• Title/Summary/Keyword: Integrated Operation System

Search Result 1,295, Processing Time 0.027 seconds

A Case Study on the Implementation of Integrated Operation System of the Nakdong River Estuary Barrage Due to the Drainage Gate Extension (낙동강 하굿둑의 배수문 증설에 따른 통합운영시스템의 구축 사례에 대한 연구)

  • Kim, Seokju;Lim, Taesoo;Kim, Minsoo
    • The Journal of Society for e-Business Studies
    • /
    • v.20 no.1
    • /
    • pp.183-199
    • /
    • 2015
  • Due to the Four Major Rivers Restoration Project, Nakdong River Estuary Barrage's designed flood quantity has been largely increased, and this has caused to construct several drainage gates at the right side of Eulsukdo island to secure the safety of downstream river area. For successful functioning of Nakdong River Estuary Barrage, such as flood control, disaster prevention, and the securing of sufficient water capacity, drainage gates at the both sides of island have to operate systematically and reliably. To manage this under restricted personnel and resources, we have implemented the IOS (Integrated Operation System) by integrating previous facilities and resources via information and communication technologies. The IOS has been designed to have higher availability and fault tolerance to function continuously even with the partial system's failure under the emergency situation like flood. Operators can use the system easily and acknowledge alarms of facilities through its IWS (Integrated Warning System) earlier. Preparing for Integrated Water Resources Management and Smart Water Grid, the architecture of IOS conformed to open system standards which will be helpful to link with the other systems easily.

Development of Distributed Rainfall-Runoff Modelling System Integrated with GIS (지리정보시스템과 통합된 분포형 강우-유출 모의 시스템 개발)

  • Choi, Yun-Seok;Kim, Kyung-Tak;Shim, Myung-Pil
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.3
    • /
    • pp.76-87
    • /
    • 2009
  • Most distributed models have been developed for data interchange between model for hydrological analysis and GIS(Geographic Information System). And some interface systems between them have been developed to operate the model conveniently. This study is about developing integrated system between model and GIS not coupled system based on file interchange or interface system. In this study, HyGIS-GRM which is integrated system between GRM(Grid based Rainfall-runoff Model) which is physically based distributed rainfall-runoff model and HyGIS(Hydro Geographic Information System) have been developed. HyGIS-GRM can carry out all the processes from preparing input data to appling them to model in the same system, and this operation environment can improve the efficiency of running the model and analyzing modeling results. HyGIS-GRM can provide objective modeling environment through establishing the process of integrated operation of GIS and distributed model, and we can obtain fundamental technologies for developing integrated system between GIS and water resources model.

  • PDF

A Study on the System Integration and Control Method of Radiant floor Cooling in Apartment Buildings (공동주택에서 바닥복사냉방의 시스템 구성과 제어 방안에 관한 연구)

  • 조영흠;석호태;김광우;여명석
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.107-115
    • /
    • 2004
  • The objective of this study is to show the system Integrations and control method for operation of the Radiant Floor Cooling. The systems for radiant floor cooling system consist of only using the radiant floor cooling and the radiant floor cooling integrated with a dehumidification system. And the study is suggested control method with composed radiant floor cooling system through simulations. Radiant floor cooling systems compose of four main parts: an existing radiant heating panel, manifold, cooling source and controller, and sensors. If dehumidifying or supplementary cooling is needed, additional equipments such as PAC and AHU are needed. Simulation results show that control method only using radiant floor cooling system can prevent condensation and set room air temperature with the exception of hot and humid periods and control method using the radiant floor cooling integrated with a dehumidification system is comfort thermal environments and can reduce the cooling load quickly, moreover, show comfort control method to meet various cooling operation situations.

A Study on the Development and Operation of Integrated Assessment System for National Competency Standard Professional Basic

  • Chang, Young-Hyun
    • International journal of advanced smart convergence
    • /
    • v.7 no.4
    • /
    • pp.121-127
    • /
    • 2018
  • This paper develops and builds an Integrated Assessment System for National Competency Standard Professional Basic. The integrated evaluation system for basic job competency in the National Competency Standards is developed to conduct examination by means of computers, smartphones and tablet PCs. The system can be used for the basic job competency test, examination for online cyber universities, job competency examination for enterprises, and the listening, reading, and speaking test in the foreign language proficiency examination and is even better in terms of facility investment and saved operating costs as well as efficient use of spaces in comparison with conventional evaluation schemes. Even greater synergy effects can be achieved by providing support for the integrated evaluation system for basic job competency in connection with the NCS qualification system. The evaluation system has been tested and practiced at a specialized high school and can be applied to the NCS education evaluation of the college and four-year college and to the selection examination of new employees of the company.

