며 차이는 없었다. KT-2000 arthrometer의 경우도 각각 수술 전 평균 $9.20{\pm}11.87 mm$, $10.2{\pm}1.50 mm$, $9.5{\pm}1.53 mm$에서 수술 후 $1.43{\pm}0.87 mm$, $1.62{\pm}0.69 mm$, $2.00{\pm}0.74 mm$ 으로 통계학적 유의성은 없었다 (P=0.478) 일반 방사선상 대퇴 터널의 변화는 흡수성 나사(2군)를 사용한 8례에서 관찰되었으나 이차 자기 공명 촬영상 2군 20례 모두에서 이식물 주변으로의 신호강도 변화를 보여 주었다. 그러나 임상적 결과와의 상관성은 찾을 수 없었다. 결론 : 관절경적 전방 십자 인대 재건술 시 금속성, 흡수성 간섭 나사 및 RIGIDfix 를 이용한 이식건의 고정에 있어서 차이는 없었다. 그러나, 대퇴 터널의 변화에 있어서는 RIGIDfix 군에 비해 금속성 및 흡수성 간섭 나사군에서 더 많이 나타났다. 따라서, 수술 도중 수기의 편함, 시간의 단축과 간섭 나사의 고정 위치, 수술 후 생물학적 반응 및 터널의 이차적 변화 등을 고려할때, RIGIDfix의 사용이 유용하리라 사료되나, 좀 더 많은 추적 기간이 필요하리라 사료된다.

  • PDF

환경수 중 크립토스포리디움 오시스트 및 지아디아 시스트 검출의 정확도 및 회수율 향상을 위한 연구 (Improvement of Validity and Efficiency for Detection of Cryptosporidium Ocysts and Giardia Cysts in Environmental Water Samples)

  • 이목영;조은주;김도연;변승헌;이의광;오세종;안승구
    • 미생물학회지
    • /
    • 제39권1호
    • /
    • pp.27-35
    • /
    • 2003
  • 환경수 중 크립토스포리디움 및 지아디아 분석방법은 현재 어떤 방법도 만족할만한 민감도, 특이도, 재현성을 인정 받지 못하고 있어, 다양한 형태의 정도관리 및 수행도 평가가 요구되고 있다. 본 연구는 1623방법(USEPA :Method 1623)을 사용해 한강 지표수에 대한 크립토스포리디움 및 지아디아 접종시험과 현장시료 동시분석시험에 기초하여, 환경수 중 이들의 존재여부와 농도를 측정함에 있어 분석결과의 정확도 및 신뢰도, 그리고 회수율에 미치는 영향요인을 검토하였다. 1623방법에 의한 결과, 평균적으로 한강 지표수시료에 존재하는 크립토스포 리디움의 46%와 지아디아의 60%를 검출할 수 있는 것으로 나타났으나, 각각의 회수율 범위가 13-73% 및 28-84%로 변이가 매우 커서 실제 환경 중 두 원생동물의 농도를 결정하기 위해서는 반복측정 및 통계학적 인 접 근이 수반되어 야 할 것으로 나타났다. 또한 IMS (immunomagnetic separation)중 산첨가에 의한 해체·분리과정을 1 회 더 반복함으로써 지표수시료에서의 총회수율의 약 10%를 향상시킬 수 있었으며, flow cytometry로 계수·준비된 (오)시스트((oo)cysts)를 정도관리에 사용할 경우 보다 신뢰할만한 결과를 얻을 수 있었다. 형광항체 및 DAPI염색은 현장시료특성 이나 전 처리과정에 따라 동일하지 않은 형광특징을 보인 바, 접종 된 현장시료 정제액에 대한 염색결과도 참조되어야 하며, 환경시료에는 다양한 비특이물질이 함유되어 있어 DAPI (4',6-diamidino-2-phenylindole) 염색 및 DIC(Differential Interference Contrast)에 의한 내부구조 관찰이 최종 동정기준이 되어야할 것으로 나타났다.

