• Title/Summary/Keyword: Interface debonding

Search Result 142, Processing Time 0.023 seconds

Temperature Dependent Failure Machanisms of CaCO3 / PP Particulates ($CaCO_3$ / PP 입자 강화 복합재료의 온도변화에 따른 파괴기구)

  • Koh, Sung-Wi;Kim, Hyung-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.3
    • /
    • pp.220-226
    • /
    • 1994
  • In this paper the failure mechanisms of polypropylene resin composites filled with calcium carbonate particulates have been studied in the temperature range $-50^{\circ}C$ to $-50^{\circ}C$ The fillers used are both untreated and surface treated with stearic acid. The impact fracture toughness is evaluated from the impact energy absorbed divided by the uncut ligament area of the specimen. Impact fracture toughness increases as temperature is raised whether the fillers are coated or not. The static fracture toughness of these particular composites is evaluated based on the linear clastic fracture toughness of these particular composites is evaluated based on the linear clastic fracture mechanics. Static fracture toughess decreases with increasing temperature whether the fillers are coated or not. An extended stress whitened zone are observed through a large number of availabel sites for cavitation/debonding along particle matrix interface and matrix deformation.

  • PDF

Capacity Evaluation of Joint Reinforcement with Debonding Area at the Interface Steel to Concrete Surface (접합부 철근의 비부착에 따른 성능평가)

  • Jung, Woo-Young;Ha, Keum-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.67-70
    • /
    • 2011
  • 해안에 위치한 철근콘크리트 구조물 및 사회 간접 시설물들은 염해피해에 대한 우려가 있다. 염해피해로 인한 철근의 부식현상이 발생하면 철근과 콘크리트 부착성능의 저하로 인한 부재의 내력감소를 가져 올 수 있다. 따라서 본 연구에서는 염해부식이 진행되어 콘크리트와 철근간의 부착 및 비부착 여부에 따른 성능을 확인하기 위하여 완전 비부착된 보-기둥 접합부를 철근부착용 고무튜브를 이용하여 제작하였다. 제작된 실험체로 준정적 반복횡하중을 이용한 실험을 통해 성능평가를 수행하였다. 비부착된 보-기둥 접합부의 비선형 해석을 하기 위해 4절점 래티스 모델로 개선하여 적용하였다.

  • PDF

Evaluation of Optimized Application Rate of Emulsified Asphalt using Uniaxial Compression Test and Regression Analysis (일축압축시험 및 회기분석을 통한 아스팔트 유제의 최적 적용량 평가)

  • Kim, Dowan;Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.97-102
    • /
    • 2017
  • PURPOSES : Emulsified asphalt is critical for road construction. The objective of applying asphalt emulsion as an adhesive is to prevent the phenomenon of debonding between the upper and lower layers. The quantity and veriety of bituminous material can be varied according to the type of pavement and site conditions. The objective of this study is to reveal the optimum application rates of the emulsified asphalt materials by types of tack-coats using Interface Shear Strength(ISS). METHODS : In the research, emulsified asphalt was paved on the surface of the divided mixture. The specimens of paving asphalt emulsion were utilized to evaluate the bond strength of tack-coat materials. In the evaluation process, NCHRP Report 712 was utilized to investigate the Interface Shear Strength, which reflects the bond capacity of asphalt emulsion. Then, the optimum residual application rates by tack-coat types were determined using regression analysis. RESULTS :As a consequence of squared R values investigated from 0.7 to 1 as part of the regression analysis, the tendency of predicted ISS values was compared with the results. The optimum residual application rates of AP-3, RS(C)-4, QRS-4, and BD-Coat were determined to be $0.78{\ell}/m^2$, $0.51{\ell}/m^2$, $0.53{\ell}/m^2$, and $0.73{\ell}/m^2$, respectively, utilizing 4th regression analysis. CONCLUSIONS :Based on the result of this study, it was not feasible to conclude whether higher residual application of tack-coat material leads to improved bond capacity. Rather, the shearing strength varies depending on the type of pavement.

