• 제목/요약/키워드: Integrated management of green space

검색결과 11건 처리시간 0.023초

녹지총량제의 국외사례 및 국내 적용가능성 (Feasibility Study on the Introduction of No Net Loss of Green)

  • 최재용;이동근;김은영;최인태
    • 한국환경복원기술학회지
    • /
    • 제11권2호
    • /
    • pp.104-113
    • /
    • 2008
  • Due to the increasing needs of land supply, green space has been continuously encroached and resulted considerable naturality deterioration in Korea. In order to overcome the problem, it is necessary to introduce a integrated system for managing the quantitative and qualitative aspects of green space. With this regard, this study is to derive the feasibility for the adoption of the 'no net loss of green' policy to Korea from German and Japanese experiences. In Germany, natural resources are protected and inevitable damages were compensated through the adoption of 'interference regulation'. In Japanese case, future green space and artificial green foundation should be specified on the green basic plan which pursuit the improvement of naturality. In order to introduce the 'no net loss of green' policy to Korea, not only awareness raising on integrated green management system but also amendment of related regulations are needed. In detail, restoration and recovery on the damaged nature should be clearly elucidated and indicators to evaluate the current naturality and calculation methods for the restoration should be developed. Should this integrated green management system introduced, deterioration of naturality by development activities could be minimized thorough the adoption of land development permission criteria and green space management methodologies.

국토계획과 환경계획 통합관리 지표 개발 연구 (A Study on Assessment Indicators for Integrated Management on Korea National Planning and Environmental Planning)

  • 허한결;성현찬;이동근;허민주;박진한
    • 한국환경복원기술학회지
    • /
    • 제21권3호
    • /
    • pp.27-45
    • /
    • 2018
  • Both the national land plan and the environmental plan reflect the need for sustainable land use and management. However, the linkage between the plans is reduced due to the lack of integrated management. Therefore, this study developed indicators to achieve integrated management. A total of 59 environmental plans were reviewed for the development of indicators, and a total of 74 integrated management indicators were derived through a three-stage process. In this process, the relevance of the integrated management indicators of this study to the UN 's sustainable development goals (SDGs) is presented in order to derive indicators that meet the level of international consultation. In order to facilitate the utilization of the indicators, the final indicators are divided into seven areas: natural ecology, water resource and quality, urban and green space, atmospheric, energy, landscape, resource circulation and waste. Furthermore, the indicators were classified into national, regional, and city level. Accordingly, the final indicator can be adapted to the field of influence of the planned to be established, and the indicator can be selected and applied to the level of the plan. The final indicators can be used to examine the extent to which the national plan reflects the contents of the environmental plan and can be used as an aid to confirm the contents to be included in the plan when establishing a new national plan.

대구광역시 공원형 녹지의 기능적 특성을 고려한 종합 평가 (An Integrated Assessment of Park-Type Green Space Considering Functional Characteristics in Daegu)

  • 이우성
    • 한국지리정보학회지
    • /
    • 제19권1호
    • /
    • pp.120-140
    • /
    • 2016
  • 본 연구의 목적은 효율적인 녹지의 계획 및 관리방향 설정을 위한 기초자료 제공을 위해 녹지의 기능적 평가를 실시하는 것이다. 이를 위해 연구대상지를 대구광역시 공원형 녹지로 설정하였으며, 녹지의 기능은 자연생태적, 환경조절적, 이용적 기능으로 제한하였다. 선행연구 고찰 및 전문가 설문조사에 의한 MCB 분석을 통해 13개 지표를 선정하였으며, 전문가 설문조사에 의한 AHP 분석을 통해 기능별 지표의 가중치를 설정하였다. 공원형 녹지의 기능별 평가 결과를 살펴보면, 자연생태적 기능 평가에서는 냉천유원지, 대구체육공원, 달창유원지의 녹지 평가 점수가 80점 이상으로 높게 분석되었다. 환경조절적 기능 평가의 경우 복현공원, 만촌공원, 천내공원 등 15개 녹지의 평가 점수가 75점 이상으로 높게 나타났고, 이용적 기능 평가에서는 수성공원, 달성공원, 월배공원 등 11개 공원형 녹지의 점수가 80점 이상으로 높게 평가되었다. 이러한 분석결과들은 향후 공원형 녹지의 신규 조성, 지속적인 관리 및 리모델링이 요구될 경우 효율적인 기초자료 및 가이드라인으로 활용될 수 있을 것으로 판단된다.

