• 제목/요약/키워드: Interface parameter

검색결과 360건 처리시간 0.028초

Digital Hearing Aid DSP Chip Parameter Fitting Optimization

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1820-1825
    • /
    • 2005
  • DSP chip parameters of a digital hearing aid (HA) should be optimally selected or fitted for hearing impaired persons. The more precise parameter fitting guarantees the better compensation of the hearing loss (HL). Digital HAs adopt DSP chips for more precise fitting of various HL threshold curve patterns. A specific DSP chip such as Gennum GB3211 was designed and manufactured in order to match up to about 4.7 billion different possible HL cases with combination of 7 limited parameters. This paper deals with a digital HA fitting program which is developed for optimal fitting of GB3211 DSP chip parameters. The fitting program has completed features from audiogram input to DSP chip interface. The compensation effects of the microphone and the receiver are also included. The paper shows some application examples.

  • PDF

CATIA KW의 변수 및 지체 관리를 위한 지원 모듈 개발 (Development of supporting Modules for parameter and knowledge management using CATIA KW)

  • 주수석;배일주;이수홍;전찬모;장준현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.635-636
    • /
    • 2006
  • A knowledge-based system with CAD is widely used to implement a designer's know-how and a routine calculation within a system. An engineer needs to change several design parameters in an early design stage. However it is not easy to change the design parameters when it needs to update an existing model and data. In this paper, a module has been proposed to make it easy to change the design parameter so that the engineer can easily update and change the design model. Also a flexible interface of the module can easily add or extract the design knowledge.

  • PDF

디지털 보청기 DSP Chip 파라미터 적합 최적화 (Digital Hearing Aid DSP Chip Parameter Fitting Optimization)

  • 장순석
    • 제어로봇시스템학회논문지
    • /
    • 제12권6호
    • /
    • pp.530-538
    • /
    • 2006
  • DSP chip parameters of a digital hearing aid (HA) should be optimally selected or fitted for hearing impaired persons. The more precise parameter fitting guarantees the better compensation of the hearing loss (HL). Digital HAs adopt DSP chips for more precise fitting of various HL threshold curve patterns. A specific DSP chip such as Gennum GB3211 was designed and manufactured in order to match up to about 4.7 billion different possible HL cases with combination of 7 limited parameters. This paper deals with a digital HA fitting program which is developed for optimal fitting of GB3211 DSP chip parameters. The fitting program has completed features from audiogram input to DSP chip interface. The compensation effects of the microphone and the receiver are also included. The paper shows some application examples.

SNMP를 이용한 인터넷 분석 파라미터 추출 시스템의 설계 및 구현 (The Design and Implementation of Parameter Extraction System for Analyzing Internet Using SNMP)

  • 신상철;안성진;정진욱
    • 한국정보처리학회논문지
    • /
    • 제6권3호
    • /
    • pp.710-721
    • /
    • 1999
  • In this paper, we have designed and implemented a parameter extraction system for analyzing Internet using SNMP. The extraction system has two modules; one is collection request module, and the other is analysis request module. The collection request module generates a polling script, which is used to collect management information from the managed system periodically. With this collected data, analysis request module extracts analysis parameters. These parameters are traffic flow analysis, interface traffic analysis, packet traffic analysis, and management traffic analysis parameter. For management activity, we have introduced two-step-analysis-view. One is Summary-View, which is used find out malfunction of a system among the entire managed systems. The Other is Specific-View. With this view we can analyze the specific system with all our analysis parameters. To show available data as indicators for line capacity planning, network redesigning decision making of performance upgrade for a network device and things like that.

