• Title/Summary/Keyword: Intensity limit

Search Result 362, Processing Time 0.03 seconds

Sausage Waves in a Plasma Cylinder with a Surface Current

  • Lim, Daye;Nakariakov, Valery M.;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.81.1-81.1
    • /
    • 2019
  • Linear sausage oscillations of a cylinder embedded in a plasma with an azimuthal magnetic field, created by a current on the surface of the cylinder, are studied. Such a plasma configuration could be applied to modelling demonstrate that the lowest radial harmonic of the sausage mode is in the trapped regime for all values of the parallel wave number. In the long-wavelength limit, phase and group speeds of this mode are equal to the Alfven speed in the external medium. It makes the oscillation period to be determined by the ratio of the parallel wavelength, e.g., double the length of an oscillating loop, to the external Alfven speed, allowing for its seismological estimations. The application of the results obtained to the interpretation of long-period (longer than 20-30 s) oscillations of emission intensity detected in solar coronal structure, gives reasonable estimations of the external Alfven speed. Cutoff values of the parallel wavenumber for higher radial harmonics are determined analytically. Implications of this finding to the observational signatures of fast magnetoacoustic wave trains guided by the plasma non-uniformity are discussed.

  • PDF

Sensitivity Analysis for Allowable Operating Period Based on the Flaw Tolerance Evaluation of ASME BPVC Section XI Appendix L (ASME BPVC Section XI Appendix L의 결함허용평가에 따른 허용운전주기 민감도 분석)

  • Changsik Oh;Dooho Cho;Myung Jo Jhung
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.126-136
    • /
    • 2021
  • During operation of nuclear power plants, the fatigue assessment should be conducted repeatedly, considering changes of operating environments. For the case that cumulative usage factors (CUFs) may exceed the acceptance limit, flaw tolerance evaluation can be an alternative method to meet the regulatory requirements. In this respect, this paper analyzes the effects of the input variables for flaw tolerance evaluation based on ASME BPVC Section XI Appendix L. The reference analysis is performed for the example problem in NUREG/CR-6934. Then effects of the crack orientation, stress intensity factor solutions, thermal stress profiles, fatigue stress decomposition and fatigue crack growth curves are considered for the sensitivity analysis. The results show that the stress analysis considering the actual environment plays a crucial role in flaw tolerance evaluation.

Comparison of ACFAS method and DNPH-LC method for quantitative analysis of formaldehyde in Drinking water (자동연속흐름-흡광광도법과 DNPH-LC법에 의한 먹는물 중 포름알데히드 정량분석 비교)

  • Yi, Geon-Ho;Yun, In-Chul;Kim, Yeong-Kwan;Kim, Chong-Chaul;Choi, Geum-Jong;Lee, Teak-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.827-836
    • /
    • 2013
  • Due to the stringent drinking water quality, formaldehyde will be included in Korean drinking water standard from year 2014. However, its standard analytical method has not yet been established. This study compares two analytical methods, DNPH-LC and ACFAS with respect to their analysis principles, Method Detection Limit (MDL), Limit Of Quantitation(LOQ), precision, accuracy, reproducibility, convenience, number of samples analyzed per hour and analysis cost. These methods measure absorption intensity at 360 nm by using HPLC after DNPH-derivatization (DNPH-LC) and at 410 nm by using Automated Continuous Flow Absorption Spectrophotometer (ACFAS), respectively. Reproducibility was tested by repeating the analysis 7 times using a standard solution for each method. For DNPH-LC method, MDL was $0.5{\mu}g/L$, LOQ was $1.58{\mu}g/L$ with standard deviation of $0.16{\mu}g/L$. For ACFAS method, they were $0.27{\mu}g/L$, $0.85{\mu}g/L$L with standard deviation of $0.09{\mu}g/L$, respectively. Both methods satisfied the requirement set by the Korean drinking water quality standard. Complexity of sample pretreatment procedure for DNPH-LC method may cause large error and, consequently, the analytical result will depend on the level of skill of analyst. In contrast, ACFAS method which used only one reagent equipped with an automated injection device showed little analytical error. It costs about $5.00 and $1.00 for one sample to analyze by the DNPH-LC method and the ACFAS method, respectively. Compared to the DNPH-LC method, ACFAS method provided more reliable analytical results. In terms of convenience, easiness and analytical cost, ACFAS method was demonstrated to be superior to the DNPH-LC method. The results of this study suggested that the ACFAS method could be adapted as a proper method for determining formaldehyde content in drinking water.

