• 제목/요약/키워드: Intensifier

검색결과 78건 처리시간 0.023초

The Performance of Heavy Ion CT System with Fluorescent Screen and CCD Camera

  • Tomida, Tetsuya;Nishimura, Katsuyuki;Abe, Shinji;Sato, Hitoshi;Muraishi, Hiroshi;Inada, Tetsuo;Tazawa, Shuichi;Kanai, Tatsuaki;Yusa, Ken;Kawachi, Kiyomitsu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.432-435
    • /
    • 2002
  • We have developed and proposed the heavy ion CT system which consists of fluorescent screen and CCD camera equipped with image intensifier. In our system, we have measured the residual range of particles that passed a phantom and reconstructed the CT image for the distribution of relative stopping power by filtered back projection method with Shepp '||'&'||' Logan filter. The heavy ion $\^$12/C accelerated up to 400 MeV/u by HIMAC (Heavy Ion Medical Accelerator in Chiba) was used. Intensity of the beam output changes like macro pulse, the period being 3.3 sec and the width being 2 sec. The series of data was acquired in synchronizing with the pulse, leading to the improvement of S/N in the CT image. The fundamental performance was experimentally evaluated in the proposed system. The spatial resolution was estimated to be about 1 mm and the density resolution (electron density referred to water) to be about 0.01.

  • PDF

감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가 (Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution)

  • 신상훈;유욱재;장경원;조승현;이봉수
    • 센서학회지
    • /
    • 제24권3호
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.

복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구 (Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy)

  • 홍선숙;강경미;성민숙;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

X-ray microtomography를 이용한 치아의 3차원 재구성 (THREE DIMENSIONAL RECONSTRUCTION OF TEETH USING X-RAY MICROTOMOGRAPHY)

  • 신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권6호
    • /
    • pp.485-490
    • /
    • 2003
  • Complete understanding of the exterior and interior structure of the tooth would be prerequisite to the successful clinical results, especially in the restorative and endodontic treatment. Although three-dimensional reconstruction method using x-ray microtomography could not be used in clinical cases, it may be the best way to reconstruct the morphologic characteristics of the tooth structure in detail without destructing the tooth itself. This study was done to three dimensionally reconstruct every teeth in the arch in order to increase the understanding about the endodontic treatment and to promote the effective restorative treatment by upgrading the knowledge of the tooth morphology. After placing tooth between the microfocus x-ray tube and the image intensifier to obtain two-dimensional images of each level. scanning was done under the condition of 80 keV, $100{\;}\mu\textrm{m}$, 16.8 magnification with the spot size of $8{\;}\mu\textrm{m}$. Cross-section pixel size of $16.28{\;}\mu\textrm{m}$ and 48.83 cross-section to cross-section distance were also used. From the results of this study, precise three dimensional reconstructed images of every teeth could be obtained. Furthermore, it was possible to see image that showed interested area only, for example. enamel portion only, pulp and dentin area without enamel structure, pulp only, combination image of enamel and pulp, etc. It was also possible to see transparent image without some part of tooth structure. This image might be used as a guide when restoring and preparing the full and partial crown by showing the positional and morphological relationship between the pulp and the outer tooth structure. Another profit may be related with the fact that it would promote the understanding of the interior structure by making observation of the auto-rotating image of AVI file from the various direction possible.

두개부 혈관 조영검사 시 기하학적 특성에 따른 선량 감소 방안 (Dose Reduction According to Geometric Parameters of Digital Cerebral Angiography)

  • 박찬우;조평곤
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.399-406
    • /
    • 2019
  • 본 연구의 목적은 디지털 혈관 조영 촬영장치를 이용한 검사 시 X선관, 환자 테이블, 검출기 또는 환자 등의 기하학적 특성에 따라 실무자가 수시로 변화시켜 적용할 수 있는 매개변수에 대해 알아보고 이에 따른 환자 및 의료진의 방사선 피폭선량을 감소시키는 방안에 대해 알아보고자 하였다. 기하학적 특성들에 따라 각각 fluoroscopy mode와 Digital subtraction angiography로 촬영하고 유효 선량으로 환산한 값을 비교하였다. 연구결과 FPS mode에 따른 선량은 FPS mode를 낮게 설정할수록 선량이 30-40%까지 감소하였다. X선관 각도에 따른 선량은 AP View에서 가장 높게 측정되었고 머리 방향으로 각도가 들어갈수록 선량이 낮게 측정되었다. FOV가 확대될수록 선량이 1.2-1.6배 증가하였고 X선관과 테이블의 거리가 가까워질수록 약 10% 증가하였다. X선관과 평판형 검출기의 거리가 100 mm 멀어질수록 선량이 20-30% 증가하였다. 결론적으로 혈관 조영검사 시 다양한 기하학적 특성들은 실무자가 수시로 변화시켜 적용할 수 있는 매개변수이며 다양한 상황에서 적합한 기하학적 특성들을 고려하여 적용함으로써 적절한 선량 감소 효과를 기대할 수 있다.

