• Title/Summary/Keyword: Intensity uniformity

Search Result 133, Processing Time 0.023 seconds

Evaluation of Light Intensity and Uniformity of LEDs for Protected Crop Production

  • Kim, MunJung;Choo, YounKug;Kim, YongJoo;Chung, SunOk
    • Agribusiness and Information Management
    • /
    • v.6 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • This study was conducted to evaluate light intensity and uniformity of two SMD (surface-mount device) type LEDs for protected crop production. A low-power (0.1 W) and a high-power (1 W) LEDs were selected and the intensity and uniformity was evaluated at different vertical (height) and horizontal (distance) intervals. When the horizontal interval of the LED bar was fixed, the light intensity increased and the uniformity decreased as the height decreased. At the 30~40 cm heights, 20~30% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. As the horizontal distance of the LED bars increased, while the uniformity increased as well, the light intensity decreased. At the distances of 6~10 cm, 17~23% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. When the LED bars were added to the sides, the light intensity and uniformity were generally improved. Results showed that the light intensity and uniformity depended on the height and interval of the LED bulbs; therefore, optimum arrangement for the crops interested should be determined through experiments.

A Study of Aspheric Mirror Optical Design to Improve Luminous Intensity Uniformity of LED Security Lights (LED 보안등의 광균일도 향상을 위한 비구면 Mirror형 광학 설계에 관한 연구)

  • Jung, In-Ho;Yoon, Cheol-Yong;Ye, In-Soo;Hyun, Dong-Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.1
    • /
    • pp.114-119
    • /
    • 2011
  • There is a limit to technology of improving luminous intensity uniformity and glare, known as a weakness of existing LED lamp. Because of Using many LED, LED lamp not only waste energy but have bad effect on efficiency. Our goal is to develop security lights solution which is contented with suitable area in KS(Korean Industrial Standards) and to remove glare by combining asphere in optical system with different concept. To improve luminous intensity uniformity, a reflect mirror system was used after an aspheric optical system design for this study. We made a mirror and measured it after analysing luminance changes depend on aspheric shapes with simulation program to see if aspheric shapes effect luminance distribution. We made progress to find problems and improve them by comparing measured data and analysed data. This result of the study will contribute to industry of LED lighting through developing solution of emotional illumination of LED security lights by knowing the importance of reflectivity with this study and improving luminous intensity uniformity with solving the problem.

Study on the Aerodynamic Characteristics of Hanyang Low Speed Wind Tunnel (한양대학교 중형 아음속 풍동의 공력특성에 관한 연구)

  • Go, Gwang Cheol;Jeong, Hyeon Seong;Kim, Dong Hwa;Jo, Jin Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.92-98
    • /
    • 2003
  • The optimum design of Hanyang low speed wind tunnel has been performed to augment flow uniformity and to reduce turbulence intensity of wind tunnel test section have to be known for reliability of wind tunnel test. The non-uniformity and turbulence intensity of Hanyang low speed wind tunnel were measured with Pilot tube and X-type hot-wire probe at various wind speeds. As the results, the non-uniformity decreases as the wind speed increases. The non-uniformity is relatively high in the proximity of the diffuser. The turbulence intensity is a little higher than design requirement in the middle of the test section.

Uniformity calibration of large area full color light emitted diodes screens

  • Gibour, Veronique;Leroux, Thierry;Boher, Pierre;Bouwens, Luc
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.475-478
    • /
    • 2004
  • In this paper, we describe a powerful solution for efficient LED wall calibration through the use of a quality 2D-luminance meter : the MURATest and a dedicated applicative software. The intended calibration allows adjusting individually the intensity of each LED so as to obtain a good uniformity on the module. Furthermore the intensity of each module can be adjusted one to the others so as to obtain a good uniformity on a complete display and maintain it even after module exchange for display maintenance needs.

