• Title/Summary/Keyword: Integrated Operation System

Search Result 1,308, Processing Time 0.028 seconds

The Case Study on Application of Software Reliability Analysis Model by Utilizing Failure History Data of Weapon System (무기체계의 고장 이력 데이터를 활용한 소프트웨어 신뢰도 분석 모델 적용 사례 연구)

  • Cho, Ilhoon;Hwang, Seongguk;Lee, Ikdo;Park, Yeonkyeong;Lee, Junghoon;Shin, Changhoon
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.296-304
    • /
    • 2017
  • Purpose: Recent weapon systems in defense have increased the complexity and importance of software when developing multifunctional equipment. In this study, we analyze the accuracy of the proposed software reliability model when applied to weapon systems. Methods: Determine the similarity between software reliability analysis results (prediction/estimation) utilizing data from developing weapon systems and system failures data during operation of weapon systems. Results: In case of a software reliability prediction model, the predicted failure rate was higher than the actual failure rate, and the estimation model was consistent with actual failure history data. Conclusion: The software prediction model needs to adjust the variables that are appropriate for the domestic weapon system environment. As the reliability of software is increasingly important in the defense industry, continuous efforts are needed to ensure accurate reliability analysis in the development of weapon systems.

Integrated Simulation Model for Designing Distributed Energy Management System in Microgrid System (마이크로그리드시스템의 분산 에너지관리시스템 설계를 위한 통합시뮬레이션 모델 개발)

  • Cho, Jae-Hoon;Park, Sun-Hong;Lee, Dae-Jong;Cho, Young-Im;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.1
    • /
    • pp.29-35
    • /
    • 2011
  • In this paper, an integrated simulation model for designing multi-agent system based DEMS (distributed energy management system) in stand-alone micro-grid system is proposed. In the design of the EMS(energy management system), the multi-agent based DEMS are more effective than conventional centralized EMS, but it is difficult to design the DEMS by general design tools for power system because of various states of a microgrid system during operation of stand-alone mode. Also, since performance test of the DEMS using a real system is inefficient, an integrated simulation model is required for designing an effective multi-agent system based DEMS. The proposed model consists of Matlab/SimPowerSystems based simulation model of the microgrid system and the Multi-agnet based DEMS designed by Matlab/StateFlow tool. In order to show the effect of the proposed model, the model outputs are analyzed for specified operation conditions.

Development of Missile Design Computer Framework for the Multidisciplinary Optimization (유도무기 통합최적화설계를 위한 전산프레임워크 개발연구)

  • Kim Woo-Hyun;Lee Seung-Jin;Lee Jae-Woo;Byun Yung-Hwan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.307-314
    • /
    • 2006
  • Missile system. which requires high speed/high maneuverability is getting more important as a defensive weapon system. Integrated design environment which includes all related resources during the missile development process, is a very useful development tool, Therefor the design framework can perform the operation analysis and utilize design information for the efficient missile design. For this purpose, various analysis computer codes under heterogeneous platforms and operating systems, the database, the optimization module, and Ideas a commercial CAD are integrated using distributed. middleware. and the complicated GUI design has been made for the specific missile system design. Under the various constraint, maximize missile range and loadfactor with missile design computer framework.

  • PDF

Noise Test and Evaluation of a 750kW Wind Turbine Generator (750kW 풍력발전기의 소음실증)

  • Kim, Seock-Hyun;Heo, Wook;Lee, Hyun-Woo
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.59-64
    • /
    • 2007
  • This study introduces an environmental noise evaluation procedure and results for a wind turbine (W/T) system. Test and evaluation are required by the international standard IEC 61400-11 in the aspect of environmental effect. Test and evaluation are performed on U-50 WT model which is first developed by the domestic W/T manufacturer. W/T test model is under operation in Daekwanryung wind test site. An integrated monitoring system in the test site is utilized for the evaluation. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level are estimated and compared with those of other similar size WT under the wind speeds required by international standard.

  • PDF

A study on Design and Efficient Management of 30kW BIPV System (건물통합형 30kW태양광발전시스템의 설계 및 효율적 운전관리에 관한 연구)

  • Park, Se-Joon;Lim, Jung-Yeol;Yoon, Seok-Am;Cha, In-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.15-20
    • /
    • 2008
  • Building-integrated photovoltaics(BIPV) are increasingly incorporated into new domestic and industrial buildings as a principal or ancillary source of electrical power, and are one of the fastest growing segments of the photovoltaic industry. This paper presents design, operational features analysis, and PCS(Power Conditioning System) of grid-connected 30kW BIPV set up on the library of Dongshin University. For a sustainable photovoltaics system in this area, the data of the BIPV system are collected and analyzed by monitoring system using LabView. PCS of the grid-connected BIPV system, also, is designed for optimal operation with characteristics suggested in this paper.