  • PDF

테라급 스위치 패브릭 인터페이스를 위한 고속 신호 전송로의 성능 분석 (Performance Analysis of High-Speed Transmission Line for Terabit Per Second Switch Fabric Interface)

  • 최창호;김환우
    • 전자공학회논문지
    • /
    • 제51권12호
    • /
    • pp.46-55
    • /
    • 2014
  • 고속 전송로를 위한 PCB(Printed Circuit Board) 설계기술은 꾸준히 발전되고 있으며, 통신 시스템의 대용량화에 맞추어 백플레인(Backplane)에 사용되는 스위치 패브릭 인터페이스(Switch Fabric Interface) 또한 10Gbps 이상의 직렬 인터페이스(Serial Interface)를 사용하도록 표준화가 진행되고 있다. 본 논문에서는 테라급 시스템에서 스위치 패브릭 인터페이스로 11.5Gbps의 직렬링크를 사용하기 위하여, PCB 재질 따른 전송로의 전송거리 별 성능을 비교하고, 비아 스터브(Via Stub)의 길이에 의한 영향 및 누화현상(Crosstalk)에 의한 영향을 시뮬레이션을 수행하여 분석하였다. 시뮬레이션의 결과로 백플레인 보드에 저유전 재질 PCB를 사용함으로써, 전송손실에서 8dB의 개선효과를 얻어 표준에서 정한 -25dB 기준을 만족하는 것을 확인하였다. 또한 비아 스터브 길이에 의한 반사손실의 영향을 분석하여 백드릴(Back-drill)여부를 결정하였으며, 전송신호 간 상호간섭을 최소화하는 이격거리를 검증하였다. 이러한 시뮬레이션의 결과로부터 모든 스위치 패브릭 링크에 11.5Gbps의 직렬 링크를 적용할 수 있도록 가장 효율적인 시스템구조를 확정하였다.

Ultrasonic Evaluation of Interfacial Stiffness for Nonlinear Contact Surfaces

  • Kim, Noh-Yu;Kim, Hyun-Dong;Cho, Youn-Ho
    • 비파괴검사학회지
    • /
    • 제28권6호
    • /
    • pp.504-511
    • /
    • 2008
  • This paper proposes an ultrasonic measurement method for measurement of linear interfacial stiffness of contacting surface between two steel plates subjected to nominal compression pressures. Interfacial stiffness was evaluated by using shear waves reflected at contact interface of two identical solid plates. Three consecutive reflection waves from solid-solid surface are captured by pulse-echo method to evaluate the state of contact interface. A non-dimensional parameter defined as the ratio of their peak-to-peak amplitudes are formulated and used to calculate the quantitative stiffness of interface. Mathematical model for 1-D wave propagation across interfaces is developed to formulate the reflection and transmission waves across the interface and to determine the interfacial stiffness. Two identical plates are fabricated and assembled to form contacting surface and to measure interfacial stiffness at different states of contact pressure by means of bolt fastening. It is found from experiment that the amplitude of interfacial stiffness is dependent on the pressure and successfully determined by employing pulse-echo ultrasonic method without measuring through-transmission waves.

5급 복합레진충전된 치아에 있어서의 계면조건과 유지구의 영향에 대한 2차원유한요소법적 연구 (TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE EFFECT OF INTERFACE CONDITION AND RETENTION GROOVE IN CLASS V COMPOSITE RESIN RESTORATION)

  • 조병훈;유현미;김동호
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.639-646
    • /
    • 1998
  • To evaluate the effect of interface conditions and retention grooves in the Class V composite resin restoration of the maxillary first premolar, the distribution of the values of stress and displacement was analyzed with the two-dimensional finite element method. The results were obtained as follows : 1. Boundary elements and Stiffness values could be used as the interface parameters in the, finite element method. 2. The amount of restriction of the displacement at the cervical margin by placing a retention groove at the cervical wall was about three times as high as that by placing a retention groove at the occlusal wall. 3. Because of the relative amount of tensile components of the stress values in the bucco-lingual direction, the possibility of dislocation of the restoration was much higher at the cervical margin than at the occlusal margin. 4. It might be recommended that both occlusal and cervical retention grooves be used routinely, but if one, it be placed at the cervical wall.

