• Title/Summary/Keyword: Intensifying Screen

Search Result 25, Processing Time 0.027 seconds

Research on the Actual Condition of Intensifying Screens (증감지감도(增減紙感度)의 실태(實態)에 대한 조사(調査))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Kim, Sung-Hoon;Yoon, Han-Sik;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.5 no.1
    • /
    • pp.45-47
    • /
    • 1982
  • Authors carried out the research on the actual condition of intensifying screens in a certain hospital and obtained the results as follows: 1. High speed intensifying screens were 63.9% and medium typed screen had 36.1%. 2. Half the number of using screens(51.5%) were not clear in a period of used time. 3. 47.4% of same typed screens showed a remarkable difference(two times) in sensitivity.

  • PDF

Image Enhancement of Image Intensifying Device in Extremely Low-Light Levels using Multiple Filters and Anisotropic Diffusion (다중필터와 이방성 확산을 이용한 극 저조도 조건에서의 미광증폭장비 영상 개선)

  • Moon, Jin-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.36-41
    • /
    • 2018
  • An image intensifying device is equipment that makes weak objects visible in a dark environment, such as making nighttime bright enough to let objects be visually observed. It is possible to obtain a clear image by amplifying the light in the presence of a certain amount of weak light. However, in an extremely low-light environment, where even moonlight is not present, there is not enough light to amplify anything, and the sharpness of the screen deteriorates. In this paper, a method is proposed to improve image quality by using multiple filters and anisotropic diffusion for output noise of the image-intensifying device in extreme low-light environments. For the experiment, the output of the image-intensifying device was obtained under extremely low-light conditions, and signal processing for improving the image quality was performed. The configuration of the filters for signal processing uses anisotropic diffusion after applying a median filter and a Wiener filter for effective removal of salt-and-pepper noise and Gaussian noise, which constitute the main noise appearing in the image. Experimental results show that the improvement visually enhanced image quality. Both peak signal-to-noise ratio (PSNR) and SSIM, which are quantitative indicators, show improved values.

Study on the X-ray Spectra Dependence for Intensifying Screens (증감지의 X선 Spectra 의존성에 관한 연구)

  • 김영근;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.93-96
    • /
    • 1998
  • The X-ray spectra dependence for intensifying screens of medical radiography was investigated through analysis of the absorbed coefficiency(${\mu}$), absorbed efficiency(η$\sub$${\alpha}$/) and absorbed ratio(R). It was found that the absorbed coefficiency was increased in the order of CaWO$_4$$_4$ screen showed the highest value.

  • PDF

Studies on Effective Utilization of X -ray Energy Using Intensifying Screens (증감지의 X-선 에너지 유효 이용에 관한 연구)

  • Kim, Y.K.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.825-828
    • /
    • 1998
  • The X-ray spectra dependence for intensifying screens of medical radiography was investigated through analysis of the absorbed coefficiency($\mu$), absorbed efficiency(${\eta}_{\alpha}$) and absorbed ratio(R). It was found that the absorbed coefficiency was increased in the order of $CaWO_4$$CaWO_4$ screen showed the highest value.

  • PDF

The Study on Quantum Efficiency of $CaWO_4$ Screen with Diagnostic X-ray (진단 X선에 대한 $CaWO_4$ 증감지의 양자효율 연구)

  • Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.379-382
    • /
    • 2002
  • Lately, intensifying screen of the $CaWO_4$ is used to medical treatment and diagnosis of the image. In this paper, we investigated transmission fraction and mass attenuation coefficient of $CaWO_4$ screen about diagnostic x-ray of low energy using MCNP 4C code. Experimentally, for 0.9 mm-$CaWO_4$ screen, the absorbable rate of diagnostic x-ray is more than 95%. according to kVp, the experimental value of mass attenuation coefficient is in a1most agreement with an corrected estimate value of MCNP and the deviation of experimental values is less than ${\pm}7%$. Using the MCNP code through this paper, we can make an estimate of signal and design for construction of the CaWO4/a-Se based digital x-ray image detector and make a good use of the foundation data for development of other materials.

  • PDF

Effect of Intensifying Screens to Subject Contrast (증감지에 따른 피사체 대조도의 변화)

  • Lee, In-Ja;Huh, Joon;Kang, Hong-Seok;Yoon, Chul-Ho
    • Journal of radiological science and technology
    • /
    • v.13 no.2
    • /
    • pp.27-30
    • /
    • 1990
  • It is an experimental report about object contrast according to the Kinds of screen and obtained results as follows : 1. In the same object radiography, use acquired the difference of the object contrast between LT-II ($CaWO_{4}\;system$) and G4 (Gd system) screens. 2. object contrast more decreased in Gd system screen than $CaWO_{4}$, and object contrast controlled by X-ray tube voltage. 3. The difference of object contrast seen clearly in 80 kVp.

  • PDF

Defect Analysis of Gd2O2S : Tb Using Coincidence Doppler Broadening Positron Annihilation Spectroscopy (Gd2O2S:Tb의 동시 계수 도플러 양전자 소멸법에 의한 결함 특성)

  • Lee, C.Y.;Bae, S.H.;Kim, J.H.;Kwon, J.H.
    • Korean Journal of Materials Research
    • /
    • v.16 no.7
    • /
    • pp.455-459
    • /
    • 2006
  • Coincidence Doppler Broadening (CDB) of positron annihilation spectroscopy was applied to analyze defects in the chemical state of Department of Physics, $Gd_2O_2S$:Tb intensifying screens. The screen samples were irradiated by 80 MV X-rays in hospital and were used for 0, 2, 4, and 6 years respectively. There was a positive relationship between the S-parameter values and time of exposure to X-rays. Most of the defects were indicated to have been generated by X-rays. A 1D CDB was developed in order to reduce the background noise, and the S-parameter values of the $Gd_2O_2S$:Tb intensifying screens, using the 1D CDB, varied between 0.4974 and 0.4991.

Fabrication of Bendable Gd2O2S:Tb Intensifying Screen and Evaluation of Fatigue Properties (유연한 Gd2O2S:Tb 증감지 제작 및 피로누적에 대한 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jeon, Je-Hoon;Kim, Joo-Hee;Heo, Ye-Ji;Kang, Sang-Sik;Kim, Kyo-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.611-617
    • /
    • 2017
  • In this study, it was expected that long-term stability against external mechanical external force could be secured if the phosphor layer had ductility. In this study, a bendable $Gd_2O_2S:Tb$ sensitized paper was fabricated by screen printing method and the image uniformity was evaluated through RMS analysis and histogram analysis to investigate the effect of fatigue accumulation due to long-term external force and repetitive external force. As a result, the dominant pixel area is maintained constant and the relative standard deviation is less than 10% for the long-term external force. However, for the repetitive external force, the dominant pixel area is divided into three areas and the image uniformity is adversely affected. Based on these results, it is suggested that the curved surface detector can be applied by securing the mechanical stability against the existing radiation sensitized paper. However, further studies are needed to apply it to the flexible detector. As a result, flexible radiation sensitizers can be applied to various curved surfaces, and it is expected to be applicable to various fields such as nuclear medicine, medical treatment, and industrial fields in the future.

A Study on the Reduction of Exposure Dose and Contrast Improvement by Use of Heavy Elements Filter (X선 진단영역에서 중원소(Ho) 여과판 사용에 따른 피폭선량 감소와 대조도 개선에 관한 연구)

  • Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.91-96
    • /
    • 2000
  • This work was on the reduction of exposure dose and contrast improvement by Use of Heavy Elements Filter From the result of experimental evaluation, it was found that the beam harding of X-ray was not showed in Ho and Gd, heavy elements filters, contrast to Cu and Al filters In which the harding showed. And the ratio of transit dose to surface dose and the load of X-ray tube increase in order of Al, Cu, Gd and Ho, respectively. The contrast of X-ray images using the intensifying screen and the input phosphor showed the higher value in order of Cu, Al, Gd and Ho. Therefore, in the case of using contrast media and phosphor in region of diagnostic radiology, X-ray image quality depends primarily on kVp and heavy elements filters.

  • PDF