Simulation Analysis and Development of Matlab/Simulink Model for Stand-alone Operation of Emergency Diesel Synchronous Generator-based Hybrid Energy System (비상용 디젤동기발전시스템기반 독립운전 하이브리드에너지시스템 모델 설정 및 시뮬레이션 분석에 관한 연구)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.70-79
    • /
    • 2015
  • In this paper, enhanced stand-alone operation and development of Matlab/Simulink model of emergency diesel based hybrid energy system is presented. Simulations based on the remote community or islands were performed for PV-diesel-battery hybrid system. Modeling of PV-diesel-battery integrated system is done to perform under the solar radiation and load conditions on Matlab/Simulink platform. The models of diesel generator unit, battery energy storage system, PV and frequency-power control are developed and simulation studies have been carried out under various conditions using Matlab/Simulink and SimPowerSystem. It is demonstrated that the proposed system can provide reliable and good quality power to the customers in diesel synchronous generator-based hybrid energy systems.

A Study on the Adoption of Self Bag-Drop System to Enhance Airport Operation (공항운영 향상을 위한 Self Bag-Drop System(무인수하물처리시스템) 적용가능성 연구)

  • Lee, Kang-Seok;Ji, Min-Seok
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.23 no.2
    • /
    • pp.75-83
    • /
    • 2015
  • Advanced countries in the aviation industry, especially the United States and European Union, develop and commercialize their own SBD system integrated with IT convergence technology, dominating the international market. Nevertheless, most of SBD technologies in domestic airports rely on other countries. It is imperative that internal airport operators introduce the Self Bag Drop system and produce, apply, and manage the most optimized SBD system for airports and airlines. Upon analyzing the tendency and operation of the SBD system utilized in leading international airports, this is conducted to address the possibility of the future implementation in domestic airports.

Mode Switching Smooth Control of Transient Process of Grid-Connected 400 Hz Solid-State Power Supply System

  • Zhu, Jun-Jie;Nie, Zi-Ling;Zhang, Yin-Feng;Han, Yi
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2327-2337
    • /
    • 2016
  • The mode-switching control of transient process is important to grid-connected 400 Hz solid-state power supply systems. Therefore, this paper analyzes the principle of on-grid and islanding operation of the system with or without local loads in the grid-connected process and provides a theoretical study of the effect of different switching sequences on the mode-switching transient process. The conclusion is that the mode switch (MS) must be turned on before the solid-state switch (STS) in the on-grid process and that STS must be turned off before the MS in the off-grid process. A strategy of mode-switching smooth control for transient process of the system is proposed, including its concrete steps. The strategy utilizes the average distribution of peak currents and the smooth adjustment of peak currents and phases to achieve a no-shock grid connection. The simulation and experimental results show that the theoretical analysis is correct and that the method is effective.

A Study on The Assesment of Power Improvement Effectiveness of Corps Level C4I System Applied to Integrated Fire Operation (지상전술 C4I체계의 통합화력운용간 전투력 상승효과 평가에 관한 연구)

  • 박송기;이재영
    • Journal of the military operations research society of Korea
    • /
    • v.29 no.1
    • /
    • pp.8-27
    • /
    • 2003
  • This paper develops a methodology that can be used to quantify the assesment of power improvement effectiveness of corps level C4I system applied to integrated fire operation by adapting Schuzer's C2 theory. This paper first describes how C4I systers can enhance the battle outcome in three way. : (1) Enhanced unit probability of survival; (2) Enhanced unit's individual effectiveness; improved exchange ratios; (3) Improved task force allocations : increased percentage of assets that can be assigned to a given engagement These enhancements are then show to result from improved probability of detection through information sharing; improved survivability and lethality through battle force coordination; and enhanced force allocation and prepositioning through improved timeliness of information(more advanced warning). It demonstrates that well-designed C4I systems can be shown to represent a significant force multiplier on the outcome of the battle.

A Study on Integrated Operation Strategies Between New & Renewable Energy Policy and Demand Side Management Policy (신재생에너지 정책과 수요관리 정책의 통합 운영 전략에 관한 연구)

  • Hwang, Sungwook;Jung, Hoon;Nah, Hwanseon;Won, Jongryul;Kim, Junghoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.144-144
    • /
    • 2010
  • Reasonable usage methods of energy resources, which are limited for human beings to use, consists of new & renewable energy (NRE) and demand side management (DSM). All technologies and policies for energy resources are classified into two fields, methods for using new energy resources and methods for using conventional fuel energy resources. Various development activities for these fileds have been implemented and various subsidy programs have been operated to penetrate into markets rapidly. These subsidy programs have various types of subsidy by energy resources and programs and the budget are funded by government, which is called Electric Power Industry Basis Fund and is managed considering technology level, economic analysis, global environment, etc. These subsidy programs are managed by Korea Energy Management Corporation (KEMCO) for NRE and by Korea Electric Power Corporation (KEPCO) for DSM, the management are different among two corporations because the purposes and features of establishment are different though these are all public organization. KEMCO is managing the NRE subsidy programs according to the government will, while the management of KEPCO subjects to power system operations though the government will for DSM is considered. NRE which is on the initial phase of diffusion would not affect on power system seriously but the affects could be grown when the diffusion and importance are expanded. Hence some integrated affection analyses considering NRE and DSM are required and this paper shows the concept of integrated operation strategies with ground source heat pump systems which are related with two fields simultaneously.

  • PDF