  • PDF

균열에너지밀도에 의한 이종재 계면균열의 기초적 검토 (A Fundamental Analysis of an Interface Crack by Crack Energy Density)

  • 권오헌;도변승언;서창민;김영호
    • 대한기계학회논문집
    • /
    • 제16권8호
    • /
    • pp.1458-1467
    • /
    • 1992
  • 본 연구에서는 균질재에서의 결과를 토대로 이종재에서도 그 성질이 보존될 것으로 기대되기 때문에 계면균열에서의 CED의 기본적 성질을 검토한후, 각 모드 인자 의 분리법과 평가법을 CED를 통해 제시한다. 또 제시한 수법을 이용하여 우선 탄성 균열 모델에서 유한요소해석을 통해 CED 및 각 모드 인자의 평가 및 기초적 검토를 실시하여 그 유효성을 확인한다.

The influence of systemically administered oxytocin on the implant-bone interface area: an experimental study in the rabbit

  • Cho, Sung-Am;Park, Sang-Hun;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.505-511
    • /
    • 2014
  • PURPOSE. The purpose of this study was to assess the effect of systemically administered oxytocin (OT) on the implant-bone interface by using histomorphometric analysis and the removal torque test. MATERIALS AND METHODS. A total of 10 adult, New Zealand white, female rabbits were used in this experiment. We placed 2 implants (CSM; CSM Implant, Daegu, South Korea) in each distal femoral metaphysis on both the right and left sides; the implants on both sides were placed 10 mm apart. In each rabbit, 1 implant was prepared for histomorphometric analysis and the other 3 were prepared for the removal torque test (RT). The animals received intramuscular injections of either saline (control group; 0.15 M NaCl) or OT (experimental group; $200{\mu}g/rabbit$). The injections were initiated on Day 3 following the implant surgery and were continued for 4 subsequent weeks; the injections were administered twice per day (at a 12-h interval), for 2 days per week. RESULTS. While no statistically significant difference was observed between the two groups (P=.787), the control group had stronger removal torque values. The serum OT concentration (ELISA value) was higher in the OT-treated group, although no statistically significant difference was found. Further, the histomorphometric parameter (bone-to-implant contact [BIC], inter-thread bone, and peri-implant bone) values were higher in the experimental group, but the differences were not significant. CONCLUSION. We postulate that OT supplementation via intramuscular injection weakly contributes to the bone response at the implant-bone interface in rabbits. Therefore, higher concentrations or more frequent administration of OT may be required for a greater bone response to the implant. Further studies analyzing these aspects are needed.

Creation of regression analysis for estimation of carbon fiber reinforced polymer-steel bond strength

  • Xiaomei Sun;Xiaolei Dong;Weiling Teng;Lili Wang;Ebrahim Hassankhani
    • Steel and Composite Structures
    • /
    • 제51권5호
    • /
    • pp.509-527
    • /
    • 2024
  • Bonding carbon fiber-reinforced polymer (CFRP) laminates have been extensively employed in the restoration of steel constructions. In addition to the mechanical properties of the CFRP, the bond strength (PU) between the CFRP and steel is often important in the eventual strengthened performance. Nonetheless, the bond behavior of the CFRP-steel (CS) interface is exceedingly complicated, with multiple failure causes, giving the PU challenging to forecast, and the CFRP-enhanced steel structure is unsteady. In just this case, appropriate methods were established by hybridized Random Forests (RF) and support vector regression (SVR) approaches on assembled CS single-shear experiment data to foresee the PU of CS, in which a recently established optimization algorithm named Aquila optimizer (AO) was used to tune the RF and SVR hyperparameters. In summary, the practical novelty of the article lies in its development of a reliable and efficient method for predicting bond strength at the CS interface, which has significant implications for structural rehabilitation, design optimization, risk mitigation, cost savings, and decision support in engineering practice. Moreover, the Fourier Amplitude Sensitivity Test was performed to depict each parameter's impact on the target. The order of parameter importance was tc> Lc > EA > tA > Ec > bc > fc > fA from largest to smallest by 0.9345 > 0.8562 > 0.79354 > 0.7289 > 0.6531 > 0.5718 > 0.4307 > 0.3657. In three training, testing, and all data phases, the superiority of AO - RF with respect to AO - SVR and MARS was obvious. In the training stage, the values of R2 and VAF were slightly similar with a tiny superiority of AO - RF compared to AO - SVR with R2 equal to 0.9977 and VAF equal to 99.772, but large differences with results of MARS.