• Title/Summary/Keyword: Inter-day variation

Search Result 47, Processing Time 0.028 seconds

Comparison of fucosterol content in algae using high-performance liquid chromatography

  • Lee, Jeong Min;Jeon, Jae Hyuk;Yim, Mi-Jin;Choi, Grace;Lee, Myeong Seok;Park, Yun Gyeong;Lee, Dae-Sung
    • Fisheries and Aquatic Sciences
    • /
    • v.23 no.3
    • /
    • pp.9.1-9.6
    • /
    • 2020
  • Background: Fucosterol is a compound commonly found in algae that has various biological activities. The purpose of this study was to develop a high-performance liquid chromatography (HPLC) validation method for fucosterol and to compare the fucosterol contents of 11 algal species from Ulleungdo, Korea. Method: In this study, we successfully isolated and identified fucosterol from a 70% EtOH extract of Sargassum miyabei, and subsequently conducted specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision analyses for development of an HPLC validation method. Fucosterol contents were compared using the established HPLC validation conditions. Results: We successfully isolated fucosterol from a 70% EtOH extract of S. miyabei and identified it based on spectroscopic analysis. On the basis of HPLC validation using the fucosterol isolated from S. miyabei, we confirmed specificity (8.5 min), linearity (R2 = 0.9998), LOD (3.20 ㎍ mL-1), LOQ (9.77 ㎍ mL-1), accuracy (intra-day and inter-day variation, 90-110%), and precision (RSD, 1.07%). Fucosterol contents in the 11 assessed algal species ranged from 0.22 to 81.67 mg g-1, with the highest content being recorded in a 70% EtOH extract of Desmarestia tabacoides (81.67 mg g-1), followed by that of Agarum clathratum (78.70 mg g-1). Conclusions: The results indicate that 70% EtOH extracts of D. tabacoides and A. clathratum containing fucosterol with various effects can be potential alternative sources of fucosterol.

Simultaneous Determination of Doxifluridine and 5-FU in Liver and Intestine Tissue Using LC/MS/MS (LC/MS/MS를 이용한 원숭이 및 비글견의 간 및 장관 조직에서의 Doxifluridine과 대사체 5-FU 동시분석법 개발)

  • Woo, Young-Ah;Kim, Ghee-Hwan;Jeong, Eun-Ju;Kim, Choong-Yong
    • YAKHAK HOEJI
    • /
    • v.52 no.2
    • /
    • pp.93-100
    • /
    • 2008
  • A liquid chromatographic method with tandom spectrometric detection (LC/MS/MS) for the simultaneous determination of doxifluridine and its active metabolite, 5-fluorouracil (5-FU) was developed over the concentration range of $5{\sim}2000$ ng/ml, respectively. Doxifluridine, 5-FU and internal standard, 5-chlorouracil (5-CU), were extracted from liver and intestine tissue via protein precipitation. Acetonitrile was used as the extraction solvent and the supernatant was evaporated and reconstructed in mobile phase. Optimum chromatographic separation was achieved on a Agilent Zorbax $C_{18}$ ($100\;mm{\times}2.1\;mm$, $3.5\;{\mu}m$) column with mobile phase run in isocratic with methanol : water (20 : 80, v/v). The flow rate was 0.2 ml/min with total cycle time of 5 min. The lower limit of quantification was validated at 5.0 ng/ml of liver and intestine tissue, for both doxifluridine and 5-FU, respectively. The intra-day and inter-day precision and accuracy of quality control (QC) samples were <11% coefficient of variation and <7% relative error from theoretical concentration for both analytes. In addition, the special designed stability study was performed, because the metabolism of doxifluridine occurs spontaneously even in ice bath for monkey liver. The stability of doxifluridine in liver and intestine of monkey and beagle dog was compared. It was found that bioanalytical validation could not be performed for the monkey liver; however, beagle dog's liver has relatively low speed of metabolism compared to monkey liver and instead of monkey liver, beagle dog's liver could be used for the validation. Bioanalytical validation could be performed in monkey intestine. Eventually, this developed method for liver and intestine will be useful in support of the toxicokinetic and pharmacokinetic studies of doxifluridine and 5-FU.

