• 제목/요약/키워드: Interface Failure

검색결과 738건 처리시간 0.027초

시효와 열순환 처리가 수복용 복합레진의 인장강도에 미치는 영향 (An Effect of Aging and Thermocycling on the Tensile Strength of Restorative Composite Resins)

  • 이미정;유미경;이광원
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.15-23
    • /
    • 2005
  • The purpose of this study was to evaluate effect of aging and thermocycling on the tensile strength of restorative composite resins. Eight commercially available light-cured restorative composites (Heliomolar: HM, Palfique Estelite: PE, Spectrum: ST, UniFil-F: UF, Z100: ZH, Clearfil AP-X: CA, P60: PS, and Palfique Toughwell: PT) were selected as experimental materials. Rectangular-shaped tensile test specimens were fabricated in a teflon mold giving 5 mm in gauge length and 2 mm in thickness. All samples were stored in distilled water at $37^{\circ}C$ for 100 days. Every 10 days, specimens were thermocycled for 1,000 cycles with 15 seconds of dwelling time in each $5^{\circ}C$ and $55^{\circ}C$ water baths. Tensile testing was carried out at a crosshead speed of 0.5 mm/min and fracture surfaces were observed with a scanning electron microscope. The results obtained were summarized as follows; 1. The strength degradation of thermocycled group was severer than that of the aged group (P<0.01). 2. The tensile strength of the CA and ST groups were significantly higher than that of other groups after thermocycling treatment (P<0.05). 3. Fracture surfaces showed that the composite resin failure developed along the matrix and the filler/resin interface region.

Tobacco Use and Quit Behaviour Assessment in the Global Adult Tobacco Survey (GATS): Invalid Responses and Implications

  • Jena, Pratap Kumar;Kishore, Jugal;Pati, Sanghamitra;Sarkar, Bidyut Kanti;Das, Sagarika
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권11호
    • /
    • pp.6563-6568
    • /
    • 2013
  • Background: Tobacco use and quit attempts are two key indicators of the Global Adult Tobacco Survey (GATS) that assess quit attempts among current as well as former tobacco users. The relevant data have inherent policy implications for tobacco cessation programme evaluation. This study aimed to review the concepts of quit attempt assessment and quantifying invalid responses considering GATS-India data. Materials and Methods: GATS assessment of tobacco use and quit attempts were examined in the current literature. Two categories of invalid responses were identified by stratified analysis of the duration of last quit attempt among current users and duration of abstinence among former users. Category A included absolute invalid responses when time-frame of assessment of current tobacco use and less than former tobacco use were violated. Category B included responses that violated the unit of measurement of time. Results: Current daily use, current less than daily use and former use in GATS were imprecisely defined with overlapping of time-frame of assessment. Overall responses of 3,102 current smokers, 4,036 current smokeless users, 1,904 former smokers and 1,343 former smokeless users were analyzed to quantify invalid responses. Analysis indicated overall 21.2% (category A: 7.32%; category B: 17.7%) and 22.7% (category A: 8.05%; category B: 18.1%) invalid responses among current smokers and smokeless users respectively regarding their duration of last quit attempt. Similarly overall 6.62% (category A: 4.7%; category B: 2.3%) and 10.6% (category A: 8.6%; category B: 3.5%) invalid responses were identified among former smokers and smokeless users respectively regarding their duration of abstinence. Conclusions: High invalid responses for a single assessment are due to the imprecise definition of current use, former use and quit attempt; and failure to utilize opportunity of direct data entry interface use during the survey to validate responses instantly. Redefining tobacco use and quit attempts considering an appropriate timeframe would reduce invalid responses.

