• Title/Summary/Keyword: Interface-type

Search Result 1,686, Processing Time 0.033 seconds

Design of R-type thermocouple interface with cold-junction compensator and its broken wire detection (냉점보상과 단선감지 기능을 갖는 R-형 열전쌍 인터페이스 설계)

  • Cha, Hyeong-Woo;Kim, Young-Sun;Park, So-Hyun;Hyun, Pil-Soo;Kim, Dae-Han;Yun, Young-Sik;Ryu, Ho-Young;Kim, Byung-Ju
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.847-848
    • /
    • 2006
  • R-type thermocouple(TC) interface circuits with cold-junction compensator(CJC) and its broken wires detection was developed. The circuit consists of a CJC device, a instrumentation amplifier(IA), and two resistor and a diode for broken wire detection. The experiment results show that the interface circuit has a good CJC function on the temperature range for $20^{\circ}C$ to $1400^{\circ}C$. At the range the output voltage of the IA was -14V when the TC was broken. At normal operation condition the output voltage of IA was 0V to 10V for the temperature range.

  • PDF

A study on the mechanical properties of geosynthetic interface (토목섬유 접촉면의 역학적 특성에 관한 연구)

  • Nam, Yong;Kim, Gwang-Ho;Im, Jong-Chul;Ju, In-Gon;Kwon, Jeong-Geun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1540-1549
    • /
    • 2009
  • Shear properties of geosynthetic/geosynthetic and geosynthetic/soil were evaluated from direct shear tests. The type of geosynthetic is Velcro which is effective for geosynthetic interface and make up for the weakness of sandbag. In this study, the cohesion and the angle of internal friction of each interface was estimated. The test results showed that the cohesion and the angle of internal friction of the geosynthetics depended on the amount of normal stress, the type of the geosynthetics used, and combinations of the geosynthetics and soils. Finally, by comparing the apparent cohesion and the friction angle of the geosynthetics, the applicability to design was identified.

  • PDF

Characterization of Thermal Contact Resistance Doped with Thermal Interface Material (접촉열전도재를 도포한 접촉열저항 특성연구)

  • Bajracharya, Iswor;Ito, Yoshimi;Nakayama, Wataru;Moon, Byeong-Jun;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.9
    • /
    • pp.943-950
    • /
    • 2013
  • This paper describes the thermal contact resistance and its effect on the performance of thermal interface material. An ASTM D 5470 based apparatus is used to measure the thermal interface resistance. Bulk thermal conductivity of different interface material is measured and compared with manufacturers' data. Also, the effect of grease void in the contact surface is investigated using the same apparatus. The flat type thermal interface tester is proposed and compared with conventional one to consider the effect of lateral heat flow. The results show that bulk thermal conductivity alone is not the basis to select the interface material because high bulk thermal conductivity interface material can have high thermal contact resistance, and that the center voiding affects the thermal interface resistance seriously. On the aspect of heat flow direction, thermal impedance of the lateral heat flow shows higher than that of the longitudinal heat flow by sixteen percent.

Structural Study of Interface Layers in Tetragonal-NiSi (010)/Si using Density Functional Theory (밀도범함수를 이용한 정방정계-NiSi (010)/Si 계면 층의 구조 연구)

  • Kim, Dae-Hee;Kim, Dae-Hyun;Seo, Hwa-Il;Kim, Yeong-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.5
    • /
    • pp.377-381
    • /
    • 2009
  • Tetragonal-NiSi (010)/Si superstructures were calculated for studying the interface structure using density functional theory, The orthorhombic-NiSi was changed to the tetragonal-NiSi to be matched with the Si surface for epitaxy interface. The eight interface models were produced by the type of the Si surfaces, The tetragonal-NiSi (010)/Si (020)[00-1] superstructure was energetically the most favorable, and the interface thickness of this superstructure was the shortest among the tetragonal-NiSi (010)/Si superstructures. However, in the case of tetragonal-NiSi (010)/Si (010)[00-1] superstructure, it was energetically the most unfavorable, and the interface thickness was the longest. The energies and interface thicknesses of tetragonal-NiSi (010)/Si superstructures were influenced by the coordination number of Ni atoms and the bond length between atoms located at the interface.

