• Title/Summary/Keyword: Interference Test

Search Result 660, Processing Time 0.027 seconds

Interference-Free Tool Approach Directions in Multi-Axis NC Machining of Sculptured Surfaces (자유 곡면의 다축 NC 가공시 간섭 없는 공구 접근 자세 영역)

  • J.G. Kang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.7
    • /
    • pp.108-115
    • /
    • 1997
  • In this paper, an algorithm of computing interference-free tool approach directions(visibility cone) with consideration of tool volume at an arbitrary point of a sculptured surface is developed. The surface is first approximated into a polyhedron with smaller subpatches and the tool approach directions are evenly sampled so as to test accessibility. Then the visibility cone is computed by testing if each approach direction is interfered by other surface subpatches. The results are represented as the binary spherical map which transform geometric information on sphere into aogebraic one. The developed algorithm is implemented and tested by several sculptured surfaces, convincing it can be easily used as a tool for not only interference- free tool approach directions but also determining process planning of multi-axis NC machining of sculp- tured surfaces

  • PDF

A study on the measurement of stress intensity factor by laser interference (레이저 간섭법에 의한 응력확대계수 측정에 관한 연구)

  • 최상인;최선호;황재석;권재도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.806-812
    • /
    • 1988
  • When laser interference method is used to measure stress intensity factor with experiment, crack molded from teflon crack molding method is better than the crack manufactured through fatigue test. It is known that center distance between two indentations which is best for detecting the laser interference fringe order is about 80.mu.m with photodetector used in this research. Errors with measurement of stress intensity factor through laser interference are between 2% and 11%, therefore, experimental process and method developed in this research can be used with obtaining the more precision experimental data for stress intensity factors.

An Experimental Study on Frequency Characteristics of the Microphone Array Covered with Kevlar in Closed Test Section Wind Tunnel (폐쇄형 시험부에서 케블라 덮개가 장착된 마이크로폰 어레이의 주파수 특성에 대한 실험적 연구)

  • Hwang, Eun-Sue;Choi, Youngmin;Kim, Yangwon;Cho, Taehwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.3
    • /
    • pp.150-159
    • /
    • 2015
  • An experimental study on frequency characteristics of the microphone array covered with Kevlar sheet was conducted in the closed test section. Microphones that were flush-mounted in the wall of wind tunnel were subjected to very high flow noise resulting from the turbulence in the wall boundary layer. This noise interference by the boundary layer was referred as 'a microphone self-noise' and various approaches were studied to reduce this interference. Recessed microphone array with high tensioned cover was one of the good approaches to reduce this self-noise. But, the array cover could cause an unexpected interference to the measuring results. In this paper the frequency characteristics of the microphone array with Kevlar cover was experimentally studied. The white noise was used as a reference noise source. Three kinds of tensions for the Kevlar cover were tested and those results were compared with the test results without the Kevlar cover. The gap effect between the cover and microphone head was also tested to find out the proper position of microphone in the array module. Test results show that the mid-tension and 10mm gap was the best choice in the tested cases.

Study on the Correction of a Wing-tail Interference Effect in a Semi-empirical Aerodynamic Analysis Tool (반경험적 공력 해석도구의 주날개-꼬리날개 간섭 효과 보정에 대한 연구)

  • Lee, Dae-Yeon;Kim, Jae-Hyun;Kang, Dong-Gi
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.2
    • /
    • pp.85-93
    • /
    • 2021
  • In this paper, the aerodynamic characteristics of general tail controlled missile were predicted and corrected the result using semi-empirical analysis tool. The cause of the error was confirmed by comparing the aerodynamic characteristics prediction result of the semi-empirical analysis tool with the wind tunnel test result, and the main error factor of the semi-empirical analysis tool was the interference component between the main wing and the tail wing. The semi-empirical analysis results were corrected using the wind tunnel test results and the computational analysis results, and it was confirmed that the corrected data agrees well with the wind tunnel test results. Through this study, it was confirmed that the wing-tail interference component correction is needed when predicting the aerodynamic characteristics of a general tail controlled missile using a semi-empirical analysis tool.

Characteristics of the aerodynamic interference between two high-rise buildings of different height and identical square cross-section

  • Dongmei, Huang;Xue, Zhu;Shiqing, He;Xuhui, He;Hua, He
    • Wind and Structures
    • /
    • v.24 no.5
    • /
    • pp.501-528
    • /
    • 2017
  • In this work, wind tunnel tests of pressure measurements are carried out to assess the global aerodynamic interference factors, the local wind pressure interference factors, and the local lift spectra of an square high-rise building interfered by an identical cross-sections but lower height building arranged in various relative positions. The results show that, when the interfering building is located in an area of oblique upstream, the RMS of the along-wind, across-wind, and torsional aerodynamic forces on the test building increase significantly, and when it is located to a side, the mean across-wind and torsional aerodynamic forces increase; In addition, when the interfering building is located upstream or staggered upstream, the mean wind pressures on the sheltered windward side turn form positive to negative and with a maximum absolute value of up to 1.75 times, and the fluctuating wind pressures on the sheltered windward side and leading edge of the side increase significantly with decreasing spacing ratio (up to a maximum of 3.5 times). When it is located to a side, the mean and fluctuating wind pressures on the leading edge of inner side are significantly increased. The three-dimensional flow around a slightly-shorter disturbing building has a great effect on the average and fluctuating wind pressures on the windward or cross-wind faces. When the disturbing building is near to the test building, the vortex shedding peak in the lift spectra decreases and there are no obvious signs of periodicity, however, the energies of the high frequency components undergo an obvious increase.