미끄럼 속도 변화에 따른 폴리우레탄 씰의 마모 특성 (Effect of Sliding Speed on Wear Characteristics of Polyurethane Seal)

  • 김한솔;전홍규;정구현
    • Tribology and Lubricants
    • /
    • 제34권2호
    • /
    • pp.49-54
    • /
    • 2018
  • Hydraulic reciprocating seal has been widely used to prevent fluid leakage in hydraulic systems. Also, hydraulic reciprocating seal plays a significant role to provide lubricant film at contacting interface to minimize tribological problems due to sliding with counter material. To predict lifetime of hydraulic reciprocating seal, quantitative understanding of wear characteristics with respect to operating conditions such as normal force and sliding speed is needed. In this work, effect of sliding speed on wear of polyurethane (PU) hydraulic reciprocating seal were experimentally investigated using a pin-on-disk tribo-tester. The wear characteristics of PU specimens were quantitatively determined by comparing the confocal microscope data before and after test. It was found that the wear rate of PU specimens decreased from $4.9{\times}10^{-11}mm^3$ to $1.1{\times}10^{-11}mm^3/Nm$ as sliding speed increased from 120 mm/s to 940 mm/s. Also, it was observed that the friction decreased slightly as the sliding speed increased. Improvement of lubrication state with increasing sliding speed was likely to be responsible for this enhanced friction and wear characteristics. This result also suggests that decrease in sliding distance between PU elastomer and counter materials at lower sliding speed is preferred. Furthermore, the quantitative assessment of wear characteristics of PU specimen may be useful in prediction of lifetime of PU hydraulic reciprocating seal if the allowed degree of wear for failure of the seal is provided.

Immersion Ag가 도금된 Cu기판을 가진 Pb-free solder 접합부의 신뢰성 평가 (Reliability evaluation of Pb-free solder joint with immersion Ag-plated Cu substrate)

  • 윤정원;정승부
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년도 춘계 학술대회 개요집
    • /
    • pp.30-32
    • /
    • 2006
  • The interfacial reaction and reliability of eutectic Sn-Pb and Pb-free eutectic Sn-Ag ball-grid-array (BGA) solders with an immersion Ag-plated Cu substrate were evaluated following isothermal aging at $150^{\circ}C$. During reflowing, the topmost Ag layer was dissolved completely into the molten solder, leaving the Cu layer exposed to the molten solder for both solder systems. A typical scallop-type Cu-Sn intermetallic compound (IMC) layer was formed at both of the solder/Cu interfaces during reflowing. The thickness of the Cu-Sn IMCs for both solders was found to increase linearly with the square root of isothermal aging time. The growth of the $Cu_3Sn$ layer for the Sn-37Pb solder was faster than that for the Sn-3.5Ag solder, In the case of the Sn-37Pb solder, the formation of the Pb-rich layer on the Cu-Sn IMC layer retarded the growth of the $Cu_6Sn_5$ IMC layer, and thereby increased the growth rate of the $Cu_3Sn$ IMC layer. In the ball shear test conducted on the Sn-37Pb/Ag-plated Cu joint after aging for 500h, fracturing occurred at the solder/$Cu_6Sn_5$ interface. The shear failure was significantly related to the interfacial adhesion strength between the Pb-rich and $Cu_6Sn_5$ IMC layers. On the other hand, all fracturing occurred in the bulk solder for the Sn-3.5Ag/Ag-plated Cu joint, which confirmed its desirable joint reliability.

  • PDF

은(Ag)계 활성금속을 사용한 질화 알미늄(AlN)과 Cu의 브레이징 (Brazing of Aluminium Nitride(AlN) to Copper with Ag-based Active Filler Metals)

  • 허대;김대훈;천병선
    • Journal of Welding and Joining
    • /
    • 제13권3호
    • /
    • pp.134-146
    • /
    • 1995
  • Aluminium nitride(AlN) is currently under investigation as potential candidate for replacing alumium oxide(Al$_{2}$ $O_{3}$) as a substrate material for for electronic circuit packaging. Brazing of aluminium nitride(AlN) to Cu with Ag base active alloy containing Ti has been investigated in vacuum. Binary Ag$_{98}$ $Ti_{2}$(AT) and ternary At-1wt.%Al(ATA), AT-1wt.%Ni(ATN), AT-1wt.% Mn(ATM) alloys showed good wettability to AlN and led to the development of strong bond between brate alloy and AlN ceramic. The reaction between AlN and the melted brazing alloys resulted in the formation of continuous TiN layers at the AlN side iterface. This reaction layer was found to increase by increase by increasing brazing time and temperature for all filler metals. The bond strength, measured by 4-point bend test, was increased with bonding temperature and showed maximum value and then decreased with temperature. It might be concluded that optimum thickness of the reaction layer was existed for maximum bond strength. The joint brazed at 900.deg.C for 1800sec using binary AT alloy fractured at the maximum load of 35kgf which is the highest value measured in this work. The failure of this joint was initiated at the interface between AlN and TiN layer and then proceeded alternately through the interior of the reaction layer and AlN ceramic itself.