지속가능한 발전을 위한 대도시 외연부 녹지 활용 사례연구 - 베를린, 밀라노, 서울을 대상으로 - (Green Spaces in the Urban Peripheries of Metropole Regions for Sustainable Development - Focused on Berlin, Milano and Seoul -)

  • 허윤경;채진해
    • 한국조경학회지
    • /
    • 제46권1호
    • /
    • pp.72-85
    • /
    • 2018
  • 본 연구는 지속가능한 도시 발전을 위해 도시 외연부 녹지를 활용한 해외사례에 주목하였다. 그 대상으로 서울의 외연부 녹지와 입지적 형태적 상황이 유사한 독일 베를린-브란덴부르크 광역공원화 사례와 이탈리아 밀라노의 방사형 녹지축 사례를 선정 및 분석하였다. 분석의 틀로 기존 인프라 접근성 및 연계, 재활용, 협력적 관리를 세웠다. 사례분석 결과는 다음과 같다. 첫째, 도시 외연부 녹지의 생태적, 문화적 특성을 고려한 차별화 된 공간 전략이 지속가능한 발전 계획의 토대로 이용되었다. 둘째, 도시 중심에서 외곽으로 이어지는 물리적 연계가 생태적, 환경적 가치뿐 아니라, 주변 지역의 경제적 가치 향상과 연결되어 도시의 지속가능한 발전에 이바지하였다. 셋째, 도시 외연부에 걸쳐있는 녹지의 통합적인 협력 관리 시스템을 구축하여, 행정관리 주체의 다원화와 다양한 이해관계자 사이의 갈등을 유기적인 조절을 통해 지속성을 유지하고자 하였다. 연구의 시사점은 다음과 같다. 현재 서울 외연부는 녹지가 분산되어 있고 연속적인 산지가 이루어져 있으나, 전체 경관이 획일적이기 때문에, 도시 외연부 녹지 경관의 정체성을 재정립한 차별화 전략 수립이 필요하다. 또한, 주변부산지와 도심지 녹지를 적극적으로 연계하여 생태적 가치와 경제적 가치 창출을 도모하고, 궁극적으로 도심의 지속가능한 발전이 이루어질 수 있도록 도모해야 한다. 마지막으로, 도시 외연부에 위치한 녹지의 대부분이 여러 행정경계 상에 위치하여 녹지관리주체가 파편화 되어있는 현 실정을 해소하기 위한 통합적 관리 시스템을 구축해야 한다. 결론적으로 본 연구는 도심 중심의 도시 발전 관점에서 벗어나 도시 외연부 녹지의 접근성 및 연계, 활용 및 관리로부터 이루어지는 도심의 지속가능한 발전이 이루어질 수 있는 가능성을 확인하였다는 점에서 의의가 있다.

공원녹지기본계획의 운영체계 및 계획내용에 관한 연구 - 런던, 뉴욕, 베를린, 시드니, 서울 사례를 중심으로 - (A Study on Operational Systems & Planning Contents of Parks & Green Space Plan - Focused on London, New York, Berlin, Sydney, Seoul -)

  • 채진해;조경진;김승주;허윤경;황주영
    • 한국조경학회지
    • /
    • 제42권2호
    • /
    • pp.91-102
    • /
    • 2014
  • 최근 도시정책에서 도시공원이 차지하는 비중은 확대되고 있다. 좋은 도시공원체계 확보를 위해서 공원정책 및 계획에 대한 중요성이 커지고 있다. 이러한 상황에서 세계 주요도시의 공원녹지 관련 계획의 운영체계와 계획내용을 비교하는 것은 의미가 있다. 본 연구는 도시적 차원에서의 공원녹지기본계획의 운영체계 및 계획내용에 관한 비교연구이다. 연구대상지로는 영국 런던, 미국 뉴욕, 독일 베를린, 호주 시드니, 국내 서울을 선정하였고, 분석자료는 각 도시별 공원녹지 관련 기본계획 및 전략보고서를 중점적으로 분석하였다. 분석의 틀은 운영체계와 계획내용으로 구분하여 설정하였고 결과는 다음과 같다. 첫째, 공원녹지계획을 관련자원과 연계된 오픈 스페이스 계획으로 수립함으로써 자원의 통합적 관리 및 형평성에 대한 실천에 이바지하고자 한다. 둘째, 공원녹지계획이 초기의 양적 공급에서 질적가치의 향상으로 더 나아가 재활성화 및 재생에 이바지하는 방향으로 전환하고 있다. 셋째, '공급중심의 계획'에서 '수요에 기반한 평가' 모델로 전환함으로써 인구학적 변화, 트렌드 변화, 선호도 변화에 유연하게 대응하는 계획 모델로 수립되고 있다. 넷째, 계획의 주체, 수립단계별 참여 기회 확대, 참여구성원의 다양화를 통해 수동적 참여에서 적극적 참여계획으로 전환되고 있다. 공원녹지기본계획의 실천성을 제고하기 위해서는 공원녹지에 관한 새로운 인식변화를 적극 수용하고, 공원 거버넌스를 수용을 도입하며 상황에 기민하게 대응하는 유연한 계획접근이 필요하다.