고에너지 광자선속에서 TLD-100 chip 위에 있는 금박막(140 ${\mu}{\textrm}{m}$) 역할 (The Roles of Gold Plate (140${\mu}{\textrm}{m}$) Loaded on TLD-100 Chips in the High Energy Radiation Beams)

  • Vahc, Young-Woo;Park, Kyung Ran.
    • 한국의학물리학회지:의학물리
    • /
    • 제6권2호
    • /
    • pp.51-60
    • /
    • 1995
  • 고에너지 (6-15MV) 광자선속으로 치료할때 LiF(TLD-100) 결정은 solid water phantom 이나 환자의 피부 표면에서의 흡수선량을 측정하기 위해 열자극 발광 선량계(이하 NC-100)가 주로 사용된다. 통상 NC-100은 가열 과정을 여러회 반복하면 그 감도가 줄어드는 것으로 조사되었다. NC-100 위에 입사 광자선속 방향으로 올려놓은 140$\mu\textrm{m}$ 두께의 금박막(이하 GC-100)은 NC-100 과 다른 성질을 갖는다. 즉, 광자선속에서 GC-100 은 금박막에서 주로 쌍생성이 일어나고 부분적으로 Compton 산란이 일어나 많은 양전자와 음전자를 만들어 낸다. 그 결과 TLD-100 결정은 증가된 신호를 갖고(최대 100% 증가), 흡수 선량당 높은 반응도가 좋은 선형도를 갖으며, 선량물에 무관할 뿐만 아니라 Fluctuation error 도 $\pm$0.5% 미만으로 낮게 측정되었다. GC-100 은 주로 쌍생성이 일어나기 때문에 전자선보다 광자선에서 더욱 감도가 좋은것으로 나타난다. 그것은 금과같이 원자번호가 높은 매질에서 광자선에 의한 쌍생성의 확률이 큰것에 기인한다. 치료용 고에너지 광자선속에서 TLD-100 chip 위에 올려진 금박막은 TLD 의 신호를 크게 증가시키는 역할을 하는것으로 나타났다.

  • PDF

견봉 쇄골 관절 탈구에 대한 견봉 쇄골 관절의 관혈적 정복술 (Open Reduction of Acromioclavicular Joint for the Acromioclavicular Joint Dislocations)

  • 송현석;최남용;한석구;나기호;남원식;양혁재;박성진
    • Clinics in Shoulder and Elbow
    • /
    • 제9권2호
    • /
    • pp.189-195
    • /
    • 2006
  • Purpose: To analyze the result of the accurate open reduction of acromioclavicular (AC) joint and pin fixation, coracoclavicular (CC) screw fixation without CC ligament repair for AC joint injuries. Materials and Methods: Between January 2000 and December 2003, seventeen cases with at least one year follow-up among twenty-one cases underwent operation for AC-CC ligament injuries. A transverse incision approximately 5 cm in length was made over the clavicle, and the AC joint was reduced accurately. Under the image intensifier, a cannulated screw and washer were inserted for the CC ligament. Two Steinman pins were inserted for the AC joint and the AC ligament was repaired with nonabsorbable suture. Gentle passive range of motion was begun postoperative 2 weeks. The pins were removed at $6{\sim}8$ weeks and the screw was removed at $10{\sim}12$ weeks. The results were evaluated by a distance between AC and CC joints on plain films and ASES score at last follow-up. Results: At the last follow-up, there was no limitation of motion and average ASES score was 96($86{\sim}100$ points). There was no failure showing over 5 mm difference of distance compared to opposite side on the plain films. Seven cases had the skin damages and local infection due to pin migration and three cases showed the loosening of CC screw. Conclusion: We could have satisfactory results by accurate reduction of AC joint and simple pins and screw fixation for AC-CC ligament injuries.

Ender Nail을 이용한 경골간부 골절의 치료 (Treatment of the Tibia Shaft Fractures with Ender Nails)

  • 김인기;이동철;서재성;안면환;김세동;안종철
    • Journal of Yeungnam Medical Science
    • /
    • 제9권1호
    • /
    • pp.130-136
    • /
    • 1992
  • 본 영남대학교 의과대학 부속병원 정형외과에서는 1986년 12월에서 1991년 11월까지 경부 간부 골절 31례에 대하여 Ender nail을 시행하여 다음과 같은 결과를 얻었다. 1. 환자의 평균연령은 37.3세였고, 남자에게서 3배가 많았으며, 교통사고가 가장 많은 원인이었다(67%). 2. 폐쇄성 골절이 20례, 개방성 골절이 11례였으며, 분쇄골절과 분절골절이 18례(57.7%)였고, 중간부 골절이 16례로 가장 많았다. 3. 동반손상이 19례에서 있었고, 수상후 수술까지의 기간은 평균 7.6일이었다. 4. 평균 골유합 기간은 18.9주였으며, 2례에서 지연유합을 보였다. 5. 합병증으로 하지 단축이 2례, 각형성 변형이 3례, 관절 운동 제한 2례, 감염이 연부조직에 1례 있었다. 이상 경골 간부골절 치료에 사용한 Ender nail은 시술의 간편성, 적절한 고정성과 운동성, 비교적 폭넓은 적용 범위등으로 좋은 치료 결과를 기대할 수 있는 방법으로 사료된다.