  • PDF

무전해 Ni-P 두께와 Assembly Process가 Solder Ball Joint의 신뢰성에 미치는 영향 (Effects of the Electroless Ni-P Thickness and Assembly Process on Solder Ball Joint Reliability)

  • 이지혜;허석환;정기호;함석진
    • Journal of Welding and Joining
    • /
    • 제32권3호
    • /
    • pp.60-67
    • /
    • 2014
  • The ability of electronic packages and assemblies to resist solder joint failure is becoming a growing concern. This paper reports on a study of high speed shear energy of Sn-4.0wt%Ag-0.5wt%Cu (SAC405) solder with different electroless Ni-P thickness, with $HNO_3$ vapor's status, and with various pre-conditions. A high speed shear testing of solder joints was conducted to find a relationship between the thickness of Ni-P deposit and the brittle fracture in electroless Ni-P deposit/SAC405 solder interconnection. A focused ion beam (FIB) was used to polish the cross sections to reveal details of the microstructure of the fractured pad surface with and without $HNO_3$ vapor treatment. A scanning electron microscopy (SEM) and an energy dispersive x-ray analysis (EDS) confirmed that there were three intermetallic compound (IMC) layers at the SAC405 solder joint interface: $(Ni,Cu)_3Sn_4$ layer, $(Ni,Cu)_2SnP$ layer, and $(Ni,Sn)_3P$ layer. The high speed shear energy of SAC405 solder joint with $3{\mu}m$ Ni-P deposit was found to be lower in pre-condition level#2, compared to that of $6{\mu}m$ Ni-P deposit. Results of focused ion beam and energy dispersive x-ray analysis of the fractured pad surfaces support the suggestion that the brittle fracture of $3{\mu}m$ Ni-P deposit is the result of Ni corrosion in the pre-condition level#2 and the $HNO_3$ vapor treatment.

Tensile Properties of Fiber Reinforced Concrete

  • Cho, Baik-Soon;Back, Sung-Yong;Park, Hyun-Jung
    • KCI Concrete Journal
    • /
    • 제12권2호
    • /
    • pp.85-93
    • /
    • 2000
  • Potentially significant mechanical improvements in tension can be achieved by the incorporation of randomly distributed, short discrete fibers in concrete. The improvements due to the incorporation fibers significantly influence the composite stress - strain ($\sigma$-$\varepsilon$) characteristics. In general incorporating fibers in a plain concrete has relatively small effect on its precracking behavior. It, however, alters its post-cracking behavior quite significantly, resulting in greatly improved ductility, crack controls, and energy absorption capacity (or toughness). Therefore, a thorough understanding the complete tensile stress - strain ($\sigma$-$\varepsilon$) response of fiber reinforced concrete is necessary for proper analysis while using structural components made with fiber reinforced concrete. Direct tensile stress applied to a specimen is in principle the simplest configuration for determining the tensile response of concrete. However, problems associated with testing brittle materials in tension include (i) the problem related to gripping of the specimen and (ii) the problem of ensuring centric loading. Routinely, indirect tension tests for plain concrete, flexural and split-cylinder tests, have been used as simpler alternatives to direct uniaxial tension test. They are assumed to suitable for fiber reinforced concrete since typically such composites comprise 98% by volume of plain concrete. Clearly since the post-cracking characteristics are significantly influenced by the reinforcing parameters and interface characteristics, it would be fundamentally incorrect to use indirect tensile tests for determining the tensile properties of fiber reinforced concrete. The present investigation represents a systematic look at the failure and toughening mechanisms and macroscopic stress - strain ($\sigma$-$\varepsilon$) characteristics of fiber reinforced concrete in the uniaxial tension test. Results from an experimental parametric study involving used fiber quantity, type, and mechanical properties in the uniaxial tension test are presented and discussed.