사랑니 길이 측정을 통한 파노라마와 CBCT의 정확도 연구 (Study on accuracy of panorama and CBCT through length measurement of wisdom teeth)

  • 정천수;김종일
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.131-136
    • /
    • 2013
  • 치과 방사선 발생장치 중 파노라마는 구강악안면의 넓은 해부학적 구조물을 관찰할 수 있으나, 길이나 각도, 형태의 왜곡이 일어날 수 있다. CBCT는 3차원적 영상진단을 할 수 있으며, 해부학적 구조물 사이의 중첩과 간섭에 의한 오차가 현저히 적은 영상을 얻을 수가 있으나, 시간이 길어 피사체의 움직임에 의해 상의 질이 저하될 수 있고 구강 내에 금속 같은 방사선 불투과성 물체가 존재하면 그 물체를 중심으로 방사상으로 방사선 불투과성 선이 나타날 수 있다. 본 연구에서는 파노라마와 CBCT로 측정된 사랑니 길이와 실제 발치된 치아를 비교하여 치아의 왜곡을 분석함으로써 파노라마와 CBCT의 정확도를 분석하고, 치과 치료시 해부학적으로 유용한 정보를 얻고자 한다. 실험결과 파노라마와 Digital Vernier Caliper의 오차는 크게는 110.7%, 작게는 103.9%로 평균적으로 파노라마가 평균 7.3%로 확대됨을 알 수 있었다. CBCT와 Digital Vernier Caliper에서 측정된 사랑니의 길이는 오차범위 1.3%로 나타났고, 파노라마와 Digital Vernier Caliper에서 측정된 사랑니의 길이는 오차범위 7.3%를 나타냄으로써 CBCT가 파노라마보다 약 6% 정확한 영상을 나타냄을 알 수 있었다. CBCT가 파노라마보다 정확한 영상을 나타냄을 확인할 수 있었지만 CBCT는 파노라마보다 검사비용이 비싸고 피폭선량 또한 많아서 검사 시 적절한 방법을 찾아야 할 것으로 사료된다.

단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교 (A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.1003-1011
    • /
    • 2020
  • 본 연구는 듀얼 에너지 CT를 사용하여 금속인공물을 감소시키는 기법을 적용함에 있어 단일 선원과 이중 선원간의 영상 차이를 비교 평가하고자 한다. 단일 선원 장치로는 Discovery CT 256(GE, USA), 이중 선원 장치로는 Somatom Definition Flash(Siemens Health Care, Forchheim, Germany)를 이용하였다. 자체 제작한 팬텀(의료용 Titanium Screw를 삽입한 돼지다리)을 이중에너지 CT를 이용하여 동일 조건하에 선량을 변화시키며 영상을 얻은 후 정량적, 정성적 평가 하였다. 평가 방법으로는 뼈 주변, 조직 주변으로 나누고 금속삽입물로 인해 발생한 금속인공물(선속경화, 산란, 줄무늬)에 대하여 SNR을 측정하여 비교 분석하였다. 단일 선원 장치와 이중 선원 장치 간 금속 인공물 감소기법에는 영상의 차이가 있었다. 단일 선원 장치에서는 금속삽입물에 의한 선속경화 인공물이 이중 선원 장치에서 얻은 영상보다 많은 감소를 보이며 인공물의 방해 없이 주변 조직부가 잘 관찰 되었다. 이중 선원 장치에서는 금속삽입물에 의한 산란과 줄무늬 인공물이 단일 선원 장치에서 보다 많은 감소를 보이며 금속삽입물을 둘러싼 인접 조직들의 신호가 감소 없이 잘 관찰 되었다. 환자를 검사 시 보고자 하는 부위가 금속삽입물에 인접한 주변 조직이냐, 금속삽입물을 감싸는 전체적 조직이냐에 따라 단일 선원 장치와 이중 선원 장치를 구분하여 검사가 행해진다면 진단적으로 도움이 되는 영상을 획득할 수 있을 것으로 생각된다.

EM Radioautographic Techniques에 관(關)한 연구(硏究) - Cork 방법(方法) - (An Improved Method for EM Radioautographic Techniques using Cork)

