• 제목/요약/키워드: Integrated power system

검색결과 1,464건 처리시간 0.026초

Battery Energy Storage Based Voltage and Frequency Controller for Isolated Pico Hydro Systems

  • Singh, Bhim;Rajagopal, V.
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.874-883
    • /
    • 2009
  • This paper deals with an integrated voltage and frequency (VF) controller for isolated asynchronous generators (IAG) driven by a constant power pico-hydro uncontrolled turbine feeding three-phase four-wire loads. The proposed VF controller is used to control the frequency and voltage of an IAG with load leveling. Such a VF controller is also known as an integrated electronic load controller (IELC) which is realized using an isolated star/polygon transformer with a voltage source converter (VSC) and a battery at its DC bus. The proposed generating system with a VFC is modeled and simulated in MATLAB along with Simulink and Simpower system (SPS) toolboxes. The simulated results are presented to demonstrate the performance of an isolated asynchronous generator feeding three-phase four-wire loads with neutral current compensation.

태양광 발전 시스템용 AC 모듈 집적형 전력변환기의 구성 방식에 따른 손실 분석 (Loss Analysis according to Configuration Method of AC Module Integrated Converter for Photovoltaic System)

  • 강승현;손원진;안상준;이병국
    • 전력전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.311-318
    • /
    • 2020
  • A photovoltaic (PV) system uses an AC module integrated converter (MIC) to operate PV cells at a maximum power point (MPP) and for high efficiency. The MPP of a PV cell varies depending on partial shading conditions, and loss occurs differently according to the configuration method of the PV-MIC. Therefore, this study compares the losses of passive components and power semiconductors according to the partial shading conditions of the PV module. Theoretical loss analysis is performed using parameters for the datasheet and PSIM simulation results. Analysis results verify that the one-stage PV-MIC demonstrates high efficiency.

군 이동기지국시스템(MSAP) 통합전원제어장치 배터리 충전용 1.5kVA급 무선전력전송기기의 설계 (Design of the 1.5kVA Class Wireless Power Transfer Device for Battery Charging of Integrated Power Control System in MSAP)

  • 김진성;김병준;박현정;서민성
    • 한국전자통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.413-420
    • /
    • 2020
  • 군 전술정보통신체계(TICN: Tactical Information and Communication Network)는 이동기지국시스템(MSAP: Mobile Subscriber Access Point)을 활용하여 음성 및 데이터 등 실시간 멀티미디어 서비스를 제공한다. 이때 소용량 무선전송체계와 대용량 무선전송체계를 통해 외부전송로를 구성하게 된다. 각 무선전송체계의 통신기기들은 전술차량에 탑재되고 전술차량에 공급전원이 통합전원제어장치로 절체 될 때 전원차단을 예방하기 위해 2차전지가 사용된다. 본 논문은 이동기지국시스템 통합제어장치 배터리 충전용 무선전력전송기기를 장하분배법을 이용하여 기본 설계하고 공극에 의한 설계 변수인 1차 측 권선 수와 코어 재질선정을 FEM(Finite Elements Method) 해석을 통해 확인하였다.

윈도우즈 기반의 교류 전기철도 급전시스템 통합 시뮬레이터 개발 (Development of Integrated Simulator for AC Traction Power Supply System)

  • 김주락;김정훈
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.76-81
    • /
    • 2010
  • This paper describes the development of integrated simulator with GUI(Graphic User Interface) for traction power supply system. This simulator consists of a lot of calculation modules such as TPS, train time schedule, line constant, and power supply system analysis. Each module has input and output structure respectively. The algorithms of all modules have confirmed the validity to comparison with field test that is performed on both high speed railway line and conventional line.

A COMPARATIVE OVERVIEW OF THERMAL HYDRAULIC CHARACTERISTICS OF INTEGRATED PRIMARY SYSTEM NUCLEAR REACTORS

  • NINOKATA HISASHI
    • Nuclear Engineering and Technology
    • /
    • 제38권1호
    • /
    • pp.33-44
    • /
    • 2006
  • This paper presents a review of small-to-medium-sized, pressurized-water-cooled nuclear power reactors whose major primary coolant systems are integrated into a reactor pressure vessel, the concepts categorized as Integrated Primary System Nuclear Reactors (IPSRs). Typical examples of these proposals of interest in this review are CAREM, SMART, IRIS and IMR, all of which are being aimed at the near term deployment. Emphasis is placed on thermal hydraulic aspects. A brief characterization of the IPSR concepts is made and comparisons of plant key parameters are shown. Discussions will follow for the core cooling under rated power conditions and natural circulation heat removal on the basis of the design data available in the public domain.