  • PDF

LED simulation analysis using optical system of reflex (반사 광학계를 이용한 LED Simulation 분석)

  • Yoon, Chul-Yong;Noh, Myeong-Jae;Kim, Byoung-Man;Jeong, Byoung-Jo;Roh, Yong-Gi
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.159-162
    • /
    • 2010
  • There are some limitations to advance technology glaring and luminous Intensity uniformity known as the weak point of existing LED lamp. To improve the two weak points, there have been no special alternative methods so far. Instead, one method which is being used such as the twisting secondary lens or arbitrary structure to remove glaring and improve luminous Intensity uniformity. Based on this academic background, it is necessary to be examined on Technology of Optical System to solve the two weak points by using not complicated but simple methods. This paper will examine the angle of reflection in order to improve luminous intensity uniformity. Also, this research will present the method using lighting analysis program to verify a hypothesis. Through the analysis program, we could understand the simulation analysis method and got some problems about the analysis result. After analysis of causes through reinterpretation of problems, we have reached a conclusion that was changed according to reflectivity and the shape of aspherics by main cause which effected luminous Intensity uniformity and glaring.

  • PDF

Assessment of portable traveling pluviator to prepare reconstituted sand specimens

  • Dave, Trudeep N.;Dasaka, S.M.
    • Geomechanics and Engineering
    • /
    • v.4 no.2
    • /
    • pp.79-90
    • /
    • 2012
  • Air pluviation method is widely adopted for preparation of large, uniform and repeatable sand beds of desired densities for laboratory studies to simulate in-situ conditions and obtain test results which are highly reliable. This paper presents details of a portable traveling pluviator recently developed for model sand bed preparation. The pluviator essentially consisted of a hopper, orifice plates for varying deposition intensity, combination of flexible and rigid tubes for smooth travel of material, and a set of diffuser sieves to obtain uniformity of pluviated sand bed. It was observed that sand beds of lower relative density can be achieved by controlling height of fall, whereas, denser sand beds could be obtained by controlling deposition intensity. Uniformity of pluviated sand beds was evaluated using cone penetration test and at lower relative densities minor variation in density was observed with depth. With increase in relative density of sand bed higher repeatability of uniform pluviation was achieved.

Effect of Mixer Structure on Turbulence and Mixing with Urea-water Solution in Marine SCR System (선박용 SCR 시스템에서 혼합기 구조에 따른 난류유동과 우레아 수용액의 혼합특성)

  • Kim, Tae-Kyoung;Sung, Yon-Mo;Han, Seung-Han;Ha, Sang-Jun;Choi, Gyung-Min;Kim, Duck-Jool
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.814-822
    • /
    • 2012
  • To improve the flow and mixing characteristics of marine SCR system, two different mixer including up-down and swirl type mixer were considered. The purpose of this study is to analyse turbulence intensity and uniformity index in detail and to improve the performance of SCR with respect to the mixer structure. The results showed that, the concentration uniformity index is improved by about 5% with the utilization of both mixers in the front of catalyst part. Although the RMS value and relative turbulence intensity increased after the up-down type mixer, it could observed that the value of two parameters decreased with the flow proceeding forward to the downstream. For the case of swirl type mixer, the decrease of RMS value and relative turbulence intensity were relatively smaller than that of up-down type mixer, and uniform distribution of relative turbulence intensity was observed. As a results, it could be concluded that the mixing effects and the distance of the two kinds of mixer were different.

Comparative Analysis of Cartesian Trajectory and MultiVane Trajectory Using ACR Phantom in MRI : Using Image Intensity Uniformity Test and Low-contrast Object Detectability Test (ACR 팬텀을 이용한 Cartesian Trajectory와 MultiVane Trajectory의 비교분석 : 영상강도 균질성과 저대조도 검체 검출률 test를 사용하여)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.39-46
    • /
    • 2019
  • This study conducted a comparative analysis of differences between cartesian trajectory in a linear rectangular coordinate system and MultiVane trajectory in a nonlinear rectangular coordinate system axial T1 and axial T2 images using an American College of Radiology(ACR) phantom. The phantom was placed at the center of the head coil and the top-to-bottom and left-to-right levels were adjusted by using a level. The experiment was performed according to the Phantom Test Guidance provided by the ACR, and sagittal localizer images were obtained. As shown in Figure 2, slices # 1 and # 11 were scanned after placing them at the center of a $45^{\circ}$ wedge shape, and a total of 11 slices were obtained. According to the evaluation results, the image intensity uniformity(IIU) was 93.34% for the cartesian trajectory, and 93.19% for the MultiVane trajectory, both of which fall under the normal range in the axial T1 image. The IIU for the cartesian trajectory was 0.15% higher than that for the MultiVane trajectory. In axial T2, the IIU was 96.44% for the cartesian trajectory, and 95.97% for the MultiVane trajectory, which fall under the normal range. The IIU for the cartesian trajectory was by 0.47% higher than that for the MultiVane trajectory. As a result, the cartesian technique was superior to the MultiVane technique in terms of the high-contrast spatial resolution, image intensity uniformity, and low-contrast object detectability.

Monitoring and Controlling Uniformity of Plasma Emission Intensity for IGZO Sputtering Process (IGZO박막 증착 공정에서 플라즈마 방출광 모니터링 및 플라즈마 균일도 제어)

  • Choi, Jinwoo;Hwang, Sang Hyuk;Kim, Woo Jae;Shin, Gi Won;Kwon, Heui Tae;Jo, Tae Hoon;Woo, Won Gyun;Cha, Sung Duk;An, Byung Chul;Park, Wan Woo;Do, Jae Chul;Kwon, Gi-Chung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.4
    • /
    • pp.27-32
    • /
    • 2016
  • In recent years, various researches have been conducted to improve process yields in accordance with miniaturization of semiconductor. APC(Advanced Process Control) is considered one of the methods to increase in process yields. APC is a process control technology that maintains optimal process conditions and improves the reliability of results by controlling and formulating the relationship among the various process parameters and results. We built up an optical diagnostic system with a three-channel spectrometer. The system detects signals those represent the changes of specific emission peaks intensity versus each reference and converts it into MFC control signals to get back the changes to the reference state. Controlling the MFC continues until the specific peak intensity changes into the normal state. Through this device, we tested a APC automatically responding to process changes during the plasma process. We could control gas flow while sputtering process on going and improve uniformity of plasma intensity with this system. Finally, we have got results those enhance the plasma intensity non-uniformity to 7.7% from 15.5%. Also, found unexpected oxygen flow what is estimated to be come out from IGZO target.

The Conditions of a Holographic Homogenizer to Optimize the Intensity Uniformity (주기적인 홀로그램을 이용한 레이저 광 세기 균일화기에서 균일도를 최적화하기 위한 홀로그램의 조건)

  • Go, Chun-Soo;Oh, Yong-Ho;Lim, Sung-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.7
    • /
    • pp.578-583
    • /
    • 2011
  • We report on the design of a holographic homogenizer composed of a periodic hologram and a condensing lens. If the hologram is periodic, the homogenizer is free from the alignment error of the incident laser beam. Holographic homogenizer also has an advantage of the flexibility in the size of the target beam. We calculated theoretically the Fraunhofer diffracted wave function when a rectangular laser beam is incident on a periodic hologram. The diffracted wave is the sum of sinc functions at regular distance. The width of each sinc function depends on the size of the incident laser beam and the distance between the sinc functions depends on the period of the hologram. We calculated numerically the diffracted light intensity for various ratios of the size of the incident laser beam to the period of the hologram. The results show that it is possible to make the diffracted beam uniform at a certain value of the ratio. The uniformity is high at the central part of the target area and low near the edge. The more sinc functions are included in the target area, the larger portion of the area becomes uniform and the higher is the uniformity at the central part. Therefore, we can make efficient homogenizer if we design a hologram so that the maximum number of the diffracted beams may be included in the target area.