• 제목/요약/키워드: Integrated Operation System

검색결과 1,295건 처리시간 0.029초

IMPLEMENTATION OF A DECISION SUPPORT SYSTEM FOR INTEGRATED RIVER BASIN WATER MANAGEMENT IN KOREA

  • Shim Soon-Do;Shim Kyu-Cheoul
    • Water Engineering Research
    • /
    • 제5권4호
    • /
    • pp.157-176
    • /
    • 2004
  • This research presents a prototype development and implementation of Decision Support System (DSS) for integrated river basin water management for the flood control. The DSS consists of Relational Database Management System, Hydrologic Data Monitoring System, Spatial Analysis Module, Spatial and Temporal Analysis for Rainfall Event Tool, Flood Forecasting Module, Real-Time Operation of Multi Reservoir System, and Dialog Module with Graphical User Interface and Graphic Display Systems. The developed DSS provides an automated process of alternative evaluation and selection within a flexible, fully integrated, interactive, centered relational database management system in a user-friendly computer environment. The river basin decision-maker for the flood control should expect that she or he could manage the flood events more effectively by fully grasping the hydrologic situation throughout the basin.

  • PDF

서울메트로 PSD 통합관제시스템 구축방안에 대한 연구 (Study on Implementation Scheme for Integrated PSD Control System of Seoul Metro)

  • 김용협;현용섭;류호중;김진수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1551-1559
    • /
    • 2007
  • Seoul Metro has been constructing the screen doors on the platforms to provide safe and comfort environments. The screen doors of each station are configured so that they can be operated in automatic mode in connection with ATC/ATO through the integrated control panel in the station control room and in manual mode through the control panel of the station control room and crew control panel. These systems have been implemented with different data communication protocols between systems, HMI configuration, and so on due to ordering processes, implementation time and diverse suppliers, and manufactured to be operated within single station. Seoul Metro has been planning to implement the integrated control system to secure seamless train operation and safety and to have a fast response system against emergency situations such as PSD failure and fire, by implementing the system that is able to collectively manage, monitor and control the operation status and equipment conditions of PSD on to the integrated control center. This paper has studied a scheme to reduce the budget for the future facility constructions by standardizing the data format for data communication with the integrated station control panel and using the open standard protocols, in order to secure consistency of operation, system expansion and maintenance with unified and standardized control items.

  • PDF

자동차 생산라인을 위한 통합창고 시스템 (Integrated Storage System For Automobile Production Line)

  • 김득수;서윤호
    • 산업경영시스템학회지
    • /
    • 제37권2호
    • /
    • pp.1-8
    • /
    • 2014
  • The automobile manufacture is a typical integrated assembly production that the numerous parts are committed sequentially to the assembly line. In this type of automobile manufacture, WBS (white body storage) and PBS (paint body storage) are operated to adjust the production sequence and to buffer. Starvation (impossibility of production owing to the insufficient supply) or blocking (impossibility of production owing to the over capacity) could occur in some chance, hence, both storages (WBS, PBS) are integrated as a prevention. This system is called integrated storage. In this paper, we suggest the simulation model of 'WBS-PBS integrated storage' and methodology of operation considering both 'Color grouping' and 'Option leveling.'

통합환경허가시스템의 활용도 제고 및 개선방향 (Enhancing the Applicability and Improvement Direction of Integrated Environmental Permit System)

  • 박재홍;신수정;이대균
    • 한국물환경학회지
    • /
    • 제34권3호
    • /
    • pp.339-345
    • /
    • 2018
  • The integrated environmental permit system is currently in operation online. It carries out various functions of postmanagement such as the submission of annual reports containing operations management data onto integrated management workplaces, the operation and management of emission facilities and prevention facilities, and the disclosure of information on the integrated permission. On the other hand, the integrated environmental permit system needs to perform various roles in order to stably manage and smoothly perform the permitting work. It is necessary to utilize this system to establish policies by using diverse operations management data onto integrated management workplaces collected in the integrated environmental permit system. This system can also play a role in improving the post-management system and user convenience after the permission review and approval processes. The integrated environmental permit system can be effectively used to set up the BAT-AEL because it collects all of the cross-media data and identifies the overall status of the workplace. In order to establish a post management system after the approval, it is necessary to provide performance management and performance evaluation functions as conditions of the permit after approval. In addition, a variety of support functions should be provided to enable the permission authority and the environmental expert examination agency to facilitate the review of permits. It will be necessary to provide an evaluation system and a proactive diagnostic function to determine whether permission conditions and permit emission standards will change in the future. Also, it is important to adopt an information exchange platform that can be used to collect the status data onto the workplaces; the platform can also be used as an information exchange site for technical working groups (TWG), and for collecting field experts' opinions.

