• Title/Summary/Keyword: Interface Testing

Search Result 630, Processing Time 0.041 seconds

Design and Flight Test of Path Following System for an Unmanned Airship (무인 비행선의 자동 경로 추종 시스템 개발 및 비행시험)

  • Jung, Kyun-Myung;Sung, Jae-Min;Kim, Byoung-Soo;Je, Jeong-Hyeong;Lee, Sung-Gun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.5
    • /
    • pp.498-509
    • /
    • 2010
  • In this paper, a waypoint guidance law Line Tracking algorithm is designed for testing an Unmanned Airship. In order to verify, we develop an autonomous flight control and test system of unmanned airship. The flight test system is composed FCC (Flight Control Computer), GCS (Ground Control System), Autopilot & Guidance program, GUI (Graphic User Interface) based analysis program, and Test Log Sheet for the management of flight test data. It contains flight test results of single-path & multi-path following, one point continuation turn, LOS guidance, and safe mode for emergency.

An on-line non-invasive network monitor for the SPAX parallel computer (SPAX 병렬 컴퓨터에서의 온라인 무간섭 네트워크 성능 감시기)

  • 이승구
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.6
    • /
    • pp.44-50
    • /
    • 1997
  • This paper describes the design and test of an on-line non-invasive network performance monitor (hardware portion) for the SPAX parallel computer. The SPAX parallel computer supports up to 256 intel P6 processors with 4 P6 processors constituting a processign node. The nodes are interconnected with a dual two-level crossbar network calle dXcent-net. Since the performance of the SPAX parallel computer is highly dependent on the proper and efficient operation of the network, an on-line non-invasive network performance monitor (with hardware components) has been developed to aid in the monitoring and tunign of the Xcent-net. Successful testing of a prototype node monitor board and PC interface system shows that our monitor design provides a low-cost practical solution to this problem.

  • PDF

Effect of hygrothermal aging on GFRP composites in marine environment

  • Garg, Mohit;Sharma, Shruti;Sharma, Sandeep;Mehta, Rajeev
    • Steel and Composite Structures
    • /
    • v.25 no.1
    • /
    • pp.93-104
    • /
    • 2017
  • In the present work, the effect of hygrothermal aging on the glass fibre and epoxy matrix interface has been investigated by destructive and non-destructive techniques. The glass fiber reinforced polymer (GFRP) composite laminates were prepared using Vacuum Assisted Resin Infusion Molding (VARIM) technique and the specimens were immersed in simulated seawater, followed by quantitative measurement. Besides this, the tensile tests of GFRP specimens revealed a general decrease in the properties with increasing aging time. Also, exposed specimens were characterized by a non-destructive ultrasonic guided Lamb wave propagation technique. The experimental results demonstrate a correlation between the drop in ultrasonic voltage amplitude and fall in tensile strength with increasing time of immersion. Hence, the comparison of the transmitted guided wave signal of healthy vis-a-vis specimens subjected to different extents of hygrothermal aging facilitated performance evaluation of GFRP composites.

Development of an Intelligent Station HMI in IEC 61850 Based Substation

  • Rim, Seong-Jeong;Zeng, Sheng-Wu;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • Because the existing Human-Machine Interface (HMI) for the conventional substation cannot dynamically indicate the configuration information of the Substation Automation System (SAS). In this paper, an intelligent station HMI is proposed for IEC 61850 based substation. The program of the proposed HMI not only can automatically generate the layout of single line diagram, but can also indicate the communication network and functions of IEDs by reading SCL files. It greatly helps monitor the operation status, communication network and each IED dynamically, such as failure detection in SAS. Furthermore, this paper presents the possibility of developing new software for SAS with the full use of IEC 61850-6. Once the software is complete, there is no need to change it when the substation is upgraded or when it is migrated to other IEC 61850 based substations, which is a cost-effective solution.

