• Title/Summary/Keyword: Interference Diagram

Search Result 23, Processing Time 0.026 seconds

Analytical Eye-Diagram Determination for the Efficient and Accurate Signal Integrity Verification of Coupled Interconnect Lines

  • Lee, Minji;Kim, Dongchul;Eo, Yungseon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.594-607
    • /
    • 2013
  • A new efficient analytical eye-diagram determination technique for coupled interconnect lines is presented. Two coupled lines are decoupled into isolated eigen modes; bit blocks for coupled lines, which are defined as a block of consecutive bits, are then represented with decoupled modes. The crosstalk effects within the bit blocks are taken into account. Thereby, the crucial input bit patterns for the worst case eye-diagram determination are modeled mathematically, including inter-symbol interference (ISI). The proposed technique shows excellent agreement with the SPICE-based simulation. Furthermore, it is very computation-time-efficient in the order of magnitude, compared with the SPICE simulation, which requires numerous pseudo-random bit sequence (PRBS) input signals.

Fixed Decision Delay Detector for Intersymbol Interference Channel (심볼간 간섭 채널을 위한 고정 지연 신호 검출기)

  • Taehyun, Jeon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.9
    • /
    • pp.39-45
    • /
    • 2004
  • A design method is proposed for the sequence detection with fixed decision delay with less hardware complexity using the concept of the Voronoi diagram and its dual, the Delaunay tessellation. This detector design is based on the Fixed Delay Tree Search (FDTS) detection. The FDTS is a computationally efficient sequence detection algerian and has been shown to achieve near-optimal performance in the severe Intersymbol Interference (ISI) channels when combined with decision feedback equalization and the appropriate channel coding. In this approach, utilizing the information contained in the Voronoi diagram or equivalently the Delaunay tessellation, the relative location of the detector input sequence in the multi-dimensional Euclidean space is found without any computational redundancy, which leads to a reduced complexity implementation of the detector.

Vibration Analysis for LP Turbine Blade Damage (저압터빈 블레이드 손상에 대한 진동 해석)

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Yeon-Hwan;Lee, Hyun;Kim, Sung-Hwi
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.752-757
    • /
    • 2003
  • The steady stress, modal analysis for the damaged blade was carried out to evaluate the integrity of LP 4 blade row. As a result, 4 dangerous modes for LP blade row were found in the interference diagram and it was confirmed that the nozzle passing frequency has nothing to do with the blade failure. And then the dynamic stress are analysed for the 4 dangerous modes. There are some points far out of maximum allowable stress in the cover and tenon. Therefore the blade is not safe according to the Goodman judgement. So the manufacturer have modified the design of cover and tenon. Until now, the power plant is being operated without special problems.

  • PDF

Data Retrieval by Multi-Dimensional Signal Space Partitioning (다차원 신호공간 분할을 이용한 데이터 복원)

  • Jeon, Taehyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.6
    • /
    • pp.674-677
    • /
    • 2004
  • This paper deals with a systematic approach for the construction of the fixed-delay tree search (FDTS) detector in the intersymbol interference channel. The approach is based on the efficient multi-dimensional space partitioning. The Voronoi diagram (VoD) and the Delaunay tessellation (DT) of the multi-dimensional space are applied to implement the algorithm. In the proposed approach, utilizing the geometric information contained in the VOD/DT, the relative location of the observation sequence is determined which has been shown to reduce the implementation complexity. Detailed construction procedures are discussed followed by an example from the intersymbol interference communication channel.

Identification of Failure Cause for 300MW LP turbine Blade through Vibration Analysis (진동 해석을 통한 300MW급 저압터빈 블레이드의 손상 원인 규명)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.794-799
    • /
    • 2005
  • The failure of blades frequently happened in the 300MW LP turbine until now and they are maintaining the blades periodically during outage. So the blade-disk system is analysed by FEM in order to identify the main cause of failure of blade row. It is found that the stress of root's hole is highest in comparison with other parts from the result of the steady stress analysis. Also, the two dangerous frequencies which is related to the resonance condition are found in the interference diagram. one is 1,516 Hz which is related to the operating speed. The other is 2,981 Hz which is related to the 1 nozzle passing frequency. The dynamic stress analysis is per-formed to identify more accurate root cause for failure of blade row. It is confirmed that the dynamic stress of the latter is higher than one of the former. From these results, it is concluded that the former has deeply something to do with the failure of blades more than the latter. Based on versatile investigation and deliberation, the change of blade's grouping is determined to avoid the resonance condition with the operating speed. After the blade grouping is changed, the former frequency vanish completely but the latter is still in existence in the interference diagram. Fortunately, It is confirmed that the dynamic stress of the new blade grouping is lower than one of the old blade grouping. 2 years has passed since modification and the LP turbine is operated well without failure so far.