국방M&S 정보관리 현황분석 및 획득업무 지원체계 개선방안 연구 (A Study on the Analysis of Information Management of the Defense M&S and Improvement of Aquisition Supporting System)

  • 정혜수;안호일;양진석
    • 인터넷정보학회논문지
    • /
    • 제21권2호
    • /
    • pp.131-138
    • /
    • 2020
  • 무기체계 소요제기부터 연구개발, 시험평가, 운영유지까지 국방 무기체계 획득 전 과정에서 활용하고 있는 국방M&S(Modeling & Simulation)정보를 과학적이고 체계적으로 관리하기 위해 SBA(Simulation Based Acquisition)통합정보체계가 구축·운영되고 있다. 국방 무기체계 획득 전 수명주기에 M&S자원을 적극적이고 효과적으로 활용하기 위해서는 SBA통합정보체계의 효율적인 운영방안이 필요하다. 이를 위해 SBA통합정보체계의 이용현황을 식별하고 운영성과측정을 수행한 결과, M&S자원 활성화와 획득업무 지원을 위해서는 SBA통합정보체계 운영 절차 수립과 더불어 세부적인 제도 마련이 필수적인 것으로 판단하였다. 본 논문에서는 SBA통합정보체계의 효율적인 운영을 위해 국방 M&S 정보관리 현황을 분석하고 국방 M&S 활성화와 체계적인 운영을 위한 정보체계의 개선방안을 제시한다.

전기자동차용 유·무선 통합 충전을 고려한 무선 충전 시스템의 두 가지 제어 방식에 따른 효율 비교·분석 (Comparison of Efficiency According to the Two Control Method of the Wireless Charging System Considering Wired/Wireless Integrated Charging System for EV)

  • 허훈;이주아;심동현;손원진;이병국
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.228-236
    • /
    • 2022
  • The charging methods of electric vehicles are divided into wired charging and wireless charging. Restrictions on the use of charging infrastructure for wireless charging vehicles currently exist because most charging infrastructure uses the wired charging method. Thus, wired and wireless integrated charging system has been studied. In this system, a wireless charging system especially requires a control method for high-efficiency operation in consideration of a change in a coupling coefficient. Therefore, this paper introduces two control methods for the high-efficiency operation of wireless charging that can be applied to wired and wireless integrated charging systems. In addition, loss analysis is performed through PSIM simulation to select a more advantageous method for high-efficiency operation among the two control methods. To verify the simulation-based loss analysis result, the two control methods are applied to the actual wireless charging system, and the efficiency is compared through the experiments Based on the experimental results, a control method suitable for high-efficiency operation of the wireless charging method is selected.

발전 통합 운영 시스템에 관한 연구 (The Study on the Generation Integrated Operating System(GIOS) in KOWACO)

  • 김흥년;김기원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2254-2256
    • /
    • 2004
  • Korea Water Resources Corporation (KOWACO), the only organization specialized in water resources management in Korea, is planning to establish a centralized control system for a related operation. in the central control room, of decision making as to water management and electric power generation. This plan is intended to convert the existing on-site operation system in each multi-purpose dam across the nation into a central operation system in the Corporations head office, for which Generation Integrated Operating System (GIOS) will be established control center in the Corporations head office and modernized nine (9) power stations. substations (RDAC). This article discusses realization of GTOS, especially real-time operation of hydropower plants and a specific architectural features for system communication.

