• Title/Summary/Keyword: Interface Failure

Search Result 738, Processing Time 0.028 seconds

Development of Reliability Simulator for Electronic Components (전자부품 통합 신뢰성 Simulator 개발)

  • Kim, Wan-Doo;Lee, Seung-Woo;Han, Seung-Woo;Osterman, Michael
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1749-1753
    • /
    • 2007
  • The reliability, that is Long-Term Quality, require an approaching different from Short-Term Quality which is used before. As the electronic components are able to be easily normalized on the reliability testing, various testing standards are used. In this study, we proposed two reliability simulator that is PoF(Physics of Failure)-based and failure rate models-based. PoF-based simulator is introduced based on CalceEP program that is created by University of Maryland. This simulator can be modified by user interface of properties and PoF models and operated on stand alone system. Failure rate models-based simulator introduced according to analyzing reliability prediction documents. Also, unified database including failure data models is built from existing MIL-HDBK-217F N2, PRISM, and Bellcore, and web-based simulator is developed. The developed reliability simulator will service of the PoF model, properties, failure rate model accumulated and its data by web and internet.

  • PDF

A COMPARISON OF SHEAR BOND STRENGTH OF VARIOUS ORTHODONTIC ADHESIVES (수종 교정용 접착제의 전단 접착강도 비교)

  • You, Mi-Hee;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.24 no.2
    • /
    • pp.433-445
    • /
    • 1994
  • Bonding of brackets is one of the essential factors for successful orthodontic treatment' so bond strength of orthodontic adhesives are very important. The purposes of this research were to compare shear bond strength of various orthodontic adhesives and to evaluate failure sites. One-hundred twenty extracted human first premolars were prepared for bonding and premolar brackets were bonded to prepared enamel surfaces with Super C Ortho, Mono-$Lok^2$, Transbond, and Super C Ortho after applying Fluorobond. After bonding of brackets, teeth specimens were divided into 3 groups. In group 1 specimens were stored at humidor $37^{\circ}C$ in 1 hour, in group 2 specimens were stored at humidor $37^{\circ}C$ in 24 hours, thermocycled 10 times and in group 3 specimens were stored at humidor $37^{\circ}C$ in 24 hours, thermocycled 1800 times. Then the universal testing machine Instron 6022, Instron Co., U.S.A. was used to test the shear bond strength of brackets to enamel. After debonding, brackets and enamel surfaces were examined under stereoscopic microscope to determine the failure sites The results were as follows : 1. Shear bond strength was significantly highest of using Super C Ortho after applying Fluorobond and Super C Ortho In group 1, was highest of using Super C Ortho in group 2, and was highest of using Mono-$Lok^2$ in group 3. 2. According to time and temperature change, in using Super C Ortho the group 2 had significantly highest strength and group 3 had lowest strength, in using Mono-$Lok^2$ the group 2 and had higher strength than group 1 and in using Super C Ortho after applying Fluorobond shear bond strength decreased constantly, 3. The failure sites were tooth-resin interface in Super C Ortho after applying Fluorobond, Mono $Lok^2$ and Transbond and were at almost same ratio bracket base-resin interface and tooth-resin interface in Super C Orth.

