• Title/Summary/Keyword: Integrated Magnetic

Search Result 283, Processing Time 0.024 seconds

Pin Distribute Method of Twist Cable at Military Unmanned Vehicle Wiring Unit Connector (군용 무인 이동체 배선장치 커넥터에서 트위스트 케이블 핀 배치 최적화 방안)

  • Eun, Hee-hyun;Roh, Dong-gyu;Kwak, Gyu-min;Kim, Jae-seung;Lee, Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.245-250
    • /
    • 2020
  • Currently, unmanned military vehicles under development in Korea have more devices to carry out various missions, and interface cables between them are also increasing. In addition, due to a small space problem inside the unmanned vehicle, devices are required to be miniaturized and integrated. For two reasons, connectors also need to be selected, which makes them vulnerable to noise due to the closer distance between the pins. In this paper, we analyzed how much the magnetic field produced by noise at the connector pin where cable twist is released affects the surrounding pin and presented the guide for optimal pin placement. First, the effect of magnetic field is greater than the crosstalk between pin and pin. Second, the magnetic field on both sides between + and - is strong when approaching one step with noise source. Third, the magnetic field strength is improved when setting the ground pin as the ground pin between the noise and the original signal when approaching the A noise source and the two steps. Fourth, in the case of a differential mode communication, the optimal placement area of the sensitive signal was presented according to positions Tx± and Rx±.

Design and Fabrication of 10 GHz Substrate Integrated Waveguide Band Pass Filter Based on EM Simulation (10 GHz 대역 기판 집적 도파관 대역 통과 여파기의 EM 시뮬레이션을 이용한 설계 및 제작)

  • Lee, Won-Hee;Oh, Hyun-Seok;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.2
    • /
    • pp.99-109
    • /
    • 2010
  • Recently, SIW(Substrate Integrated Waveguide) is intensively studied because of its high Q and easy integration with other devices. However, lacks of analytic characterization of SIW makes it difficult an accurate design of a SIW filter along the conventional filter design method. In this paper, two kinds of a three-stage 10 GHz SIW bandpass filter of fractional bandwidth 10% are designed using 3D EM simulator HFSS based on the recently presented EM filter design method. Two types of a modified CPW to SIW transition is proposed and employed as a SIW to microstrip transition necessary for measurement. The transitions provide an easy measurement with commercial test fixture by TRL calibration. The two proposed transitions are included in the SIW filters. The fabricated filters shows the center frequency of 10 GHz, fractional bandwidth 10%, a return loss of about 12 dB, and insertion loss of about 0.8 dB.

A Study on Properties of a Near-Field Microwave Microscope Using a Waveguide Resonator (도파관 공진기를 이용한 마이크로파 근접장 현미경의 특성에 관한 연구)

  • Kim, Hyun;Kim, Song-Hui;Kim, Joo-Young;Lee, Kie-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.16-24
    • /
    • 2008
  • Near-field scanning microwave microscope (NSMM) has been used to characterize the electromagnetic properties of samples based on a cavity perturbation technique. We used a NSMM using a waveguide cavity to couple a metallic probe tip as a point like evanescent field emitter. We explained the quality of our NSMM system by applying the cavity perturbation theory. First, to make a shape perturbation, we inserted linear and loop probes in the waveguide resonator. To check up electric and magnetic field distribution inside the waveguide resonator by shape perturbation, we confirmed the field distribution by using a HFSS simulation. Second, to make material perturbation, we located a dielectric sample in front of the probe tip and measured reflection coefficient $(S_{11})$. We found that the resonance frequency$(f_r)$ was changed linearly as the dielectric constant of resonator$({\varepsilon}_r)$ increased when ${\Delta}{\varepsilon}\;and\;{\Delta}{\mu}$ were small.