Aspects Of Architectural Design Using BIM Technologies

  • Tikhonova, Oleksandra;Selikhova, Yana;Donenko, Vasyl;Kulik, Mykhailo;Frolov, Denys;Iasechko, Maksym
    • International Journal of Computer Science & Network Security
    • /
    • 제22권1호
    • /
    • pp.85-92
    • /
    • 2022
  • In this article, we look at the application of BIM (Building Information Modeling) in sustainable infrastructures. In response to global warming, energy shortages, and environmental degradation, people are trying to build eco-friendly, low-carbon cities and promote eco-friendly homes. A "green" building is the entire life cycle of a building that includes maximizing the conservation of resources (energy, water, land, and materials), protecting the environment, reducing pollution, providing people with healthy, comfortable, and efficient use of space, and establishing harmony between nature and architecture. In the field of ecological and sustainable buildings, BIM modeling can be integrated into buildings with analog energy, air flow analysis, and solar building ecosystems. Using BIM technologies, you can reduce the amount of waste and improve the quality of construction. These technologies create "visualization" of digital building models through multidimensional digital design solutions that provide" modeling and analysis "of Scientific Collaboration Platforms for designers, architects, utility engineers, developers, and even end users. Moreover, BIM helps them use three-dimensional digital models in project design and construction and operational management.

GIS를 활용한 생태면적률 산정 모델 개발 (Development of Biotope area ratio Estimation Model using GIS)

  • 이지수;이승욱;이승엽;홍원화
    • Spatial Information Research
    • /
    • 제19권2호
    • /
    • pp.9-18
    • /
    • 2011
  • 본 연구의 목적은 신도시 등의 조성에 있어 지속 가능한 발전을 도모하고 시민들에게 쾌적한 생활환경을 제공하기 위해 도입된 생태면적률을 산정하는 모델을 개발하여 구축의 효율성과 데이터베이스 유지관리의 간편성과 정확성을 확보함에 있다. 특히 생태면적률은 현재 환경영향 평가 뿐만 아니라 친환경 인증기준 중 생태환경기준으로 활용되고 있으나, 생태면적률의 산정도 구축을 위한 지표가 제시되어 있지 않기 때문에 결과자료의 누락, 데이터 수정보완의 어려움과 같은 문제가 있을 수 있다. 따라서 본 연구에서는 GIS를 통해 도형 자료를 구축하고 가중치의 속성정보를 통합하여 관리하는 모델을 제시하였다. 생태면적률 산정은 토지이용계획도를 기초로 하여 건폐지의 경우 옥상 및 벽면 녹화, 비건폐지의 경우 수공간, 인공지반, 틈새투수포장, 자연지반 녹지의 공간유형을 대상으로 한다. 가중치가 부여된 공간유형정보는 도형정보와 통합되고 통합된 자료는 향후 토지이용에 따른 분석을 위해 토지이용계획 정보를 블록 별로 부여한다. 한편, 공간유형별 가중치 적용의 경우 도출방법이 각 지자체나 적용 주체의 상황에 따라 특성에 맞게 판단기준의 조절이 가능하다. 따라서 그 수치가 유동적일 수 있으나 본 모델에서 수치변화에 대한 탄력적인 대응이 가능함으로써 간편하고 효율적인 데이터 구축의 모델로 활용될 수 있다.