  • 김명국
    • Applied Microscopy
    • /
    • 제10권1_2호
    • /
    • pp.7-17
    • /
    • 1980
  • Electron microscope radioautography introduced by Liquier-Milward (1956) is now used routinely in many laboratories. Most of the technical difficulties in specimen preparation have been overcome. This method is modified from loop method for improvement of EM radioautographic techniques. The advantages of this method are: 1. the use of single specimens on small corks and of a large wire loop, allows the experimenter to avoid the blemishes in the membrane; 2. the surfactant dioctyl sodium sulphosuccinate is added to diluted ILford L4, thus greatly prolonging the period of time over which good emulsion layers can be made; 3. corks can be handled in perspex holder which allows about 20 specimens to be developed simultaneously. The steps of the method comprise: 1. Cut ribbons of ultrathin sections of silver interference colour 2. Pick them up on formvar-coated 200 mesh grids 3. Prestaining of tissues 4. Coat the specimens with a thin layer of carbon by evaporation (30-60A) 5. Mount the specimens on corks (about 1cm apical diameter) using double-sided scotch tape 6. Emulsion coating; a. Take a 250m1 beaker, place it on the pan of a sliding weight balance and weigh it. Add 10 grams extra to the beam. Add pieces of ILford L4 emulsion to the beaker until the balance is swinging freely. Add the 20ml of distilled water that was previously measured out. b. Surfactant dioctyl sodium sulphosuccinate is added to diluted ILford L4. 7. Prepare a series of membranes of gelled emulsion with the wire loop and apply one to each cork-borne specimen. 8. Put the specimens away to expose by pushing the corks into short length of PVC tubing, each tube having a small hole in the side 9. Place the tubes in small boxes together with silica gel. 10. Exposure 11. Developer - Kodak Microdol X for 3 minutes 12. Fixer - A perspex holder can be manufactured which allows 20 specimens to be developed simultaneously. 12. Fixer - 30% sodium thiosulfate for 10 minutes 13. Examination with Siemens Elmiskop 1A electron microscope

  • PDF

측두하악장애에서 교합요인과 생활변화의 영향 (Effects of Occlusal Factors and Life Event Changes on Temporomandibular Disorders)

  • You-Me Lee;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • 제19권2호
    • /
    • pp.181-192
    • /
    • 1994
  • There have been many different theories on the etiology of temporomandibular disorders(TMDs). The objective of the study was to investigate the effects of occlusal fctors and recent life event changes as prediposing fctor on the development of temporomandibjlar disorders. To evaluate the above predisposing factor, the author used T-scan system(Tekscan Co. U.S.A.) for quantitative occlusal analysis, clinical examination for occlusal state and Social Readjustment Rating Scale(SRRS) for recent life event change units (LCU). 63 patients with TMDs and 57 patients with malocclusion presented at Wonkwang University Dental Hospital participated in this study. The subjects were grouped by Angle's classification and presence of absence of TMDs and parafunctional oral habits. Data gained with regard to contact number, contact force, contact time, occlusal state(number of total teeth and occluding teeth, overjet, overbite) and occlusal interferences (protrusive posterior contact, nonworking side interference, and RCP-ICP slide) and recent life event changes. The data were processed and analysed by SAS statistical package program, The results of this study were as follows : 1. There were no significant differences on both quantitative occlusal contact analysis and occlusal state between TMDs group and Angle's malocclusion group. Also, there were no differences among the Angle's classifications. But amount of overjet in TMDs group were more greater than that of malocclusion group. 2. There was no difference on protrusive posterior contact, and balancing contact between TMDs group and Angle's malocclusion group. Premature contact was more frequent in malocclusion group, but RCP-ICP slide was more frequent in TMDs group. And RCP-ICP slide was more freqent in Angle's class II malocclusion than Angle's I or III malocclusion. 3. Life changes units in TMDs group were higher than those in malocclusion group. And recent life change units in group with parafunctional oral habit were higher than those in group without parafunctional oral habits. Clenching was the most common habit among parafunctional oral habits.

  • PDF

고등학교 기하와 벡터 과목에서 풀이과정 서술의 오류 분석 (An Analysis of Errors in Describing Solving Process for High School Geometry and Vectors)