Optimal Design of a Fine Actuator for Optical Pick-up (광픽업 미세구동부의 최적설계)

  • Lee, Moon-G;Gweon, Dae-Gab
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.5
    • /
    • pp.819-827
    • /
    • 1997
  • In this paper, a new modeling of a fine actuator for an optical pick-up has been proposed and multiobjective optimization of the actuator has been performed. The fine actuator is constituted of the bobbin which is supported by wire suspension, the coils which wind around the bobbin, and the magnets which cause the magnetic flux. If current flows in the coils, magnetic force is so produced as to be balanced with spring force of wire, so the bobbin is pisitioned. In this model the transfer function from input voltage to output displacementof bobbin has been obtained so that we can describe this integrated system with electromagnetic and mechanical parts. Wire suspension is regarded as a continuous Euler beam, damper as distributed viscous damping, and bobbin as a rigid body which can move up- and down- ward motion only. According to the model, the high frequency dynamic characteristics of the fine actuator can be known and the effect of damping can be investigated while the conventional second order model cannot. In multiobjective optimization, two objective functions have been chosen to maximize the fundamental frequency and the sensitivity with respect to the input voltage of the actuator so that Pareto's optimal solutions have been obtained using .epsilon.-constraint method. These objective functions will satisfy the trends which will enhance the access speed and reduce the tracking error in the optical pick-up technology of next generation. In the result of optimization, we obtain the designs of the optical pick-up fine actuator which has high speed, high sensitivity and low resonant peak. Furthermore, we offer the relation between two object functions so that the designer can make easy choice.

Double rectangular spiral inductor의 제조에 관한 연구

  • 김충식;신동훈;정종한;남승의;김형준
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.144-144
    • /
    • 1999
  • 최근 국내 반도체 기술의 비약적인 발전으로 전자 기기 전반에 소형화, 고주파화, 고기능화 등이 진행되는데 반해, 반도체 소자등에 전원을 공급하거나 회로 전체를 운용하는 전기 신호를 변조.증폭시키는데 반해, 반도체 소자등에 전원을 공급하거나 회로 전체를 운용하는 전기신호를 변조.증폭시키는 인덕터, 트랜스 포머와 같은 수동 자기 소자는 아직도 3차원 벌크 형태로 사용되고 있다. 일본을 중심으로 각국에서는 자기 소자의 박막.소형화에 대한 다각도의 연구가 진행되었으나 국내서는 아직 미미한 실정이다. 따라서 고집적 전원 공급 장치나 지능 센서 등에 반도체와 자기 소자의 사용 주파수 대역과 크기가 통합된 반도체-자성체 IC(semiconductor-magnetic integrated circuit)의 필요성이 절실히 요구되고 있다. 현재 사용중인 벌크형 인덕터나, 트랜스 포머의 경우 10NHz이상의 고주파 대역에는 응용되지 못하고 있다. 이는 적용된 자성체가 페라이트(ferrite)로서 초투자율은 크지만 고주파대역에서의 공진 현상에 의해 저투자율을 나타내고, 포화 자속밀도가 낮기 때문이다. 이러한 페라이트 자성체의 대체품으로 주목받고 있는 것이 Fe, Co계 고비저항 자성마이다. 그러나 Co는 낮은 포화자속밀도를 나타내기 때문에 이러한 조건을 충족시키는 자성막으로 Fe계 미세 결정막을 사용하였다. 본 연구에서는 선택적 전기 도금법(selective electroplating method)과 LIGA like process를 이용하여 공시형 인덕터(air core inductor)의 라이브러리(library)를 구축한 뒤, 고주파 대역에서의 우수한 연자기 특성을 가지는 Ti/FeTaN막을 적용한 자기 박막 인덕터(magnetic thin film inductor)를 제작하여 비교.분석하였다. 제조된 인덕터의 특성 추정은 impedence analyzer를 이용하여 주파수에 따른 저항(resistance), 인덕턴스(inductance)를 측정, 계산한 성능지수(quality factor)로서 인덕터의 성능을 평가하였다. 제조된 박막 인덕터의 코일 형상은 5턴의 double rectangular spiral 구조였으며, 적용된 자성막의 유효 투자율9effective permeability)은 1500, 자성막, 절연막 그리고 코일의 두께는 각각 2$\mu\textrm{m}$, 1$\mu\textrm{m}$, 20$\mu\textrm{m}$이며 코일의 폭은 100$\mu\textrm{m}$, 코일간의 간격은 100$\mu\textrm{m}$였다. 제조된 박막 인덕터는 5MHz에서 1.0$\mu$H의 인덕턴스를 나타내었으며 dc current dervability는 100mA까지 유지되었다.