  • PDF

Identification of Failure Cause for 300 MW LP Turbine Blade through Vibration Analysis (진동 해석을 통한 300 MW급 저압터빈 블레이드의 손상 원인 규명)

  • Bae, Yong-Chae;Lee, Hyun;Kim, Hee-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1100-1107
    • /
    • 2005
  • The failure of blades frequently happened in the 300 MW LP(low pressure) turbine until now and they are maintaining the blades periodically during outage. So the blade-disk system is analysed by FEM in order to identify the main cause of failure of blade row. It is found that the stress of root's hole is highest in comparison with other parts from the result of the steady stress analysis. Also, the two dangerous frequencies which is related to the resonance condition are found in the interference diagram. One is 1,316 Hz. The other is 2,981 Hz which is related to the 1 nozzle passing frequency. The dynamic stress analysis is performed to identify more accurate root cause for failure of blade row It is confirmed that the dynamic stress of the former is higher than one of the latter From these results, it is concluded that the former has deeply something to do with the failure of blades more than the tatter. Based on versatile investigation and deliberation, the change of blade's grouping is determined to avoid the resonance condition with the operating speed. After the blade grouping is changed, the former frequency vanish completely but the latter is still in existence in the interference diagram. Fortunately, It is confirmed that the dynamic stress of the new blade grouping is lower than one of the old blade grouping. 2 years has passed since modification and the LP turbine is operated well without failure so far.

PID Controller Tuning using Co-Efficient Diagram method for Indirect Vector Controlled Drive

  • Durgasukumar, G.;Rama Subba Redddy, T.;Pakkiraiah, B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1821-1834
    • /
    • 2017
  • Medium voltage control applications due to obtain better output voltage and reduced electro-magnetic interference multi level inverter is used. In closed loop control with inverter, the PI controller does not operate satisfactorily when the operating point changes. This paper presents the performance of Co-Efficient diagram PI controller based indirect vector controlled induction motor drive fed from three-level inverter under different operating conditions (dynamic and steady state). The proposed Co-Efficient diagram PI controller based three level inverter significantly reduces the torque ripple compared to that of conventional PI controller. The performance of the indirect vector controlled induction motor drive has been simulated at different operating conditions. For three-level inverter control, a simplified space vector modulation technique is implemented, which reduces the coordinate transformations complications in the algorithms. The performance parameters, torque ripple contents and THD of induction motor drive with three-level inverter is compared under different operating conditions using CDM-PI and conventional PI controllers.

A Rotordynamics Analysis of High Efficiency and Hybrid Type Vacuum Pump (고효율 복합형 진공펌프의 로터다이나믹 해석)

  • Kim, Byung-Ok;Lee, An-Sung;Noh, Myung-Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.10
    • /
    • pp.967-975
    • /
    • 2007
  • A rotordynamic analysis was performed with a dry vacuum pump, which is a major equipment in modern semiconductor and LCD manufacturing processes. The system is composed of screw rotors, lobes picking air, helical gears, driving motor, and support rolling element bearings of rotors and motor. The driving motor-screw rotor system has a rated speed of 6,300 rpm, and was modeled utilizing a rotordynamic FE method for analysis, which was verified through 3-D FE analysis and experimental modal analysis. As loadings on the bearings due to the gear action were significant in the system considered, each resultant bearing load was calculated by considering the generalized forces of the gear action as well as the rotor itself. Each resultant bearing loading was used in calculating each stiffness of rolling element bearings. Design goals are to achieve wide separation margins of lateral and torsional critical speeds, and favorable unbalance responses of the rotor in the operating range. Then, a complex rotordynamic analysis of the system was carried out to evaluate its forward synchronous critical speeds, whirl natural frequencies and mode shapes, unbalance responses under various unbalance locations, and torsional interference diagram. Results show that the entire system is well designed in the operating range. In addition, the procedure of rotordynamic analysis for dry vacuum pump rotor-bearing system was proposed and established.

Vibration Analysis for the L-1 Stage Bladed-disk of a LP Steam Turbine (증기터빈 저압 L-1단 블레이드-디스크 연성 진동 특성 분석)

  • Lee, Doo-Young;Bae, Yong-Chae;Kim, Hee-Soo;Lee, Yook-Ryun;Kim, Doo-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.1
    • /
    • pp.29-35
    • /
    • 2010
  • This paper studies causes of the L-1 blade damage of a low pressure turbine, which was found during the scheduled maintenance, in 500 MW fossil power plants. Many failures of turbine blades are caused by the coupling of aerodynamic forcing with bladed-disk vibration characteristics. In this study the coupled vibration characteristics of the L-1 turbine bladed-disk in a fossil power plant is shown for the purpose of identifying the root cause of the damage and confirming equipment integrity. First, analytic and experimental modal analysis for the bladed-disk at zero rpm as well as a single blade were performed and analyzed in order to verify the finite element model, and then steady stresses, natural frequencies and corresponding mode shapes, dynamic stresses were calculated for the bladed-disk under operation. Centrifugal force and steady steam force were considered in calculation of steady and dynamic stress. The proximity of modes to sources of excitation was assessed by means of an interference diagram to examine resonances. In addition, fatigue analysis was done for the dangerous modes of operation by a local strain approach. It is expected that these dynamic characteristics will be used effectively to identify the root causes of blade failures and to perform prompt maintenance.