도시차원의 빗물순환체계 요소별 입지선정에 관한 연구 - 개발예정지역의 환경생태계획 적용방안을 중심으로 - (A Study on Location Selection for Rainwater Circulation System Elements at a City Level - Focusing on the Application of the Environmental and Ecological Plan of a Development -)

  • 김효민;김귀곤
    • 한국조경학회지
    • /
    • 제40권3호
    • /
    • pp.1-11
    • /
    • 2012
  • 본 연구는 신도시 개발 등 규모가 비교적 큰 도시개발에 있어 빗물을 이용하여 자연적인 빗물순환체계를 구축하는데 중점을 두고 있다. 특히 통합빗물관리를 위한 자연적인 빗물순환체계 요소별 입지 선정 방법을 개발하여 수문환경의 변화를 최소화하고, 자연적인 물순환을 회복하여 저영향개발(LID)을 실현할 수 있으며, 이를 통해 유출량 저감뿐만 아니라 도시 내의 수공간 및 녹지공간의 증가로 인한 도시의 지속가능성을 증진시키는 데 목적이 있다. 통합빗물관리를 위한 빗물순환체계 요소별 입지 선정을 위한 최종적인 빗물순환체계 요소로는 집수, 침투, 여과, 저류, 이동 공간의 5가지 항목이 도출되었으며, 이를 토대로 각 요소별 입지선정 항목 및 기준을 설정하였다. 도출된 평가항목과 기준을 적용하기 위한 방법은 적합성지수 이론을 바탕으로 Gridcellanalysis를 실시하여 각 요소별로 적합성평가를 통해 주제도를 중첩하고 종합하여, 적합성지수에 따라 등급화 함으로써 요소별 조성가능 우선지역을 구분하도록 하였다. 개발된 방법은 경북 김천 혁신도시 개발예정지에 적용함으로써 그 실행가능성과 한계를 검토하였으며, 각 요소별 주제도의 중첩 결과는 Verylow, Low, Moderate, High, Veryhigh의 5단계로 구분하여, 공간 특성을 쉽게 파악할 수 있게 하였다. 마지막으로 적용한 결과를 바탕으로 현 토지이용계획도면 위에 빗물순환체계 구상도를 작성해 봄으로써 환경생태계획 후 세부공간계획 단계에서 물순환체계를 구축하는데 있어 유용하게 활용될 수 있으며, 지속가능한 도시개발을 위한 친환경적 도시계획의 수단으로 이용될 수 있다.

LID 기술 적용을 통한 공동주택단지 물순환 개선 연구 - 침투시설 적용을 중심으로 - (The Water Circulation Improvement of Apartment Complex by applying LID Technologies - Focused on the Application of Infiltration Facilities -)

  • 서주환;이인규
    • 한국조경학회지
    • /
    • 제41권5호
    • /
    • pp.68-77
    • /
    • 2013
  • 세계적인 기후변화 영향은 한반도의 강우패턴 변화와 그로 인한 홍수와 폭설, 가뭄 등의 급격한 기상이변으로 나타나고 있다. 이에 국내외적으로 기후변화대응 관련 다양한 대안이 검토되고 있으며, 선진외국에서는 10여 년 전부터 저영향개발(LID)을 통한 수자원의 활용과 환경 친화적인 개발에 관심을 기울이고 있다. 국내에서도 일부 개발 사업에 LID 기법을 적용하는 계획을 추진하고 있으며, 관련 기술의 연구개발이 진행 중이다. 그러나 민간이 손쉽게 활용할 수 있는 제도 및 기술이전이 부족한 실정이며, LID 요소기술의 실효성 또한 충분히 합의되지 못한 현실이다. 이에 LID 요소기술 중 공동주택단지에 적용하기 용이한 요소기술을 분류하고, 그 중 침투기능을 수행하는 요소기술을 대상으로 공동주택단지 조경공간에 적용하고, 물순환 모의(SWMM 5.0)를 시행하고, 기술의 실효성을 검증하였다. 이를 위하여 각기 다른 지역의 공동주택단지 3개소를 대상으로 미국 EPA의 SWMM 5.0을 활용한 강우모의를 실시하고, LID기법 적용 전, 후의 물순환 모의(침투량, 지표증발량, 지표유출량)를 실시하였다. 녹지공간에서 LID 기술의 중요성은 빗물의 양적 질적 조절과 공동주택단지의 Amenity를 증진 시키는 역할이다. 공동주택단지의 물리적 한계를 이해하고 원활한 수순환 계통의 적용을 위하여 LID 통합관리기술(IMPs)을 적용해야 하며, 이를 위하여 조경, 건축, 토목, 환경전문가간의 저영향개발에 대한 기술적 통섭의 노력이 요구된다.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF