• 제목/요약/키워드: Intensity modulated radiation therapy(IMRT)

검색결과 202건 처리시간 0.022초

전립선암 치료를 위한 세기조절 양성자 로버스트 치료계획 (Robust Planning of Intensity-modulated Proton Therapy for Prostate Cancer)

  • 박수연;김종식;박주영;박원;주상규
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.25-31
    • /
    • 2013
  • 목 적: 양성자선의 유효비정 변화와 환자 자세의 재현성을 고려한 로버스트(robust-IMPT) 세기조절양성치료와 플레인 세기조절양성자치료(plain-IMPT) 계획과 광자선 세기조절방사선치료(photon-IMRT, step & shoot) 계획의 선량분포 특성을 비교, 분석하고자 한다. 대상 및 방법: 다섯 명의 전립선암 환자를 대상으로 표적에 70 Gy를 조사하도록 photon-IMRT (7문, step & shoot)와 plain-IMPT (2문, 4문, 7문) 및 robust-IMPT (유효 비정 오차 ${\pm}5%$ & 환자 자세 오차 0.5 cm 적용) 치료계획을 수립했다. 세 가지 치료계획으로 얻은 선량 분포 비교를 위해 PTV에 대한 선량조형지수(Conformity Index, CI), 선량균등지수(Homogeneity Index, HI) 및 최대선량, 최소선량, 평균선량과 OAR에 대한 선량-체적을 평가했다. 결 과: 모든 환자에 대해 photon-IMRT, plain-IMPT, robust-IMPT에서 PTV의 평균 최대선량은 각각 76.75 Gy (109.6%), 71.92 Gy (102.7%), 72.09 Gy (103%)였으며, 평균 최소선량은 68.21 Gy (97.4%), 68.89 Gy (98.42%), 68.13 Gy (98.13%)였으며, 전체 평균선량은 각각 71.02 Gy (101.4%), 71.32 Gy (100.4%), 70.75 Gy (101%)였다. PTV에 대한 CI 및 HI 값은 plain-IMPT가 photon-IMRT와 robust-IMPT에 비하여 1.02, 1.00으로 가장 낮았다. 또한, 정상장기에 있어 plain-IMPT가 photon-IMRT에 비하여 대부분 낮은 선량 분포를 보였으며, robust-IMPT 적용 시 정상 장기에 대한 선량 분포가 다소 변동의 폭은 있었지만 photon-IMRT에 비하여 대체로 낮은 선량 분포를 보였다. 결 론: 전립선암의 IMPT 치료 시 정확한 유효비정의 오차와 환자 자세 재현성오차를 고려한 robust-IMPT를 적용한다면 plain-IMPT의 선량학적 불확도를 줄이고 photon-IMRT에 비해 효과적인 치료를 제공할 수 있을 것이다.

  • PDF

Dosimetric Verification for Primary Focal Hypermetabolism of Nasopharyngeal Carcinoma Patients Treated with Dynamic Intensity-modulated Radiation Therapy

  • Xin, Yong;Wang, Jia-Yang;Li, Liang;Tang, Tian-You;Liu, Gui-Hong;Wang, Jian-She;Xu, Yu-Mei;Chen, Yong;Zhang, Long-Zhen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권3호
    • /
    • pp.985-989
    • /
    • 2012
  • Objective: To make sure the feasibility with $^{18F}FDG$ PET/CT to guided dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma patients, by dosimetric verification before treatment. Methods: Chose 11 patients in III~IVA nasopharyngeal carcinoma treated with functional image-guided IMRT and absolute and relative dosimetric verification by Varian 23EX LA, ionization chamber, 2DICA of I'mRT Matrixx and IBA detachable phantom. Drawing outline and making treatment plan were by different imaging techniques (CT and $^{18F}FDG$ PET/CT). The dose distributions of the various regional were realized by SMART. Results: The absolute mean errors of interest area were $2.39%{\pm}0.66$ using 0.6cc ice chamber. Results using DTA method, the average relative dose measurements within our protocol (3%, 3 mm) were 87.64% at 300 MU/min in all filed. Conclusions: Dosimetric verification before IMRT is obligatory and necessary. Ionization chamber and 2DICA of I'mRT Matrixx was the effective dosimetric verification tool for primary focal hyper metabolism in functional image-guided dynamic IMRT for nasopharyngeal carcinoma. Our preliminary evidence indicates that functional image-guided dynamic IMRT is feasible.