A COMPARISON OF SHEAR BOND STRENGTH OF VARIOUS ORTHODONTIC ADHESIVES (수종 교정용 접착제의 전단 접착강도 비교)

  • You, Mi-Hee;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.24 no.2
    • /
    • pp.433-445
    • /
    • 1994
  • Bonding of brackets is one of the essential factors for successful orthodontic treatment' so bond strength of orthodontic adhesives are very important. The purposes of this research were to compare shear bond strength of various orthodontic adhesives and to evaluate failure sites. One-hundred twenty extracted human first premolars were prepared for bonding and premolar brackets were bonded to prepared enamel surfaces with Super C Ortho, Mono-$Lok^2$, Transbond, and Super C Ortho after applying Fluorobond. After bonding of brackets, teeth specimens were divided into 3 groups. In group 1 specimens were stored at humidor $37^{\circ}C$ in 1 hour, in group 2 specimens were stored at humidor $37^{\circ}C$ in 24 hours, thermocycled 10 times and in group 3 specimens were stored at humidor $37^{\circ}C$ in 24 hours, thermocycled 1800 times. Then the universal testing machine Instron 6022, Instron Co., U.S.A. was used to test the shear bond strength of brackets to enamel. After debonding, brackets and enamel surfaces were examined under stereoscopic microscope to determine the failure sites The results were as follows : 1. Shear bond strength was significantly highest of using Super C Ortho after applying Fluorobond and Super C Ortho In group 1, was highest of using Super C Ortho in group 2, and was highest of using Mono-$Lok^2$ in group 3. 2. According to time and temperature change, in using Super C Ortho the group 2 had significantly highest strength and group 3 had lowest strength, in using Mono-$Lok^2$ the group 2 and had higher strength than group 1 and in using Super C Ortho after applying Fluorobond shear bond strength decreased constantly, 3. The failure sites were tooth-resin interface in Super C Ortho after applying Fluorobond, Mono $Lok^2$ and Transbond and were at almost same ratio bracket base-resin interface and tooth-resin interface in Super C Orth.

  • PDF

The Mechanical Properties and Biocompatibility of Functionally Graded Coatings(FGC) of Hydroxyapatite(HA) and Metallic Powders - Functionally Gradient Coatings of Thermal Spray in Air- (Hydroxyapatite (HA)와 금속 분말 경사 코팅의 기계적 특성 및 생체 적합성 - 대기 열용사 경사코팅 -)

  • Kim, Eun-Hye;Kim, Yu-Chan;Han, Seung-hee;Yang, Seok-Jo;Park, Jin-Woo;Seok, Hyun-Kwang
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.1
    • /
    • pp.13-20
    • /
    • 2009
  • This work presents functionally graded coatings (FGC) of hydroxyapatite (HA) and metallic powders on Ti-6Al-4V implants using plasma spray coating method. HA has been the most frequently used coating material due to its excellent compatibility with human bones. However, because of the abrupt changes in thermomechanical properties between HA and the metallic implant across an interface, and residual stress induced on cooling from coating temperture to room temperature, debonding at the interface occurs in use sometimes. In this work, FGC of HA and Ti or Ti-alloy powders is made to mitigate the abrupt property changes at the interface and the effect of FGC on residual stress release is investigated by evaluating the mechanical bond strength between the implant and the HA coating layers. Thermal annealing is done after coating in order to crystallize the HA coating layer which tends to have amorphous structure during thermal spray coating. The effects of types and compositional ratio of metallic powders in FGC and annealing conditions on the bond strength are also evaluated by strength tests and the microstructure analysis of coating layers and interfaces. Finally, biocompatibility of the coating layers are tested under ISO 10993-5.