Investigation of Fatigue Strength and Prediction of Remaining Life in the Butt Welds Containing Penetration Defects (블완전용입 맞대기 용접재의 용입깊이에 따른 피로강도특성 및 잔류수명의 산출)

  • Han, Seung Ho;Han, Jeong Woo;Shin, Byung Chun
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.423-435
    • /
    • 1998
  • In this paper fatigue strength reduction of butt weld with penetration defect, which can be seen frequently in the steel bridge, was assessed quantitatively. S-N curves were derived and investigated through the constant amplitude fatigue test of fully or partially penetrated welded specimen made of SWS490 steel. The fracture mechanical method was applied in order to calculate the remaining fatigue life of the partially penetrated butt welds. The fatigue limit of the fully penetrated butt welds was higher than that of category A in AASHTO's fatigue design curves, and the slope of S-N curves with 5.57 was stiffer than that of other result for welded part generally accepted as 3. The fatigue strength of the partially Penetrated butt weld was strongly influenced by the size of lack of penetration, D. It decreased drastically with increasing D from 3.9 to 14.7mm. Fracture behaviour of the partially penetrated butt weld is able to be explained obviously from the beach mark test that a semi-elliptical surface crack with small a/c ratio initiates at a internal weld root and propagates through the weld metal. To estimate the fatigue life of the partially penetrated butt weld with fracture mechanics, stress intensity factors K of 3-dimensional semi-elliptical crack were calculated by appling finite elements method and fracture mechanics parameters such as C and m were derived through the fatigue test of CT-specimen. As a result, the fatigue lives obtained by using the fracture mechanical method agreed well with the experimental results. The results were applied to Sung-Su bridge collapsed due to penetration defects in butt weld of vertical member.

  • PDF

Determination of Eu(III) by Fluorescence Spectrometry (형광분광법에 의한 Eu(Ⅲ)의 정량)

  • Lee, Sang Hak;Han, Jong Hwan;Choi, Sang Seob
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.3
    • /
    • pp.285-291
    • /
    • 1998
  • Methods to determine EU(Ⅲ) ion in aqueous solution by fluorescence spectrometry based upon the ligand sensitized fluorescence of Eu(Ⅲ)-terephthalic acid (TPA) complex ion have been studied. The effects of excitation wavelength, pH, concentration of TPA and emission wavelength on the fluorescence intensity were investigated. The fluorescence intensity of the Eu(Ⅲ) complex ion was further increased with addition of trioctylphosphine oxide (TOPO). In this case Triton X-100 was used to dissolve TOPO in aqueous solution. The calibration curve for Eu(Ⅲ) was linear over the range from $1.0{\times}10^{-6}M\;to\;4.0{\times}10^{-4}M$ and the detection limit was $1.0{\times}10^{-6}M$ under the experimental conditions of 256 nm, 5.6, $3.5{\times}10^{-4}$M$ and 615 nm for excitation wavelength, pH, concentration of TPA and emission wavelength, respectively. When TOPO was added to the Eu(Ⅲ)-TPA system, the concentration range of linear response and the detection limit were $1.0 {\times}10^{-9}M\;to\;1.0{\times}10^{-4}M,\;1.0{\times}10^{-7}M,$ respectively under the experimental conditions of 284 nm, 4.4 and $1.0{\times} 10^{-4}M$ for excitation wavelength, pH and concentration of TOPO, respectively. Effects of interferences from various cations for the determination of Eu(Ⅲ) ion were also investigated.