  • PDF

Comparative Serum Proteomic Analysis of Serum Diagnosis Proteins of Colorectal Cancer Based on Magnetic Bead Separation and MALDI-TOF Mass Spectrometry

  • Deng, Bao-Guo;Yao, Jin-Hua;Liu, Qing-Yin;Feng, Xian-Jun;Liu, Dong;Zhao, Li;Tu, Bin;Yang, Fan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.6069-6075
    • /
    • 2013
  • Background: At present, the diagnosis of colorectal cancer (CRC) requires a colorectal biopsy which is an invasive procedure. We undertook this pilot study to develop an alternative method and potential new biomarkers for diagnosis, and validated a set of well-integrated tools called ClinProt to investigate the serum peptidome in CRC patients. Methods: Fasting blood samples from 67 patients diagnosed with CRC by histological diagnosis, 55 patients diagnosed with colorectal adenoma by biopsy, and 65 healthy volunteers were collected. Division was into a model construction group and an external validation group randomly. The present work focused on serum proteomic analysis of model construction group by ClinProt Kit combined with mass spectrometry. This approach allowed construction of a peptide pattern able to differentiate the studied populations. An external validation group was used to verify the diagnostic capability of the peptidome pattern blindly. An immunoassay method was used to determine serum CEA of CRC and controls. Results: The results showed 59 differential peptide peaks in CRC, colorectal adenoma and health volunteers. A genetic algorithm was used to set up the classification models. Four of the identified peaks at m/z 797, 810, 4078 and 5343 were used to construct peptidome patterns, achieving an accuracy of 100% (> CEA, P<0.05). Furthermore, the peptidome patterns could differentiate the validation group with high accuracy close to 100%. Conclusions: Our results showed that proteomic analysis of serum with MALDI-TOF MS is a fast and reproducible approach, which may provide a novel approach to screening for CRC.

Preparation of Spherical TiO2 Nanoparticles Using Amphiphilic PCZ-r-PEG Random Copolymer Template Membrane (양친성 PCZ-r-PEG 랜덤 공중합체 분리막을 이용한 구형 이산화티타늄 나노입자의 제조)

  • Lee, Jae Hun;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.29 no.3
    • /
    • pp.183-189
    • /
    • 2019
  • Amphiphilic PCZ-r-PEG random copolymer assisted solvothermal process is used to prepare mesoporous $TiO_2$ microspheres generated from nanoparticles by self-assembly method. Synthesized PCZ-r-PEG is characterized by Fourier transform infrared spectroscopy (FT-IR), nuclear magnetic resonance (NMR), gel permeation chromatography (GPC) and transmission electron microscopy (TEM). The mesoporous $TiO_2$ are prepared by PCZ-r-PEG, glucose, water in tertrahydrofuran solution at $150^{\circ}C$ for 12 h and the $TiO_2$ microspheres are calcined at $550^{\circ}C$ for 30 min to further crystallize and organic residue are removed. Morphology and crystallization phase is characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) respectively. The mesoporous $TiO_2$ crystallized in pure anatase phase with diameter of $300{\pm}20nm$.

A Review on Effects of Non-Invasive Brain Stimulation in the Treatment of Sleep Disorders (수면장애에서 비침습적 뇌자극술의 치료 효과 고찰: 경두개자기자극술과 경두개직류전기자극술을 중심으로)