Integrated Control Center on the drawing board for the Northeast Asia Region Interconnected Power System (동북아 연합급전소 구상)

  • Yoon, Kap-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.20-23
    • /
    • 2005
  • This paper introduces the latest discussions on the Integrated Dispatch Center (IDC, or Integrated Control Center: ICC) for the Northeast Asia Region Interconnected Power System (NEAR-IPS). The IDC is for the safety and economical operation of the NEAR-IPS. The status and plans of the EPSs and the control systems (or dispatch centers) to be interconnected shall be reviewed and the consideration on the IDC to be built in the future shall be discussed.

  • PDF

Highly Intergrated Total Energy System and its Application in a Competitive Electricity Market (전력수급 종합시스템의 현황분석 및 전력산업 구조개편에 따른 전망)

  • Kim, Jung-Hoon;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1501-1505
    • /
    • 1999
  • Highly Integrated Total Energy System for system operational planning and analysis is a totally integrated computerized system for various parts of power system operation planning and power system analysis. It is developed by KEPCO for about 8 years, named HITES. Nowadays restructuring, deregulation, privatization and competition of electricity market is introduced in the world. This paper describes HITES application for two typical models of a competitive electricity market.

  • PDF

Design of Integrated Database Program for Optimal Operation of Distribution Automation System (배전지능화시스템 최적 운영을 위한 통합 데이터베이스 프로그램 설계)

  • Choi, Yun-Hyuk;Jang, Moon-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.987-993
    • /
    • 2018
  • In the existing distribution automation system, the database is managed by each distribution office. But there is a high possibility to happened a problem during a fault processing because the representation of the connection switches between distribution offices are complicated. In addition, if a distribution office will be going to collapse due to disaster, for example, a big fire or earthquake, its own database may be lost. In order to solve this problem, it is necessary to have a structure of an integrated database management from an integration center to under the distribution office. To do this, the integration center must store and manage it as the database using the own office code.

A Study on Enhancing the Load Power Factor from the Point of View of Economic Operation Using the Load Power Factor Sensitivity Method (부하역률 감도기법 적용에 의한 전력시스템의 경제운용 측면에서의 역률개선 방안 연구)

  • Lee B. H.;Kim J. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.153-155
    • /
    • 2004
  • Various problems such as the increase of the power loss and the voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost is used for determining the locations of reactive power compensation devices effectively and for enhancing the load power factor appropriately. In addition, the integrated costs are used for determining the value of the load power factor from the point of view of the economic operation. It is shown through the application to a large-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF

Development of Integrated Planning System for Efficient Container Terminal Operation (효율적인 컨테이너 터미널 운영 계획 작성을 위한 통합 시스템 개발)

  • 신재영;이채민
    • Journal of Intelligence and Information Systems
    • /
    • v.8 no.2
    • /
    • pp.71-89
    • /
    • 2002
  • In this paper, an integrated planning system is introduced for the efficient operation of container terminal. It consists of discharging and loading planning, yard planning, and berth scheduling subsystem. This interface of this system is considered for user's convenience, and the rule-based system is suggested and developed in order to make planning with automatic procedures, warning functions for errors.

  • PDF

The Analysis Method of Integrated Logistic System using Evolution Strategies and Data Envelopment Analysis (진화전략과 DEA를 이용한 통합 물류 시스템 분석 방법)

  • Um In-Sup;Lee Hong-Chul;Kang Jeong-Yun
    • Journal of the Korea Society for Simulation
    • /
    • v.13 no.4
    • /
    • pp.17-29
    • /
    • 2004
  • The focus of this study is to represent a methodology of analysis for integrated logistic system by means of the Evolution Strategies and Data Envelopment Analysis(DEA). The integrated logistic system is composed of AS/RS (Automated Storages and Retrieval System), AGVs(Automated Guided Vehicle System) and Conveyor System. We design the simulation alternatives with choosing the qualitative critical factors for the each subsystem. Evolution Strategies is used to optimize the quantitative critical factors and responses of each alternative. DEA is applied to measure the efficiency of the alternatives in order to select the optimal operation efficiency scheme. The method of analysis which combines Evolution Strategies with DEA can be used to analyze the qualitative and quantitative critical factors in the integrated logistic systems.

  • PDF