  • PDF

Mechanical behaviour between adjacent cracks in CFRP plate reinforced RC slabs

  • Yuan, Xin;Bai, Hongyu;Sun, Chen;Li, Qinqing;Song, Yanfeng
    • Structural Engineering and Mechanics
    • /
    • v.84 no.3
    • /
    • pp.375-391
    • /
    • 2022
  • This paper discussed and analyzed the interfacial stress distribution characteristic of adjacent cracks in Carbon Fiber Reinforced Polymer (CFRP) plate strengthened concrete slabs. One un-strengthened concrete test beam and four CFRP plate-strengthened concrete test beams were designed to carry out four-point flexural tests. The test data shows that the interfacial shear stress between the interface of CFRP plate and concrete can effectively reduce the crack shrinkage of the tensile concrete and reduces the width of crack. The maximum main crack flexural height in pure bending section of the strengthened specimen is smaller than that of the un-strengthened specimen, the CFRP plate improves the rigidity of specimens without brittle failure. The average ultimate bearing capacity of the CFRP-strengthened specimens was increased by 64.3% compared to that without CFRP-strengthen. This indicites that CFRP enhancement measures can effectively improve the ultimate bearing capacity and delay the occurrence of debonding damage. Based on the derivation of mechanical analysis model, the calculation formula of interfacial shear stress between adjacent cracks is proposed. The distributions characteristics of interfacial shear stress between certain crack widths were given. In the intermediate cracking region of pure bending sections, the length of the interfacial softening near the mid-span cracking position gradually increases as the load increases. The CFRP-concrete interface debonding capacity with the larger adjacent crack spacing is lower than that with the smaller adjacent crack spacing. The theoretical calculation results of interfacial bonding shear stress between adjacent cracks have good agreement with the experimental results. The interfacial debonding failure between adjacent cracks in the intermediate cracking region was mainly caused by the root of the main crack. The larger the spacing between adjacent cracks exists, the easier the interfacial debonding failure occurs.

Finite Element Analysis of Reinforced Earth Wall Behavior (보강토 옹벽의 거동에 관한 유한요소 해석)

  • 최인석;장연수;조광철
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.805-812
    • /
    • 2003
  • The purpose of this study is to evaluate the behavior of a reinforced earth wall by modeling the properties of the interface between soil and reinforced elements as well as the non-linear stress-strain characteristics of soil. The effect of lateral earth pressures induced during construction is also included in the analyses. The interface element used to evaluate the relative movement of the interface between soil/reinforcement and soil/wall- facing has a zero thickness and essentially consists of normal and shear springs. The behavior of soil element is calculated based on the hyperbolic model. The computer program SSCOMPPC which includes the interface element, hyperbolic model and bi-linear model is applied in this study. From the analyses, it is showed that the locus of maximum tension were closed to the hi-linear failure line of theoretical analyses. The lateral displacement of SSCOMPPC is larger than that of the FLAC which adopts the elastic model. This means the analysis which is adopted the hyperbolic model and interface element induced more larger displacement.

  • PDF

Analysis of Failure Mode of Geotextile Container for Urgent Rehabilitation of Railroad Bed (철도노반 긴급복구를 위한 토목섬유 컨테이너의 파괴형태 분석)

  • 신은철;이명호;이준철
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.608-613
    • /
    • 2002
  • This study was under taken as an analysis of failure mode in a railroad bed reconstructed with miniaturized Geotextile Container after being destroyed by heavy rain. It assesses the practical use of the bag shaped Geotextile Container method in the rehabilitation of destroyed roadbeds. The failure mode was assessed using the laboratory model tests to determine the following criteria: Strain of Geotextile Container, Vertical & Horizontal displacements of Geotextile Container layer, and the transmitting load effects due to the applied load. The Geotextile Container layer was failed as a Block Failure type, although there was some variation in the results between the saturated and unsaturated conditions. The main failure was caused by the reduction of the interface friction between Geotextile Containers. The result of this mobilizes the significant horizontal displacement and the ultimate failure of the Geotextile Container layer. The strain on the wet Geotextile Container was occurred about two times greater than that of dry condition.

  • PDF

A Study on the Stability Evaluation and Numerical Simulation of Toppling Failure on a Cut-Slope (절토사면의 전도파괴에 대한 안정성 평가 및 수치해석적 고찰)

  • Choi, Ji-Yong;Kim, Seung-Hyun;Koo, Ho-Bon
    • The Journal of Engineering Geology
    • /
    • v.20 no.1
    • /
    • pp.13-23
    • /
    • 2010
  • Toppling failure of a slope is defined as failure behavior accompanying the rotation of rock block which is different from other failure such as sliding along with discontinuities and so on. It generally occurs in the region that discontinuities were developed with inverse dip direction to a slope and it could play a critical role in judging stability of slope. In this study, the stability evaluation was performed about toppling failure on a jointed road cut-slope. To check the deformation behavior, numerical analysis is widely used. However common analysis programs are based on continuum model. Recently, many methods that discontinuity properties can be considered in continuum analysis are suggested. In this study, numerical analysis based on FEM(Finite Element Method) was performed using interface element applied in heterogeneous boundary to simulate effects of discontinuities.