  • 황재우;부덕훈
    • 한국수학교육학회지시리즈A:수학교육
    • /
    • 제56권1호
    • /
    • pp.63-80
    • /
    • 2017
  • By analysing the examination papers from third grade high school students, we classified the errors occurred in the problem solving process of high school 'Geometry and Vectors' into several types. There are five main types - (A)Insufficient Content Knowledge, (B)Wrong Method, (C)Logical Invalidity, (D)Unskilled Expression and (E)Interference.. Type A and B lead to an incorrect answer, and type C and D cannot be distinguished by multiple-choice or closed answer questions. Some of these types are classified into subtypes - (B1)Incompletion, (B2)Omitted Condition, (B3)Incorrect Calculation, (C1)Non-reasoning, (C2)Insufficient Reasoning, (C3)Illogical Process, (D1)Arbitrary Symbol, (D2)Using a Character Without Explanation, (D3) Visual Dependence, (D4)Symbol Incorrectly Used, (D5)Ambiguous Expression. Based on the these types of errors, answers of each problem was analysed in detail, and proper ways to correct or prevent these errors were suggested case by case. When problems that were used in the periodical test were given again in descriptive forms, 67% of the students tried to answer, and 14% described flawlessly, despite that the percentage of correct answers were higher than 40% when given in multiple-choice form. 34% of the students who tried to answer have failed to have logical validity. 37% of the students who tried to answer didn't have enough skill to express. In lessons on curves of secondary degree, teachers should be aware of several issues. Students are easily confused between 'focus' and 'vertex', and between 'components of a vector' and 'coordinates of a point'. Students often use an undefined expression when mentioning a parallel translation. When using a character, students have to make sure to define it precisely, to prevent the students from making errors and to make them express in correct ways.

용접조립 각형 CFT 기둥-보 외다이아프램 접합부의 구조 거동 (Structural Behavior of Welded Built-up Square CFT Column to Beam Connections with External Diaphragm)

  • 이성희;김영호;최성모
    • 한국강구조학회 논문집
    • /
    • 제28권2호
    • /
    • pp.75-83
    • /
    • 2016
  • 기존 콘크리트충전 각형강관(CFT) 구조에 사용하는 각형강관은 4개의 판을 용접하여 제작하는 박스칼럼이 일반적이다. 그러나 이러한 강관은 제작효율이 저하되며, 또한 기둥-보 접합부에는 내측 다이아프램과 관통 다이아프램을 용접하는데 특수한 용접기술이 필요하다. 따라서, 얇은 강판을 절곡하는 방식으로 응력집중 위치의 용접을 피하고, 단면효율이 극대화된 내부앵커 돌출형의 용접조립 각형강관을 개발하게 되었다. 용접조립 각형강관은 강관내부에 스티프너가 설치되어 내측 다이아프램과 관통 다이아프램과 간섭이 발생하게 되므로 본 연구에서는 용접조립 각형CFT 기둥-보 접합부로 외다이아프램형식을 채택하고 외다이아프램의 설계식을 제안하였으며, 기둥-보 접합부의 거동을 파악하기 위해 실대형 4개 실험체를 제작하여 구조거동 및 내력을 분석하였다.

삼차신경통과 반측안면경련에서 CISS 영상의 진단적 유용성 (Diagnostic Usefulness of CISS Image in Preoperative Evaluation of Trigeminal Neuralgia and Hemifacial Spasm)

  • 이동훈;이상원;최창화
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권2호
    • /
    • pp.186-193
    • /
    • 2001
  • Objectives : Trigeminal neuralgia and hemifacial spasm are caused by vascular compression of the REZ(root entry or exit zone) of the 5th and the 7th cranial nerve. Preoperative detection of neurovascular compression is essential for accurate diagnosis, appropriate treatment, and the good operative results. Three dimensional Fourier Transformation-Constructive Interference in Steady State(3DFT-CISS) images are known to give good contrast between CSF, nerve, and vessels. We applied a 3DFT-CISS imaging technique for the preoperative evaluation of patients with these diseases and estimated the diagnostic accuracy and usefulness of this study. Methods : A series of 71 patients with trigeminal neuralgia and hemifacial spasm were treated by microvascular decompression. Among them 34 patients with trigeminal neuralgia and 24 patients with hemifacial spasm had preoperative CISS images. We compared the radiologic finding with the operative finding, and analysed the diagnostic usefulness of 3DFT-CISS imaging. Results : The sensitivity of CISS images of detecting the neurovascular compression was 90.3% in trigeminal neuralgia and 100% in hemifacial spasm. There were one false-positive and three false-negative cases in trigeminal neuralgia, and one false-positive case in hemifacial spasm. The accuracy in diagnosing the causative vessel was 73.5% in trigeminal neuralgia and 83.3% in hemifacial spasm. Conclusion : CISS image is very useful diagnostic tool for preoperative evaluation of neurovascular compression in patients with trigeminal neuralgia and hemifacial spasm. No additional neuroradiologic examination other than CISS image and MRA is needed for preoperative evaluation of patients with trigeminal neuralgia and hemifacial spasm.

  • PDF