• Title/Summary/Keyword: Intensity of bond

Search Result 130, Processing Time 0.03 seconds

Local Structure Refinement of the $BaFe_{1-x}Sn_xO_{3-y}$ System with Fe K-Edge X-Ray Absorption (XANES/EXAFS) Spectroscopy

  • 김민규;곽기섭;로권선;여철현
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.7
    • /
    • pp.743-749
    • /
    • 1997
  • Local structure refinement of the BaFe1-xSnxO3-y system (x=0.00-0.50) has been carried out with Fe K-edge x-ray absorpion spectroscopic studies. It is found out that the Fe ions are placed in two different symmetric sites such as tetrahedral and octahedral sites in the compounds by comparison with Fe K-edge x-ray absorption near edge structure (XANES) spectrum of the γ-Fe2O3 compound as a reference. Small absorption peaks of dipole-forbiden transitions appear at a pre-edge region of 7111 eV due to the existence of Fe ions in the tetrahedral and octahedral sites. The peak intensity decreases with the substitution amount of Sn ion. Three different absorption peaks of 1s→4p dipole-allowed transition appear on the energy region between 7123 and 7131 eV. The peaks correspond to 1s→4p main transition of Fe ions in tetrahedral and octahedral sites and 1s→4p transition followed by the shakedown process of ligand to metal charge transfer. The bond distances between Fe ions in the tetrahedral site and nearest neighboring oxygen atom (Fe-4O), and those in octahedral site (Fe-6O) are determined with the extended x-ray absorption fine structure (EXAFS) analysis. Two different interatomic distances increase with the substitution amount of Sn ion and also the bond lengths of Fe-4O are shorter than those of Fe-6O in all compounds.

A STUDY ON THE MATERIAL PROPERTIES OF VARIOUS COMPOSITE RESINS FOR CORE BUILD-UP (수종 코어용 복합레진 수복재의 물성에 관한 연구)

  • Shin, Soo-Il;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.191-199
    • /
    • 2004
  • The purposes of this study were to estimate the material properties of the recently developed domestic composite resins for core filling material (Chemical, Dual A, Dual B;Vericom, Korea) and to compare them with other marketed foreign products (CorePaste, Den-Mat, USA;Ti-Core, Essential Dental Systems, USA;Support. SCI-Pharm. USA). Six assessments were made:working time. setting time. depth of polymerization. flexural strength. bonding strength. and marginal leakage. All items were compared to ISO standards. All domestic products satisfied the minimum requirements from ISO standards (working time:above 90 seconds. setting time:within 5 minutes). and showed significantly higher flexural strength than Core Paste. Dual A and B could. especially. reduce the setting time to 60 seconds when cured with $600mW/cm^2$ light intensity. All experimental materials showed 6 mm depth of polymerization. Bond strengths of Ti-Core and Dual B materials were significantly higher than the other materials. Furthermore. three domestic products and Ti-Core could reduce the microleakage effectively.

Development of Wafer Bond Integrity Inspection System Based on Laser Transmittance

  • Jang, Dong-Young;Ahn, Hyo-Sok;Mehdi, Sajadieh.S.M.;Lim, Young-Hwan;Hong, Seok-Kee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.2
    • /
    • pp.29-33
    • /
    • 2010
  • Among several critical topics in semiconductor fabrication technology, particles in addition to bonded surface contaminations are issues of great concerns. This study reports the development of a system which inspects wafer bond integrity by analyzing laser beam transmittance deviations and the variations of the intensity caused by the defect thickness. Since the speckling phenomenon exists inherently as long as the laser is used as an optical source and it degrades the inspection accuracy, speckle contrast is another obstacle to be conquered in this system. Consequently speckle contrast reduction methods were reviewed and among the all remedies have been established in the past 30 years the most adaptable solution for inline inspection system is applied. Simulation and subsequently design of experiments has been utilized to discover the best solution to improve irradiance distribution and detection accuracy. Comparison between simulation and experimental results has been done and it confirms an outstanding detection accuracy achievement. Bonded wafer inspection system has been developed and it is ready to be implemented in FAB in the near future.