Trace Analysis of Racemic Isomers of Flurbiprofen in Human Urine using Column Switching-HPLC (컬럼스위칭 액체크로마토그래피를 이용한 뇨중 플루비프로펜의 광학이성질체의 미량분석)

  • Choi, Hyun-Cheol;Kang, Sin-Jung;Youn, Mi-Ok;Lee, Su-Jung;Kim, Ho-Jung;Park, Chang-Hun;Cha, Ki-Won
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.529-533
    • /
    • 2002
  • The separation and determination method of racemic isomers of flurbiprofen in urine samples have been investigated using column switching- HPLC, which include the sample treatment and concentration column. The optical rotation of two isomers separated were measured to identify d-form and l-form. The calibration curves are liear in the ranges of $0.11-5.4{\mu}g/mL$ for both d-form and l-form. The detection limits were $0.031{\mu}g/mL$ for l-isomes and $0.027{\mu}g/mL$ for d-isomer. The coefficients of variation of intra-day and inter-day precision of this method were about 1.8%. The present method was apllied to determine the concentration of racemic isomers in urine sample from human eating the drug.

Revisiting the Parvilucifera infectans / P. sinerae (Alveolata, Perkinsozoa) species complex, two parasitoids of dinoflagellates

  • Jeon, Boo Seong;Nam, Seung Won;Kim, Sunju;Park, Myung Gil
    • ALGAE
    • /
    • v.33 no.1
    • /
    • pp.1-19
    • /
    • 2018
  • Members of the family Parviluciferaceae (Alveolata, Perkinsozoa) are the well-known dinoflagellate parasitoids along with Amoebophrya ceratii species complex and parasitic chytrid Dinomyces arenysensis and contain six species across three genera (i.e., Parvilucifera infectans, P. sinerae, P. rostrata, and P. corolla, Dinovorax pyriformis, and Snorkelia prorocentri) so far. Among Parvilucifera species, the two species, P. infectans and P. sinerae, are very similar or almost identical each other morphologically and genetically, thereby make it difficult to distinguish between the two. The only main difference between the two species known so far is the number of sporangium wall (i.e., 2 layers in P. infectans vs. 3 layers in P. sinerae). During sampling in Masan bay, Korea during the spring season of 2015, the dinoflagellate Akashiwo sanguinea cells infected by the parasite Parvilucifera were observed and this host-parasite system was established in culture. Using this culture, its morphological and ultrastructural features with special emphasis on the variation in the number of sporangium wall over developmental times, were investigated. In addition, the sequences of rDNA regions and ${\beta}-tubulin$ genes were determined. The result clearly demonstrated that the trophocyte at 36 h was covered with 4 layers, and then outer layer of the sporocyte gradually degraded over time, resulting in wall structure consisting of two layers, with even processes being detached from 7-day-old sporangium with smooth surface, indicating that the difference in the number of layers seems not to be an appropriate ultrastructural character for distinguishing P. infectans and P. sinerae. While pairwise comparison of the large subunit rDNA sequences showed 100% identity among P. infectans / P. sinerae species complex, genetic differences were found in the small subunit (SSU) rDNA sequences but the differences were relatively small (11-13 nucleotides) compared with those (190-272 nucleotides) found among the rest of Parvilucifera species (P. rostrata and P. corolla). Those small differences in SSU rDNA sequences of P. infectans / P. sinerae species complex may reflect the variations within inter- strains of the same species from different geographical areas. Taken together, all morphological, ultrastructural, and molecular data from the present study suggest that they are the same species.

Comparison of Extraction Methods for Determination of Vitamin K1 in Vegetables (채소류의 비타민 K1 분석을 위한 추출방법의 비교)

  • Kim, Hyeongi;Choi, Youngmin;Cho, Young-Sook;Sung, Jeehye;Ham, Hyeonmi;Lee, Junsoo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.11
    • /
    • pp.1791-1795
    • /
    • 2014
  • The objective of this study was to compare two extraction methods for determination of vitamin K1 (phylloquinone) in vegetables. In addition, analytical method validation parameters such as accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), and linearity were calculated to ensure the method's validity. Vitamin K1 was quantified by reversed-phase HPLC using post-column derivatization and fluorescence detection ($Ex{\lambda}=243nm$, $Ex{\lambda}=430nm$). Higher analytical values were observed using solvent extraction compared to those from the enzyme extraction method. The results from the method validation showed high linearity in the calibration curve with a coefficient of correlation ($R^2$) of 0.9994. The LOD and LOQ were 0.1335 and 0.2784 ng/injection volume ($50{\mu}L$), respectively. The inter-day precision and inter-day precision were 2.0% and 2.1%, respectively. Overall recovery was close to 100% (n=5). The phylloquinone contents ranged from 9.42 to $1,212.57{\mu}g/100g$. Our study provides reliable data on the phylloquinone contents in commonly consumed vegetables in Korea.