세기조절 방사선 치료에서 CORVUS TPS를 이용한 $\textrm{IMFAST}^{TM}$ Segmentation Algorithm의 연구 (Study of $\textrm{IMFAST}^{TM}$ Segmentation Algorithm with CORVUS TPS for Intensity Modulated Radiation Therapy)

  • Lee, Se-Byeong;Jino Bak;Cho, Kwang-Hwan;Chu, Sung-Sil;Lee, Chang-Geol;Lee, Suk;Hongryll Pyo;Suh, Chang-Ok
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.181-186
    • /
    • 2002
  • 세기조절 방사선 치료는 각각의 치료계획 시스템의 도스 최적화 알고리즘과 선형 가속기의 조합에 따라 다양하게 최적의 성능을 발휘 할 수 있다. 연세 암센터는 효과적인 방사선치료를 위하여 2002년 2월에 세기조절 방사선 치료 시스템을 도입하여 운영 중에 있으며 도입된 시스템은 CORVUS (Nomos, 미국) 치료계획 시스템과 LANTIS, PRIMEVIEW, PRIMART (Siemens, 미국)의 선형가속기 시스템으로 구성되어 있다. 최적화된 치료를 위해서는 CORVUS 치료계획기와 PRIMART 선형가속기의 적절한 조합 조건을 찾아 적용하는 것이 중요한 일이다. 이 Step & Shoot 방식의 세기조절 방사선 치료기는 Finite Size Pencil Beams (FSPB) 도스모델과 simulated annealing method의 도스 최적화 알고리즘 및 IMFAST의 segmentation 알고리즘을 사용하고 있다. 본 연구는 segmentation 알고리듬에 관한 것으로 두개의 기본 beamlet 크기(1.0$\times$1.0 $\textrm{cm}^2$ 와 0.5$\times$1.0$\textrm{cm}^2$)와 4가지의 빔 세기 단계(5%, 10%, 20%, 33%)의 option을 4명의 상이한 환자 case에 대하여 적용하고 비교해 보았다. 상대적으로 작은 target 부피를 갖는 경우 TPS상의 segmentation의 설정에 민감하게 target 도스분포가 변하였으며 작은 beamlet일수록 intensity step을 작게 할수록 최적의 도스분포를 보여주었다.

  • PDF

AAPM TG-119 보고서를 통한 세기조절방사선치료(IMRT)와 부피적세기조절회전치료(VMAT)의 치료 전 환자별 정도관리 (The Patient Specific QA of IMRT and VMAT Through the AAPM Task Group Report 119)

  • 강동진;정재용;김종하;박승;이근섭;손승창;신영주;김연래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권3호
    • /
    • pp.255-263
    • /
    • 2012
  • 본 연구에서는 AAPM TG-119 보고서를 통해 본원에 도입된 세기조절방사선치료(IMRT)와 부피적세기조절회전치료(VMAT)의 치료 전 환자별 정도관리(patient specific QA)를 시행하고자 하였다. 본원의 치료계획장치를 이용해 각각의 치료계획을 수립하여 절대선량은 표적 및 위험장기에 전리함을 이용해 측정하였고 상대선량분포는 $DELTA^{4PT}bi$-planar diode array를 사용하여 측정하였다. 치료계획의 평가는 선량체적히스토그램을 이용하였고 선량검증은 측정값과 계산값을 비교하여 시행하였다. 치료계획평가에서 전립선의 경우에는 두 치료법 모두 표적과 위험장기의 목표선량에 도달하였으며 두경부와 Multi target의 경우, 세기조절방사선치료는 표적에서는 목표선량에 도달하지 못하였지만 부피적세기조절 회전치료는 표적과 위험장기 모두 목표선량에 도달하였다. C-shape(easy)은 두 치료법이 표적과 위험장기 모두 목표선량에 도달하였고, C-shape(hard)의 경우엔, 두 치료법이 표적에서는 목표선량에 도달하였으나 위험장기에서는 목표선량에 도달하지 못하였다. 절대선량평가에서는 세기조절방사선치료의 경우 평균오차율의 평균값이 표적에서 $1.24{\pm}2.06%$, 위험장기에서 $1.4{\pm}2.9%$였고 신뢰구간은 표적에서 3.65%, 위험장기에서 4.39%였다. 부피적세기조절회전치료는 평균오차율의 평균값이 표적에서 $2.06{\pm}0.64%$, 위험장기에서 $2.21{\pm}0.74%$ 였고 신뢰구간은 표적에서 4.09%, 위험장기에서 3.04%로 두 치료법 모두 제안된 허용기준인 표적에서 4.5%, 위험장기에서 4.7% 이내였다. 상대선량평가에서는 세기조절방사선치료의 경우 허용기준을 통과하는 감마인덱스의 평균값은 $98.3{\pm}1.5%$였고 신뢰구간은 3.78%였다. 부피적세기조절회전치료의 경우엔 평균값이 $98.2{\pm}1.1%$였고 신뢰구간은 3.95%로 두 치료법 모두 제안된 허용기준인 7.0% 이내였다. 따라서 이번 연구에서 실시한 시험을 통해 본원의 세기조절방사선치료와 부피적세기조절회전치료가 보고서에서 제안된 허용기준에 모두 부합하고 사용에 적합함을 확인할 수 있었다.