Design and Implementation of a Universal System Control Strategy Applicable to VSC-HVDC Systems

  • Zhao, Yue;Shi, Li-bao;Ni, Yi-xin;Xu, Zheng;Yao, Liang-zhong
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.225-233
    • /
    • 2018
  • This paper proposes a universal system control strategy for voltage source converter (VSC) based high voltage direct current (HVDC) systems. The framework of the designed control strategy consists of five layer structures considering the topology and control characteristics of the VSC-HVDC system. The control commands sent from the topmost layer can be transmitted to the next layer based on the existing communication system. When the commands are sent to each substation, the following transmission of commands between the four lower layers are realized using the internal communication system while ignoring the communication delay. This hierarchical control strategy can be easily applied to any VSC-HVDC system with any topology. Furthermore, an integrated controller for each converter is designed and implemented considering all of the possible operating states. The modular-designed integrated controller makes it quite easy to extend its operating states if necessary, and it is available for any kind of VSC. A detailed model of a VSC-HVDC system containing a DC hub is built in the PSCAD/EMTDC environment. Simulation results based on three operating conditions (the start-up process, the voltage margin control method and the master-slave control method) demonstrate the flexibility and validity of the proposed control strategy.

A Fully-Integrated Penta-Band Tx Reconfigurable Power Amplifier with SOI CMOS Switches for Mobile Handset Applications

  • Kim, Unha;Kang, Sungyoon;Kim, Junghyun;Kwon, Youngwoo
    • ETRI Journal
    • /
    • 제36권2호
    • /
    • pp.214-223
    • /
    • 2014
  • A fully-integrated penta-band reconfigurable power amplifier (PA) is developed for handset Tx applications. The output structure of the proposed PA is composed of the fixed output matching network, power and frequency reconfigurable networks, and post-PA distribution switches. In this work, a new reconfiguration technique is proposed for a specific band requiring power and frequency reconfiguration simultaneously. The design parameters for the proposed reconfiguration are newly derived and applied to the PA. To reduce the module size, the switches of reconfigurable output networks and post-PA switches are integrated into a single IC using a $0.18{\mu}m$ silicon-on-insulator CMOS process, and a compact size of $5mm{\times}5mm$ is thus achieved. The fabricated W-CDMA PA module shows adjacent channel leakage ratios better than -39 dBc up to the rated linear power and power-added efficiencies of higher than around 38% at the maximum linear output power over all the bands. Efficiency degradation is limited to 2.5% to 3% compared to the single-band reference PA.

전력자동화서비스를 위한 지능형 통합 게이트웨이 설계 (The Design Efforts of the Intelligent & Integrated Gateway System for the Automation Systems in Electric Power Companies)

  • 김명수;현덕화;조선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2448-2450
    • /
    • 2002
  • In recent years, it has been a worldwide trend that many power utilities gave their attention to develop and operate their power plants, substation and distribution systems. Following this trend, KEPCO(Korea Electric Power Corporation) has developed many electric automation systems with various communication networks. It has been natural that the automation systems are just focused on to remote devices when they come to be designed. But, we have to shirt the focus to the automation system itself. There are many problems in maintenance and integration of the automation systems. When an automation system can't control some remote devices, there is no way to get why and which part(Master, Network, Master-side Modem or Remote-side modem, Remote Device, etc.) of the system has problems. Moreover the system just directly links to another automation system. If the system has to link many systems, it needs the linker per each systems. So, we need a new concept to resolve that problems, and develop the Intelligent and Integrated Gateway(IIG) for the automation systems for easy maintenance and integration.

  • PDF

연료전지 전력 시스템의 모델링 (The Modeling of Power System with PEM fuel cell)

  • 한경희;이화진;이나영;장혜영;이병송;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.239-241
    • /
    • 2008
  • A powered system with fuel cell is regarded as a high current and low voltage source. Effects of the loads on the electrical power source are important to optimize the integrated power system. The design parameters of the system should be chosen by taking into account the characteristics of the fuel cell, so the costs of the power system at given operating conditions can be reduced. Furthermore, the dynamics characteristic of the system is crucial to acquire performance in applications, particularly interactions between loads and the fuel cell system. Currently, no integrated simulation has been approached to analyze interrelated effects. Therefore, the dynamic models of power conversion system with a PEM fuel cell that includes the PEM fuel cell stack, DC/DC converter and associated controls is developed. Electric lads for the system are derived by using a power theory that separates a load current into active, reactive, distortion or a mixed current component. Dependency of the DC capacitor on the loads are analyzed.

  • PDF

Performance Ratio of Crystalline Si and Triple Junction a-Si Thin Film Photovoltaic Modules for the Application to BIPVs

  • Cha, Hae-Lim;Ko, Jae-Woo;Lim, Jong-Rok;Kim, David-Kwangsoon;Ahn, Hyung-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권1호
    • /
    • pp.30-34
    • /
    • 2017
  • The building integrated photovoltaic system (BIPV) attracts attention with regard to the future of the photovoltaic (PV) industry. It is because one of the promising national and civilian projects in the country. Since land area is limited, there is considerable interest in BIPV systems with a variety of angles and shapes of PV panels. It is therefore expected to be one of the major fields for the PV industry in the future. Since the irradiation is different from each installation angle, the output can be predicted by the angles. This is critical for a PV system to be operated at maximum power and use an efficient design. The development characteristics of tilted angles based on data results obtained via long-term monitoring need to be analyzed. The ratio of the theoretically available and actual outputs is compared with the installation angles of each PV module to provide a suitable PV system for the user.