Effect of ages and season temperatures on bi-surface shear behavior of HESUHPC-NSC composite

  • Yang Zhang;Yanping Zhu;Pengfei Ma;Shuilong He;Xudong Shao
    • Advances in concrete construction
    • /
    • v.15 no.6
    • /
    • pp.359-376
    • /
    • 2023
  • Ultra-high-performance concrete (UHPC) has become an attractive cast-in-place repairing material for existing engineering structures. The present study aims to investigate age-dependent high-early-strength UHPC (HESUHPC) material properties (i.e., compressive strength, elastic modulus, flexural strength, and tensile strength) as well as interfacial shear properties of HESUHPC-normal strength concrete (NSC) composites cured at different season temperatures (i.e., summer, autumn, and winter). The typical temperatures were kept for at least seven days in different seasons from weather forecasting to guarantee an approximately consistent curing and testing condition (i.e., temperature and relative humidity) for specimens at different ages. The HESUHPC material properties are tested through standardized testing methods, and the interfacial bond performance is tested through a bi-surface shear testing method. The test results quantify the positive development of HESUHPC material properties at the early age, and the increasing amplitude decreases from summer to winter. Three-day mechanical properties in winter (with the lowest curing temperature) still gain more than 60% of the 28-day mechanical properties, and the impact of season temperatures becomes small at the later age. The HESUHPC shrinkage mainly occurs at the early age, and the final shrinkage value is not significant. The HESUHPC-NSC interface exhibits sound shear performance, the interface in most specimens does not fail, and most interfacial shear strengths are higher than the NSC-NSC composite. The HESUHPC-NSC composites at the shear failure do not exhibit a large relative slip and present a significant brittleness at the failure. The typical failures are characterized by thin-layer NSC debonding near the interface, and NSC pure shear failure. Two load-slip development patterns, and two types of main crack location are identified for the HESUHPC-NSC composites tested in different ages and seasons. In addition, shear capacity of the HESUHPC-NSC composite develops rapidly at the early age, and the increasing amplitude decreases as the season temperature decreases. This study will promote the HESUHPC application in practical engineering as a cast-in-place repairing material subjected to different natural environments.

Analysis of Interfacial Shear Strength of Fiber/Epoxy Composites by Microbond Test and Finite Element Method (미소접합시험과 유한요소법을 통한 섬유/에폭시 복합재의 계면 전단강도 해석)

  • Kang, Soo-Keun;Lee, Deok-Bo;Choi, Nak-Sam
    • Composites Research
    • /
    • v.19 no.4
    • /
    • pp.7-14
    • /
    • 2006
  • Interfacial shear strength between epoxy and carbon fiber has been analyzed utilizing the microbond specimen with an epoxy micro-droplet adhered onto single carbon fiber. The interfacial shear stress distributions along the fiber/matrix interface were calculated by finite element analysis using three kinds of finite element models such as droplet model, circular-crosssection model and pull-out model. Conclusions were obtained as follows. (1) Interfacial shear stress distribution showed that larger stresses were concentrated in the fiber/matrix interface for microbond test than for pull-out test. Thus, debonding at the fiber/matrix interface during microbond test was liable to occur at low load level. (2) Microbond test showed higher interfacial strength which was caused by various effects of micro-droplet geometry and size as well as stress concentration in the region contacting with the micro-vise tip.

Curing Behavior and Interfacial Properties of Electrodeposited Carbon Fiber/Epoxy Composites by Electrical Resistivity Measurement under Tensile/Compressive Tests (전기증착된 탄소섬유/에폭시 복합재료의 인장/압축 하중하에서의 전기저항 측정법을 이용한 경화 및 계면특성)

  • Park, Joung-Man;Lee, Sang-Il;Kim, Jin-Won
    • Journal of Adhesion and Interface
    • /
    • v.2 no.1
    • /
    • pp.9-17
    • /
    • 2001
  • Curing behavior and interfacial properties were evaluated using electrical resistance measurement and tensile/compressive fragmentation test. Electrical resistivity difference (${\Delta}R$) during curing process was not observed in a bare carbon fiber. On the other hand, ${\Delta}R$ appeared due to the matrix contraction in single-carbon fiber/epoxy composite. Logarithmic electrical resistivity of the untreated single-carbon fiber composite increased suddenly to the infinity when the fiber fracture occurred under tensile loading, whereas that of the ED composite reached relatively broadly up to the infinity. Comparing to the untreated case, interfacial shear strength (IFSS) of the ED treated composite increased significantly in both tensile fragmentation and compressive Broutman test. Microfailure modes of the untreated and the ED treated fiber composite showed the debonding and the cone shapes in tensile test, respectively. For compressive test, fractures of diagonal slippage were observed in both untreated and the ED treated composite. Sharp-end shape fractures exhibited in the untreated composite, whereas relatively dull fractures showed in the ED Heated composite. It is proved that ED treatments affected differently on the interfacial adhesion and microfailure mechanism under tensile/compressive tests.

  • PDF

Interfacial Adhesion Properties of Oxygen Plasma Treated Polyketone Fiber with Natural Rubber (폴리케톤 섬유의 산소 플라즈마 처리에 따른 천연고무와의 계면접착 특성)

  • Won, Jong Sung;Choi, Hae Young;Yoo, Jae Jung;Choi, Han Na;Yong, Da Kyung;Lee, Seung Goo
    • Journal of Adhesion and Interface
    • /
    • v.13 no.1
    • /
    • pp.45-50
    • /
    • 2012
  • Recently developed polyketone fiber has various applications in the mechanical rubber goods as reinforcement because of its good mechanical properties. However, its surface is not suitable for good adhesion with the rubber matrix. Thus, a surface modification is essential to obtain the good interfacial adhesion. Plasma treatment, in this study, has been conducted to modify the surface of the polyketone fiber. The morphological changes of the fibers by oxygen plasma treatment were observed by using SEM and AFM. The chemical composition changes of PK fiber surface treated with oxygen plasma were investigated using an XPS (X-ray photoelectron spectroscopy). Finally, the effect of these changes on the interfacial adhesion between fiber and rubber was analyzed by using a microdroplet debonding test. By the plasma treatment, oxygen moieties on the fiber surface increased with processing time and power. The surface RMS roughness increases until the proper processing condition, but a long plasma processing time resulted in a rather reduced roughness because of surface degradation. When the treatment time and power were 60 s and 80 W, respectively, the highest interfacial shear strength (IFSS) was obtained between the PK fiber and natural rubber. However, as the treatment time and power were higher than 60 s and 80 W, respectively, the IFSS decreased because of degradation of the PK fiber surface by severe plasma treatment.

Adhesion Performance of UV-curable Debonding Acrylic PSAs with Different Thickness in Thin Si-wafer Manufacture Process (박막 실리콘 웨이퍼용 UV 경화형 Debonding 아크릴 점착제의 두께별 접착 물성)

  • Lee, Seung-Woo;Park, Ji-Won;Lee, Suk-Ho;Lee, Yong-Ju;Bae, Kyung-Rul;Kim, Hyun-Joong;Kim, Kyoung-Mahn;Kim, Hyung-Il;Ryu, Jong-Min
    • Journal of Adhesion and Interface
    • /
    • v.11 no.3
    • /
    • pp.120-125
    • /
    • 2010
  • UV-curable acrylic Pressure-sensitive adhesives (Acrylic PSAs) are used in many different parts in the world. A wafer manufacture process which is based on semiconductor industry is one thing. We have used acrylic PSAs whose thickness is different from $20{\mu}m$ to $30{\mu}m$ in wafer manufacture process so far. But as wafers become more thinner, acrylic PSAs are supposed to satisfy the requirements such as proper adhesion performance. The main purpose of this research is studying proper adhesion performance and UV-curing behavior of UV-curable acrylic PSAs with very thin thickness and then determining optimized conditions to raise the efficiency of thin wafer production. Acrylic PSAs contain 2-Ethylhexyl Acrylate (2-EHA), Acrylic Acid (AA) and Butyl Acrylate (BA). Ethyl acetate (EtAc) is used as solvent. The acrylic PSAs are obtained using solvent polymerization. Thickness of UV-curable acrylic PSAs is different from $10{\sim}30{\mu}m$. By peel strength and probe tack, adhesion performance and UV curing behavior of acrylic PSA are concerned.