• Title/Summary/Keyword: Interference detection

Search Result 718, Processing Time 0.025 seconds

Ultraviolet Light Sensor Based on an Azobenzene-polymer-capped Optical-fiber End

  • Cho, Hee-Taek;Seo, Gyeong-Seo;Lim, Ok-Rak;Shin, Woojin;Jang, Hee-Jin;Ahn, Tae-Jung
    • Current Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.303-307
    • /
    • 2018
  • We propose a simple ultraviolet (UV) sensor consisting of a conventional single-mode optical fiber capped with an azobenzene-moiety-containing polymer. The UV light changes the dimensions of the azobenzene polymer, as well as the refractive index of the material. Incident light with a wavelength of 1550 nm was reflected at the fiber/polymer and polymer/air interfaces, and interference of the reflected beams resulted in spectral interference that shifted the wavelength by 0.78 nm at a UV input power of $2.5mW/cm^2$. The UV sensor's response to wavelength is nonlinear and stable. The response speed of the sensor is limited by detection noise, which can be improved by modifying the insertion loss of the UV sensor and the signal-to-noise ratio of the detection system. The proposed compact UV sensor is easy to fabricate, is not susceptible to electromagnetic interference, and only reacts to UV light.

A Study of the characteristics of NOx measurement and analysis methods of the SCR system for ships (선박용 SCR 시스템 NOx 측정 및 분석 방식의 특성 연구)

  • Kim, Sung-Yoon;Lee, Young-Ho;Kim, Min;Park, Sam-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.387-392
    • /
    • 2015
  • A method for measuring and analyzing the $NO_x$ in ships is described in $NO_x$ Technical Code 2008. The analysis device, as required by the Code, has been to use a Chemi-luminescence detection method or Heated Chemi-luminescence detection. on the other hand, selective catalytic reduction using $NH_3$ as a reducing agent has an interference effect on the analyzer, and causes measurement error. In this study, the Chemi-luminescence detection method was examined according to how it affects the concentration of $O_2$, CO, $SO_2$, $NH_3$. Fourier transform infrared spectrometry analysis equipment and measurement methods were compared. In order to confirm the effect of the physical interference of the measuring device, it was confirmed by decomposing a measuring device. Consequently, white precipitate and moisture were generated inside the chemiluminescence detection system and I found that affecting interference. The influence of interference highlights the need to consider the minimized $NO_x$ measurement method.

Adaptive Subtraction Method for Removing Variable Powerline Interference of ECG (ECG 신호의 가변적인 전력선 잡음 제거를 위한 적응형 차감기법)

  • Jeon, Hong-Kyu;Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.447-454
    • /
    • 2011
  • Power-line interference(PLI) can distort certain regions in analysing the ECG signal. In particular, the regions such as P and R wave that are important element in diagnosing with arrhythmia is expressed as different type of noise according to the case whether power-line frequency is multiples of sampling frequency and or not. Noise characteristics is also divided into linearity and non-linearity. In this paper, adaptive subtraction method for removing variable PLI of ECG signal is proposed. We classify the multiple relationship between power line and sampling frequency as Multiple and Non-multiple. PLI of Linear segment is extracted through moving average filter, PLI of non-linear segment is extracted through the interference component that is extracted in the linear segment and stored in the temporary buffer. The performance of P wave and R wave detection is evaluated by using 119 data record of MIT-BIH arrhythmia database. The achieved scores indicate P wave detection rate of 97.91%, R wave detection rate of 96.66% and P wave detection rate of 99.01%, R wave detection rate of 97.93% accuracy respectively for Notch filter and proposed subtraction method.

Analytical BER Expression of the Optimal Single User Detection of a BPSK Signal in the Presence of a Gaussian CCI (가우시안 동일 채널 간섭하에서 BPSK 신호의 최적 단일 사용자 검출의 정확한 BER 수식)

  • Chung, Kyuhyuk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.9
    • /
    • pp.491-496
    • /
    • 2014
  • We derive an analytical expression for the bit-error rate (ber) of optimal single user detection (osud) of a binary phase-shift keying (bpsk) signal corrupted by a gaussian cochannel interferer (cci). the channel capacity is also calculated to investigate the ber performance.

Performance of Turbo Coded MC-CDMA with Iterative Multiuser Detection and Decoding in a Nonlinear Fading Channel

  • Ghosh C.;Gangopadhyay R.
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.3
    • /
    • pp.17-23
    • /
    • 2003
  • Turbo decoding in combination with detection strategy for Multi Access Interference (MAI) cancellation has been shown to be very effective for MC-CDMA system in Rayleigh multi-path fading environment. This paper reports new simulation results on the efficacy of joint decoding and detection for MC-CDMA in nonlinear and fading channel.