  • PDF

FATIGUE LIFE ASSESSMENT OF REACTOR COOLANT SYSTEM COMPONENTS BY USING TRANSFER FUNCTIONS OF INTEGRATED FE MODEL

  • Choi, Shin-Beom;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Jhung, Myung-Jo;Choi, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제42권5호
    • /
    • pp.590-599
    • /
    • 2010
  • Recently, efficient operation and practical management of power plants have become important issues in the nuclear industry. In particular, typical aging parameters such as stress and cumulative usage factor should be determined accurately for continued operation of a nuclear power plant beyond design life. However, most of the major components have been designed via conservative codes based on a 2-D concept, which do not take into account exact boundary conditions and asymmetric geometries. The present paper aims to suggest an effective fatigue evaluation methodology that uses a prototype of the integrated model and its transfer functions. The validity of the integrated 3-D Finite Element (FE) model was proven by comparing the analysis results of individual FE models. Also, mechanical and thermal transfer functions, known as Green's functions, were developed for the integrated model with the standard step input. Finally, the stresses estimated from the transfer functions were compared with those obtained from detailed 3-D FE analyses results at critical locations of the major components. The usefulness of the proposed fatigue evaluation methodology can be maximized by combining it with an on-line monitoring system, and this combination, will enhance the continued operations of old nuclear power plants.

지능화시설의 통합운영 방안 (Plans for the Integrated Operation of Intelligent Service Facilities)

  • 임두현;박정우;남광우
    • 한국지리정보학회지
    • /
    • 제20권1호
    • /
    • pp.127-136
    • /
    • 2017
  • U-City 기반시설의 구성요소는 지능화된 시설, 정보통신망, 통합운영센터로 구분되며, 기존 연구에서의 U-City기반시설은 효율적인 운영 관리의 필요성을 제시하고 있다. 그러나 그 중 법에서 정의하는 내용과 다르게 해석하는 경우가 지능화된 시설에서 빈번히 발생하고 있다. 이러한 문제의식을 토대로 국내 지능화시설 관련 법제도 및 운영관리의 문제점 등을 종합적으로 분석하여 지능화시설의 효율적 활용을 위한 통합운영방안을 마련하고자 한다. 이를 위해 관련 법제도와 실무담당자 인터뷰를 통해 지능화시설의 현황 및 문제점을 파악하고, 지능화 시설에서 생성된 도시정보 및 설치위치를 모두 포함한 통합 활용의 필요성을 도출하였다. 현재 정부부처 및 지자체는 ICT를 활용한 다양한 정보시스템을 구축 운영하고 U-City법에서는 통합적 관리 운영을 명시하고 있으나, 시설 운영주체에 대한 구체적인 책임과 권한에 관한 정의는 명확히 이루어지지 않고 있다. 이를 효율적으로 운영하기 위해 설치된 장비와 여기서 생성된 도시정보를 공동으로 활용할 수 있는 관련 부서 간 원활한 조정이 가능한 추진체계가 필요하다. 본 연구는 지능화시설의 관련법 및 법규들에 대한 논리적 연계의 관계를 정립하여 효율적인 지능화시설 설치 및 관리를 위해 일원화된 법적 시스템의 체계를 마련하고자 한다. 이를 통해 지능화시설의 통합연계 및 활용을 위한 관리체계의 기초 토대가 될 수 있을 것으로 기대한다.

국내 여름철 기후조건에서 DOAS와 TABS 통합시스템 냉방운전시 실내온열환경 및 운전특성 평가 (Evaluation on the Indoor Thermal Environment and Cooling Operation Characteristics of Thermally Activated Building System integrated with Dedicated Outdoor Air System during Cooling Operation in Hot and Humid Climate of Seoul)

  • 이윤선;이겨레;정웅준;임재한
    • 대한건축학회논문집:계획계
    • /
    • 제34권11호
    • /
    • pp.45-55
    • /
    • 2018
  • To reduce the energy consumption of HVAC system in buildings, thermally activated building system(TABS) has been applied to low energy building because of energy efficient performance and reduction of peak load. DOAS coupled with a parallel sensible cooling could be promising because TABS handles sensible heat load only. The purpose of this study was to evaluate the indoor thermal environment and cooling operation characteristic of TABS with dedicated outdoor air system(DOAS) in Korea climate. Indoor thermal environment and operation characteristic of TABS integrated with DOAS are investigated at different TABS operation schedules and climate conditions by simulation tests. The result shows that the DOAS is more suitable for hot and humid climates. And also it show that the potential of intermittent operation of TABS.