  • Kim, Shinhye;Lee, Suji;Lim, Soo Mee;Yoon, Sujung
    • Sleep Medicine and Psychophysiology
    • /
    • v.28 no.2
    • /
    • pp.53-69
    • /
    • 2021
  • Sleep disorders, increasingly prevalent in the general population, induce impairment in daytime functioning and other clinical problems. As changes in cortical excitability have been reported as potential pathophysiological mechanisms underlying sleep disorders, multiple studies have explored clinical effects of modulating cortical excitability through non-invasive brain stimulation in treating sleep disorders. In this study, we critically reviewed clinical studies using non-invasive brain stimulation, particularly transcranial magnetic stimulation (TMS) and transcranial direct current stimulation (tDCS), for treatment of sleep disorders. Previous studies have reported inconsistent therapeutic effects of TMS and tDCS for various kinds of sleep disorders. Specifically, low-frequency repetitive TMS (rTMS) and cathodal tDCS, both of which exert an inhibitory effect on cortical excitability, have shown inconsistent therapeutic effects for insomnia. On the other hand, high-frequency rTMS and anodal tDCS, both of which facilitate cortical excitability, have improved the symptoms of hypersomnia. In studies of restless legs syndrome, high-frequency rTMS and anodal tDCS induced inconsistent therapeutic effects. Single TMS and rTMS have shown differential therapeutic effects for obstructive sleep apnea. These inconsistent findings indicate that the distinctive characteristics of each non-invasive brain stimulation method and specific pathophysiological mechanisms underlying particular sleep disorders should be considered in an integrated manner for treatment of various sleep disorders. Future studies are needed to provide optimized TMS and tDCS protocols for each sleep disorder, considering distinctive effects of non-invasive brain stimulation and pathophysiology of each sleep disorder.

A Conductive-grid based EMI Shielding Composite Film with a High Heat Dissipation Characteristic (전도성 그리드를 활용한 전자파 흡수차폐/방열 복합소재 필름)

  • Park, Byeongjin;Ryu, Seung Han;Kwon, Suk Jin;Kim, Suryeon;Lee, Sang Bok
    • Composites Research
    • /
    • v.35 no.3
    • /
    • pp.175-181
    • /
    • 2022
  • Due to the increasing number of wireless communication devices in mmWave frequency bands, there is a high demand for electromagnetic interference (EMI) shielding and heat dissipating materials to avoid device malfunctions. This paper proposes an EMI shielding composite film with a high heat dissipation characteristic. To achieve this, a conductive grid is integrated with a polymer-based composite layer including magnetic and heat dissipating filler materials. A high shielding effectiveness (>40 dB), low reflection shielding effectiveness (<3 dB), high thermal conductivity (>10 W/m·K), thin thickness (<500 ㎛) are simultaneously achieved with a tailored design of composite layer compositions and grid geometries in 5G communication band of 26.5 GHz.

Integrated Effect of Non-Invasive Neuromodulation on Bladder Capacity in Traumatic Spinal Cord Injury Patient: Single Case Report

  • Priyanka Dangi;Narkeesh Arumugam;Dinesh Suman
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.86-94
    • /
    • 2024
  • Objective: To evaluate the changes in bladder capacity and storage through non-invasive neuromodulation by application of repetitive Trans magnetic stimulation (rTMS) and genital nerve stimulation (GNS) in traumatic spinal cord survivors. Design: A Single Case Study. Method: The Patient was registered in trail with the clinical trial registry of India (CTRI/2022/05/042431). The Patient was interposed with rTMS on lumbar area, from T11-L4 vertebrae with 1 Hz and the intensity was 20% below that elicited local paraspinal muscular contraction for 13 minutes. GNS was placed over dorsum of the penis with the cathode at the base and anode 2 cm distally at 20 Hz, 200 microseconds, Continuous and biphasic current was delivered and amplitude of stimulation necessary to elicit the genito-anal reflex. For assessment, Neurological examination was done for peri-anal sensation (PAS), voluntary anal contraction (VAC) and bulbocavernous reflex (BCR), deep anal pressure (DAP), and American Spinal Injury Association Impairment Scale (ASIA scale). Outcome assessment was done using Urodynamics, Spinal Cord Independence Measure Scale Version-III (SCIM-III), American Spinal Injury Association Impairment Score (ASIA Score), Beck's Depression Inventory Scale (BDI). The baseline evaluation was taken on Day 0 and on Day 30. Results: The pre-and post-data were collected through ASIA score, SCIM-III, BDI and Urodynamics test which showed significant improvement in bladder capacity and storage outcomes in the urodynamics study across the span of 4 weeks. Conclusion: rTMS along with GNS showed improvement in bladder capacity & storage, on sensory-motor score, in functional independence of individual after SCI.