• Title/Summary/Keyword: Intensity operation

Search Result 445, Processing Time 0.028 seconds

Operating performance of squid jigging vessel using the LED and metal halide fishing lamp combination (LED와 메탈핼라이드 집어등을 겸용한 오징어채낚기 어선의 조업 성능)

  • An, Heui-Chun;Bae, Jae-Hyun;Bae, Bong-Seong;Park, Jong-Myung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.4
    • /
    • pp.395-403
    • /
    • 2013
  • Fishing efficiency of the squid jigging vessel using the LED and metal halide fishing lamp combination was analyzed to reduce the cost for fishing operation utilizing the fishing light system for high degree of efficiency in the squid jigging fishery (one of the representative coastal and offshore fisheries in Korea). This study aims to improve the nature of existing LED lamps and to develop fan-shaped LED lights having 180W of power and ${\pm}45^{\circ}$ angle of light intensity distribution. The marine experiment for making a comparison of their fishing efficiency was tested by a 9.77 tons fishing vessel from Oct. through Dec. 2012. As a result, experimental fishing vessel showed slightly higher fishing efficiency than the average of metal halide lamp-equipped vessel and 20% energy savings. This means that the combination of LED and metal halide lamps would provide an efficient way to lower energy consumption while maintaining fishing efficiency.

Cavity and Interface effect of PI-Film on Charge Accumulation and PD Activity under Bipolar Pulse Voltage

  • Akram, Shakeel;Wu, Guangning;Gao, GuoQiang;Liu, Yang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2089-2098
    • /
    • 2015
  • With the continuous development in insulation of electrical equipment design, the reliability of the system has been enhanced. However, in the manufacturing process and during operation under continues stresses introduce local defects, such as voids between interfaces that can responsible to occurrence of partial discharge (PD), electric field distortion and accumulation of charges. These defects may lead to localize corrosion and material degradation of insulation system, and a serious threat to the equipment. A model of three layers of PI film with air gap is presented to understand the influence of interface and voids on exploitation conditions such as strong electrical field, PD activity and charge movement. The analytical analysis, and experimental results are good agreement and show that the lose contact between interfaces accumulate more residual charges and in consequences increase the electric field intensity and accelerates internal discharges. These residual charges are trapped charges, injected by the electrodes has often same polarity, so the electric field in cavities increases significantly and thus partial discharge inception voltage (PDIV) decreases. Contrary, number of PD discharge quantity increases due to interface. Interfacial polarization effect has opposite impact on electric field and PDIV as compare to void.

LED Headlight, Safety and Application in Oral Surgery (구강 수술에 사용가능한 LED 헤드라이트의 안전성 및 실용성)

  • Yoo, Young-Sam;Heo, Geon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.2
    • /
    • pp.187-192
    • /
    • 2010
  • Background and Objectives : LED(Light emitting diode) is recently introduced as a energy-saving light source in many area including agriculture and environment. In medical field it is known as bright and safe light source in surgical lighting including headlight. This study is aimed to test effectiveness and cost-saving of mountain-climbing headlight in comparison with xenon headlight. Materials and Methods : Internet market-available mountain-climbing headlight was compared with medical xenon headlight regarding heat generation after 30 minutes' usage, intensity of illumination and possible burn to the perioral skin. To get temperature data, 5 cases of tonsillectomy were done with the aid of LED headlight, while another 5 tonsillectomies were done using xenon headlight. Results : The temperatures of all light sources were below 45 degrees Celcius until finish of the surgery without burn or complications. No differences in operation time with both headlights. The maximal intensities of illumination were 24000 Lux for xenon, 20000 Lux for LED. Conclusion : Mountain-climbing headlight could be safe and helpful light source with low cost in simple oral surgery.

Utilization of Laser Range Measurements for Guiding Unmanned Agricultural Machinery

  • Jung, I. G.;Park, W. P.;Kim, S. C.;Sung, J. H.;Chung, S. O.
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.69-74
    • /
    • 2001
  • Detection of operation lines in farm works, object recognition and obstacle avoidance are essential pre-requisite technologies for unmanned agricultural machinery. A CCD camera, which has been largely used for these functions, is expensive and has difficulty in real-time signal processing. In this study, a laser range sensor was selected as the guiding vision for unmanned agricultural machinery such as a tractor. To achieve this capability, algorithms for distance measurement, signal filtering, object recognition, and obstacle avoidance were developed. Computer simulations were carried out to evaluate performance of the algorithms. Experiments were also conducted with various materials and shapes, Laser beam lost its intensity for poor reflective materials, resulting in less range value than actual, so a compensation technique was considered to be necessary. Object detection system was fabricated on an agricultural tractor and the performance was evaluated. As test result for obstacle detection and avoidance in field, to detect and avoid obstacle for path finding with guiding system for unmanned agricultural machinery was enable.

  • PDF

Analysis of Preferable Café Interior Design Using Human Sensibility Ergonomics For Different Age Groups

  • Seo, Hyung Soo
    • Architectural research
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2006
  • Maximizing profit is the most significant object of commercial places. Especially for some places where its atmosphere is main concern of customers like $Caf{\acute{e}}s$, interior design is crucial. Thus it needs to evaluate human emotion and preference. Human Sensibility Ergonomics which is recently signified in various fields is an attempt to quantitatively analyze factors of human sensibility and apply it to design operation. This study attempted to infuse human sensibility ergonomics into $Caf{\acute{e}}$ interior design and analyzed preferable $Caf{\acute{e}}$ interior design factors. Because most $Caf{\acute{e}}s$ have their own target customers, so we assumed four different target customer groups divided by their age and gender groups in each age group. As a result, the difference of each group could be examined. Middle-aged group and males have main interest in the intensity of luminance, i.e. the brightness, whereas youths and females attach importance to both quality of light and color. In addition, there is a tendency for middle-aged group and males to see $Caf{\acute{e}}$ as a public place while young people and females recognize $Caf{\acute{e}}$ as a place for entertainment. Taking the result of this study into consideration can lead to successful $Caf{\acute{e}}$ interior design for specific target customers.