  • PDF

Determination of Fe(II) ion and Fe(III) ion by Chemiluminescence Method (화학발광법을 이용한 Fe(Ⅱ)이온과 Fe(Ⅲ)이온의 정량)

  • Lee, Sang Hak;Nam, Myeong Sik
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.6
    • /
    • pp.509-514
    • /
    • 2002
  • A method to determin Fe(II) and Fe(III) ion in aqueous solution by chemiluminescence method using a stopped flow system has been studied. The method is based on the increased chemiluminescence intensity with the addition of Fe(III) ion to a solution of lucigenin and hydrogen peroxide. The effects of KOH concentration, flow rate of reagents, $H_2O_2$ concentration and citric acid concentration used for the masking of Fe(II) ion on the chemilu-minescence intensity have been investigated. The calibration curve for total Fe was linear over the range from 1.0${\times}$$10^{-6}$ M to 1.0${\times}$$10^{-4}$M, coefficient of correlation was 0.996 and the detection limit was 1.0${\times}$$10^{-7}$M under the optimal exper-imental conditions of 4.0 M, 2.0 M, 3.5 mL/min for the concentration of $H_2O_2,$ KOH and flow rate of reagents, respec-tively. The calibration curve for Fe(Ⅲ) was linear over the range from 1.0${\times}$$10^{-6}$M to 1.0${\times}10^{-4}$ M, the coefficient of correlation was 0.997 and the detection limit was 5.0${\times}$$10^{-7}$M under the optimal experimental conditions.

Determination of Tb(III) in aqueous solution by fluorescence spectrometry (형광분광법에 의한 수용액 중의 Tb(III) 정량)

  • Lee, Sang Hak;Bae, Zun Ung;Chung, Hae Young;Choi, Sang Seob
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.274-281
    • /
    • 1997
  • Methods to determine terbium(III) ion in aqueous solution by measuring the enhanced fluorescence intensity of terbium(III)-terephthalic acid(TPA) complex ion have been studied. The optimum analytical conditions for pH, excitation wavelength and concentration of TPA were found to be 6.0, 260nm and $4.0{\times}10^{-4}M$, respectively. The fluorescence intensity of the terbium(III) complex ion was further increased with addition of trioctylphosphine oxide (TOPO). In this case Triton X-100 was used to dissolve TOPO in aqueous solution. When TOPO was used, the optimum analytical conditions for pH, excitation wavelength, and concentrations of TPA, TOPO and Triton X-100 were found to be 4.5, 285nm. $4.0{\times}10^{-4}M$, $5.0{\times}10^{-5}M$, and 0.05%, respectively. Under the optimum experimental conditions, calibration curve for Tb(III) was linear over the range from $4.0{\times}10^{-8}M$ to $4.0{\times}10^{-5}M$ and the detection limit was $4.0{\times}10^{-8}M$. When TOPO was used, the concentration range of linear response, and the detection limit were $4.0{\times}10^{-9}M$ to $2.0{\times}10^{-6}M$, and $4.0{\times}10^{-9}M$, respectively. Effects of interferences from various cations for the determination of terbium(III) ion were also investigated.

  • PDF

Development of the Handy Non-contact Surface Roughness Measurement Device by using the Optical Fiber Sensor (광섬유센서에 의한 간이 비접촉 표면조도 측정기의 개발)

  • Hong, Jun-Hee
    • 대한공업교육학회지
    • /
    • v.34 no.2
    • /
    • pp.346-362
    • /
    • 2009
  • The purpose of this study was to develop the handy non-contact measurement device of the surface roughness by using the optical fiber sensor. The advantages of fiber optic sensors are high-speed responsibility, non-effect of the magnetic, convenience of the product and high precision. The measurement theory for surface roughness of optical fiber sensor is one to one correspondence between the reflected light intensity based on the surface roughness of the object and the measurement value of previously known for surface roughness. The reflected light intensity was determined using the distance to the surface from the sensor probe and the limit reflection angle based on the surface roughness. Therefore, in this study, the sensor probe was produced for determining the value of surface roughness only using the limit reflection angle based on the surface roughness with the fixed distance from the surface. A prototype measurement system was composed of a transmitting part, a receiving part and a signal processing circuit. The materials of standard measurement which was used in this experiment were SM45C, STS303 and Al60. According to the results of this study, approximation surface roughness formulas which was deduced from the correlation of between the standard surface roughness and the sensing output were verified that they were effect against the surface roughness measurement value of the option sample. And handy optical fiber surface roughness measurement device which was produced by an order was verified that it was effect for measuring of the precision surface roughness.

Determination of L-Dopa by Spectrofluorimetry Using Co-fluorescence Enhancer (보조 형광증가제를 이용한 L-Dopa의 형광분광법적 정량)

  • Lee, Sang Hak;Ahn, Jung Mi
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.541-546
    • /
    • 2000
  • Methods to determine L-dopa(L-3,4-dihydroxyphenylalanine) in aqueous solution by spectrofluorimetry based upon the ligand sensitized luminescence of Tb(III) ion L-dopa complex have been studied. Tb(III) ion and Lu(III) ion were used as ligand sensitized fluorescencer and co-fluorescence enhancer, respectively. The effects of excitation wavelength, pH, concentration of Tb(III) ion, concentration of Lu(III) ion and emission wavelength on the fluorescence intensity were investigated. The fluorescence intensity of the Tb(III) ion L-dopa complex was further increased with addition of Lu(III) ion. The calibration curve for L-dopa was linear over the range from 5.0 ${\times}$ $10^{-7}$ M to 1.0${\times}$ $10^{-4}$ M and the detection limit was 4.0 ${\times}$ $10^{-8}$ M under the optimal experimental conditions of 300 nm, 8.0, 1.0 ${\times}$ $10^{-4}$ M and 545 nm for excitation wavelength, pH, concentration of Tb(III) ion and emission wavelength, respectively. When Lu(III) ion was added to Tb(Ⅲ) ion L-dopa complex, the concentration range of linear response and detection limit were 1.0${\times}$$10^{-8}$ M to 2.0 ${\times}$ $10^{-4}$ M and 1.0 ${\times}$ $10^{-9}$ M, respectively under the optimal experimental conditions of 300 nm, 8.5, 1.0 ${\times}$ $10^{-5}$ M, 1.0 ${\times}$ $10^{-5}$ M, 545 nm for excitation wavelength, pH, concentration of Tb(III) ion, concentration of Lu(III) ion and emission wavelength, respectively.

  • PDF

Calculation of Expected Life of Hydrogen Pressure Vessels by Fracture and Fatigue Mechanics assuming Semi-elliptical Cracks and Analysis of the Effect of Thickness and Radius (반타원형 균열을 가정한 파괴 및 피로역학에 의한 수소 압력용기의 예상 수명 계산과 두께와 내경이 미치는 영향 분석)

  • Kim, Jeong Hwan;Lee, Hwa Young;Lee, Min-Kyung;Lee, Jae-Hun;Lyu, Geunjun
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.53-65
    • /
    • 2021
  • While the hydrogen refueling station is rapidly expanded and installed, the safety inspection of the hydrogen pressure vessel in the station should be very important. Of these, according to ASME, hydrogen embrittlement tests must be performed for hydrogen vessel that store hydrogen above a certain pressure. The main test method for hydrogen embrittlement inspection is to carry out fracture tests and fatigue fracture tests in a high pressure hydrogen atmosphere, which allows the durability limit of the pressure vessel to be measured and the endurable limit to be determined in the hydrogen atmosphere. In detail, the critical crack depth can be calculated by the stress intensity factor(K), and the service life can be determined by da/dN (fatigue growth rate). API579-1/ ASME FFS-1 part 9 exemplifies the calculation method according to the mode of crack-like flaws, but for various shapes such as plates and cylinders, there are about 55 modes according to the shape and location of the crack. Due to the fairly complex formula, it is not easily accessible. In this study, we will show you how to calculate fracture mechanics numerically via Excel and VBA. In addition, this was applied to analyze the effects of the thickness and inner diameter of the pressure vessel on the service life.