A Study of Inspection Module for Verifying Reliability on Railway Vehicle (철도차량 검측모듈의 신뢰성 검증 시험 연구)

  • Na, Kyung-min;Park, Young;Kwon, Sam-young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1155-1161
    • /
    • 2017
  • This study examines environmental performance of the arcing measurement module according to international standards. The module assesses the collected current performance using a computer system. The module is required to assess environmental impact resulting from electromagnetic waves, shock and temperature change during train operation. The test includes testing EMI/EMC, vibration, shock and temperature cycling for interface between trains and the arcing measurement module. The module test items were determined in compliance with the standards suggested by the International Electrotechnical Commission (IEC) and Europaische Norm (EN). This study describes the method of test, test equipment operation and how to choose relevant performance standards. The analysis and test results of environmental performance for the module based on computer system are described in this study.

ABR Service Provision in ATM-LAN Consisting of ATM Routers and Switches (ATM 라우터와 스위치로 구성되는 ATM-LAN에서의ABR 서비스 제공)

  • 이숭희;이준원
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.1
    • /
    • pp.125-131
    • /
    • 1998
  • We propose a structure for implementation to provide ABR service in ATM-LAN consisting of ATM routers and ATM switches. ATM routers are constructed by installing ATM interface block with ABR capability for this purpose. The structure for EFCI, the basic function in ATM switches to support ABR service, is also proposed. Finally the testing procedure after implementation is provided to verify the conformity of the implemented systems.

  • PDF

Development of DCSWGR for AGT Light Rail Power Supply System (AGT 경량전철 전력공급용 직류배전반 개발)

  • JEON Y.J.;KIM S.N.;BAEK B.S.;KIM J.H.;LEE H.D.;KWON J.L.;JUNG S.G.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1391-1393
    • /
    • 2004
  • This paper described the development of technology for LRT (Light Rail Transit) power system, which are sponsored by MOCT and supervised by KRRI. Especially, manufacture, interface between components and composition for DC Switchgear are focused. Most main components for DC switchgear(Protective Relay, HSCB, DS) are made by own. Also the type test report of international testing laboratory about the DC Switchgear based on IEC regulations is introduced. Finally the product will be proved based on field test.

  • PDF

Analysis of Current Collection Performance Testing and Result of 350[km/h] Catenary System (350km/h 전차선로 집전성능 시험 및 결과 분석)

  • Heo, Yong-Seok;Lee, In-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.365-369
    • /
    • 2016
  • The 350[km/h] catenary system was successfully opened in Honam high speed line. This 350[km/h] catenary system is firstly constructed in South Korea. Therefore the current collection performance of this system should be tested and evaluated by the authority. This paper describes the testings by running of HEMU-430X train and the evaluation criteria and result analysis to determine whether the performance of the catenary is good or not as a verification of catenary-pantograph interface. In detail, the contact force by pantograph, arcs by loss of contact and uplift amount of the catenary support were measured and discussed as a category of the current collection performance.

A Large Scale Smart-Grid field-test in Jeju (제주 Smart-Grid 대규모 실증단지 구축 현황)

  • NamKoong, Won;Ha, Bok-Nam;Lee, Sung-Woo;Seo, In-Yong;Jang, Moon-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Five smart grid projects was started with large scale at Jeju Island in South Korea from 2009, and smart-grid test-bed was started in Nov. 2010. The five projects are Smart Power Grid (SPG), Smart Renewable (SR), Smart Transportation (ST), Smart Place (SP) and Smart Electric Service (SES). Korea government constructed the smart grid public relations center at Nov. 2010 in Jeju Island and there will be continued the field operation and interface testing among five smart gird projects until May. 2013.

Sliding Wear Characteristics of High Speed Steel by Powder Metallurgy under several Testing Temperature (분말고속도공구강의 작동온도에 따른 미끄럼마모특성해석)

  • 이한영;노정균;배종수;김용진
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.135-140
    • /
    • 2001
  • In metal cutting at the tool-chip interface, friction generates considerable amount of heat. Thus, tile .knowledge of wear properties or the cutting tool material in high temperature has been known as one of tile important factors in need of clarification. The authors presented the wear properties of 5%V-5%Co-1%Nb high speed steel, fabricated by powder metallurgy, in room temperature in a previous article. The objective of this paper is to clarify tile effects of temperature ell its wear properties. Wear tests in sliding conditions under various temperatures have been conducted. The results indicate that tile wear properties of tile tool material in high temperature as well as in room temperature are excellent. It may be deduced that the oxide layer formed on the vol-n surface at high temperature is stable enough to prevent wear due to tile high temperature strength of its matrix.

  • PDF