  • PDF

H.264/AVC Video Quality Improvement by Improved Interference Cancellation Ordering in Multiple Antenna Systems (다중안테나 시스템의 향상된 간섭제거 순서화를 통한 H.264/AVC 비디오 품질향상)

  • Bak, SangHyun;Kim, Jaekwon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.2
    • /
    • pp.50-57
    • /
    • 2010
  • In this paper, we address H.264/AVC video transmission using multiple antennaed phycical layer. When multiple antennas are used, the signals from the other antennas are interferences from the perspective of a target antenna, resulting in lowered video quality. In an effort to improve the video quality, in this paper, we propose a novel detection ordering scheme. We conduct computer simulations to show the efficacy of the proposed scheme.

  • PDF

Determination of Rare Earth Elements Abundance in Alkaline Rocks by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) (ICP-MS를 이용한 알칼리암의 희토류원소 정량분석)

  • Hur, Soon-Do;Lee, Jong-Ik;Lee, Mi-Jung;Kim, Yea-Dong
    • Ocean and Polar Research
    • /
    • v.25 no.1
    • /
    • pp.53-62
    • /
    • 2003
  • Inductively coupled plasma mass spectrometry (ICP-MS) is useful instrument for determining abundance of rare earth elements, due to very low detection limits and rapid data acquisition. In this article, two methods are used for decomposition of alkaline rocks; close vessel acid digestion and $Na_2Co_3$ fusion. The two analytical results show good agreements. Considering total dissolved solids and detection limits, the most adequate dilution factor is 5,000 times. Polyatomic ion interferences during analysis can give rise to Inaccuracies. After correction from oxide and hydroxide interference, the analytical result show 20-30% decrease for Gd and Tm, 10-20% decrease for Tb and Er. In comparing the analytical results from KORDI with other institutes, most rare earth elements abundance show good agreements except Lu.

Analysis on power penalty due to timing jitters when considering intersymbol interference in the receivers on intensity modulation/direct detection optical communication systems (강도변조/직접검파 광통신 수신기에서 심벌간 간섭을 고려할 경우 타이밍 지터에 의한 잔력 페널티 해석)

  • 은수정;심요안;김부균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.4
    • /
    • pp.1077-1088
    • /
    • 1996
  • In this paper, we propose a new method to analyze the performance degradation by timing jitters in the receivers of intensity modulation/direct detection digital optical communication systems where pulse-shaping filters are used to minimize intersymbol interference. The results obtained from the proposed analytical method show that conventional analytical methods underestimate the influence of timing jitters on the receiver performance. Using the proposed anlaytical method, we derive an analytic equation for approximated power penalty due to timing itters and obtain an exact power penalty by numerical analyses. Assuming Gaussian or uniform probability density function for timing jitters, we also show that assumption of Gaussian distribution for timing jitters yields more performance degration than that of uniform distribution.

  • PDF

Detection of Bio-chemical by Boron-doped Diamond Electrode (붕소가 도핑된 다이아몬드 전극을 이용한 생체화학물질의 검출)

  • Kim, Gyu-Sik;Einaga, Y.;Fujishima, A.;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.569-572
    • /
    • 2001
  • Selective. highly stable determination of epinephrine(adrenalin) was achieved in cyclic voltammetric measurement carried out at electrochemically treated conductive boron-doped diamond electrode. Boron-doped diamond electrodes were prepared on single crystal Si wafers by microwave plasma chemical vapor deposition and $B_{2}O_{3}$ was dissolved in acetone/methanol(9:1) mixture solution so that the B/C weight ratio ca. $10^{4}ppm$. Epinephrine is a kind of catecholamines, which secreted from adrenal marrow cells. The serious problem to detection of epinephrine is the interference phenomena of electroactive constituent. including AA. In this study. electrochemical treatment of BDD was carried out to discriminate between epinephrine and AA responses. Experimental results showed that the peak potential of AA oxidation shift to the positive direction and the oxidation peak of epinephrine was unchanged. The effect of electrochemical treatment was maintained up to 40hrs.

  • PDF

Analysis of a user detection scheme in nakagami interferenence (나까가미 간섭에서 사용자 검파기의 해석)

  • 배진수;이주식;김석찬;송익호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.5
    • /
    • pp.949-955
    • /
    • 1997
  • Detection of the existence of a desired user is considered in this paper. We assume that the signal to noise ratio is high enough for us to ignore the effects of noise compared with those of the interference by other users. The inter-user interference and user signals are modeled by the Nakagami model. An observation model for this situation is proposed, the locally optimum test statistic is derived under the model, and the asymptotic performance of the locally optimum detector is compared with of the envelope detector. We show that the locally optimum detector performs better than the conventional envelope detector.

  • PDF