A Study of Nitrification Kinetics in the Biofilter Process for Aquaculture Water Treatment: A Review (양식 수처리를 위한 생물막 공정에서 질산화 영향인자에 대한 고찰)

  • Park, Noh Back;Park, Mi Seon;Lee, Jin Hwan;Myeong, Jeong In
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.46 no.6
    • /
    • pp.675-681
    • /
    • 2013
  • There have been many studies on biofilter process regarding satisfactory water quality and the operational conditions of Recirculating Aquaculture Systems (RAS). For effective nitrification processes, it is necessary to dynamically identify and apply nitrifying microorganisms. Physical, chemical and biological processes concerning biofilms can be applied and influential factors including substrate, dissolved oxygen concentrations, organic matter, temperature, pH, alkalinity, salinity and mixing velocity intensity need to be considered. Also, designing and managing the process based on the dynamic interpretation of these factors are prerequisites for engineering applications of the biofilter process. This paper draws on current literature on the kinetics of nitrification of biofilms in the biofilter process. Influential factors for nitrification are crucial during the biofilter process and are expected to be critical in informing the design and operation of recirculating aquaculture systems.

Numerical Study on Earthquake Performance of Gravity Dam Considering Earthquake Frequencies (지진진동수에 따른 콘크리트 중력댐의 내진성능에 대한 해석적 사례연구)

  • Chai, Young-Suk;Min, In-Ki
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.64-74
    • /
    • 2016
  • Recently, the seismic stability evaluation of concrete gravity dams is raised due to the failure of dams occurred by the Izmit, Turkey and JiJi, Taiwan earthquake in 1999. Dams failure may incur loss of life and properties around the dam as well as damage to dam structure itself. Recently, there has been growing much concerns about "earthquake - resistance" or "seismic safety" of existing concrete gravity dams designed before current seismic design provisions were implemented. This research develops three evaluation levels for seismic stability of concrete gravity dams on the basis of the evaluation method of seismic stability of concrete gravity dams in U.S.A., Japan, Canada, and etc. Level 1 is a preliminary evaluation which is for purpose of screening. Level 2 is a pseudo-static evaluation on the basis of the seismic intensity method. And level 3 is a detail evaluation by the dynamic analysis. Evaluation results on existing concrete gravity dams on operation showed good seismic performance under designed artificial earthquake(KHC earthquake).

Computational Studies on the Combustion and Thermal Performance of the Coal Fired Utility Boiler : Temperature and Thermal Energy Distribution (석탄화력 보일러 연소열성능 해석 : 온도와 열에너지 분포를 중심으로)

  • Seo, Sang-Il;Park, Ho-Young;Lee, Sung-No
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.157-166
    • /
    • 2009
  • The pulverized coal combustion behavior in the coal fired utility boiler has been investigated with the CFD and process analysis techniques. The used commercial software were CFX and PROATES, and these were coupled each other to get more reliable boundary condition set-up, resulting in more reliable solution. For two cases which were the actual operation condition of A power plant, the calculated values from the coupled CFD and process analysis for thermal energy system were compared with the plant data, and the good agreements were obtained for Case 1 and 2. The calculated temperature distributions on the surface of heat exchangers were compared with the plant data for the steam temperatures across heat exchangers, and these explained the actual operating situation very well. The temperature deviation across the final superheater tube, which was believed to be the main cause of the frequent tube failure, were also explained very well with the calculated distributions of gas temperature and radiation on the plane of the final superheater.

Performance Prediction of a Hot Water Supply and Panel Heating System with Solar Energy (태양열 온수 및 난방 일체형 복합시스템의 성능예측)

  • Han, Yuri;Park, Youn Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.11-17
    • /
    • 2012
  • In this study, a simulation program was developed with heat transfer model in the thermal storage tank for a solar collector and burner combined heating and hot water supply system. Analysis was conducted with variation of operating condition and schedule to analyze performance of a hot water supply and panel heating system with a solar collector and burner combined thermal storage tank. The simulation program is divided two sections. One part is calculation of temperature variation of water which flows through the panel in the floor for heating of the residential house during 24 hours, and the other part is heat transfer calculation for the reaction time to get desired water temperature in the thermal storage tank. As results, light oil consumption and system performance during operation period were analyzed with variation of climate condition and with or without solar collector. Most of the case, oil could be saved about from 24 to 41% with installing the solar collector. The performance of the system is more dependent on radiation time of the solar collector rather than the intensity of the solar radiation which was adopted for the climate analysis.

Electro-Optic Characteristics according to Distance between Pixel Electrodes in Fringe In-plane field Switching mode (화소 전극 간 거리가 Fringe In-plane field Switching mode의 전기 광학 특성에 미치는 영향)

  • Kim, Min-Su;Park, Ji-Woong;Jung, Jun-Ho;Ha, Kyung-Su;Lim, Young-Jin;Lee, Myong-Hoon;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.337-338
    • /
    • 2008
  • We have studied electro-optic characteristics of a high performance liquid crystal display using Fringe In-plane field Switching (FIS) mode. The strong electric fields cause more liquid crystals to reorient almost in plane above and between the pixel electrodes. As a result, the operation voltage is lower and transmittance is higher than those of Fringe Field Switching (FFS) and In-Plane Switching (IPS) modes. Apparently, the transmittance depends on voltage applied at the configurations of FIS mode which are proposed. Therefore, we have studied certain length of between electrodes for maximum transmittance and light intensity.

  • PDF