세기조절방사선치료에서 선량율 변화에 따른 선량분포 특성 (Property of Dose Distribution in Accordance with Dose Rate Variation in Intensity Modulated Radiation Therapy)

  • 강민규;김성준;신현수;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제21권2호
    • /
    • pp.218-222
    • /
    • 2010
  • 세기조절방사선치료(intensity modulated radiation therapy, IMRT)는 치료면적을 소조사면으로 나누어 여러 방향에서 방사선이 조사되기 때문에 기존의 치료방법에 비해 많은 MU와 더 긴 치료시간이 요구된다. 통증 및 장애 등으로 인해 장시간 같은 자세를 유지하기 어려운 환자의 경우, 효과적인 치료를 위해서는 선량율을 증가시켜 치료시간을 줄이는 것이 한 방법이다. 본 연구에서는 선량율 변화에 따른 선량 및 선량분포를 측정하고 그 변화를 알아보았다. IMRT 치료계획은 ECLIPSE 시스템(Varian, SomaVision 6.5, USA)을 이용하여, $0^{\circ}$, $72^{\circ}$, $144^{\circ}$, $216^{\circ}$, $288^{\circ}$ 방향의 5문 조사로 계획하였다. 선량율 변화에 따른 선량 및 선량분포 확인을 위해 선량율은 100, 300, 500 MU/min으로 설정하였으며, 선량과 선량분포는 이온함(PTW, TN31014)과 필름(EDR2, Kodak)을 이용하여 각각 측정하였다. 이때 필름 선량계는 아크릴 팬톰에 삽입 후 빔의 조사방향과 나란하게 설치되었고 방사선조사를 위한 선형가속기는 21EX-S (Varian, USA)를 이용하였다. 측정된 필름 선량계는 VXR-16 (Vidar System Corporation)을 이용하여 분석함으로써 선량분포를 확인하였다. 선량율이 증가할수록 CTV를 포함하는 100% 선량분포의 면적이 거의 선형적으로 감소함을 보였다.

두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향 (The Effect of Volume Reduction on Computed Treatment Planning during Head and Neck IMRT and VMAT)

  • 엄기천;김가중;백금문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.239-246
    • /
    • 2023
  • In this study, we assessed the effect of reduction of tumor volume in the head and neck cancer by using RANDO phantom in Static Intensity-Modulated Radiation Therapy (S-IMRT) and Volumetric-Modulated Arc Therapy (VMAT) planning. RANDO phantom's body and protruding volumes were delineated by using Contour menu of Eclipse™ (Varian Medical System, Inc., Version 15.6, USA) treatment planning system. Inner margins of 2 mm to 10 mm from protruding volumes of the reference were applied to generate the parameters of reduced volume. In addition, target volume and Organ at Risk (OAR) volumes were delineated. S-IMRT plan and VMAT plan were designed in reference. These plans were assigned in the reduced volumes and dose was calculated in reduced volumes using preset Monitor unit (MU). Dose Volume Histogram (DVH) was generated to evaluate treatment planning. Conformity Index (CI) and R2 in reference S-IMRT were 0.983 and 0.015, respectively. There was no significant relationship between CI and the reduced volume. Homogeneity Index (HI) and R2 were 0.092 and 0.960, respectively. The HI increased when volume reduced. In reference VMAT, CI and R2 were 0.992 and 0.259, respectively. There was no relationship between the volume reduction and CI. On the other hand, HI and R2 were 0.078 and 0.895, respectively. The value of HI increased when the volume reduced. There was significant difference (p<0.05) between parameters (Dmean and Dmax) of normal organs of S-IMRT and VMAT except brain stem. Volume reduction affected the CI, HI and OAR dose. In the future, additional studies are necessary to incorporate the reduction of the volume in the clinical setting.

Effectiveness and feasibility of concurrent chemoradiotherapy using simultaneous integrated boost-intensity modulated radiotherapy with and without induction chemotherapy for locally advanced pancreatic cancer

  • Oh, Eun Sang;Kim, Tae Hyun;Woo, Sang Myung;Lee, Woo Jin;Lee, Ju Hee;Youn, Sang Hee;Han, Sung Sik;Park, Sang Jae;Kim, Dae Yong
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.200-209
    • /
    • 2018
  • Purpose: To evaluate the effectiveness and feasibility of chemoradiotherapy (CRT) using simultaneous integrated boost-intensity modulated radiotherapy (SIB-IMRT) in locally advanced pancreatic cancer (LAPC) patients. Materials and Methods: Between January 2011 and May 2015, 47 LAPC patients received CRT using SIB-IMRT. Prior to SIB-IMRT, 37 patients (78.7%) received induction chemotherapy (IC-CRT group) and remaining 10 patients (21.3%) did not received induction chemotherapy (CRT group). During SIB-IMRT, all patients received concomitant chemotherapy, with gemcitabine (n = 37) and capecitabine (n = 10). Results: At the time of analysis, 45 patients had died and 2 patients remained alive and the median follow-up time was 14.2 months (range, 3.3 to 51.4 months). For all patients, the median times of local progression-free survival (LPFS), progression-free survival (PFS), and overall survival (OS) were 18.1, 10.3, and 14.2 months, respectively. The median time of LPFS between IC-CRT and CRT groups was similar (18.1 months vs. 18.3 months, p = 0.711). IC-CRT group had a higher trend in PFS (10.9 months vs. 4.1 months, p = 0.054) and had significantly higher OS (15.4 months vs. 9.5 months, p = 0.007) than CRT group. In multivariate analysis, the use of induction chemotherapy and tumor response were significant factors associated with OS (p < 0.05, each). During SIB-IMRT, toxicity of grade ≥3 was observed in 7 patients (14.9%) in all patients. Conclusions: CRT using SIB-IMRT is feasible and promising in LAPC patients.

HalcyonTM 선형가속기 6MV-FFF 에너지의 표재 선량에 대한 고찰: Phantom Study (A Study on Superficial Dose of 6MV-FFF in HalcyonTM LINAC: Phantom Study)

  • 최성훈;엄기천;유순미;박제완;송흥권;윤인하
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.31-39
    • /
    • 2020
  • 목 적: 본 연구는 HalcyonTM과 TrueBeamTM에서 사용하는 6MV-FFF(Flattening Filter Free) 에너지를 이용하여 전산화치료계획시스템(Treatment Planning System, TPS)에서 계산된 선량과 광자극형광선량계(Optically Stimulated Luminescence Dosimeter, OSLD)로 측정된 표재 선량(Superficial dose)을 비교하고자 한다. 재료 및 방법: 팬텀연구를 위해 인체모형 팬텀(Human Phantom)의 CT 영상을 이용하여 치료계획시스템에서 성문암(Glottic cancer)과 유사한 치료계획용적(Planning Target Volume, PTV)과 두경부위의 등 중심점(Iso-center) 위치에 측정을 위한 Point(M), Point(R), Point(L)의 구조물을 설정하고 체표윤곽(Body contour)에 5mm Bolus를 적용하였다. 그 후 전산화치료계획은 HalcyonTM과 TrueBeamTM의 6MV-FFF 에너지를 이용하여 정적(Static) 세기변조방사선치료(Intensity Modulated Radiation Therapy, IMRT)와 용적변조회전치료(Volumetric Modulated Arc Therapy, VMAT)계획을 각각 수립하였다. 전산화치료계획과 동일하게 재현하기 위해 OSLD를 등 중심점에 위치시키고 5mm Bolus를 적용하여 선량 전달 후 오차율을 비교하였다. 결 과: 인체모형 팬텀을 사용한 실험 결과 HalcyonTM의 전산화치료계획시스템에서의 점 선량과 OSLD를 이용한 선량 측정의 오차율의 절댓값의 평균은 VMAT, IMRT 각각 1.7±1.2%, 4.0±2.8%로 확인되었으며, TrueBeamTM의 오차율의 절댓값의 평균은 VMAT, IMRT 각각 2.4±0.4%, 8.6±1.8%로 확인되었다. 결 론: 실험결과 HalcyonTM을 기준으로 TrueBeamTM에서 VMAT과 IMRT 각각 2.4배, 3.6배 더 큰 오차가 발생하는 것을 확인할 수 있었다. 따라서 본 연구의 결과를 토대로 표재 선량에 대한 정확한 선량평가가 이루어져야 하는 경우, TrueBeamTM보다 HalcyonTM에서 정확한 선량 평가가 이루어질 수 있을 것으로 사료된다.

A Comparison between Portal Dosimetry and Mobius3D Results for Patient-Specific Quality Assurance in Radiotherapy

  • Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon;Oh, Se An
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the clinical quality assurance results of portal dosimetry using an electronic portal imaging device, a method that is extensively used for patient-specific quality assurance, and the newly released Mobius3D for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods: This retrospective study includes data from 122 patients who underwent IMRT and VMAT on the Novalis Tx and VitalBeam linear accelerators between April and June 2020. We used a paired t-test to compare portal dosimetry using an electronic portal imaging device and the average gamma passing rates of MobiusFX using log files regenerated after patient treatment. Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm) were 99.43%±1.02% and 99.32%±1.87% in VitalBeam and 97.53%±3.34% and 96.45%±13.94% in Novalis Tx, respectively. Comparison of the gamma passing rate results of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm as per the manufacturer's manual) does not show any statistically significant difference. Conclusions: Log file-based patient-specific quality assurance, including independent dose calculation, can be appropriately used in clinical practice as a second-check dosimetry, and it is considered comparable with primary quality assurance such as portal dosimetry.

세기조절방사선치료의 정도관리를 위한 모니터유닛 공간분포 재구성의 효용성 평가 (MU Fluence Reconstruction based-on Delivered Leaf Position: for IMRT Quality Assurance)

  • 박소연;박양균;박종민;최창헌;예성준
    • Journal of Radiation Protection and Research
    • /
    • 제36권1호
    • /
    • pp.28-34
    • /
    • 2011
  • 세기조절방사선치료(Intensity Modulated Radiotherapy, IMRT)의 정도관리를 위해서 독립적인 방법으로 선량검증을 하는 것은 중요하다. 독립적 선량검증을 위해 팬톰과 이온전리함을 이용한 측정 방법이 보편적으로 이루어지지만 많은 시간과 노력이 요구된다. 본 연구에서는 세기조절방사선치료 시 시간에 따른 다엽콜리메이터의 움직임을 기록한 dynalog 파일을 이용하여 치료계획에서 도출된 총 실제 플루언스와 실제 치료 시의 모니터유닛(monitor unit, MU) 공간분포를 비교함으로써 간편한 세기조절방사선치료 정도관리 기술을 개발하였다. DICOM RT plan 파일로부터 총 실제 플루언스를 추출하고 MATLAB 코드를 이용하여 실제 치료 시 MU 공간분포를 dynalog 파일로부터 계산하였다. 개발된 방법의 효용성을 검증하기 위해 단계별조사기법과 동적조사기법으로 치료 받은 각 5명의 환자 데이터를 후향적으로 분석하였다. 분석 방법은 상용프로그램(Verisoft 3.1, PTW, German)에서 제공하는 감마인덱스를 사용하였다. 분석 결과 실제 치료 시의 MU 공간분포와 치료계획 상의 MU 공간분포 일치도가 평균 $97.8{\pm}1.33$%로 높은 일치도를 나타냈다. MU 공간분포 재구성의 정확도는 동적조사기법보다 단계별조사기법이 평균 1.4% 높았다. 본 연구에서 개발된 기술을 통해 세기조절방사선치료의 선량검증을 효과적으로 수행할 수 있다. 또한 분할치료 시 선량보정에 적용함으로써 맞춤형치료(adaptive radiotherapy)를 위한 기초자료로 사용될 수 있을 것이다.