• 제목/요약/키워드: Insulation level

검색결과 341건 처리시간 0.022초

수직으로 설치된 비균질 평판 단열재용 성능시험장치 개발 (Development of Thermal Performance Tester for Non-Homogeneous Insulation Pannels Installed Vertically)

  • 오홍영;송기오;전현익;조선영
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.153-157
    • /
    • 2016
  • In case of metal insulation, which is produced by stacking stainless steel sheets and air layers in a multi-stack manner at a specific thickness, insulation performance will be evaluated based on thermal transmittance rather than the intrinsic physical properties of each material such as thermal conductivity. However, there is no standard for measuring thermal transmittance targeted for non-homogeneous insulation which is used in relatively high temperature conditions such as a power station. In this study, the thermal conductivity of homogeneous insulation acquired by the standardized guard hot plate method and the thermal conductivity of homogeneous insulation measured by the newly developed performance tester were compared to verify the confidence level of the tester. As a result, thermal conductivity acquired by the newly developed thermal transmittance tester was about 6% higher than the thermal conductivity measured by the existing guard hot plate method under the anticipated service temperature conditions.

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

초초고압 CV Cable용(用) 조립형 직선 접속함에서의 Stress Relief Cone 계면압력 최적화에 관한 연구 (A Study on the Optimization of Interfacial Pressure for the Stress Relief Cone in the Ultra-High Voltage Level Prefabricated Type Joint Box)

  • 백주흠;백승엽;이수길;허근도;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1614-1616
    • /
    • 1998
  • Insulation performance of major components of prefabricated joint such as epoxy insulation unit and premolded rubber cone are guaranteed by material selection design and proper manufacturing. On the other hand insulation performance of the interfaces between the premolded rubber cone and the epoxy insulation unit and the cable insulation is maintained by keeping the premolded rubber cone to close contact with such insulation by spring. Electric characteristics of a interface depend on the contact pressure, but the required characteristics are assured so far as a proper contact pressure is maintained. In this report, the interfacial pressure by pressure sensors both in the early stage and after heating cycle were measured and the simulation by FEM program were presented. The comparison of these two results show that interfacial pressure could be controlled optimally by changing the spring length and lubricant state of the interface.

  • PDF

전기콘센트의 사용환경과 전류값에 따른 열적특성 및 절연저항 분석 (Analysis of Thermal Characteristics and Insulation Resistance based on Usage Environment and Current Value of Electrical Socket Outlet)

  • 김경천;김두현;김성철
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.22-30
    • /
    • 2019
  • In 2018, overload, overcurrent, insulation aging, and a contact failure caused 659 electric fires. There is almost no failure of electrical socket outlets during their manufacturing or installation period. After several months or several years, overload or overcurrent of electrical socket outlets leads to a contact failure or short circuit which causes an electric fire. Therefore, this paper analyzed for thermal characteristics based on a current value and the change in insulation resistance along with a temperature rise caused by electrical socket outlets and the state of laboratory use in workplaces. As a results, regarding the thermal characteristics based on the current value of each installation year, a temperature increase was related to a current value, an installation year, and whether the contact unit is corroded. Insulation resistance began to decrease when a temperature increased to a certain level. With a lapse of installation year, the temperature at which insulation resistance began to decrease was lowered. This paper can be applicable for the survey data about electrical socket outlet induced fire accidents and management guidelines.

기능성과 보온성 향상을 위한 공군 정비파카 개발 및 평가 (Development and Evaluation of Air Force Mechanic Parka to Enhance the Functions and Insulation)

  • 이성지;최영림;남윤자
    • 한국의류산업학회지
    • /
    • 제14권2호
    • /
    • pp.294-303
    • /
    • 2012
  • This study was designed to develop air force mechanic parka, evaluate it, and ultimately provide functionally superior parka to the air force. The development process was 1) conducting a survey, 2) identifying problems and shortcomings of currently-supplied parkas, and 3) improving the design, pattern and materials. The newly-developed parkas were evaluated in terms of their ease of fit, clothing mobility, and insulation. Ease of fit was evaluated by subjects' sensory tests, and clothing mobility was by fitness-for-motion tests and range-of-motion tests using a Goniometer. Evaluation on insulation was conducted by thermal manikins. Findings of this study were as follows: 1. In the subjective evaluation on clothing mobility, new parkas were considered to have sufficient ease of fit while previous ones scored much lower, confirming the improvement of the new version. 2. Both subjective tests and ROM measurements on fitness for motion verified the superiority of the new parkas. 3. Insulation tests found that although insulation capability of newly-developed parkas was at a similar level to those of the previous ones, their insulation capability per unit weight was superior, demonstrating that new parkas were better at blocking heat conduction. When making changes in parka patterns and designs to enhance the mobility, it was necessary to maintain the insulation function. The new parkas developed by this study was verified to be superior to the previous ones in their insulation and clothing mobility.

Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul;Kim, Jae Ho
    • Safety and Health at Work
    • /
    • 제11권4호
    • /
    • pp.405-417
    • /
    • 2020
  • Background: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. Methods: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets' conductor surface and content, insulator weight, and thermal deformation temperature. Results: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 ℃. In relation to the installation year (30 years), insulation resistance decreased from 70 ℃, which is as much as 40 ℃ lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. Conclusion: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 ℃ of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 ℃. It is necessary to manage electrical socket outlets that have been installed for a long time.

전통주택의 차음성능 평가에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses)

  • 김선우;이태강;김형렬;김항;최은석
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.141-148
    • /
    • 2006
  • Korean traditional houses have been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various Passive system of using natural materials, considering micro climate, building lay out, and these system are much natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed the acoustical characteristics of Korean traditional houses varied with lay out and floor plan to reflect the way of control for environmental condition. The reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen are measured in each houses. As a result, the reverberation time of Korean traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building. These above results show that our traditional house are much more emphasized seeking visual privacy of rooms than aural privacy.

민항기와 군용기가 혼합된 공항 주변지역의 항공기 소음에 대한 거주자 반응 (Subjective Response for the Aircraft Noise in the Region around Airport mixed with Commercial and Military Aircrafts)

  • 백형배;박현구;김선우
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.99-106
    • /
    • 2009
  • This study aims to survey the acoustical environment in the region around airport where there are various transportation noises such as aircraft noise, railway noise and traffic noise, and to analyze the subjective response on the noise to the people who live in house or work in office nearby airport. Measurement and subjective response evaluation were carried out at the same time and outdoor noise level was measured all day long to calculate one day results such as average Leq or one day WECPNL etc. The results showed that the military aircraft produces very high level comparing with commercial aircraft, for instance the sound level of commercial outdoor was lower than that of military aircraft indoor. Double and triple window were more effective for controlling the noise than single window, which showed the possibility of sound insulation treatment by installing windows having higher sound insulation performance. Finally the subjective response was resulted that the most annoying noise is from aircraft and counterplan they hope is 'airport moving out'. Leq 65 dB(A), the criteria value of sound insulation treatment, was corresponding to the subjective response of median annoyance '4' out of 7th scale.

표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가 (Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source)

  • 이용봉;권혁제;김창환;조만희;김항;정성수
    • 한국음향학회지
    • /
    • 제42권2호
    • /
    • pp.143-151
    • /
    • 2023
  • 본 논문은 표준 중량충격원을 이용한 건축물의 바닥충격음 차단성능을 측정하는 경우 측정불확도를 평가하는 방법을 다루었다. 반복 측정의 영향 이외에도 측정 위치의 영향, 가진 위치의 영향, 음압측정에 사용된 장비의 영향 및 충격원의 영향 등을 고려하였다. 평균 최대 바닥충격음 레벨 측정의 수학적 모델을 제시하고 요인별 불확도 평가방법을 제안하였으며, 제안한 방법을 실제 측정 결과에 적용하여 평균 최대 바닥충격음 레벨 및 측정불확도를 평가하였다.

현장실험을 통한 학교교실의 벽체 차음성능 및 측로전달소음 조사 (Investigation of the sound insulation performance of walls and flanking noises in classrooms using field measurements)

  • 류다정;박찬재;한찬훈
    • 한국음향학회지
    • /
    • 제36권5호
    • /
    • pp.329-337
    • /
    • 2017
  • 미국과 영국에서는 교실의 적정한 음환경을 제공하기 위하여 잔향시간 및 배경소음에 대한 기준이 수립되어 있다. 또한 이를 실현하기 위한 건축계획방법 및 실내마감재 적용에 대한 가이드라인을 제시하고 있다. 그러나 대한민국의 경우 학교 교실의 배경소음 기준을 만족하기 위한 가이드라인이 부족할 뿐만 아니라 이에 기초가 되는 교실 벽체의 차음성능에 대한 실태조사가 부족한 실정이다. 본 연구에서는 학교 교실의 실내외 소음에 대한 차음성능을 조사하기 위하여 대한민국 청주시 소재 중학교 2개소의 외부벽체와 실간벽체의 구조를 조사하였다. 실내외 벽체의 차음성능 및 측로전달소음을 비교분석하기 위하여 투과손실, 가중 표준화 음압레벨차, 음향 감쇠 계수, 신호대잡음비 등을 측정하였다. 연구결과 실간벽체의 경우 건식벽으로 건립된 학교의 차음성능이 습식벽보다 높게 나타났으며, 특히 중고파수대역에서 높은 차음성능을 나타내었다. 외부벽체의 경우 각 학교 별로 차음성능을 비교하였을 때 단창을 이중으로 배치한 학교보다 복층유리를 사용한 학교의 성능이 더 높은 것으로 나타났다. 또한 측로전달소음의 경우 창문을 모두 개방하거나 복도 측 창문과 문을 연 경우 기준을 초과하는 것으로 나타나 내부 소음에 의해 학생이 음성전달에 방해를 받을 수 있음을 알 수 있었다.