비틀림하의 복합원통에 있는 원주 표면균열에 대한 응력 확대 계수

  • Kim, Yeong-Jong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.151-157
    • /
    • 2000
  • Stress intensity factors for the circumferential surface crack of a long composite cylinder under torsion is investigated. The problem is formulated as a singular integral equation of the first kind with a Cauchy type kernel using the integral transform technique. The mode III stress intensity factors at the crack tips are presented when (a) the inner crack tip is away from the interface and (b) the inner crack tip is at the interface.

  • PDF

FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM (내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구)

  • Lee Heung-Tae;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.

Forced vibration of the elastic system consisting of the hollow cylinder and surrounding elastic medium under perfect and imperfect contact

  • Akbarov, Surkay D.;Mehdiyev, Mahir A.
    • Structural Engineering and Mechanics
    • /
    • v.62 no.1
    • /
    • pp.113-123
    • /
    • 2017
  • The bi-material elastic system consisting of the circular hollow cylinder and the infinite elastic medium surrounding this cylinder is considered and it is assumed that on the inner free face of the cylinder a point-located axisymmetric time harmonic force, with respect to the cylinder's axis and which is uniformly distributed in the circumferential direction, acts. The shear-spring type imperfect contact conditions on the interface between the constituents are satisfied. The mathematical formulation of the problem is made within the scope of the exact equations of linear elastodynamics. The focus is on the frequency-response of the interface normal and shear stresses and the influence of the problem parameters, such as the ratio of modulus of elasticity, the ratio of the cylinder thickness to the cylinder radius, and the shear-spring type parameter which characterizes the degree of the contact imperfectness, on these responses. Corresponding numerical results are presented and discussed. In particular, it is established that the character of the influence of the contact imperfection on the frequency response of the interface stresses depends on the values of the vibration frequency of the external forces.

A Study On the Improvement Of Proset2000 by a Design Method Using the Uinfied Modelling Language (UML을 사용한 디자인 방법에 의한 계통보호 종합전산 프로그램의 개선에 관한 연구)

  • 최면송;현승호;오성민;오태욱
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.7-12
    • /
    • 2004
  • The role of protective relay with correct setting value is very important for the reliable operation of power : system. The setting process of a protective relay is difficult and requires hard work of calculations. Therefore, KEPCO as been using PROSET2000, a computer program system, in order to automate the setting process of protective relays in power transmission network since 2000. This system has a database and relay setting modules for each type of realy with coresponding Human and Computer Interaction(HCI). For the setting of a new type of relay, it require a new module, a HCI and a database table corresponding to the new relay. But it's update is not easy in case of new type of relay. This paper discussed the update method introducing a concept of Open Interface. It addressd a method to make a new HCI for new relay in view of object-oriented method using UML(Unified Modeling Language). Using the UML, we updated the PROSET2000. HCI screens for a new relay is generated automatically using the information of the new relay stored in the database. And, the database management module is upgraded to solve problems in manage and maintain the database in view of Open Interface.

A graphical user interface for stand-alone and mixed-type modelling of reinforced concrete structures

  • Sadeghian, Vahid;Vecchio, Frank
    • Computers and Concrete
    • /
    • v.16 no.2
    • /
    • pp.287-309
    • /
    • 2015
  • FormWorks-Plus is a generalized public domain user-friendly preprocessor developed to facilitate the process of creating finite element models for structural analysis programs. The lack of a graphical user interface in most academic analysis programs forces users to input the structural model information into the standard text files, which is a time-consuming and error-prone process. FormWorks-Plus enables engineers to conveniently set up the finite element model in a graphical environment, eliminating the problems associated with conventional input text files and improving the user's perception of the application. In this paper, a brief overview of the FormWorks-Plus structure is presented, followed by a detailed explanation of the main features of the program. In addition, demonstration is made of the application of FormWorks-Plus in combination with VecTor programs, advanced nonlinear analysis tools for reinforced concrete structures. Finally, aspects relating to the modelling and analysis of three case studies are discussed: a reinforced concrete beam-column joint, a steel-concrete composite shear wall, and a SFRC shear panel. The unique mixed-type frame-membrane modelling procedure implemented in FormWorks-Plus can address the limitations associated with most frame type analyses.