Confirmation of Schizandrin as a Marker Compound in Jangsu Omija Powder (HPLC를 이용한 기능성 원료 지표성분으로서 장수 오미자 분말 중 Schizandrin의 분석법 개발)

  • Kim, Yunjeong;Ha, Na;Han, Song-Hee;Jeon, Ji-Young;Hwang, Minho;Im, Yong-Jin;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.2
    • /
    • pp.244-248
    • /
    • 2013
  • We studied the development of schizandrin as a marker compound in Jangsu Omija. Schizandrin was validated for its LOD (limit of detection), LOQ (limit of quantitation), precision, accuracy, and recovery by HPLC relative to Omija powder. It showed a high linearity in the calibration curve with a coefficient of correlation ($R^2$) of 0.9990. The LOD and LOQ were 0.2 ${\mu}g/mL$ and 0.5 ${\mu}g/mL$, respectively. The intra- and inter-day precision of schizandrin calibration standards was 0.06~0.66% and 0.13~1.19%, respectively, and the intra- and inter-day accuracy of schizandrin was 98.35~103.30% and 98.35~103.00%, respectively. Overall, schizandrin was validated through our analytical methods as a marker compound in Jangsu Omija.

Simultaneous Determination of Aflatoxins and Ochratoxin A in Pork by LC-MS/MS (LC-MS/MS를 이용한 돼지고기 중 총아플라톡신 및 오크라톡신 A 동시분석법 확립)

  • Paek, Ockjin;Park, Songyi;Park, Ki Hun;Kim, Sheen-Hee;Suh, Saejung;Yoon, Hae Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.3
    • /
    • pp.194-200
    • /
    • 2016
  • Aflatoxins and ochratoxin A (AFTs and OTA) are secondary fungal metabolites produced by several moulds, mainly by Aspergillus flavus by Aspergillus ochraceus and Penicillium verrucosum, and these toxins can be transferred to animals and humans through the ingestion of contaminated feed and food. This study was to develop the analytical method for determination the levels of AFTs ($B_1$, $B_2$, $G_1$ and $G_2$) and OTA in pork. The AFTs and OTA were analyzed simultaneously by electrospray ionization in positive ion mode and mass reaction monitoring (MRM) after solid phase extract (SPE) columns clean-up. Performance characteristics, such as accuracy, precision, linear range, limit of detection (LOD) and quantification (LOQ), were also determined. Matrix-matched standard calibration was used for quantification, obtaining the recoveries in the range of 67.3~108.2% with the relative standard deviations of < 20%. Limits of detection and quantification were also estimated, obtaining the limits of quantification ranged in $0.7{\sim}1.3{\mu}g/kg$. The results of the inter-day study, which was performed with pork samples for 3 days, showed an accuracy of 92.0~109.9%. The precisions (expressed as relative standard deviation values) for the inter day variation were 2.6~17.8%. The method developed in this study was able to carry out the analysis with the satisfactory intensity and accuracy.

Uncertainty evaluation of the analysis of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in hair by GC-NCI-MS/MS (GC-NCI-MS/MS를 이용한 모발 중 대마 대사체 분석의 측정불확도 평가)

  • Kim, Jin-Young;Lee, Jae-Il;Cheong, Jae-Chul;Suh, Yong-Jun;In, Moon-Kyo
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THC-COOH), the metabolite of ${\Delta}^9$-tetrahydrocannabinol, in hair samples by using the bead-assisted liquid-liquid extraction and gas chromatography-tandem mass spectrometric (GC-NCI-MS/MS) detection. Traceability of measurement was established through the use of reference materials, calibrated volumetric tubes, volume measuring devices, and measuring instruments. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day variation was performed by using statistical analysis of several indicative factors. Measurement uncertainty associated with the analyte in real forensic hair samples were estimated using QC data. The major factor of contribution to combined standard uncertainty was inter-day repeatability, while those associated with preparation of analytical standard and also sample of weight were insignificant considering the degree of contribution. Relative uncertainty of relative extended standard uncertainty divided into the measured concentration of the analyte was 17% in a hair sample. The uncertainty of result evaluation will be invaluable to improve quality of the analysis.