Experimental study on damage and debonding of the frozen soil-concrete interface under freeze-thaw cycles

  • Liyun Tang;Yang Du;Liujun Yang;Xin Wang;Long Jin;Miaomiao Bai
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.663-671
    • /
    • 2023
  • Freeze-thaw cycles induce strength loss at the frozen soil-concrete interface and deterioration of bonding, which causes construction engineering problems. To clarify the deterioration characteristics of the interface under the freeze-thaw cycle, a frozen soil-concrete sample was used as the research object, an interface scanning electron microscope test under the freeze-thaw cycle was carried out to identify the micro index information, and an interface shear test was carried out to explore the loss law of interface shear strength under the freeze-thaw cycle. The results showed that the integrity of the interface was destroyed, and the pore number and pore size of the interface increased significantly with the number of freeze-thaw cycles. The connection form gradually deteriorates from surface-to-surface contact to point-to-surface contact and point-to-point contact, and the interfacial shear strength decreases the most at 0-3 freeze-thaw cycles, with small decreases from to 3-8 cycles. After 12 freeze-thaw cycles, the interfacial shear strength tends to be stable, and shear the failure occurs internally in the soil.

Effect Evaluation of Hole Defects in Adhesive on SIF of Interface Crack (접착층내 결함이 계면균열의 응력확대계수에 미치는 영향 평가)

  • Hyun, Cheol-Seung;Heo, Sung-Pil;Yang, Won-Ho;Ryu, Myung-Hae
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.299-303
    • /
    • 2001
  • Adherend-adhesive interface failure will occur on a macroscale when surface preparation or material quality are poor. It is well known that the stress singularity occurs at the edges of interface between the adhernds and the adhesive, and that crack will initiate from these positions. Also if bubbles are created and remained in the adhesive layer during the bonding process, the stress concentrates around these hole defects. In this paper, the effects of the hole defects on the SIF of interface crack were examined. From results, SIF increased with the hole defects near the interface crack and increased with an decreae in the upper adherend thickness, an increase in the center adhesive thickness.

  • PDF

A study on analysis of interfacial breakdown properties with variable temperalure in straight cable Joint modeling EPGXY/EPOM interface (온도에 따른 케이블 직선 접속재 모델링 EPOXY/EPDM 계면의 파괴 특성에 관한 연구)

  • 배덕권;정인재;김상걸;정일형;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.532-535
    • /
    • 1999
  • In power cable joints, the interfaces of two different dielectric materials are inevitable. In addition, the interfacial breakdown between two internal dielectric surfaces represents one of the major causes of failure for power cable joints. We chose epoxy/EPDM interface, one of the interface in cable joints, and investigate dielectric interfacial breakdown phenomenon. First, design specimen with Flux 2D. Second, find interface condition which has high dielectric strength. Third, investigate interfacial breakdown properties with variable temperature.

  • PDF

Bearing capacity of foundation on rock mass depending on footing shape and interface roughness

  • Alencar, Ana S.;Galindo, Ruben A.;Melentijevic, Svetlana
    • Geomechanics and Engineering
    • /
    • v.18 no.4
    • /
    • pp.391-406
    • /
    • 2019
  • The aim of this paper was to study the influence of the footing shape and the effect of the roughness of the foundation base on the bearing capacity of shallow foundations on rock masses. For this purpose the finite difference method was used to analyze the bearing capacity of various types and states of rock masses under the assumption of Hoek-Brown failure criterion, for both plane strain and axisymmetric model, and considering smooth and rough interface. The results were analyzed based on a sensitivity study of four varying parameters: foundation width, rock material constant (mo), uniaxial compressive strength and geological strength index. Knowing how each parameter influences the bearing capacity depending on the footing shape (circular vs strip footing) and the footing base interface roughness (smooth vs rough), two correlation factors were developed to estimate the percentage increase of the ultimate bearing capacity as a function of the footing shape and the roughness of the footing base interface.