  • PDF

IVR장치의 성능 평가 기준 개발 (Establishment of Quality Control System for Angiographic Unit)

  • 강병삼;손진현;김승철
    • 한국콘텐츠학회논문지
    • /
    • 제11권1호
    • /
    • pp.236-244
    • /
    • 2011
  • 성능이 저하된 IVR 장치의 지속적 사용은 환자 및 시술자의 방사선 피폭을 증가시킬 뿐 아니라, 잘못된 영상정보를 제공함으로써 환자에게 심각한 영향을 끼칠 수 있다. 따라서 이번 연구에서는 IVR장치의 성능평가를 위한 적절한 시험방법 및 검사기준을 마련하고자 하였다. IVR장치의 국내현황 및 규격을 조사하였으며, 표준팬텀을 이용하여 국내 IVR장치의 성능을 현장 측정함으로써, 국내 실정에 맞는 적절한 IVR 장치의 화질 및 성능평가 기준을 설정하였다. 장치의 기본적 성능에 관한 검사를 위해 관전압시험, 관전류 시험, 반가층 시험을 실시하며, NEMA stndard XR-21 Phantom을 표준팬텀으로 사용하여 화질 및 선량 평가를 하도록 하였다. 표준팬텀을 이용한 검사항목은 image-field geometry, spatial resolution, low-contrast iodine detectability, wire resolution, phantom entrance dose이다. 또한 매일, 매주, 1개월, 3개월, 6개월 및 1년 주기의 평가항목을 설정하였다. 장치의 성능기준은 진단용방사선안전관리 규정을 준용하여 kVp시험은 평균오차 ${\pm}10%$, mA시험은 평균오차 ${\pm}15%$, 반가층시험은 80kVp에서 최소 2.3mmAl으로 설정하였다. 표준팬텀의 검사기준은 image-field geometry에서 최소 acceptable이 나와야 하며, spatial resolution은 Image Intensifier 나 detector 크기기준으로 34-40cm은 0.8 lp/mm, 28-33cm은 1.0lp/mm, 22-27cm은 1.2 lp/mm이상이 나와야 한다. low contrast iodine detectability는 최소농도 200mg/cc 이상 보여야 하며, phantom entrance dose는 10R/min을 초과해서는 안 된다. Wire resolution은 정지 상태에서 최소 0.012인치까지 보여야 하며, 움직일 때 최소 0.022인치까지 보여야 한다.

다호리 출토 칠초철검(漆鞘鐵劍)의 보존 (Conservation of Iron Dagger & Scabbard Excavated in Daho-ri, Changwon)

  • 심명보;임지현;마대완;김미도리
    • 박물관보존과학
    • /
    • 제12권
    • /
    • pp.19-24
    • /
    • 2011
  • 국립김해박물관에서 발굴 조사가 이루어진 창원 다호리 유적에서 칠기검집에 철검이 끼워져 있는 상태의 칠초철검(漆鞘鐵劍)이 출토되어 이에 대한 보존처리 과정을 소개하고자 한다. 부식되어 상태가 취약한 청동제검심(劍鐔)은 강화제로 사용 중인 Incralac을 도포한 후 현미경을 이용하여 표면의 문양을 노출하였다. 칠기검집의 표면은 이물질을 제거함과 동시에 HPC 2% 수용액를 도포하여 피막을 보호하였다. 이물질 제거가 완료된 칠 표면에는 Caparol binder 5% 수용액를 2~3회 도포하여 보호피막을 형성한 다음 한지와 알루미늄 호일로 감싸 주었다. 이후 우레탄폼으로 유물을 안전하게 고정한 후 뒤집어 뒷면을 위와 같은 방법으로 보존처리를 실시하였다. 두께가 얇은 유물을 지지하기 위해 검집의 뒷면에 한지를 3겹으로 붙여 힘을 받을 수 있도록 하였으며, 내부의 철검은 검집에 도포한 HPC 2% 수용액를 주입하여 굳히는 정도로 마무리하였다. 이후 투명 아크릴 상자에 보관하여, 향후 전시 등에 활용될 수 있도록 하였다.