MICROLEAKAGE OF CL V COMPOSITE RESTORATIONS USING VARIOUS LIGHT CURING METHODS (광중합 복합레진 수복시 여러 광조사 방법에 따른 미세변연누출에 관한 연구)

  • Yang, Chol-Young;Yoo, Hyeon-Mee;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.299-308
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the microleakage of 5 curing methods in class V composite restorations which are composed of two-step light curing, pulse-delay cure, low curing-light intensity, moderate curing-light intensity and high curing-light intensity. In this study, class V cavities were prepared on buccal and lingual surfaces of 50 extracted human upper or lower molars on cementum margin. Single Bond adhesive and Z-100 shade A2 were applied for each group following the manufacture's instruction. The experimental teeth were randomly divided into 5 groups of 10 samples (20 surfaces) each. Group 1: two-step light curing; Group 2: pulse-delay cure; Group 3: low curing-light intensity; Group 4: moderate curing-light intensity; Group 5: high curing-light intensity. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 60 teeth were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen was then observed with a stereomicroscope at ${\times}20$. The composite resin/tooth interfaces were examined under Scanning Electron Microscopy. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA and Dunn's Method. The results of this study were as follows. 1. In all groups, the leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. No group in this study showed significant differences in leakage values at both the enamel and the dentin margins(P<0.05). 3. In all groups, the gaps seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 4. The gaps in this study showed significant differences and two-step light-curing and low curing-light intensity produced significant less gap than high curing-light intensity(P<0.05).

  • PDF

Spectroscopic Comparison of Photo-oxidation of Outside and Inside of Hair by UVB Irradiation (자외선B 조사에 의한 모발 외부와 내부의 광산화에 관한 분광학적 비교)

  • Ha, Byung-Jo
    • Applied Chemistry for Engineering
    • /
    • v.31 no.2
    • /
    • pp.220-225
    • /
    • 2020
  • Hair is made of proteins containing various amino acids. Ultraviolet (UV) radiation is believed to be responsible for the most damaging effects of sunlight, and also plays an important role in hair aging. The purpose of this study was to investigate the changes in morphological and chemical structures after ultraviolet B (UVB) irradiation of human hair. The UVB-irradiated hair showed characteristic morphological and structural changes, compared to those of the normal hair. The result from a scanning electron microscope (SEM) equipped with an energy dispersive X-ray diffractometer (EDX) showed that the scale of UV-irradiated hair appeared to be rough and the amount of oxygen element was higher than that of the normal hair. Fluorescence and three dimensional (3D) topographical images were obtained by a confocal laser scanning microscope (CLSM). In 3D images, the green emission intensity of normal hair was much higher than that of fluorescing UVB-irradiated hair. The intensity of green emission reflects the intrinsic fluorescence of hair protein. Also, a fluorescent imaging method using fluorescamine reagent was used to identify the free amino groups resulting from a peptide bond breakage in UVB-irradiated hair. Strong blue fluorescence of UVB-irradiated hair, which indicates a very high level of amino groups, was observed by CLSM. Therefore, the fluorescamine as an extrinsic fluorescence could provide a useful tool to identify the peptide bond breakage in UVB-irradiated hair. Infrared image mapping was also employed to assess the cross-sections of normal and UVB-irradiated specimens to examine the oxidation of disulfide bonds. The degree of peak areas with strong absorbance for the disulfide mono-oxide was spread from the outside to the inside of hair. The spectroscopic techniques used alone, or in combination, launch new possibilities in the field of hair cosmetics.