Test-Bed Implementation for Real-Time Frequency Interference Analysis between Unlicensed Devices (비면허기기 간 실시간 주파수간섭 분석 테스트베드 구현)

  • Park, Jin-Soo;Yoon, Hyun-Goo;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.6
    • /
    • pp.589-592
    • /
    • 2015
  • In this paper, we suggested a real-time test-bed for analyzing frequency interference between 2.4 GHz unlicensed devices, such as WiFi, Zigbee, etc. Owing to versatile programming capability of Universal Software Radio Peripheral(USRP) and $Labview^{TM}$, frequency interference environments can be easily modeled. Therefore, performance degradation effects due to various parameters of interferer and victim receiver can be analyzed intuitively. For verification, we showed a frequency interference scenario, which consists of IEEE 802.15.4 as a victim and IEEE 802.11b as a interferer. Measured Bit Error Rate(BER) results showed good agreement with theory and simulation results.

An Evaluation of Pullout Behavior Characteristics of the Steel Strip Reinforcement Bolted with Braced Angles (버팀재 볼트 접합형 강재스트립 보강재의 인발거동특성 평가)

  • 김홍택;방윤경;정중섭;박시삼;김현조
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.419-426
    • /
    • 2002
  • In this study, the steel strip reinforcement bolted with braced angles is displayed skin friction resistance as well as passive resistance through existing the steel strip reinforcement. To understand pullout behavior characteristics, friction effects between soil and reinforcement are evaluated with the width of reinforcement, magnitude of surcharge, and existence of passive resistance member through laboratory pullout test. To analyze interference effects for passive resistance member, various tests are carried on case that the number, the location, and the spacing of braced angles are different. Using this test result, pullout resistance factor is calculated to consider location of braced angles and degree of interference for spacing ratio.

  • PDF

Pulse-to-Pulse Coding for Channel Interference Suppression of Short Range Radar for GVES (지상 기동 장비용 근거리 레이더의 채널 간섭 억제를 위한 펄스간 코딩 연구)

  • Park, Gyu-Churl;Ha, Jong-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.883-889
    • /
    • 2009
  • Since the SRRs(Short Range Radar) load on the GVESs(Ground Vehicle Equipment System) are operated within several hundred meters, it is important to suppress the interferences between the SRRs. These interference are reduced using the frequency separation between channels, however this method isn't a perfect solution owing to a difficulty of a realization for the interference suppression. Thus, a pulse-to-pulse coding used to suppress the interference fundamentally is proposed in this paper. The concept, the application method and the test results of the proposed method have been described in this paper.

The Spectral Domain K-median Threshold Filtering Method for the Dynamic GPS Interference Excision (동적 GPS 간섭신호 제거에 효율적인 주파수 영역에서의 K-median 필터를 이용한 문턱치 설정 기법)

  • Kim, Jun O;Lee, Sang Jeong
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.3
    • /
    • pp.243-250
    • /
    • 2017
  • GPS(Global Positioning System) signal structure uses spread spectrum and the received power is relatively lower than the receiver noise figure. Therefore, it is vulnerable to the RF interferences and it could restrict on the safety navigation. The objective of this paper is to research on the spectral domain GPS interference rejection algorithm using proposed K-median filtering threshold setting method. In the performance test, the proposed algorithm has a relatively higher ISR(interference to signal ratio) compared with the conventional temporal domain technique in case of time variant interference signals.

An Analysis of Potential Interference in the Vicinity of the Vertical Ground Rod (수직 접지전극 주변에서 전위간섭의 분석)

  • Lee, Bok-Hee;Lee, Kang-Soo;Seong, Chang-Hoon;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.85-91
    • /
    • 2011
  • A grounding system is generally composed of several vertical, horizontal electrodes or grids. Excessive ground potential rises due to adjacent grounding electrodes can cause failures or misoperation of electronic devices and control systems. It is therefore necessary for computer-related and information-oriented equipment to be placed at a sufficient distance from the areas influenced by grounding electrodes. In this paper, in order to propose a method for evaluating the ground potential rise and interference in the vicinity of vertical grounding electrodes, the experimental and theoretical results on the potential interference between vertical grounding electrodes and its frequency dependence were described. The ground potential rise is sharply decreased with increasing the distance between grounding electrodes. In case that the separation of vertical grounding electrodes is less than 1.5[m], the potential interference coefficient was greater than 0.1 and linearly increased with the frequency of the test current within the frequency of 1[MHz].