Analytical Method for Sodium Polyacrylate in Processed Food Products by Using Size-exclusion Chromatography (Size-exclusion Chromatography를 활용한 가공식품 중 폴리아크릴산나트륨 분석법 확립)

  • Jeong, Eun-Jeong;Choi, Yoo-Jeong;Lee, Gunyoung;Yun, Sang Soon;Lim, Ho Soo;Kim, MeeKyung;Kim, Yong-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.6
    • /
    • pp.466-473
    • /
    • 2018
  • An analytical method of sodium polyacrylate in processed food products was developed and monitored by using size-exclusion chromatography. GF-7M HQ column and UV/VIS detector were selected based on peak shape and linearity. Flow rate, column oven temperature, and mobile phase were selected as 0.6 mL/min, $45^{\circ}C$, and 50 mM sodium phosphate buffer of pH 9.0, respectively. Samples for analysis of sodium polyacrylate were extracted with 50 mM sodium phosphate buffer of pH 7.0 for 3 hr at $20^{\circ}C$ and 150 rpm. Analytical method validation revealed proper selectivity and calibration curve was selected in the range of 50-500 mg/L, and correlation coefficient of calibration curve was more than 0.9985. Limit of detection of sodium polyacrylate was 10.95 mg/kg and limit of quantification was 33.19 mg/kg. Accuracy and coefficient of variation for sodium polyacrylate analysis was 99.6-127.6%, 3.0-8.3% for intra-day and 94.3-121.9%, 1.3-2.6% for inter-day, respectively. Sodium polyacrylate was detected in 40 samples among monitored 125 processed food products. Detected contents were less than 0.2%, limited by the Food Additives Code. Results suggest the established size-exclusion chromatography method could be used to analyze sodium polyacrylate in processed food products.

Determination of Hydrochlorothiazide in Human Plasma by HPLC and Applicability to Oral Bioavailability in Korean Healthy Male Volunteers (HPLC를 이용한 혈중 히드로클로로티아지드의 분석 및 이를 이용한 한국인 성인남성에 대한 생체이용률 평가)

  • Park, Ah-Yeon;Kim, Jin-Hee;Kim, Sung-Yong;Chi, Sang-Cheol;Bok, Hae-Sook;Kim, Ho-Jung;Youm, Jeong-Rok;Han, Sang-Beom
    • YAKHAK HOEJI
    • /
    • v.50 no.5
    • /
    • pp.301-307
    • /
    • 2006
  • A simple and sensitive high-performance liquid chromatographic method for quantitation of hydrochlorothiazide in human plasma was developed and bioavailability parameters of hydrochlorothiazide were assessed in Korean healthy male volunteers. Caffeine was used as an internal standard. Hydrochlorothiazide and internal standard in plasma sample were extracted using tert-butylmethylether (TBME). A centrifuged upper layer was then evaporated and reconstituted with mobile phase of acetonitrile-25 mM phosphate buffer (20/80, pH 2.5). The reconstituted samples were injected into a Luna C18 column $(250{\times}4.6\;mm,\;5{\mu}m)$ at a flow-rate of 1.0 ml/min. The wavelength was set at 230 nm and no endogenous substances were found to interfere, A linear relationship for hydrochlorothiazide was found in the range of $10{\sim}300\;ng/ml$. The lower limit of quantitation (LLOQ) was 10 ng/ml with acceptable precision and accuracy. Assayed in plasma, the intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. Main pharmacokinetic parameters of 50mg of hydrochlorothiazide were revealed as follows: $AUC_t\;1761{\pm}509.0\;ng{\cdot} hr\;ml,\;C_{max}\;296.5{\pm}95.5\;ng/ml,\;T_{max}\;1.94{\pm}0.85hr,\;K_{el}\;0.12{\pm}0.04\;hr^{-1}\;and T_{12}\;6.81{\pm}2.92\;hr.\;C_{max}\;and\;T_{max}$ were in accordance with the values $(270{\sim}350\;ng/ml\;and\;1.9{\sim}2.7\;hr)$ of Caucasian.