Study on Lowering of the Polarization in SiOC Thin FIlms by Post Annealing (SiOC 박막에서 열처리에 의한 분극의 감쇄현상에 관한 연구)

  • Oh, Teresa
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.8
    • /
    • pp.1747-1752
    • /
    • 2012
  • The SiOC film of carbon centered system was prepared using bistrimethylsilylmethane (BTMSM) and oxygen mixed precursor by the chemical vapor deposition. The dielectric constant is measured by MIS(metal/insulator/Si) structure, but it could decrease the reliability because the uniformity is not assured. To research the dielectric constant of SiOC film, the range of low polarization was researched in SiOC film using the optical analysis and hardness, and then calculated the dielectric constant of SiOC film with amorphous structure of high degree. After annealing, the dielectric constant of SiOC film was decreased owing to the lowering of polarization, and FTIR spectra of the main bond was shifted to higher wave number. The main bond of 950~1200 cm-1 was composed of the Si-C and Si-O bonds. The intensity increases in Si-O bond infers the bonding strength became stronger than that of deposited film. Annealed SiOC film showed 2.06 in dielectric constant.

The Adsorption of Amines on Silicates. Distinction Protonic and Aprotonic Acids Sites (Silicate 上에서의 아민의 吸着. Protonic 酸 자리와 Aprotonic 酸 자리의 區別)

  • Kim Jong-Taik;Sohn Jong-Rack
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.441-447
    • /
    • 1976
  • The infrared spectra obtained in the region of $4000∼1200 $cm^{-1}$ has been measured for pyridine, tertiary butylamine, and ethylenediamine adsorbed on various cation-exchanged silicates at various degassing temperature. It was possible to distinguish between protonic and aprotonic acid sites of all cation-exchanged silicates which exhibited both Bronsted and Lewis acidity. The sodium form appeared to be the least reactive towards adsorbates. The relative ratio of the band intensities of tertiary butylamine was directly related to the polarizing power of exchanged cations. Ethylenediamine was less easily desorbed from silicate surface than tertiary butylamine due to the additional amino group to react with surface active site, and probably to form ether hydrogen bond with surface oxgen by liberating migrating proton besides the coordination bond with Lewis acid site and the formation of$NH3^+$ species with Bronsted acid site.

  • PDF

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

Influence of Wax Molecular Weights on Wax Migration and Evaporation of Rubber Vulcanizates at Room Temperature (상온 노화 후 고무가황물에서 왁스의 이동과 증발에 미치는 왁스의 분자량 분포)

  • Im, Song-Hee;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.44 no.4
    • /
    • pp.397-400
    • /
    • 2009
  • Ozone caused the crack on the surface of a rubber article by oxidation of double bond at room temperature. Wax migrates to the surface of a rubber article and makes a physical barrier to prevent process of ozonation. We investigated change of molecular weight distribution of waxes in unfilled NR, SBR, and BR vulcanizates before and after aging at room temperature for 6 months. Migration and evaporation behaviors of wax in a rubber article at ambient conditions help understand a role of wax as an antidegradant and appearance contamination of a rubber article. The relative intensity distribution of n-alkanes of the NR specimen after the aging was shifted to higher molecular weight compared with the relative intensity distribution before the aging, while those of the SBR specimen before and after the aging did not show a big difference.

Thin Film Characterization on Refractive Index of PECVD SiO2 Thin Films

  • Woo Hyuck Kong;In Cheon Yoon;Seung Jae Lee;Yun Jeong Choi;Sang Jeen Hong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.2
    • /
    • pp.35-39
    • /
    • 2023
  • Silicon oxide thin films have been deposited by plasma-enhanced chemical vapor deposition in SiH4 and N2O plasma along the variation of the gas flow ratio. Optical emission spectroscopy was employed to monitor the plasma and ellipsometry was employed to obtain refractive index of the deposited thin film. The atomic ratio of Si, O, and N in the film was obtained using XPS depth profiling. Fourier Transform Infrared Spectroscopy was used to analyze structures of the films. RI decreased with the increase in N2O/SiH4 gas flow ratio. We noticed the increase in the Si-O-Si bond angles as the N2O/SiH4 gas flow ratio increased, according to the analysis of the Si-O-Si stretching peak between 950 and 1,150 cm-1 in the wavenumber. We observed a correlation between the optical emission intensity ratio of (ISi+ISiH)/IO. The OES intensity ratio is also related with the measured refractive index and chemical composition ratio of the deposited thin film. Therefore, we report the added value of OES data analysis from the plasma related to the thin film characteristics in the PECVD process.

  • PDF