  • PDF

Influence of cement thickness on resin-zirconia microtensile bond strength

  • Lee, Tae-Hoon;Ahn, Jin-Soo;Shim, June-Sung;Han, Chong-Hyun;Kim, Sun-Jai
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.119-125
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the influence of resin cement thickness on the microtensile bond strength between zirconium-oxide ceramic and resin cement. MATERIALS AND METHODS. Thirty-two freshly extracted molars were transversely sectioned at the deep dentin level and bonded to air-abraded zirconium oxide ceramic disks. The specimens were divided into 8 groups based on the experimental conditions (cement type: Rely X UniCem or Panavia F 2.0, cement thickness: 40 or 160 ${\mu}m$, storage: thermocycled or not). They were cut into microbeams and stored in $37^{\circ}C$ distilled water for 24 h. Microbeams of non-thermocycled specimens were submitted to a microtensile test, whereas those of thermocycled groups were thermally cycled for 18,000 times immediately before the microtensile test. Three-way ANOVA and Sheffe's post hoc tests were used for statistical analysis (${\alpha}$=95%). RESULTS. All failures occurred at the resin-zirconia interface. Thermocycled groups showed lower microtensile bond strength than non-thermocycled groups (P<.001). Differences in cement thickness did not influence the resin-zirconia microtensile bond strength given the same resin cement or storage conditions (P>.05). The number of adhesive failures increased after thermocycling in all experimental conditions. No cohesive failure was observed in any experimental group. CONCLUSION. When resin cements of adhesive monomers are applied over air-abraded zirconia restorations, the degree of fit does not influence the resin-zirconia microtensile bond strength.

CNT-폴리프로필렌 복합재료의 기계적 물성평가 및 전기 미세평가법을 이용한 손상감지 (Evaluation of Mechanical Properties and Damage Sensing of CNT-Polypropylene Composites by Electro-Micromechanical Techniques)

  • 왕작가;권동준;구가영;김학수;김대식;이춘수;박종만
    • Composites Research
    • /
    • 제26권1호
    • /
    • pp.1-6
    • /
    • 2013
  • 용액 분산법을 이용하여 CNT를 균질하게 분산시켰고, CNT-폴리프로필렌 복합재료 제조를 위해 압출기와 사출기를 사용하였다. CNT 고유의 전도성을 기반으로 CNT-PP 복합재료의 내부 손상을 감지하기 위해 전기저항 측정법을 이용하였다. CNT-PP의 기계적 및 계면 물성을 확인하고 일반 PP와 비교하였다. CNT의 강화 효과로 인하여 CNT를 함유함으로서, PP 기지의 기계적 물성은 더 증가되는 경향을 확인하였다. CNT-PP 복합재료의 내부 손상을 평가하기 위해 파괴 및 굴곡실험을 진행하며, 동시에 발생되는 전기저항 변화도를 감지하여 미세손상을 평가하였다. CNT 강화제의 첨가는 좋은감지능을 보여주었다. 낮은 CNT 함유율임에도 CNT-PP 복합재료의 감지가 가능했으며, 반복 하중 실험 중 최대 임계 응력을 확인하여, 내부에 발생된 미세 파괴를 찾아 낼 수 있었다.

UV경화수지의 고형상비 미세패턴 이형에 관한 연구 (A study on releasing high aspect ratio micro features formed with a UV curable resin)

  • 권기환;유영은;김창완;박영우;제태진;최두선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1833-1836
    • /
    • 2008
  • Recently as the micro surface features become higher and diverse in their shapes, the releasing of the molded features becomes more crucial for manufacturing of the micro patterned products. The higher aspect ratio of the features or more complex shape of the features results in larger releasing force, elongation or cohesive failure of the features during the releasing. Another issue would be the uniformity of the released surface features after molding, especially for applications with large area surface. The micro patterned optical film, one of typical applications for micro surface features, consists of two layers, the thermoplastic base film and the micro formed UV resin layer. Therefore two interfaces are typically involved during the forming of this micro featured film; one is between the base film and the UV resin and another is between the resin and the pattern master. To improve the releasing of the molded surface features, the adhesive characteristic was investigated at these two interfaces. A PET film was used as a base film and two UV curable resins with different surface energy were prepared for different adhesiveness. Also the two different pattern masters were employed; one is made from brass-copper alloy and fabricated with PMMA. The adhesiveness at each interface was measured for some combinations of these base film, UV resins and the masters and the effect of this adhesiveness on the releasing was investigated.

  • PDF